• Title/Summary/Keyword: 안전단

Search Result 1,008, Processing Time 0.025 seconds

A Brief Review of the Legal Definition of Chemical Accident under the Current Chemical Substances Control Act (화학물질관리법상 화학사고 정의에 관한 소고)

  • Jihoon Park;Seon-Oh Park;Hyojin Park;Hye-Ok Kwon
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.4
    • /
    • pp.179-182
    • /
    • 2023
  • The Chemical Substances Control Act has been legislated to counter the risks posed by chemical substances to public health and the environment, but a number of small- and large-scaled incidents related to hazardous chemicals continue to occur every year. The Korean Ministry of Environment takes legal responsibility for prevention, preparedness, and response to nationwide chemical accidents under the Chemical Substances Control Act. The determination of chemical accidents that occur during hazardous chemical handling processes is based on the Article 2 (Definitions) of the law and the administrative criteria for judgement of chemical accidents. However, there are certain ambiguities in the scientific basis for determining chemical accidents under the current regulations. Whether or not a chemical accident has a direct influence on penalties and administrative measures for a workplace where an accident occurred, it is necessary to find reasonable criteria for determining chemical accident based on legal and scientific evidence.

체결 및 이탈겸용 4-팁 와셔 부품 설계

  • 김형원;문순일
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.19-19
    • /
    • 1997
  • 휴대용 미사일의 1단과 2단 추진기관은 체결부품에 의하여 연결되어 발사관 내에서 운반되어지며, 발사 시 1단 추진기관이 분리되게 된다. 이때에 분리력은 1단 추진기관의 압력에 의하여 제공되고 체결부품인 4-팁 와셔는 어느 압력 이상을 받으면 추진기관의 1단과 2단을 분리한다. 정적시험을 하여 구한 결과를 해석치 와 비교했으며 실제상황에 유사한 동적 시험을 하여 필요한 안전계수를 구하였다.

  • PDF

A Study on Seismic Performance Evaluation of Road Tunnel according to Seismic Analysis Conditions (내진해석 조건에 따른 도로터널 내진성능평가에 관한 연구)

  • Choi, Byoung-Il;Kim, Chan-Hee;Noh, Eun-Cheol;Ha, Myung-Ho;Park, Si-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.127-134
    • /
    • 2021
  • When constructing a tunnel on a stable ground, stress is changed in the ground during excavation stage and installation of ground support materials. In the standards for safety evaluation of structures in use, it is suggested to perform numerical analysis reflecting the excavation stage. But method of seismic performance evaluation was not presented. Therefore, in this study, numerical analysis was performed with different analysis methods, and the results were compared and analyzed. As a result of the numerical analysis, seismic wave applied in the horizontal direction were no difference depending on the analysis methods. However, there was a big difference in the result according to the evaluation methods of tunnel member forces. When reviewing with the strength design method, the structure performance could be not satisfied depending on the existence or nonexistence of reinforcing bars. Based on these research results, it is suggested that the interpretation method should be clearly presented and reflected in the relevant standards.

Fire and Evacuation Simulation Analysis of Large-Scale Domestic Data Centers (국내 대규모 데이터센터 화재 및 피난 시뮬레이션 분석 )

  • Kim, Dong-Min;Go, Eun-Seong;Park, Hyeong-Gyoon;Gwak, Ji-Hyeon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.347-348
    • /
    • 2023
  • 본 논문에서는 실제 규모 데이터센터의 3D 모델링을 기반으로 대상 공간별 화재 시나리오를 선정하여 화재 및 피난 시뮬레이션을 수행하였다. FDS와 Pathfinder는 full coupling 방식을 사용할 수 없는 한계가 있으며 semi coupling의 경우 가시화에는 도움이 되나 결과에 영향을 주지 않는다. 따라서 재실자의 피난 상황 시 경로에 대한 안전성과 화재 위험 노출 정도를 시각적으로 분석하는 것이 가능한 semi coupling과 시뮬레이션 결과 데이터 분석을 병행하여 수행하였다. 전산실의 경우 서버의 기능상실 한계 온도가 32도이기 때문에 서버 기능 정지 상황에 도달하는 시간을 중점적으로 분석하였다. 전산실은 업무 및 고객 서비스와 관련된 모든 데이터들을 저장하기 위해 항시 기동 되어야 하는데 전산실 내 화재가 발생할 경우 1~2분 이내 서버 기능이 정지되는 상황이 발생하였다. 따라서, 서버가 안전하게 계속 동작하기 위해서는 전력 계측 및 제어 케이블 열화, 서버 장치의 건전성이 유지되어야 하며 초기 화재를 빠르게 감지하여 진압하여야 한다. 피난 시뮬레이션의 경우 가시도를 상실하게 되는 시간이 약 195초(5m 미만) 인근으로 인원이 해당 층을 완전히 벗어나는 데 걸리는 시간이 약 125.6초였던 것을 보면 대피하기에 충분한 허용 피난시간(ASET)을 확보하고 있음을 알 수 있었다.

  • PDF

2004년도 가스사고 현황

  • Korea LPGas Industry Association
    • LP가스
    • /
    • s.95
    • /
    • pp.55-57
    • /
    • 2005
  • -대형사고(1급)는 2년연속 단 한건도 발생치 않아 -안전기기보급,안전공급계약제등 철저한 안전관리 추진결과 -가스보일러에 의한 CO중독사고로 인명피해 증가, 사용자 주의필요

  • PDF