• Title/Summary/Keyword: 악취성분

Search Result 130, Processing Time 0.028 seconds

Analysis of 111 VOCs using SPME-GC/MS (SPME-GC/MS에 의한 111종 VOCs 분석법 확립)

  • 김대원;허귀석;유혜경;홍진희
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.344-345
    • /
    • 2001
  • 대기 중에는 ppb 수준의 매우 미량으로 많은 VOC 성분이 존재하고 있어 이를 효과적으로 신속하고 적은 비용으로 분석할 수 있는 분석할 필요성이 커지고 있다. 그러므로, 본 연구에서는 대기중의 VOC성분을 SPME-GC/MS법을 이용하여 효율적으로 분석하기 위한 분석법을 개발하고자 하였다. 유해성이 큰 halocarbon, aromatic, haloaromatic V()Cs 42 종(USEPA TO-14)과, 오존을 유발시키는 오존전구물질 VOCs 53 종, 국내 규제 VOCs 33종, 그리고 악취물질(국내 8종 포함 일본 악취물질 22종)을 전부 포함하는 111종의 VOC를 SPME-GC/MS를 이용하여 신속하게 정성, 정량분석할 수 있는 방법을 확립하고저 하였다. (중략)

  • PDF

Development of certified reference materials for odorous aldehyde (알데하이드 악취물질의 인증표준물질 개발)

  • Kim, Young-Doo;Woo, Jin-Chun;Bae, Hyun-Kil;Kim, Byoung-Moon;Lee, Byung Gil;Heo, Gwi Suk
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.14-19
    • /
    • 2008
  • Among the many odor materials, aldehyde has bad influences not only on human nose, but also on human health. Aldehyde has a strong odor at infinitesimal level, such as down to ppt concentration. Also aldehydes are highly reactive and have poor stability. Therefore, manufacture of standard gases, analysis of aldehydes are very difficult compare to other air pollution analysis. Aldehyde CRM containing 4 different aldehydes at $10{\mu}mol/mol$ (ppm) is developed by using gravimetry method according to ISO 6142 guide. The standard gases were reproduced again, and examined its reproducibility of preparation by GC-FID. The developed aldehyde CRM's certified value showed a relative expanded uncertainties of 2.11 % (95 % of confidence level, k=2).

Removal of Offensive Odor in Fermentation Compost Process (퇴비화 공정의 발효상에서 악취제거)

  • Hong, Young-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.652-654
    • /
    • 2009
  • 퇴비화는 유기물질이 분해되는 조건에 따라 호기성 퇴비화(Aerobic composting)와 혐기성 퇴비화(Anaerobic composting)로 대별된다. 음식물쓰레기 퇴비화 시설의 주요공정은 선별시설, 혼합 및 발효시설, 불순물제거장치, 숙성시설, 악취제거시설로 구성된다. 본 과제에서는 이와 같이 음식폐기물 처리공정 등에 널리 사용되는 퇴비화 공정에서 발생하는 악취를 제거하기 위한 연구를 진행하였다. 본 연구에서는 다양한 형태의 탈취 공정을 비교 검토하였으며, 세라믹 담체를 사용한 생물학적 처리에 초점을 맞추어 연구를 진행하였다. 이를 위하여 퇴비화 온도에 따른 유기물의 변화와 NaCl의 농도변화를 측정하여 퇴비화 진행에 따른 성분 변화를 예측하였다.

  • PDF

The Analysis of Ammonia Spatial Distribution of Ammonia at Paper Mill Using Passive Sampler (암모니아 Passive Sampler를 이용한 제지공장 내 암모니아 공간분포 측정)

  • 김학민;노태옥;이범진;김선태
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.342-343
    • /
    • 2000
  • 다양한 배출원을 통해 외부로 발산되는 악취유발물질이 생활환경에 미치는 영향을 객관적으로 조사하고 평가하기 위해서는 인간의 감각기관을 이용하는 관능측정법과 화학성분을 분석하는 기기분석법을 동시에 적용하는 것이 필요하다. 그러나 인간의 감각기관을 이용하여야 하는 관능측정법의 경우 판정인이 장시간에 걸쳐 악취현상을 평가할 수 없다는 한계를 갖고 있으며, 기기분석법의 경우도 측정방법의 특성상 장시간 동안 시료를 채취하기 어려운 문제점을 갖고있어 풍향 및 풍속 등 기상조건에 따라 순간적으로 감지되는 취기수준이 다른 악취현상을 명확하게 규명하는데 일정부분의 한계를 갖게된다. (중략)

