• 제목/요약/키워드: 안경착용

Search Result 189, Processing Time 0.024 seconds

Model on the Elastic Behavior of Spectacle Frame (안경테 및 의료용구에 관한 연구 - 안경테의 탄성해석에 관한 모델 -)

  • Kim, DaeSoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.127-138
    • /
    • 2000
  • Differential equations and their solutions were formulated to describe the deflection of both temples and front frames and the pressure exerted by them varying parameters such as elastic modulus, thickness, length, width and shape of crosssection. The effect of such parameters on the deflections of both temples and front frames was illustrated by plotting the solutions of the derived equations. Deflection of temples was found to be maximum where the cross section was diamond-shaped and to be minimum with the rectangular cross section while thickness and cross section area of temples remain constant. The effect of parameters consisting of front frame on the deflection of front frames are very similar to those on temples. The central deflection and pressure of front frame initiated by the temple decreases as the length of temple increases. Detailed analysis of stresses at various parts of the temple will help design custom made spectacle frame as well as most comfortable frames.

  • PDF

The Change of Accommodative Functions by Difference Density and Color (착색렌즈의 농도와 색상에 따른 조절기능 변화)

  • Jang, Jung Un
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.453-459
    • /
    • 2018
  • Purpose : This study was to investigate the change of accommodative functions by different color density and color of colored lenses. Methods : Participant had a normal NPC and no dyschromatopsia, phoria and eye disease, also had no histories of eye surgery in 31 students of university. Their accommodative functions were measured according to 50%, 80% density of the gray, blue, brown lens and non-colored lenses. Tests of accommodative functions performed include amplitude of accommodation, accommodative facility, relative accommodation, and accommodative lag. Results : The amplitude of accommodation and accommodation lag were increased when wearing the colored lens. Negative relative accommodation was more increased when wearing the colored lens than achromatic. Positive relative accommodation increased when wearing the blue color lens density by 50%. Also, accommodation facility increased when wearing the colored lens, but, as the density of the color increased, the accommodation facility was decreased. Conclusion : As since the accommodation function changes according to density of the colored lenses, working distance and environment of the wearing colored lens should be considered when selecting density and color of colored lenses.

A Study on Reading Pupillary and Distance Between Optical Centers suitable for Korean (한국인 체형에 적합한 근용안경의 광학중심간 거리에 대한 연구)

  • Youk, Do-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.37-45
    • /
    • 2003
  • This study investigated that total 1071 reading glasses wearers (male 432, female 639) without any eye disease or deformation in eyelid, orbit, eyeball (over 50 years old), were tested. Reading pupillary distance of 524 (male 202, female 322) of 1071 were examined and reading glasses power was examined for all 1071 patients. As a result of average reading diopters analysis by sex. male had S+2.34Dptr, female had S+2.23Dptr in average and male had a little more average power than female by 0.11Dptr. However, the difference was not much enough and by aging accommodation reduction changes were applied to both male and female. After dividing ready-made reading glasses on sale in optical shops into 5 groups by F.P.D. the average D.B.O.C(distance between optical centers) of each 5 group was examined (1st group 64.04 mm, 2nd group 66.96 mm, 3rd group 68.28 mm, 1th group 62.03 mm, 5th group 72.00 mm : the average of all groups was 66.96 mm : each group included 3 random samples : 195 ready-made reading glasses were measured), and compared with the average reading P.D of males and females (male 60.04 mm, female 58.23 mm). The result showed D.B.O.C of ready-made reading glasses on sale was bigger than the average reading P.D of them. The result reviewed the average range for male was $0.23{\Delta}(minimum){\sim}5.06{\Delta}(maximum)$, and for female was $0.46{\Delta}{\sim}5.79{\Delta}$. In conclusion when wearing ready-made reading glasses, female got more effected by average $0.45{\Delta}$ because reading P.D of female was smaller than that of male.

