• Title/Summary/Keyword: 알루미늄 판

Search Result 201, Processing Time 0.029 seconds

An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP) (고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구)

  • Choi, Hyun-Jun;Kim, Hyung-Chul;Lim, Sang-Woo;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.169-177
    • /
    • 2017
  • Rather than causing damage from heat, blast, and radiation of a regular nuclear weapon, recently, it is predicted that North Korea has been inventing high altitude electromagnetic pulse (HEMP) missile in order to incapacitate electronic equipment. HEMP shielding facility is used for military purpose today. Despite the electromagnetic shielding effects from high quality compression plates, problems may include such as the possibility of electromagnetic influx resulting in the welding of the compression plates, and difficulties and high cost of construction. Therefore, in this study, a high electrical conducting material was added to the concrete experimental subject to ensure the shielding effect through electromagnetic waves to for the concrete structure, instead of building a shielding facility separately for the structure. Also, among the experimental subjects, 100 ${\mu}m$ of Iron-Aluminum alloy metal spraying coat was applied to two types with the highest shielding effect, and to two types with the lowest shielding effect. The result of the experiment indicates that experimental subjects added with a high electrical conductivity material did not meet the minimum shielding criteria of MIL-STD-118-125-1 standard, but all the experimental material applied to the metal spraying coating satisfied the minimum shielding criteria. In conclusion, it is considered that 100 µm of Iron-Aluminum alloy metal spraying coat contains high efficiency in the HEMP shielding.

Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography (디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가)

  • An, Seo-Young;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2013
  • This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five disc-shaped specimens ($5mm{\times}1mm$) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink, Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.

Treatment of Livestock Wastewater by Electrochemical Method (전기화확적 방법에 의한 축산폐수의 처리)

  • Heo, Jong-Soo;Chung, Tae-Uk;Lee, Hong-Jae;Baek, Song-Bum;Cho, Ju-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.332-338
    • /
    • 1999
  • To treat livestock wastewater effectively by electrochemical method using a stainless steel electrode or au aluminum electrode, the effects of voltage, distance of electrodes and PACS(Poly Aluminum Chloride Silicate) dosage on removals of pollutants in batch experiment for investigation the optimum treatment conditions of livestock wastewater were investigated. The results were summarized as follows ; On the effect of voltage, temperature and pH in electrochemical reactor were increased with increase in voltage but EC was a reverse in both electrodes. Removals of COD and T-N were increased with increase in voltage in both electrodes. SS removal was greater than 90% regardless of voltage without doing electrochemical reaction over 15min at 20V or 12min at 30V in both electrodes. T-P removal was over 90% regardless of voltage in both electrodes. On the effect of distance between two electrodes, removals of COD, T-N and T-P were increased with closeness in distance between two electrodes, and SS removal was greeter than 90% regardless of distance between two electrodes in both electrodes. On the effect of PACS dosage, removals of COD, T-N and T-P were increased with increased in PACS dosage up to 200㎎/l in both electrodes. SS removal was greater than 90% regardless of PACS dosage in both electrodes.

  • PDF

Compressive Strength Restoration Evaluation of Sandwich Composite Laminates Repaired by Scarf Method (패치 보수된 샌드위치 복합재 적층판의 압축시 강도회복 평가)

  • Kim, Jung-Seok;Yoon, Hyuk-Jin;Kim, Seung-Cheol;Seo, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.110-114
    • /
    • 2009
  • This study is for the evaluation of compressive strength restoration of sandwich composite laminates with adhesively bonded scarf patches. It was used in this study that the sandwich composite laminate with an aluminum honeycomb core and CF1263 woven fabric carbon/epoxy faces was applied to the car body structure for Korean tiling train. In this study, it was damaged by low velocity impact and repaired using scarf repair method. Then, the compressive strength restoration of assessed by compressive after impact (CAI) test. From the test, it could be known that the compressive strength was restored up to 72% by only scarf repair method and 91% applied by an extra ply over the undamaged one.