  • PDF

A Study on an experimental basis a use deodorize stink of food-waste in order to cooling dehumidification (냉각 제습에 의한 음식물 쓰레기 처리장치 악취제거에 관한 실험적 연구)

  • Park, I.S.;Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • This paper presents an effective cooling dehumidification method to remove odorous gas from food-wastes. The odorous gases, such as Styrene, Ammonia, Hydrogen sulfide and Acetaldehyde, are produced in environments where temperature is $50\sim80^{\circ}C$ and humidity is $40\sim70%$. Under such conditions, experiments are performed reiteratively using experiment equipments. The effect of the cooling dehumidification is measured via measuring instrument, and this research is focused on improving efficiency. The effect of cooling dehumidification using measuring instrument is validated. At $80^{\circ}C$, four type of gases that was mentioned previously showed generally better cooling efficiency with a good result for a component concentration. Among them, hydrogen sulfide gas demonstrated the highest reduction of 50%.

  • PDF

Analysis of the Compounds of Unpleasant Odor from the Cotton Fabrics through Different Washing Conditions (세탁조건에 따른 면직물 중의 악취성분 분석)

  • 박명자;최해운
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.5
    • /
    • pp.555-564
    • /
    • 2002
  • The purpose of this research was to analysis compounds of unpleasant odor from the cotton fabrics in dehydration and drying process during washing. The cotton fabrics were treated with various commercial detergents and fabric softener or cationic surfactants such as Cetyltrimethylammonium bromide(CTAB) and Benzalkonium chloride(BC), then dehydrated and dried. The compounds of odor impregnated in fabric were detected by using CC-MS. The results are as follows: The fabrics treated with a powder-type detergent, CTAB and BC gave out compounds unpleasant odor. n-Butyraldehyde and isobutyaldehyde produced during microorganism growth were revealed as source of the compounds of the unpleasant odor. However, no aldehydes were detected from the fabrics treated with commercial fabric softener which seems to act as a deodorizer.

  • PDF

Patterns of Offensive Odor Compounds According to Blocks in Shiwha Industrial Complex (시화산업단지의 블록 별 악취유발물질 특성)

  • Byeon, Sang-Hoon;Lee, Jung-Geun;Kim, Jung-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1161-1168
    • /
    • 2009
  • This research was conducted on characteristic of offensive odors in Shihwa industrial complex. Result of blocks distribution of TVOC indicates that mechanic block, site D, was the highest concentration (74 ppb). Chemistry block, site A, was the second highest concentration (50 ppb). Also, mixed blocks, metal blocks and park etc. were measured almost similar concentration about 30 ppb, but mixed block, site F, was the place where concentrations were the smallest. Average of TVOC was shown about 35 ppb concentration. Aldehydes including acetaldehyde, butyraldehyde and hydrogen sulfide concentrations were prevalent among offensive odors in Shihwa industrial complex. Comparing the offensive odor intensity mostly about acetaldehyde, butyraldehyde and hydrogen sulfide which contain high offensive odor intensity showed results that sites A, B (chemistry block) and site D, I (mechanic block) site H (metal block) have showed the intensity over 1. In the case of acetaldehyde, relatively the high odor intensities over '2' were able to obtain in many cases. The correlation coefficient (r) for hydrogen sulfide was 0.91, so that high positive correlation exists between offensive odor intensity and the hydrogen sulfide element. Butyraldehyde also showed high positive correlation coefficient, as 0.82. Correlation coefficient of acetaldehyde that had the highest value as offensive odor substance was 0.62, had somewhat correlation with offensive odor intensity.

Volatile Organic Compounds Production from Aerobic Biotreatment of Dairy Wastewater by a Sequencing Batch Reactor (연속회분식반응기(SBR)에 의한 낙농폐수의 호기성처리에서 휘발성유기물질 발생)

  • Hong, Ji-Hyung
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • Aerobic sequencing batch reactor (SBR) was used to treat screened dairy wastewaters. The study examined the production of volatile organic compounds (VOCs) and volatile fatty acids (VFAs) in the aerobic SBR and raw manure effluent storage over 35 days. The reduction of total VFAs in the aerobic SBR was over $59\%$ removal than that of the raw manure. Acetic acid production in the aerobic SBR and the raw manure effluent storage were kept 138 and 286 mg/L. The propionic acid in the aerobic SBR was 1.9 mg/L, while the raw manure effluent storage was 68 mg/L, respectively. The concentrations of VOCs in the aerobic SBR reactor and effluent fill down remarkably than the raw manure storage. The results confirmed that the aerobic biological treatment is an essential requirement for minimizing odor problems.