  • PDF

Comparison of Induced Aniseikonia with Influential Factors (영향인자에 따른 유발 부등상시도의 비교)

  • Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.45-51
    • /
    • 2013
  • Purpose: This study was performed to provide indicator of expected aniseikonia by correcting refractive error and to investigate influential factors on aniseikonia. Methods: 20 college students (14 males, 6 females, a mean age of $22.50{\pm}2.72$ years) were selected as subjects whose refractive error with spherical equivalent were within ${\pm}0.50$ D, corrected visual acuity were more than 1.0, and aniseikonia values by AWAYA were less than 1%. After correcting refractive error with spectacles in anisometropia induced by wearing contact lens on their dominant eye or non-dominant eye, practical measured values of aniseikonia were compared with theoretical expected values of it by the formula of spectacle magnification. Results: Practical measured values were higher than theoretical expected values in induced aniseikonia over the whole range of diopter of wearing contact lens. And there was higher measured value of aniseikonia in case of higher diopter of wearing contact lens to induce anisometropia and correcting refractive error with spectacles of (+) diopter after wearing contact lens of (-) diopter to induced anisometropia in dominant eye of women. Conclusions: It is considered that dominant eye plays more important role for visual function in induced aniseikonia and factors such as the induced eye of aniseikonia, the diopter of wearing contact lens, and gender have influenced on aniseikonia.

A Study of Eye Refraction state on old Age (노안의 굴절이상과 안경착용에 대한 연구)

  • Kim, Jin-Koo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.81-84
    • /
    • 2001
  • This study can provide the accurate information on the treatment of visual acuity of a old ages by test of eye refraction state. The test was performed the visual acuity test by the object methods, and subjects was the over 45 old age. The eye types were 12% positive for emmetropia, 19% for myopia. and 69% for hyperopia, respectively. The abnormal refraction eyes were 3% positive for simple myopic astigmatism, 16% for myopic astigmatism, 14% for simple hyperopia, 5% for simple hyperopic astigmatism, 62% for mixed astigmatism, respectively. The axis of astigmatisms were 72% positive for against-the-rule astigmatism, 21% for with-the-rule astigmatism, 7% for ablique astigmatism, respectively.

  • PDF

The Effect of Physical and Chemical Stimuli on Ophthalmic Lens Coatings (물리적, 화학적 자극이 안경 렌즈의 코팅에 미치는 영향)

  • Kim, So Ra;Kim, Ji Yoon;Kim, Ka Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.237-245
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether certain repeated physical and/or chemical stimuli added on ophthalmic lenses might induce any changes of the functions of lens coatings. Methods: The changes in lens surface, light transmittance, foggy duration, durability of ophthalmic lenses were determined after the application of tearing-off with tape, rubbing with acetone, soaking in acetone or distilled water of ophthalmic lens (CR-39 material) as physical and/or chemical stimuli. Results: The change of ophthalmic lens surface was detected after soaking in acetone for longer than 30 minutes by observing the lens surface to figure out the functional change of hard coating. The ophthalmic lens soaked in distilled water for 180 minutes showed little functional change of anti-reflection coating as 1% by measuring light transmittance of lens. However, the function of anti-reflection coating was almost disappeared after the ophthalmic lens was soaked in acetone for 60 minutes. The foggy duration of ophthalmic lens soaked in acetone was increased by estimating foggy duration of lens. The lens coating was shown to be defected when the pre-damaged ophthalmic lenses were torn off with tape, rubbed with acetone and soaked in distilled water or acetone by observing pre-damaged lens surface to evaluate its durability. Conclusions: The careful management during ophthalmic lens dispensing or usual eyeglass wearing is needed since the change in ophthalmic lens coatings was shown by repeated physical and/or chemical stimuli.

