• Title/Summary/Keyword: 안전작동

Search Result 552, Processing Time 0.028 seconds

Measurement of the Device Properties of Photoelectric Smoke Detector for the Fire Modeling (화재모델링을 위한 광전식 연기감지기의 장치물성 측정)

  • Cho, Jae-Ho;Mun, Sun-Yeo;Hwang, Cheol-Hong;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.62-68
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially required for the reliable design of evacuation safety using the fire modeling. The main objective of the present study is to measure input information in order to predict the accurate activation time of photoelectric smoke detector adopted in fire dynamics simulator (FDS) recognized a representative fire model. To end this, the fire detector evaluator (FDE) which could be measured the device properties of detector was used, and the input information of Heskestad and Cleary's models was obtained for a spot-type photoelectric smoke detector. In addition, the activation times of smoke detector predicted using default values into FDS and measured values in the present study were quantitatively compared. As a result, the Heskestad model could result in an inaccurate the activation time of photoelectric smoke detector compared to the Cleary model. In addition, there was a distinct difference between the default values used into FDS and the measured values in terms of device properties of smoke detector, and thus the activation time also showed a significant difference.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

Comparative analysis of status of safety accidents and importance-performance analysis (IPA) about precautions of safety accidents by employment type of industry foodservices in Jeonbuk area (전북지역 산업체급식소 조리종사자의 고용형태에 따른 안전사고 실태 및 안전사고 예방관리에 대한 중요도와 수행도 분석)

  • So, Hee;Rho, Jeong Ok
    • Journal of Nutrition and Health
    • /
    • v.50 no.4
    • /
    • pp.402-414
    • /
    • 2017
  • Purpose: The purpose of the study was to evaluate the status of safety accidents and importance-performance analysis (IPA) between regular and non-regular employees in industry foodservices. Methods: The participants were regular employees (n = 119) and non-regular employees (n = 163) in industry foodservices in the Jeonbuk area. Demographic characteristics, status of safety accidents, safety education, and importance and performance status were assessed using a self-administered questionnaire. Results: Approximately 66.4% of regular employees and 53.4% of non-regular employees experienced safety accidents (p < 0.05). Types of safety accidents of regular and non-regular employees were mostly burns, and causes were mostly from their own negligence. Approximately 98.3% of regular employees and 95.1% of non-regular employees experienced safety education. Approximately 88.9% of regular employees and 96.8% of non-regular employees received safety education from dietitians. Approximately 41.9% of regular employees and 50.0% of non-regular employees had difficulty applying the contents of safety education due to lack of time during work. As a result of IPA, regular and non-regular employees were aware of the importance of the following and performed them well: 'Clean the floor of the work place', 'Arrange in the work area', 'Wear safety shoes', 'Check for heater cord', and 'Safety cooking when using oil'. On the other hand, they were not aware of the importance of the following and performed them insufficiently: 'Check for the MSDS', 'Aware of chemical signs', 'Wear protection gloves etc.', 'Do stretching exercise', and 'Using ancillary tools'. Conclusion: Therefore, it is necessary to improve the consciousness of dietitians for effective application of safety education contents, development of contents, especially MSDS, and related things.

A Study on how to improve Survey of Fire Safety Management of manufacturing plants (The Medium and Small-sized Manufacturing industry) (제조 사업장의 소방안전관리 실태조사 및 개선방안에 대한 연구 (중소규모 제조사업장 중심으로))

