• Title/Summary/Keyword: 안면스캔

Search Result 43, Processing Time 0.017 seconds

Effects of wax rim in image registration of intraoral and face scan in edentulous arch condition (무치악 악궁에서 구강과 안면 스캔의 정합을 위한 왁스림의 활용 효과)

  • Sang-Hyeok Seo;Cheong-Hee Lee;Kyu-Bok Lee;So-Yeun Kim;Du-Hyeong Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.135-141
    • /
    • 2024
  • Purpose: The purpose of this study was to investigate the accuracy of image merging of an intraoral scan of an edentulous arch to a facial scan using wax rim and markers. Materials and Methods: For registration of oral scan to face scan, a wax rim with markers was made. The markers were cuboid and divided into four groups according to size (5, 10 mm) and attachment location (midline, canine region). The evaluation of registration accuracy was compared with a standard created using cone-beam computed tomography data. Anterior linear variation of the edentulous arch and the 3D variation of the overall arch were measured. Kruskal-Wallis test and Mann-Whitney U test were used for statistics, and the significance level was set at 0.05 and evaluated under Bonferroni correction (0.05/6 = 0.083). Results: In the anterior deviation and global deviation results, there was no statistically significant difference in the oral scan position displacement values between the 5 mm and 10 mm groups. When the midline marker was used, the intraoral scan position displacement value was significantly lower than when only the canine marker was used. Conclusion: Marker attached wax rim can be used for image matching between facial and intraoral scans of the edentulous arch. Marker location at the middle area increases the accuracy of image matching.

Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: A case report (심미보철 수복을 위한 3차원 안면스캔과 가상 보철물 시각화를 이용한 디지털 치료 증례)

  • Mai, Hai Yen;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.425-431
    • /
    • 2019
  • This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Influence of the angles and number of scans on the accuracy of 3D laser scanning (3 차원 레이저 스캔영상 채득 시 스캔각도와 횟수에 따른 정확도)

  • Lee, Kyung-Min;Song, Hyo-Young;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.76-86
    • /
    • 2011
  • Objective: To investigate whether the accuracy of 3D laser scanning is influenced by the angles and number of scans. Methods: Using a 3D laser scanner, 10 manikins with facial markers were scanned at 7 horizontal angles (front view and at $20^{\circ}$, $45^{\circ}$, and $60^{\circ}$ angles on the right and left sides). Three-dimensional facial images were reconstructed by 6 methods differing in the number and angles of scans, and measurements of these images were compared to the physical measurements from the manikins. Results: The laser scan images were magnified by 0.14 - 0.26%. For images reconstructed by merging 2 scans, excluding the front view; and by merging 3 scans, including the front view and scans obtained at $20^{\circ}$ on both sides; several measurements were significantly different than the physical measurements. However, for images reconstructed by merging 3 scans, including the front view; and 5 scans, including the front view and scans obtained at $20^{\circ}$ and $60^{\circ}$ on both sides; only 1 measurement was significantly different. Conclusions: These results suggest that the number and angle of scans influence the accuracy of 3D laser scanning. A minimum of 3 scans, including the front view and scans obtained at more than $45^{\circ}$ on both sides, should be integrated to obtain accurate 3D facial images.

Using dental virtual patients with dynamic occlusion in esthetic restoration of anterior teeth: case reports (동적 교합을 나타내는 가상 환자의 형성을 통한 심미적인 전치부 보철 수복 증례)

  • Phil-Joon Koo;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.328-343
    • /
    • 2023
  • Recently, a method of fabricating an esthetic anterior fixed prosthesis by integrating data such as three-dimensional facial scan and jaw motion to form a virtual patient with dynamic occlusion has been introduced. This enables smooth communication with patients during the diagnosis process, improves the predictability of esthetic prosthetic treatment, and lowers the possibility of occlusal adjustment. In this case report, a virtual patient with dynamic occlusion was created in which the results of the treatment were simulated, and esthetic maxillary anterior fixed prosthesis was fabricated. With the aid of the virtual patient, the final restorations were satisfactory both in terms of esthetic and function.