A Practical Method of Acoustic Emission Source Location in Anisotropic Composite Laminates (이방성 적층복합재 구조에서 AE 발생원 위치표정을 위한 실용적인 방법)

  • Kim, Jeong-Kon;Kang, Yong-Kyu;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.237-245
    • /
    • 2003
  • Since the velocity is dependent on the fiber orientation in anisotropic composites, the application of traditional acoustic emission (AE) source location techniques based on the constant velocity to composite structures has been practically impossible. The anisotropy makes the source location procedure complicated and deteriorates the accuracy of the location. In this study, we have divided the region of interest(ROI) into a set of finite elements, taken each element as a virtual source, and calculated the arrival time differences between sensors by using the velocities at every degree from 0 to 90. The calculated and the experimentally measured values of the arrival time difference aye then compared to minimize the location error. The results from two different materials, namely AA6061-T6 and CFRP(uni-directional; UD, $[0]_{32}4$) laminate confirmed the practical usefulness of the proposed method.

The Effects of Protozoa on the Early Formation of Microbial Fouling Communities of Inchon Coastal Waters (인천 연안 미세오손생물 군집 형성과 원생동물의 영향)

  • Choi, Joong-Ki;Yang, Eun-Jin;Lee, Won-Je;Yoon, Won-Duk;Shim, Jae-Hyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.349-362
    • /
    • 1999
  • To understand the role of protozoa in the early formation of microbial fouling community, the studies on the formation of microbial film, the succession of microbial fouling communities, and the grazing pressure on bacteria population in microbial film were carried out in the laboratory, Inchon outer port and Inchon inner harbour. Bacteria and heterotrophic flagellates formed primary microbial film on the aluminum surface within 6 hours and oligotrich ciliates were observed 2 cells $mm^{-2}$ on the same surface at 9 hours in Inchon inner harbour which had physically stagnant condition. The larvaes of Balanus albicostatus which were dominant meiobenthos in Inchon coastal area attached on the glass surface at the first day of experiment. Heterotrophic flagellates showed maximum abundance of 465 cells $mm^{-2}$ at the 13rd day and ciliates showed maximum abundance of 63 cells $mm^{-2}$ at the 11st day in the Inchon inner harbour. In the Inchon outer port which opens to the outer sea, the maximum abundance of protozoa occurred at early phase, but not so many. The dominant heterotrophic flagellates were Metrornonas simplex and Bodonids. Dominant ciliates were small tintinnids and oligotrich ciliate Strombidium sp., Large Strombidium (oligotrich ciliate) and sessile Acineta turberosa (suctorian ciliate) occurred after 10 days. The attached larvae of Balanus occurred as biofouling organism on the early surface and showed maximum abundance of 18 indiv. $cm^{-2}$ at 7th day. At that time, adult barnacles were observed on the surface and dead barnacles were observed after two days. Except barnacles, the larvaes of Anthozoa sp., Oysters (Crassostrea gigas) and Polychaeta were observed on the surface from 3rd day. 3 benthic copepods including Harpacticus sp., I isopod, 1 polychaeta and 1 gastropoda were observed as predators of the microbial film on the surface after 7 days when microbial film developed very well. Although the ingestion rates of protozoa on the bactctia of the rnicrobi31 film were relatively low, the average grazing rate of protozoa on bacteria was high of 0.058 $h^{-1}$. This implied that the grazing pressure of protozoa influences the mortality of bacteria populations on the microbial film. but protozoa cannot get enough energy from only bacteria on the microbial film.