  • PDF

Study on Removal of Trace Components from Landfill Gas Hydrate (매립가스 하이드레이트에서 미량성분 제거에 관한 연구)

  • Shin, Hyungjoon;Moon, Donghyun;Han, Kyuwon;Lee, Jaejung;Yoon, Jiho;Lee, Gangwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.152.1-152.1
    • /
    • 2010
  • 매립지에서 유기물의 분해로 발생되는 매립가스는 악취 등으로 인한 대기오염뿐만 아니라 온난화지수가 21인 메탄이 약 50vol% 이상 포함되어 있어 지구온난화에 큰 영향을 미친다. 하지만 매립가스를 에너지원으로 활용하면 대기오염저감, 지구온난화 감소, 대체에너지원 확보뿐만 아니라 CDM사업 등과 연계하여 부가수익창출이 가능하다. 현재 국내에는 약 242개의 폐기물매립지가 있는데, 이중 매립가스를 활용하는 곳은 단지 14개소로 개별 경제성이 있는 대형매립지에서만 자원화시설을 설치하여 운영 중이며 그 외 매립지에서는 매립가스를 소각 또는 단순 대기 방출하여 대기오염유발과 동시에 대체에너지원 미활용으로 국가차원에서 큰 손실이므로 이를 활용할 수 있는 기술개발이 시급하다. 현재 매립가스 에너지화 기술로는 매립가스 열량에 따라 가스엔진, 가스터진, 증기터빈을 이용하는데 국내에서는 수분제거와 같은 간단한 처리 과정을 거친 후, 정제 없이 사용한다. 그런데 매립가스 구성 성분 중 일부 미량가스($H_2S$ 등)는 부식성이 높아 실제 공정에서 큰 문제점으로 작용하게 되므로 전처리공정이 반드시 필요하다. 본 연구에서는 중소규모 매립지에서 발생하는 매립가스를 중심적환장으로 이송하여 경제성을 가지는 에너지원으로 활용할 수 있는 기술개발을 목표로 하이드레이트 기술을 활용함에 있어 전처리 기초연구를 수행하였다. 매립가스 구성성분 중 대표적 악취물질인 메르캅탄과 부식성 물질인 황화수소의 전처리 기술로서 활성탄 흡착방법을 이용하여 외부에서 관찰이 가능하고 흡착탑을 2단으로 구성하여 활성탄 흡착탑을 제작하였다. 대상가스는 일반적으로 매립가스에 포함되어 있는 성분으로 제작하여 사용하였고 흡착탑 전 후 가스의 성분분석은 LMSxi를 이용하였다. 실험결과 활성탄의 상태, 접촉시간, 흡착탑의 구성에 따라 50~80%의 제거효율을 보였으며 이는 활성탄 흡착탑을 매립가스 에너지화의 전처리 시설로 사용될 경우 각각의 변수들에 대해 정확한 공정설계가 필요하다고 할 수 있다.

  • PDF

Isolation and Identification of Bacteria Removing Sulfur Compound Odor (황 화합물계 악취 제거 미생물의 분리 및 동정)

  • 김진수;유용규;이상섭
    • Korean Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.127-132
    • /
    • 2004
  • We isolated 50 strains from sludge of wastewater treatment aeration tank using selective medium for Thio-bacillus sp. by membrane filtration method. They were identified as Thiobacillus neapolitanus (7), T. tepidarius (4), T. dientrificans (5), T. versutus (23), T. intermedius (2) and T. perometabolis (9). We selected Thiobacillus versutus strain KT51, which had the highest removal efficiency (100%) of hydrogen sulfide and the highest removal efficiency (85%) of dimethyl sulfide for 30 min in screen test. Also Thiobacillus versutus strain KT81 had the highest removal efficiency (26%) of dimethyl disulfide for 30 min in screen test. In applification of lab-scale reactor (closed-biological treatment) using Thiobacillus versutus strain KT51, results were 99.8% (<0.02 ppm) removal efficiency of hydrogen sulfide for 15 min.