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

3-step digital complete denture restoration using facialscan: a case report (안면 스캔을 이용한 3회 내원 디지털 총의치 수복: 증례보고)

  • Yeongseok Kwon;Seoung-Jin Hong;Janghyun Paek;Ahran Pae;Hyeong-Seob Kim;Kung-Rock Kwon;Kwantae Noh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.356-366
    • /
    • 2023
  • Support, retention, and stability of dentures are key factors in the use of complete dentures in edentulous patients. With the development of digital dentistry, attempts are being made to replace traditional treatment methods. Also, struggle to reduce the number of patient visits and to manufacture high-quality digitally fabricated dentures are ongoing. In this case, a digital denture was restored using a tray capable of obtaining centric relation through gothic arch tracing and a facial scan. By replacing the traditional complete denture restoration method, the number of patient visits was reduced and esthetic results with satisfactory denture support, retention, and stability were obtained.

Aesthetic restoration n patients with unaesthetic maxillary anterior teeth using double scan : A case report (비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례)

  • Ko, Chang Woo;Kim, Min-Ji;Yang, Hong-So;Park, Sang-Won;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • In case of the treatment of maxillary anterior teeth, it should be taken into account the proper morphology, arrangement and color satisfying patient's esthetic demands. For this purpose, facial composition, dentofacial composition, dental composition and dentogingival composition should be considered making diagnosis and treatment plan in an esthetic point of view. In adjustable temporary crown state, careful evaluation and correction of the esthetic and functional aspect were performed, and the definite restoration was reproduced using double scan.

Quantification of Salivary Gland Scan Image and its Correlation with Salivary Flow Rate (타액선 스캔의 정량적 분석과 타액분비율과의 상관관계에 관한 연구)

  • Kim, Sung-Hun;Kim, Youn-Joong;Chung, Sung-Chang
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.3
    • /
    • pp.215-224
    • /
    • 2001
  • 서울대학교 치과병원 구강진단과에 구강건조증을 주소로 내원한 환자중 비자극 전타액 분비율이 0.2ml/min이하인 환자 40명과 구강건조증의 증상 및 징후가 없고 정상 타액분비율을 보이는 10명을 대상으로 비자극 전타액 분비율을 측정하고 타액선 스캔 검사를 실시하여 주타액선의 스캔 영상을 정량화한 후 이의 상관관계를 조사한 결과 다음과 같은 결론을 얻었다. 1. 구강건조증 환자군 및 정상 대조군에서 타액선 스캔 영상의 정량적 분석시 이하선 및 악하선 모두에서 좌우측 사이의 유의성 있는 차이가 없었다. 2. 타액선 스캔 영상의 정량적 분석시 구강건조증 환자군은 대조군에 비하여 악하선, 이하선 및 악하선의 합, 양측 악하선 합에서 유의한 차이를 보였다. 3. 대조군에서 타액선 스캔 영상의 정량적 수치와 비자극 전타액 분비율과는 유의성 있는 상관관계가 관찰되지 않았으나, 구강건조증 환자군에서는 유의성 있는 상관관계가 관찰되었다. 4. 구강건조증 환자군을 비자극성 전타액 분비율에 따라 세분하였을 때, 비자극 전타액 분비의 감소가 극심하여 그 측정이 불가능하였던 군은 대조군 및 나머지 구강건조증 환자군에 비하여 타액선 스캔 영상의 정량적 수치에서 유의한 차이를 보였다.

  • PDF

Application of various digital technique on full mouth rehabilitation: A case report (디지털 기술을 활용한 전악 고정성 보철 수복 증례)

  • Bae, Min-Soo;Song, Kwang-Yeob;Ahn, Seung-Geun;Park, Ju-Mi;Lee, Jung-Jin;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.43-54
    • /
    • 2021
  • Based on rapid improvement in digital fields, many advanced digital technologies are utilized in prosthodontic treatment. Especially, intraoral scanners and 3D printing technology are commonly used, and facial scanning technology is recently being attempted to be part of these digital routines. This case report aims to introduce a digital procedure using the intraoral scanner, facial scanner, and 3D printing technology to create definitive restorations, which are esthetic and harmonious with patient's face. From thoroughly evaluated full-mouth provisional restoration which was manufactured and fitted conventionally, definitive prostheses were fabricated using various digital technique. Stable occlusion with functionally and aesthetically satisfying results were achieved.