• Title/Summary/Keyword: 안정된 보행

Search Result 233, Processing Time 0.03 seconds

Information Fusion of Cameras and Laser Radars for Perception Systems of Autonomous Vehicles (영상 및 레이저레이더 정보융합을 통한 자율주행자동차의 주행환경인식 및 추적방법)

  • Lee, Minchae;Han, Jaehyun;Jang, Chulhoon;Sunwoo, Myoungho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.35-45
    • /
    • 2013
  • A autonomous vehicle requires improved and robust perception systems than conventional perception systems of intelligent vehicles. In particular, single sensor based perception systems have been widely studied by using cameras and laser radar sensors which are the most representative sensors for perception by providing object information such as distance information and object features. The distance information of the laser radar sensor is used for road environment perception of road structures, vehicles, and pedestrians. The image information of the camera is used for visual recognition such as lanes, crosswalks, and traffic signs. However, single sensor based perception systems suffer from false positives and true negatives which are caused by sensor limitations and road environments. Accordingly, information fusion systems are essentially required to ensure the robustness and stability of perception systems in harsh environments. This paper describes a perception system for autonomous vehicles, which performs information fusion to recognize road environments. Particularly, vision and laser radar sensors are fused together to detect lanes, crosswalks, and obstacles. The proposed perception system was validated on various roads and environmental conditions with an autonomous vehicle.

Evaluation of the Elderly Gait Stability Using the Center of Mass and Center of Pressure Inclination Angles (전, 후방 기울기각을 이용한 노인의 보행안정성 평가)

  • Yoon, Suk-Hoon;Kim, Tae-Sam;Lee, Jae-Hun;Ryu, Ji-Seon;Kwon, Young-Hoo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.99-106
    • /
    • 2007
  • The gait instability in the elderly has been associated with age-related deterioration in physical strength and reducing the potential for elderly falls requires regular exercise. In 2005, National Center for Injury Prevention and Control(NCIPC) reported that most elderly falls occur during activities in daily living(ADL). To better reveal biomechanic mechanisms underlying age-related degeneration in gait stability, and to enhance the assessment of falls risk, an accurate quantification of a person's balance maintenance during locomotion is needed. Instantaneous orientation of the line connecting COP and COM can characterize whole body position with respect to the supporting foot during gait and the angle between this line and the vertical line passing through the COP known as a good assessment to detect the elderly gait instability. Therefore the purpose of this study was to investigate a 6-month walking exercise effects in reducing elderly fall risk factors by using COP-COM inclination angles. Twenty-two community-dwelling elderly participated this study. The participants performed a walking exercise(3 times/week, 1 hour/visit) for 6 months. Laboratory kinematics during walking was assessed at months 0, 3 and 6. Significant increased in gait velocity was found among periods(p=.011, $1.25{\pm}.03$, $1.32{\pm}.03$, and $1.39{\pm}.04\;m/s$ in 0-, 3-, and 6-month, respectively). Also, significant differences in anterior and posteriror inclination angles were found among the periods(p<.05; posterior inclination angles: $12.8{\pm}2.2$, $11.0{\pm}2.9$, & $10.9{\pm}1.9$; anterior inclination angles: $13.7{\pm}1.7$, $14.6{\pm}3.2$, & $1.46{\pm}.21$ in 0month, 3month, & 6month, respectively). These findings provide evidence of significant reduced fall risk factors of community-living older adults associated with a systematic walking program.

Implementation of Multiple Nonlinearities Control for Stable Walking of a Humanoid Robot (휴머노이드 로봇의 안정적 보행을 위한 다중 비선형 제어기 구현)

  • Kong, Jung-Shik;Kim, Jin-Geol;Lee, Bo-Hee
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.2
    • /
    • pp.215-221
    • /
    • 2006
  • This paper is concerned with the control of multiple nonlinearities included in a humanoid robot system. A humanoid robot has some problems such as the structural instability, which leads to consider the control of multiple nonlinearities caused by driver parts as well as gear reducer. Saturation and backlash are typical examples of nonlinearities in the system. The conventional algorithms of backlash control were fuzzy algorithm, disturbance observer and neural network, etc. However, it is not easy to control the system by employing only single algorithm since the system usually includes multiple nonlinearities. In this paper, a switching Pill is considered for a control of saturation and a dual feedback algorithm is proposed for a backlash control. To implement the above algorithms, the system identification is firstly performed for the minimization of the difference between the results of simulation and experiment, and then the switching Pill gains are determined using genetic algorithm with some heuristic approach. The performance of the switching Pill controller for saturation and the dual feedback for backlash control is investigated through the simulation. Finally, it is shown that the implemented control system has good results and can be applied to the real humanoid robot system ISHURO.

