• Title/Summary/Keyword: 아크소호부

Search Result 24, Processing Time 0.039 seconds

New Arc Chamber to Improve Breaking Capacity (차단용량 향상을 위한 신소호 구조)

  • Park, Jin-Young;Cho, Hea-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.321-326
    • /
    • 2012
  • The mechanism unit, arc chamber and trip unit are imperative components of MCCB which will decide the level of performance of MCCB. Among them, Arc chamber unit is used for extinguishing arc rapidly of fault current and induce the arc inside of grid. At that time inducing arc will split into parts and cooled rapidly so the arc would disappear. This paper suggests new arc chamber unit to improve arc extinguishing performance with optimum design and are applied to actual products based on the results.

Modeling and Properties of Are Insulation for ATCB (ATCB의 아크 소호 절연구조 설계 및 특성 연구)

  • Han, Se-Won;Moon, Hee-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.456-457
    • /
    • 2007
  • ATCB의 구조 중 아크 소호부는 공기 중에 노출된 금속(그리드)이 일정한 간격을 두고 적층되어 있는 모양을 하고 있다. 아크 소호부의 주기능은 아크를 소호실 안쪽으로 유도하여(기중 차단방식) 여러 개의 짧은 아크로 분할시키며 아크를 냉각, 소멸시켜 전류 차단을 빠르게 하는 것이다. 아크를 구동시키는 소호살의 형상과 구조에 따라 아크의 구동력은 많은 차이를 보이게 된다. 여기서는 신개념의 자동절체 스위치인 ATCB(Automatic Transfer Circuit Breaker)의 그리드의 구조에 따라 아크 구동력을 비교하여 아크 소호부의 최적 형상과 절연구조를 설계, 모델링하였다.

  • PDF

A Study of Change of Air-arc Behavior due to Pressure Waves in Low Voltage Circuit Breakers (저압차단기 기중아크의 압력파에 의한 거동 변화 연구)

  • Song, T.H.;Kwon, J.L.;Kwak, C.H.;Kwon, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1330-1331
    • /
    • 2008
  • MCCB와 같은 저압차단기는 접점사이에서 발생한 아크를 금속의 소호그리드로 유입하여 아크를 소호하게 된다. 일반적으로 고장 전류 차단시에 저압차단기에서 발생한 아크는 고압.고열이므로 아크에너지에 의해 소호부의 압력이 크게 상승하게 되며 압력에 의해 아크의 거동은 큰 영향을 받게 되므로 아크 구동력의 증가를 위해서는 압력에 의해 아크거동이 어떠한 영향을 받는지에 대한 정보가 필요하다. 본 연구에서는 압력파의 영향을 명확하게 하고 다른 요소에 의한 영향을 배제하여 압력파와 아크거동간의 상호작용만을 실험하기 위해 시험용 소호부를 고안하여 시험용 소호부에서 아크의 압력과 거동을 측정.분석하여 아크거동과 압력파의 관계를 연구하였다.

  • PDF

Arcing Time 측정을 통한 나선형 VI접점의 접점배치에 따른 Arc Control 성능비교

  • Kim, Byeong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.247-247
    • /
    • 2011
  • 차단기의 주 임무는 사고전류를 차단하는 것이다. 진공 인터럽터는 진공차단기의 차단부로서 진공차단기의 핵심부이다. 사고전류 발생시 전극이 분리되면서 아크가 발생한다. VI의 아크소호 방식에는 크게 축자계 방식과 횡자계 방식이 있는데 본 논문은 횡자계 방식에 관한 것이다. 교류전류에서는 전류가 일시적으로 공급되지 않는 전류영전에서 아크소호가 가능하다. 전류영점에서 아크가 소호된 직후 극간저항은 거의 0에서부터 무한대까지 급격하게 변화하는데 이때 이 저항의 증가에 비례하여 과도회복전압이 발생한다. 하지만 잔류플라즈마의 소멸에는 일정시간이 소요되며 아크가 소호된 이후에도 종종 극간에 금속증기가 존재하게 된다. 잔류플라즈마는 전기전도도를 가지므로 극간에 과도회복전압이 걸리면 전류영점 직후에 아크를 통해 흘러 결국 아크의 재점호를 야기시키는 post arc current를 발생시킬 수 있다. 따라서 전류영점의 충분한 시간 이전에 아크를 확산아크로 전환시켜 극간에 존재하는 잔류 플라즈마 량을 최소화시켜야 한다. VI 내부의 아크거동에 미치는 인자에는 접점재료와 VI 용기내부의 진공도 이외에도 전극의 직경, 쉴드, 전극의 개극속도, 최종 극간거리 등이 있다. 본 연구에서는 나선형 VI 접점을 대상으로 두 접점 사이의 비틀림 각도에 따른 아크제어성능을 비교분석하였다.