  • Choe, Yeong-Gi;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.483-497
    • /
    • 2013
  • 현대사회가 발전 할수록 대량산업화와 도시화가 심화되어 건축물의 초고층화 및 대형화가 증가하고 있으며, 안전적인 건축물 보다는 건물 및 제조사업장의 시각적인 디자인에 치우쳐 화재하중이 높은 건축자재의 내 외장재 및 고급스러운 장식물을 사용함으로써 그 위험뿐 만 아니라 화재발생시 대규모 인명 및 재산상의 피해를 가져오게 된다. 그리고 제조사업장화재는 화재로 인한 직접적인 손실 즉 물적 손실은 물론 생산중단으로 인한 간접적인 손실은 실로 측정하기가 어렵다. 지금까지 발생한 제조사업장화재의 발화요인별 분석은 부주의, 전기적, 미상 순으로 인한 화재가 가장 많고 발화열원은 작동기기, 담뱃불(라이터), 마찰 전도 복사등이 주요 원인이 되고 있고 대형화제 취약시설로는 공장 및 창고로 나타나고 있다. 소방방재청의 통계자료를 살펴보면 2012년 화재 발생현황 중 발화요인에 대한 화재별 장소 건수를 검토 한 결과 비주거의 화재발생 16,009건 중 5,758건으로 (36%)부주의이고, 주거에도 화재발생 10,715건 중 5,560건으로 51.9%의 부주의로 가장 높은 것으로 나타났다. 그러므로 제조사업장의 사소한 부주의로 발생하는 화재를 예방하기 위해서는 소방안전관리자의 처우개선과 기업활동규제완화의 겸직 허용을 재검토 하여야 하며, 소방안전관라자의 실무능력 강화를 위한 소방안전관리 실무교육과정을 이론적 교육 보다는 현장 실습위주로 할 필요가 있다. 이를 위해서는 소방안전관리자에 대한 법정 실무교육 횟수를 확대하여 현행 2년에 1회 에서 1년에 1회로 하고, 실무교육에 있어서도 우수송방안전관리 업체를 선정하여 화재예방에 대한 구체적인 업무를 활성화 하고, 문제 발생요소들을 분석하여 실습을 통한 소방안전관리자의 실무교육을 실시해야 할 것이다. 이러한 전문 소방안전관리자로 소방대상물의 소방교육 및 훈련을 성실히 수행 해야 할 것 이다. 한순간의 부주의로 인하여 화재가 발생하면 돌이킬 수 없는 수백명의 생명을 앗아가고, 수백억원대의 재산피해를 줄이기 위해서는 소방안전관리자의 역량을 넓히고 화재예방 업무를 최우선적으로 수행해야 할 것이다. 화재예방을 위해 소방안전관리자의 업무개선 및 전문교육을 활성화 하여 업무능력을 향상 시켜 화재발생시 초기진압에 신속하고 정확하게 대처해야 한다는 것이 전문적인 화재예방 대책 일 것이다.

  • PDF

Fundamental Rights Reflected by the Legislation Regarding Radiation and Nuclear Power (방사선 및 원자력 관련 법제가 반영하는 기본권)

  • Han, Eun Ok;Lee, Jae Seong;Cho, Hong Jea
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.15-29
    • /
    • 2016
  • Research background: Despite the visible growth in radiation usage and nuclear power development, the analysis of their relationship with fundamental rights, a subject of public concern regarding issues including the right to health, environmental rights, safety rights, the right to know, the right to development, and the right to life, is currently non-existent. Methods: By examining various fundamental rights in the context of positive laws regarding radiation and nuclear power in an idealistic perspective that guarantees the maximum degree of rights, this paper aims to propose legislative supplements that will lead to improvements in quality of life. Result and discussion: In the South Korean Constitution, radiation and nuclear power is a subject incorporating several rights, including at least 12 clauses that are directly related to fundamental rights; these constitutional rights are manifested in the various clauses of the 14 positive laws regarding radiation and nuclear power. The question on the relative importance of each fundamental right as reflected in these positive laws- whether the right to life should be prioritized or considered equal in weight to the right to health, environmental rights, the right to know, and safety rights- requires careful deliberation and is difficult to humanly resolve in the short term. Conclusion: Making policy that expands the usage of radiation and nuclear power while simultaneously preventing their associated risks is an important task for the Republic of Korea, and a proper value judgment is necessary to find a balance in its associated rights.

A Numerical Study for the Atrium Smoke Control by Fire Shutter and Evacuation (방화셔터를 이용한 아트리움 제연과 피난안전에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.50-59
    • /
    • 2010
  • Four fire scenarios, as the cases of fire sizes of 2 MW and 5 MW, and no installation and activation of atrium fire shutter for dormitory building of Daegu 'D college', were developed and fire simulations were run using FDS (ver. 5.5.0) and Pathfinder 2009 programs. By assessing fire and evacuation, the effects of atrium fire shutter and vents on the smoke control of atrium were evaluated and this study also analyzed fire hazard and egress safety for occupants in the dormitory. Fire shutter's preventing smoke transport around atrium was much effective, but smoke layer descended down the design limit of smoke height and kept about 2 m height from the atrium floor in all cases because flow rate through vents was not enough. For the case of 5 MW fire and no fire shutter, fire hazard was higher due to visibility than temperature and allowable egress time to stairwell was short less than 5 seconds for the occupants on the floors of 4F to 7F. For total occupants, egress time out of main doorway was calculated about 136 seconds. It is sure that additional systems improving the performance of smoke control need to be installed for more safe evacuation.