A Study on Effects of the Fall Prevention in the Rehabilitation Pilates Exercise (노인의 재활 필라테스 운동이 낙상 예방 효과에 대한 고찰)

  • Ji-Sun Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.290-300
    • /
    • 2023
  • This study was understood the risk mechanism of falls in the elderly and reviewed previous research data to see if the principle of Pilates rehabilitation exercise could have a positive effect on balance ability and postural stabilization in the elderly, and the purpose of this study is to present literature-based data on the fall prevention effect of rehabilitation Pilates exercise. First, the rehabilitation Pilates exercise makes it available for strengthening the center of the body to stabilize the spine and pelvis and stimulates the nerve root, thereby having an effect on the balance and the joint stabilization. Second, a proprioceptive sensory impairment and a musculoskeletal degenerative disease due to aging increase the loss of balance ability and the instability in posture maintenance, thereby coming to raise the risk of a fall damage caused by the difficulty in performing motor functions and by the gait disturbance. Third, the rehabilitation Pilates exercise leads to improving the core muscle strength in older adults, resulting in being capable of expecting the betterment in the balance and the reaction time motor function. And there is a positive impact on the improvement in body imbalance and on the stability in movement involved in the fall prevention, resulting in being able to suggest the possibility of likely contributing to a reduction in a fall risk rate. In conclusion, the rehabilitation Pilates as the elderly exercise program showed effects on the improvement in the body's muscular strength, on the upgrade in a sense of balance, and on the stabilization of core. Thus, it was considered to diminish the risk factors for a fall damage caused by musculoskeletal degeneration and to be capable of preventing a serious disorder of activity due to a chronic senile disease.

Comparative analysis of inundation flow patterns and flood risk assessment methods within subway stations (지하철 역사 내 침수 흐름 분석 및 침수 위험도 평가 방법 비교)

  • Shin, Jaehyun;Kim, Minjeong;Cho, Inhwan;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.10
    • /
    • pp.667-678
    • /
    • 2023
  • In this study, quasi-3D inundation flow simulations were conducted for a simplified subway station configuration. The effects of variations in rainwater inflow locations and discharge were investigated, analyzing the resulting inundation flow patterns and flood risk. The inundation simulation results calculated the incipient velocities for slipping and toppling accidents to assess pedestrian safety. The results indicated that velocities exceeding the incipient velocity for slipping accidents mainly occurred on the flooded staircase. Meanwhile, velocities surpassing the incipient toppling accidents were observed around the staircase and the corridor near the staircase leading to B2F. This observation is consistent with the results from the specific force distribution analysis. To provide detailed flood risk assessments, the Flood Hazard Degree (FD) was applied with four levels of criteria, along with the Flood Intensity Factor (FIF). The results demonstrated that FD identified a broader area at risk of flood-induced consequences compared to FIF. When comparing the different inundation risk assessment methods, the specific force method tended to overestimate the risk area, whereas FIF tended to underestimate it. Furthermore, among all assessment methods, the influence of rainwater discharge was found to have a more dominant effect on flood risk assessment compared to the number of rainwater inflow locations. Additionally, the direction of inundation flow influenced the assessed risk, with collision-induced flow patterns leading to higher flood risk than those with identical flow directions.