  • PDF

The comparison of various arc characteristics and studying failure cases in 170kV GIS (170kV GIS ARC 소호방식 특성 비교 및 고장사례 연구)

  • Jeon, Sang-Dong;Kim, Do-Won;Lee, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.495-496
    • /
    • 2011
  • 기존에 사용되고 있는 초고압 가스차단기(GCB : gas circuit breaker)는 대부분 퍼퍼형(puffer type) 소호방식의 가스 차단기를 사용하였다. 퍼퍼형 소호방식은 차단동작에 있어서 대단히 큰 조작력이 요구되고 소호부 size가 큰 단점을 가지고 있다. 이러한 문제를 해결하기 위해 아크 자체의 에너지를 아크 소호에 필요한 압력상승을 일으키는 데 이용하는 자력소호방식(self-extingishing type)에 작은 체적의 퍼퍼 실린더를 병용하는 복합소호방식(hybrid extingishing type) 차단부가 개발되어 사용이 확대되고 있다. 본 논문에서는 차단기의 소호방식별 특성을 비교 분석하고 최근 사용이 확대되고 있는 복합소호방식 차단기의 고장사례 분석을 통해 개선대책을 제시하였다.

  • PDF

Modeling for arc characteristics of DC circuit breaker (직류차단기의 아크특성 모델링)

  • Kim, Yong-Jung;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.54-55
    • /
    • 2017
  • 배전계통에서 병렬아크는 전선이나 노후된 설비의 절연파괴에 따른 합선에 의하여 발생하고 직렬아크는 차단기, 소켓-플러그, 커플러 등 접속기에서 부하와 전원이 분리되는 경우에 발생한다. 이러한 아크현상에 대응하기 위해서는 아크의 특성을 해석하고 그에 따른 아크소호방법이 제시되어야 한다. 병렬아크는 1889년 발견된 Paschen의 법칙에 따르며, 평행한 금속판 사이에 아크방전이 시작되는 항복전압이 매질가스의 종류 및 압력과 개리거리에 따른 함수로 규정된다. 반면, 직렬아크는 아직까지 명확한 해석방법이 제시되어있지 못하다. 본 논문에서는 직류 차단기에서 발생하는 직렬 차단 아크의 촉발과 지속적인 발생, 소호에 대한 특성을 분석하여 3가지 특성을 기반으로 하는 직렬 차단아크전류 모델을 제안하고 실험을 통하여 검증하였다.

  • PDF

A Study on the Characteristics of Arc Quenching of DC Interruption in the Magnetic Field (자계내에서 직류 차단시 아크소호 특성에 관한 연구)

  • 이동원;송현직;박원주;이광식;이동인
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.5
    • /
    • pp.66-74
    • /
    • 1996
  • In this paper, the arc currents, voltages and these waveforms were investigated when negative DC high voltages applied to neddle-pane electrodes to study arc quenching phenomena of DC interruption in the. magnetic field. The conclusion of this study are as follows : There are no dynamic arc characteristics in the no magnetic field. Not only dynamic arc characteric but also zero points of arc current which are generated from repeating frequence of arc discharge under the magnetic fields were observed. The more magnetic field were applied, the repeating frequence of arc discharge were more increased..

  • PDF

A Study on the Hybrid Arc Extinguishing Mechanism of the DC Circuit Breaker (DC 차단기의 하이브리드 아크 소호 기법에 관한 연구)

  • Joo, Nam-Kyu;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.250-256
    • /
    • 2015
  • Digital load is increasing suddenly for various reasons, such as easy control and management. Accordingly, a consumption pattern of load is becoming DC. However, the power supply is supplied by AC power. The load power supply substantially needs DC power. AC power has to be converted to DC power. Renewable energy sources like solar, wind and fuel cells are DC power generation, but the transfer needs to through by AC power, thus DC power has to be converted to AC power. Resultantly, a multi-stage conversion loss is constantly increasing. The power distribution system of DC-based is required for effective use of these energy sources. This requires a DC load, as well as is necessary to develop DC breaker. This study is expect for system and equipment for reliable DC power distribution through the study of the arc extinguish technology for direct current a hybrid arc extinguishing technology with permanent magnets technology.

Development of 460[V]/225[A]/50[kA] Contact System in Current Limiting MCCB using an estimation and analysis method for the interrupting capability (차단성능 평가해석기법을 적용한 강자계 구동방식의 460[V]/225[A]/50[kA]급 한류형 MCCB 소호부 개발)

  • 최영길;박찬교
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.78-84
    • /
    • 2004
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widely used in power distribution systems. In the paper, it has been investigated how much interrupting capability is improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), especially contacts and arc runner. Prior to the interrupting testing, it is necessary for the optimum design tc analyze electromagnetic forces on the contact system generated by current and flux density. This paper presents both our computational analysis and test results on contact system in MCCB

Development of Contact System in 460[V]/225[A]/50[kA] Molded Case Circuit Breaker (460[V]/225[A]/50[kA] 한류형 배선용 차단기 소호부 개발)

  • 최영길;구태근;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.137-144
    • /
    • 2002
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widely used in power distribution systems. In the paper, it has been investigated how much interrupting capability is improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), especially arc runner. Prior to the interrupting testing, it is necessary for the optimum design to analyze electromagnetic forces on the contact system generated by current and flux density. This paper presents both our computational analysis and test results on contact system in MCCB.