The morphological study of Cornea in Man College Students (남자대학생들의 각막 형태 연구)

  • Kim, Douk Hoon;Yoo, Jae Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.89-93
    • /
    • 2002
  • The physiology and morphology of cornea has effected on the ocular refractive status. Therefore the measurement of the anterior corneal surface by keratometer is used the treatment of the spectacles and contact lens by optician, optometrist, and ophthalmologist. Furthermore, currently the most corneal topographic mapping system have used the clinical optical shop, eye research center, and eye hospital. Because this method have a very fine data comparative to the previous instrument. The authors have measurement the cornea of the man college students by the corneal topographic mapping method. Especially this data will applied the clinical practice for the contact lens fitting. Especially in Korea, many man college students use the contact lens for the visual acuity and a beauty. Therefore the contact lens wear have increase per every year.

  • PDF

Development of Gas-mask Spectacles (방독면 안경 개발)

  • Lee, Jeung-Young;Parkm Jeong-Sik;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.9-12
    • /
    • 2008
  • Purpose: Current gas-mask is very uncomfortable structure for spectacles wearer. Improving this problem can aid military men and firemen to protect themselves and rescue other person. Methods: we changed the structure from dual type of outward lens and inward lens into a single type structure. we attached acrylic frame to gas-mask instead of outward lens and protected the gas inflow by shutting the gab of lens and frame using silicon shield, and made the frame "S" style for removing astigmatism and maintaining of vertex distance. Results: It was possible to correct visual acuity and gas shield, and could changed the lens like a common spectacles. The new type of gas-mask spectacles could remove 0.53D~1.78D astigmatism occurred from the slant of eyesight and lens surface, 0.07D~0.66D overcorrection occurred from short vertex distance, and 0.1D~0.3D astigmatism occurred from pantoscopic angle. Conclusion: Because new type of gas-mask spectacles had clear visual field, it was expected to improve fighting power and rescue ability.

  • PDF

The Visual Acuity and Refraction on Students of Primary School Using Eyeglasses in Kyung-Nam Region (경남지역 안경 착용자 초등학생들의 시력과 굴절)

  • Kim, Douk-Hoon;Mun, Joung-Hak;Kim, Joung-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.345-350
    • /
    • 2006
  • The study of the visual acuity and refraction status was performed to the students of primary school using eyeglasses in Kyung Nam region, Korea. Two hundred sixty three subjects with various styles of ametropia were analyzed the visual acuity and refraction examination by the subjective and objective tools. The results of study were as follows; 1) According to the increase of age of subjects, the visual acuity of binocular in naked eyes was decrease. However ametropia was increase. 2) The high frequency of ametropia types in the binocular was simple myopia, and the next order of high frequency was mixed astigmatism, myopic compound astigmatism, simple hyperopia, and hyperopic compound, respectively. 3) On the power of spherical refractive error of ametropia, the high frequency was -1.00 diopter, and the next order of high frequency was -2.00 diopter, +2.00 diopter, -3.00 diopter, and so on, respectively. 4) According to the increase of subjects ages, the changes of dioptric power of myopic spheric power was increase. however the frequency of the boy and girl was similar results, also the dioptric values of refractive status in binocular was similar results. As the results of this study, we conclude that the relationship of the visual acuity and refractive error status in primary students using eyeglasses was improved.

  • PDF

A Study on the Detection of Axis-Rotation in Contact Lenses (콘택트렌즈 회전량 검출에 대한 연구)

  • Lee, Dong-Hee;Kim, Jung-Hee;Cha, Jung-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.255-259
    • /
    • 2005
  • When we wear contact lenses for correcting astigmatism, we often experience the axis-rotation of contact lenses that is happened in case we could not fit the axis of lens exactly or by the eyelid used to blink. In this case, because the exact correcting state becomes in the wrongly correcting state, the asthenopia is led, and the decline of eyesight can be led. For this reason, we need to know axis-rotating degrees of contact lenses. If a contact lens rotated, a residual astigmatism may be detected in the refraction examination after wearing. Using this, we developed a program that calculates the axis-rotating amount of contact lenses.

  • PDF