Clinical Results of Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Tendon (슬괵건을 이용한 관절경적 전방십자인대 재건술)

  • Song, Eun-Kyoo;Seo, Hyoung-Yeon;Lee, Geun-Bae;Yoon, Taek-Rim;Shim, Sang-Don
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.17-23
    • /
    • 1999
  • Purpose : We intend to review clinical results after Anterior cruciate ligament(ACL) reconstruction using hamstring tendon arthroscopically. Materials & Methods : Sixty two patients who had underwent arthroscopic ACL reconstruction using hamstring tendon from Mar. 1996 to Mar. 1997 were reviewed. The average follow-up was 16 months and average age at operation was 27 years old. Clinical results were evaluated with physical examination, Lysholm Knee score and instrumented anterior laxity test with Telos Results : The average preoperative Lysholm knee score was 57.0 and postoperative average of that was 91.8. All cases of 62 patients had normal range of motion of knee and were able to walk with no problems at follow-up. On the Lachmann test, there were mild(+) instability in 24 cases, moderate(++) in 24 cases, severe(+++) in 14 cases preoperatively and 48 cases were converted to negative, 14 cases mild postoperatively. On instrumented anterior laxity test with Telos, difference between normal and affected knee on 20 lb which was 13.4mm preoperatively was decreased to 4.7mm at follow-up and anterior stability was regained(P<0.05). Parapatellar complications such as crepitus in 18 cases(29.5%), atrophy of quadriceps in 23 cases(36.5%) were observed. There were 2 cases of inaccuracy of guide pin of semifix screw intraoperatively and 3 cases of malposition of semifix screw postoperatively. Conclusion : ACL reconstruction using hamstring tendon seems to be a effective procedure to establish the stability of knee joint but is technically demanding procedure and leaves some parapatellar complications.

  • PDF

CT-guided Percutaneous Thermoablation for the Treatment of Osteoid Osteoma (경피적 고주파 열 치료를 이용한 유골 골종의 치료)

  • Sung, Ki-Sun;Seo, Jai-Gon;Ha, Hae-Chan
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.88-95
    • /
    • 2004
  • Purpose: Current treatment for osteoid osteomas is usually surgical excision of the nidus. Various minimal invasive techniques have been reported to overcome the invasiveness of the surgical excision. We treated 22 patients with osteoid osteoma by percutaneous thermoablation of the nidus under computed-tomography guidance. Materials and Methods: Twenty two consecutive patients underwent CT-guided percutaneous radio-frequency thermoablation between April 1999 and May 2004. The mean age was 26.5(7~55) years. In three cases, the diagnosis was confirmed pathologically before the prodedure while the others clinically and radiologically. Computed tomography (CT)-guided percutaneous RF ablation was performed with general or spinal anesthesia. With an RF electrode, the lesion was heated to 80 or 90 degrees C for 6(3~8) minutes. Clinical success was assessed at a mean of 30(4~62) months after the procedure at out patient clinic or by telephone interview. Results: The procedure was technically successful in all cases except a complication. Patients were discharged on 1.9 days after the procedure and resumed normal activities immediately. All patients but three (86%) remained pain free during follow-up (range 4~62 months). A second thermoablation treatment relieved the recurrent symptoms in 2 patients and the remained had persistent pain without a second prodedure. Conclusion: Percutaneous thermoablation appears to be safe and effective for osteoid osteomas, and is a minimally invasive procedure alternative to surgical resection.

  • PDF

Clinical Evaluation of TightRope Cranial Cruciate Ligament Technique for Treatment of Cranial Cruciate Ligament Deficiency in Dogs (전방 십자인대 결손을 보이는 개에서 TightRope을 이용한 치료방법 평가)

  • Yoon, Hun-Young;Kim, Kyung-Hee;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.455-459
    • /
    • 2012
  • Nine dogs presented to the Veterinary Medical Teaching Hospital of Konkuk University and Woosung Animal Hospital with a history of pelvic limb lameness. On physical examination, 9 dogs all showed a consistent weight bearing lameness and mild muscle atrophy. There was cranial drawer sign with pain in 9 dogs. Mediolateral radiographic projection revealed cranial subluxation of the tibial tuberosity in a tibial compression view. The right and left stifle joints were affected in 7 dogs and 2 dogs respectively. TightRope cranial cruciate ligament (CCL) technique for treatment of CCL deficiency was performed. Polyester and nylon were used to stabilize the stifle in 3 dogs and 6 dogs respectively. Suture sizes were 0.8 mm (n = 2), 0.9 mm (n = 4), 1.1 mm (n = 2), and $1.1mm{\times}2$ strands (n = 1) in diameter. Mean (${\pm}SD$) surgical duration was $48.3{\pm}8.5$ minutes (range 35 to 60 minutes). Preoperative and postoperative mean (${\pm}SD$) cranial drawer signs were $8.6{\pm}1.6$ mm (rage 7 to 12 mm) and $1.2{\pm}1.0$ mm (rage 0 to 3 mm) respectively. Immediate postoperative radiographs of the affected limb revealed no evidence of cranial subluxation of the tibial tuberosity in a tibial compression view of 9 dogs. Normal limb function was regained in 8 dogs within 8 weeks postoperatively. A consistent weight bearing lameness resolved in all dogs after TightRope CCL technique, but reoccurred in one dog (case No. 6) 2 weeks after surgery. Cranial subluxation of the tibial tuberosity was identified in a tibial compression test. During the second surgery, breakage of surgical button was identified and a tibial wedge osteotomy was performed. Based on surgical time, complication, stifle stability, and functional recovery, the present study indicated that TightRope CCL technique is effective treatment for the dogs with CCL deficiency.

