The Effects of Interrelationship after Wearing between Respirators and Glasses Simultaneously (안면부 여과식 방진 마스크와 안경 동시 착용 시 상호 영향)

  • Eoh, Won Souk;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2018
  • This study compares the interrelation of fit factor(FF) and visual acuity test by the order of wearing preference between Particulate filtering face piece respirators(PFFR) and glasses for 54 participants. Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA) or Visual acuity. We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038 and compared the result of preference of wearing order between respirators and glasses. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis, peason correlation(P=0.05) Fit factor was increased when the respirator was worn before wearing the glasses(p=0.000) and decreased for visual acuity(p=0.000) The negative correlation was showed between OH and Overall fit factor(r=-0.409, p=0.002). Among 54 participants, 11 participants(20.3%) were worn respirator before wearing glasses and 1 participant(1.9%) was worn glasses before wearing respirator. The overall fit test showed the higher level was investigated for the group of participants wearing respirator before wearing glasses in 6 exercises. Also, overall fit factor were increased when participants wore glasses prior to respirator(16.6) to respirator prior to glasses(36.6). Visual acuity were increased when participants wore respirator prior to glasses(93.8) to glasses prior to respirator(106.0). Finally, comparison result of overall fit factor and visual acuity were glasses first choice from mask first choice. The results showed that higher overall fit factor was investigate when the participants wore the respirator prior to glassess at all. The results implied that it is important to maintain the overall fit factor and visual acuity according to the consideration of OH for glasses fitting when worker wore respirator and glasses at the same time.

Blood Gas Analysis of Respiratory Depression during Sevoflurane Inhalation Induction for General Anesthesia in the Disabled Patients (장애 환자의 전신 마취를 위한 세보플루란 흡입 유도 시 발생한 호흡 저하의 혈액 가스 분석)

  • Yoon, Taewan;Kim, Seungoh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.508-513
    • /
    • 2018
  • Tidal volume by sevoflurane in small amounts is stable due to the increase in the breathing rate. But alveolus ventilation decreases due to sevoflurane as the degree of sedation increases; this ultimately causes $PaCO_2$ to rise. The occurrence of suppression of breath increases the risk of severe hypoxia and hypercapnia in deeply sedated patients with disabilities. Sevoflurane inhalation anesthesia has a number of risks and may have unexpected problems with hemodynamic changes depending on the underlying state of the body. This study was conducted to examine the stability of internal acid-base system caused by respiratory depression occurring when patients with disabilities are induced by sevoflurane. Anesthetic induction was carried out by placing a mask on top of the patient's face and through voluntary breathing with 4 vol% of sevoflurane, 4 L/min of nitrous oxide, and 4 L/min of oxygen. After the patient's loss of consciousness and muscle relaxation, IV line was inserted by an expert and intravenous blood gas was analyzed by extracting blood from vein. In a deeply sedated state, the average amount of pH of the entire patients was measured as $7.36{\pm}0.06$. The average amount of $PvCO_2$ of the entire patients was measured as $48.8{\pm}8.50mmHg$. The average amount of $HCO_3{^-}$ of the entire patients was measured as $27.2{\pm}3.0mmol/L$. In conclusion, in dental treatment of patients with disabilities, the internal acid base response to inhalation sedation using sevoflurane is relatively stable.

Efficacy and Usability of Patient Isolation Transport Module for CBRN Disaster : A Manikin Simulation Study (특수재난 대응 환자 격리 이송 장비의 효율성 및 편의성 평가: 마네킹시뮬레이션 연구)

  • Kim, Ki-Hong;Hong, Ki-Jeong;Haam, Seung-Hee;Choi, Jin-Woo
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • In Chemical, Biological, Radiological and Nuclear (CBRN) disaster, integrated and optimized equipment package including stretcher, isolation unit, patient monitoring and treatment equipment is essential to achieve proper treatment and prevent secondary contamination. The purpose of this study was to evaluate the efficiency and ease of use of integrated CBRN disaster equipment package for disaster medical response. This study was a randomized crossover study using a manikin simulation for emergency medical technitian (EMT). All participants used the existing devices and prototype of integrated CBRN disaster equipment package alternately. Efficiency was measured by time from vital sign change to detection or treatment application. Ease was use was measured by questionnaires for each patient monitor, stretcher care and isolation unit. 12 EMTs were enrolled. hypoxia-detection time of integrated equipment group was significantly shorter than existing equipment group (4.9 s (3.8-3.9) vs 3.5 s (2.5-3.9), p < 0.05). There was decreasing tendency of ECG change detection and facial mask oxygen supply but no statistical significance was observed. Overall satisfaction of patient monitoring device in integrated equipment group was significantly higher than existing devices (4(3.5-5) vs 3(3-3), p < 0.05). The use of integrated CBRN disaster equipment package shortened the hypoxia detection time and improved usability of vital sign monitor compared to existing devices.

Effect of Intravenous Administration of Tramadol on the Minimum Alveolar Concentration of Isoflurane in Dogs (개에서 트라마돌의 정맥투여가 아이소플루란의 최소폐포농도에 미치는 영향)

  • Seok, Seong-Hoon;Park, Se-Jin;Lee, Seung-Yong;Jin, So-Young;Kim, Young-Ki;Hwang, Jae-Min;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.308-312
    • /
    • 2015
  • This study was aimed to evaluate the effects of tramadol hydrochloride on the minimum alveolar concentration of isoflurane ($MAC_{ISO}$) in dogs. Six healthy, female German shepherd dogs (aged 1-2 years) were used in this study. Anesthesia was induced by mask induction and maintained with isoflurane in oxygen. Mechanical ventilation maintained the end-tidal $CO_2$ partial pressure ($P_{ET}CO_2$) from 35 to 45 mmHg throughout the study. A baseline $MAC_{ISO}$ ($MAC_{ISO}B$) was determined starting 45 minutes after induction of anesthesia by clamping a pedal digit until gross purposeful movement was detected. After $MAC_{ISO}B$ determination, dogs received a tramadol loading dose of 3 mg/kg followed by a continuous rate infusion (CRI) of 2.6 mg/kg/h. The determination of $MAC_{ISO}$ after administration of tramadol ($MAC_{ISO}T$) began 20 min after the start of the CRI. Arterial blood pressure and heart rate were recorded continuously and arterial blood samples for blood gas analysis were collected at the end of the equilibration period. Mean ${\pm}$ SD values for the $MAC_{ISO}B$ and $MAC_{ISO}T$ were $1.33{\pm}0.04%$ and $1.23{\pm}0.04%$, respectively. The $MAC_{ISO}B$ decreased significantly by $7.5{\pm}0.2%$ (P < 0.05) after administration of tramadol. The mean heart rate and arterial blood pressure of six dogs were not changed significantly after tramadol administration. The blood gas levels remained constant during the study. In conclusion, tramadol could significantly reduce $MAC_{ISO}$ without depression of cardiorespiratory function. Thus, the use of tramadol on inhalation anesthesia with isoflurane in dogs can improve the stability of anesthesia and the quality of recovery.