Differences between Each Requirement for Radiation Safety Regulation Levels (방사선안전규제 요건별 인식도 차이)

  • Han, Eun Ok;Cho, Dae Hyung
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.219-225
    • /
    • 2012
  • This study makes differentiated regulations which can maximize the efficiency and convenience of radiation safety regulations by deriving evidence required to establish reasonable safety regulatory structure based on the determination of the levels of actual radiation safety regulations for radiation safety managers to perform radiation safety. We surveyed approximately 10% of radiation safety managers from domestic radiation-using organizations which was based on the Nuclear Safety Act and NUREG Vol. 1~21 of RS-G-1.9 (2005), NRC of IAEA, etc. The radiation safety managers showed the highest level of awareness on the requirements for exposure management ($3.32{\pm}0.910$), and the lowest level on the requirements for record keeping and storage of documents ($2.84{\pm}0.826$). Industrial organizations showed higher levels of awareness than medical organizations whose regulations should be more stringent on requirements of the status and management of radioactive sources, facilities, measurements, pollution control, measuring equipment, monitoring, education and training, and exposure management. This suggests that the actual regulations need to be re-evaluated because it is attributed to the regulations which are statistically significant difference of the levels of radiation safety regulations between industrial organizations and medical organizations. The process of developing regulatory requirements for each characteristic of domestic organizations needs to be done in future studies, as well as safety regulations to maximize convenience should be achieved if radiation safety regulations are conducted in consideration with the characteristics of each organization.

A Study on The Necessity of Establishing an IT-Based Local Government Safety and Health Management Information Integration System (IT 기반 지자체 안전보건 관리 정보 통합 시스템 구축 필요성에 관한 연구)

  • Seo-Yeon Choi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.4
    • /
    • pp.701-708
    • /
    • 2023
  • Local governments are required to take measures to prevent occupational accidents under Articles 4(2) and 4(3) of the Occupational Safety and Health Act, and this study suggested the necessity of establishing an IT-based integrated safety and health information sharing system for serious accident reduction and safety and health management through the case of Incheon Metropolitan City. Recently, as local governments have established labor and health ordinances and basic plans, the need for an independent integrated safety and health management system based on local industrial characteristics has increased. It is necessary to establish a cooperation and support system with basic local governments and hub institutions, share integrated safety and health information with related institutions and organizations, and play a pivotal role in regional safety and health management by managing occupational accident statistics and implementing basic policies. The system through local governments' safety and health management will reduce serious accidents in the region, and the comprehensive safety and health management system for small businesses and projects ordered by local governments will strengthen the operability of the site, which will be effective in preventing critical accidents and industrial accidents.

Design and Test of a 20 kg-class Tilt-duct VTOL Aerial Robot (20 kg급 틸트-덕트 수직이착륙 비행로봇의 설계 및 시험)

  • Chang, Sungho;Cho, Am;Choi, Seongwook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1095-1102
    • /
    • 2016
  • This paper presents the results of the design, fabrication and tether test for a gross weight 20 kg tilt-duct VTOL aerial robot. The tilt-duct vehicle, a tri-ducts air-vehicle, which composed of two main tilt ducts for thrust and an aft-fan for pitch attitude control, has been developed as an aerial platform. The research on the air vehicle has been focused on the hover characteristics and controllability to improve the thrust and stability. The tether test for measuring various performance of vehicle and evaluating controllability have been carried out to figure out effects of modified main-prop linkage, actuator, duct configuration and control surfaces.

A Study on the Development of Overflow Cutoff Valve for Liquefied Petroleum Gas Cylinders (액화석유가스 용기용 과류차단밸브의 개발에 관한 연구)

  • Rhim Jong-Kuk
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.158-161
    • /
    • 2005
  • This research is about overflow cutoff valve for liquefied petroleum gas cylinders. This valve was developed based on Bernoulli's equation and Newton's equation. The structure of overflow cutoff valve was made by insert module instead of the ordinary valve that is used at present. Recently, the increase in use of gas for fuel in houses has resulted to more frequent occurrences of gas related accidents. In Korea, the government has made a law for the obligatory use of the cutoff valves. This cutoff valve is not ya developed. This research focuses on the use of over flow cutoff valve for LPG cylinders. If this valve is adapted, many accidents can be prevented.