Low Dose Spinal Anesthesia for Ambulatory Surgery of Varicose Vein (하지정맥류의 외래수술을 위한 저용량 척추마취)

  • Yang, Jin-Sung;Park, Young-Woo;Lee, Jae-Wook;Won, Yong-Soon;Shin, Hwa-Kyun;Lee, Dong-Gi
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.233-237
    • /
    • 2009
  • Background: Bupivacaine with fentanyl might be suitable as the spinal anesthesia for performing ambulatory surgery to treat varicose vein. Material and Method: Thirty patients who underwent spinal anesthesia for a varicose vein operation were enrolled in this study. They were classified into 2 groups of either fentanyl 25ug mixed with bupivacaine 4mg (group FB4) or bupivacaine 8mg (group B8). We compared the groups for the success of the analgesia, the recovery time from sensory and motor block, the side effects and the postoperative complications. Result: The groups did not differ significantly regarding the success of analgesia (13 of 15 [group FB4], 15 of 15 [group B8]). None of the patients were converted to general anesthesia due to surgical pain. None of the patients required medication for hypotension and/or bradycardia. The operative and nonoperative side effects of motor block (tested for by using a modified Bromage scale) was significantly lower in group FB4 than that in group B8, as checked at 2 hours after spinal anesthesia (p<0.05). Recovery from spinal block was significantly quicker in group FB4 than that in group B8 (p<0.05). The first voluntary micturition time did not differ significantly (6.5 hours v 4.5 hours [p=0.143]) between the groups, but a nelatone catheter was inserted into 2 of the group B8 patients due to dysuria. Conclusion: Adequate intraoperative analgesia and hemodynamic stability and faster mobilization were achieved using bupivacaine 4mg with fentanyl 25ug. Low dose spinal anesthesia with fentanyl is suitable for performing ambulatory surgery to treat varicose vein.

A Study on Driving Safety Evaluation Criteria of Personal Mobility (퍼스널 모빌리티(Personal Mobility)의 주행안전성 평가지표 연구)

  • Park, Bumjin;Roh, Chang-gyun;Kim, Jisoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.5
    • /
    • pp.1-13
    • /
    • 2018
  • Divers types of Personal Mobility(PM) are appeared on the market after the Segway is introduced. PMs have propagated very rapidly with their ease of use, and accidents related with PM show a sudden increase. Many studies on the PM are performed as its trend, but dring safety of passengers are excluded. In this study, criteria which can be adopted for PM's driving safety evaluation are reviewed. Also result of driving safety evaluation on 3 types of PM(wheel chair, kickboard, scooter(seating/standing) and walking using deducted criteria is given. COG(Center of the gravity) and SM(Stability Metric) are finally selected two criteria among many of them used in other fields. COG indicates how the center of mass deviates from the direction of the gravity. SM is a normalized value of generated force when PM moves as internal force, angular momentum, and ground reaction force. 0 means stop, and negative value means rollover, so it can be used for safety evaluation of PM. Average and standard deviation of measurement are standard of safety on the COG analysis. Wheel chair is the most safe and kickboard is the most unstable on the COG analysis. Wheel chair is also ranked as top safe on the SM analysis. Among two riding types(seating and standing) on the scooter, seating type is evaluated more safer than standing type. It is proposed that more various type of PMs are need to get safety evaluation for drivers and devices themselves together.