  • PDF

IS AN OXYGEN INHIBITION LAYER ESSENTIAL FOR THE INTERFACIAL BONDING BETWEEN RESIN COMPOSITE LAYERS? (Layering시 복합레진 층간의 계면 결합에서 oxygen inhibition layer가 필수적인가?)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • This study was aimed to investigate whether an oxygen inhibition layer (OIL) is essential for the interfacial bonding between resin composite layers or not. A composite (Z-250, 3M ESPE) was filled in two layers using two aluminum plate molds with a hole of 3.7 mm diameter. The surface of first layer of cured composite was prepared by one of five methods as followings, thereafter second layer of composite was filled and cured: Group 1 - OIL is allowed to remain on the surface of cured composite; Group 2 - OIL was removed by rubbing with acetone-soaked cotton; Group 3 - formation of the OIL was inhibited using a Mylar strip; Group 4 - OIL was covered with glycerin and light-cured; Group 5 (control) - composite was bulk-filled in a layer. The interfacial shear bond strength between two layers was tested and the fracture modes were observed. To investigate the propagation of polymerization reaction from active area having a photo-initiator to inactive area without the initiator, a flowable composite (Aelite Flow) or an adhesive resin (Adhesive of ScotchBond Multipurpose) was placed over an experimental composite (Exp_Com) which does not include a photoinitiator and light-cured. After sectioning the specimen, the cured thickness of the Exp_Com was measured. The bond strength of group 2, 3 and 4 did not show statistically significant difference with group 1. Groups 3 and 4 were not statistically significant different with control group 5. The cured thicknesses of Exp_Com under the flowable resin and adhesive resin were 20.95 (0.90) urn and 42.13 (2.09), respectively.

Effects of phosphate coating on some performance of painted Al alloy sheet (도장 알루미늄 합금판의 성능에 미치는 인산염피막의 영향)

  • 이규환;노병호
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.5
    • /
    • pp.289-299
    • /
    • 1995
  • The effects of phosphate coating have been studied on physical properties and corrosion resistance of painted aluminum alloy sheet for automobile body. The physical properties (surface roughness, paint adhesion, impact resistance and pencil hardness) and corrosion resistance(cyclic corrosion and filiform corrosion) were investigated. Phosphate coatings enhanced the physical properties of painted Al alloy sheet, especially paint adhesion after the 240hours water immersion test. Phosphate coating also markedly improved the resistance for cyclic corrosion and filiform corrosion of painted cold rolled steel and Zn-Ni plated steel sheet as well as painted Al alloy sheet. The corrosion resistance of painted Al sheets was varied with the concentration of free fluoride ion and metal additives like Ni and Mn in the phosphating bath. A maximum corrosion resistance was obtained at about 300ppm of fluoride ion and additives of Ni and Mn obviously increased the corrosion resistance of painted specimens.

  • PDF

Tensile Properties of Plate Attached Open Cell Aluminium Foams (판이 부착된 개포형 발포 알루미늄의 인장특성)

  • Kang, Bok-Hyun;Bu, Sung-Duk;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.27 no.2
    • /
    • pp.83-87
    • /
    • 2007
  • Aluminum plates of the same materials as the foam were attached by the casting process inserting the foam as a core to investigate the tensile property of open cell foams. Tensile properties of the open cell 6063 aluminum alloy foam of $10{\sim}30$ PPI were measured before and after heat treatment. Densities of test specimens were between 0.14 and $0.29g/cm^3$. Tensile strength of the 6063 aluminum foam after heat treatment showed little change. C values were in the range of $0.41{\sim}0.87$ for as cast foams and $0.11{\sim}0.27$ for T6 heat treated foams in the eq. of ${\sigma}^* _{pl}/{\sigma}_{ys}=C({\rho}/{\rho}_s)^{1.5}$, and increased with increase in the cell size.

An Experimental Study on Lap Joint using FSW with $2mm^t$ Aluminum Alloy Plate ($2mm^t$ 알루미늄합금재의 겹치기이음을 위한 마찰교반용접의 실험적 연구)

  • 장석기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.728-735
    • /
    • 2003
  • This paper shows the possibility of performing Lap joint using the friction stir welding with $2mm^t$ aluminum alloy plate and the determination of tool-dimensions for FSW in milling machine. This research also is reported on obtaining the tensile-shear strength, 91.3 (MPa) and the energy absorption, 26.3 (J) for Lap jointed specimen. The optimal tool-dimensions and method for Lap joint using FSW is as follows; each diameter of shoulder and pin is $9\phi(mm) and 3\phi(mm)$, the length of pin is 3.6(mm), Pressing the shoulder of tool into original base metal is not reasonable.