• Title/Summary/Keyword: 악취성 화합물 가스분석

Search Result 6, Processing Time 0.026 seconds

Quantification of Odorants from Animal Husbandry using Solid-phase Microextraction (고상(固相) 미세 추출법에 의한 축산 관리시설에서 발생하는 악취성 가스 화합물의 정량적 평가)

  • Kim, Jae-Hyuck;Choi, Hong-Lim;Kown, So-Young;Lim, Hong-Lae;McConnell, Laura L.;Arispe, Susana;Park, Chul-Hwi;Kim, Hyun-Ook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.158-164
    • /
    • 2006
  • Offensive odor from CAFO(concentrated animal feeding operation) and its control have become a significant issue in Korea. Control of odors from the CAFO requires to identify major odorant and their generation mechanisms. In this study, an easy method to collect gas sample and to quantify its odorants is proposed. The method involves on-site odorant extraction with solid-phase microextraction and quantitation with GC/MSD or GC/FID. Analytes of the current study include: trimethylamine(TMA), carbon disulfide($CS_2$), dimethyl sulfide(DMS), dimethyl disulfide(DMDS), acetic acid(AA), propionic acid(PA) and n-butyric acid(BA). The resulting linearity($R^2$) of calibration curve for each analyte was good over the range from several ppbv to ppmv; 0.984 for TMA(0.056-1.437), 0.996 for $CS_2$(0.039-0.999), 0.994 for DMS(0.029-0.756), 0.995 for DMDS(0.024-0.623), 0.992 for AA(0.068-1.314), 0.955 for PA(0.047-0.940), and 0.976 for BA(0.036-0.712). Method detection limits were 5.67, 6.39, 5.78, 25.2, 0.098, 0.363 and 0.099 ppbv for AA, PA, BA, TMA, DMS, $CS_2$, and DMDS, respectively. With the developed method, odorants from poultry, swine, and cattle barns were analysed. All the compounds but DMDS were detected from the sample collected in the poultry barn, and their levels exceeded the representative published human olfactory threshold.

A Study on the Coating Method of Platinum based Catalyst for Odor Gas and VOCs Oxidation (악취가스 및 휘발성 유기 화합물 산화를 위한 백금계 촉매의 코팅 방법에 관한 연구)

  • Shin, Jung Hun;Jung, Min Gie;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.32 no.5
    • /
    • pp.497-503
    • /
    • 2021
  • In this study, different methods to coat honeycomb and metal foam substrate with platinum/titania for removing odor gases and volatile organic compounds were investigated. Among them, the powder coating and the nano coating were compared. Scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX) analysis was used to investigate the surface conditions and exposed platinum composition ratios on honeycomb and metal foam. Also, the catalytic oxidation performance of toluene, trimethylamine and isopropyl alcohol was compared according to the coating method.

Heat Effects for the Volatile Organic Compounds emitted from Garlic and Kimchee (열처리가 마늘과 김치에서 발생되는 휘발성 유기화합물에 미치는 영향)

  • 김병순;양성봉
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.615-622
    • /
    • 1998
  • The volatile organic compounds(VOCs) emitted from raw garlic and Kimchee were analyzed with thermal desorption or purge & trap/gas chromatography/mass selective detection method. Very offensive compounds such as methyl allyl sulfide, dimethyl sulfide, dimethyl disulfide, diallyl sulfide, methyl allyl disulfide, diallyl disulfide and dimethyl trisulfide were detected, and among them, dimethyl disulfide and dimethyl trisulfide were confirmed to be generated during the precocity of Kimchee or emitted from the stuff of Kimchee other than the garlic. Malodorous compounds emitted from the garlic or Kimchee were detected in the breath of a Korean and the refregirator keeping Kimchee. It was confirmed that the disufides emitted from the garlic or Kimchee were major components of offensive odor in the alveolar air and the refregirator. It was clarfied that heat process is very effective to reduce odorous VOCs in garlic or Kimchee.

  • PDF

Characterization on Air Pollution of Gunpo City by Measurement of VOCs in Air (대기중 휘발성 유기화합물 측정을 통한 군포시 대기 오염 특성 규명)

  • Park, Hyun-Mee;Kim, Jee-Hyuon;Park, Il-Yong;Kim, Young-Man;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.556-566
    • /
    • 2002
  • Gunpo city, a medium sized city formed with a basin is populated with a little more than 270,000 peoples and includes the industrial area with about 600 factories. It has been recognized for a long time that peoples living nearby industrial area have complained on serious air contamination due to the geographical and environmental factors. This study was performed on measurement of volatile organic compounds (VOCs) and malodor for the air sampled in various places of Gunpo city, and made comparison with VOCs levels in specific area of Seoul. This work would play important role for the efficient management of air contamination of Gunpo city. Samplings were done in the rooftop of eleven village office buildings including Gunpo station in June 12th, 2001. Analytical results indicate that VOCs levels of Gunpo-1-dong, Gunpo station and Kumjungdong regions neighboring industrial area were much higher than the rest of areas, and this fact shows that the origin for air contamination of Gunpo would be industrial area than car exhaustion gases.

Simultaneous Analyses for Trace Multi-Odorous and Volatile Organic Compounds in Gas using a Triple-bed Adsorbent Tube (Triple-bed Adsorbent Tube를 이용한 가스상 극미량 복합 악취 및 휘발성 유기화합물의 동시 분석)

  • Seo, Yong Soo;Lee, Jea Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.244-252
    • /
    • 2010
  • The objective of this study is to assess feasibility of simultaneous analysis for trace multi-components odorous and volatile organic compounds using a Triple-bed adsorbent tube with a thermal desorber and GC-MS. Triple-bed adsorbent tube is 3 bed packed Tenax-TA with small amount of Carbopack B and Carbosieve SIII in order of adsorption strength in a tube. The operating conditions of GC-MS was possibly able to and effectively detect high volatile and low molecular weight compounds at the mass range of 20~350 m/z using a below impurity 1ppm of Helium carrier gas, of which quantitatively analyzed by target ion extracts. According to the experiment, $C_1{\sim}C_5$ of 14 components; sulfur containing compounds(2), ketones(2), alcohols(4) and aldehydes(6) were simultaneously analyzed with recoveries of 99%, and good repeatability and linearity. High volatile and low molecular weight compounds such as methyl alcohol and acetaldehyde can be safely quantified with high recovery at a condition of 50mL/min of flow rate, below 2L of adsorption volume, and 45% of relative humidity. Target ion extract can also simultaneously quantify multicomponents with odorous and volatile organic compounds in an occasion of piled up two peaks.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF