• Title/Summary/Keyword: 아크릴 레진

Search Result 94, Processing Time 0.029 seconds

The effect of Silano-pen on the shear bond strength of resin to feldspathic porcelain and zirconia (실라노 펜의 적용이 장석계 도재 및 지르코니아와 레진의 전단결합강도에 미치는 영향)

  • Shin, Myoung-Sik;Lee, Jeong-Yol;Kim, Min-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the effect of applying Silano-pen to feldspathic porcelain and zirconia on shear bond strength with composite resin. Materials and methods: Feldspathic porcelain and zirconia specimens were produced into 30 per each 2 mm thick and 12 mm in diameter and their surface was made smooth and even and then embedded in acrylic resin. The specimens were divided into each Group F (Feldspathic porcelain) and Group Z (Zirconia), (1) Hydrofluoric acid etching and silane (F1 & Z1), (2) Silano-pen and silane (F2 & Z2), (3) Hydrofluoric acid etching and Silano-pen, silane (F3 & Z3). After surface conditioning, substrate surfaces of the specimen were examined by SEM. Composite resin cylinders (2 mm high, 3 mm in diameter)were bonded to specimen and shear bond strength between ceramic and composite resin was measured by using universal testing machine. The measured values were statistically analyzed by using two way ANOVA and Tukey's multiple comparison test (${\alpha}=.05$). Results: In the scanning electron micrograph of the treated ceramic surface, Group F2 and F3 appeared the high roughness and Group Z3 appeared the highest density of silica particle. In Feldspathic porcelain, the result of measuring shear bond strength showed that Group F3 was measured to be highest and Group F1 was measured to be lowest but there was no statistical significance among Groups. In zirconia, Group Z3 was measured to be highest and Group Z1 was measured to be lowest and there was statistical significance among Groups (P<.05). Conclusion: In zirconia, applying hydrofluoric acid etching and then Silano-pen and silane is effective for composite resin adhesion.

Improvement of Articulation Disorder Using Flexible Partial Denture in Intellectural Disability Patient with Missing Lower Incisors (하악 전치부 상실로 인한 조음장애를 보이는 경도 지적장애 환아에서 탄성의치를 통한 조음능력의 향상)

  • Choi, Haein;Choi, Byungjai;Choi, Hyungjun;Song, Jeseon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.306-313
    • /
    • 2013
  • Speech is complex psycho-physiological mutual process which includes many orofacial organs. Especially, teeth play an especially important role as an articulation organ in conjunction with the lips and tongue. When teeth are missing, the position of tongue and mandible is adjusted to produce correct sound. If a patient's adaptive function is inadequate for modification of malocclusion, prosthodontic and orthodontic interventions are necessary. Missing teeth of young patients should be reconstructed bacause it can cause malocclusion, decreased masticatory efficiency, articulation disorders, esthetic problem, and temporomandibular disorder. Valplast$^{(R)}$(Valplast International Corp, New York, USA) flexible denture is useful for rehabilitation due to its excellent physical properties, esthetics, and small volume. This case is regardingan intellecturally disabled patient with anarticulation disorder caused by missing lower incisors due to trauma. The patient showed improvement in articulation by using flexible partial denture. The purpose of this report is to figure out the influence of missing lower anterior teeth on articulation.

Effect of various casting alloys and abutment composition on the marginal accuracy of bar-type retainer (합금의 종류와 지대주 성분이 바형 유지 장치의 변연 적합도에 미치는 영향)

  • Lee, Yun-Hui;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.85-91
    • /
    • 2012
  • Purpose: The object of this study was to determine if the low-priced alloy and metal UCLA abutment could be available for manufacturing bar-retained framework of implant prosthesis. Materials and methods: Bar structure was classified into 4 groups, The specimen of group 1 and 2 were based on casting high noble metal alloys and noble metal alloys with gold UCLA abutment. The specimen of group 3 and 4 were based on casting noble metal alloys and base metal alloys with metal UCLA abutment. Cast bar structure was installed in an acrylic resin model and only the screw on the hexed abutment side was tightened to 20 Ncm. On the opposite side, vertical discrepancy was measured with stereo microscope from front, back, and lateral side of the implant-abutment interface. One-way ANOVA was performed to analyze the marginal fit discrepancy. Results: One-way ANOVA test showed significant differences among all groups ($P$<.05) except for Group 1 and 3. Among them, difference between Group 1 and 2 was noticeable. Measured vertical discrepancies were all below $70{\mu}m$ except to Group 2. Conclusion: Base metal alloy and metal UCLA abutment could be used as an alternative to high-priced gold alloy for implant bar-retained framework.

Comparison of the Microleakage and Shear Bond Strength to Dentine of Different Tricalcium Silicate-based Pulp Capping Materials (Tricalcum-silicate 기반 치수복조제의 미세누출 및 상아질 전단결합강도 비교)

  • Kim, Miri;Jo, Wansun;Jih, Myeongkwan;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.76-84
    • /
    • 2019
  • This study evaluated the microleakage of three restorative materials and three tricalcium silicate-based pulp capping agents. The restorative materials were composite resin (CR), resin-reinforced glass ionomer cement (RMGI), and traditional glass ionomer cement (GIC) and the pulp capping agents were TheraCal $LC^{(R)}$ (TLC), $Biodentine^{(R)}$ (BD), and $ProRoot^{(R)}$ white MTA (WMTA). Additionally, shear bond strengths between the pulp-capping agents and dentine were compared. Class V cavities were made in bovine incisors and classified into nine groups according to the type of pulp-capping agent and final restoration. After immersion in 0.5% fuchsin solution, each specimen was observed with a stereoscopic microscope to score microleakage level. The crowns of the bovine incisors were implanted into acrylic resin, cut horizontally, and divided into three groups. TLC, BD and WMTA blocks were applied on dentine, and the shear bond strengths were measured using a universal testing machine. The microleakage was lowest in TLC + GIC, TLC + RMGI, TLC + CR, and BD + GIC groups and highest in WMTA + RMGI and WMTA + CR groups. The shear bond strength of BD group was the highest and that of WMTA group was significantly lower than the others.

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

AN EXPERIMENTAL STUDY ON REINFORCEMENT OF ACRYLIC RESIN DENTURE BASE (아크릴릭 레진 의치상 강화에 관한 실험적 연구)

  • Kim Hyung-Sik;Kim Chang-Whe;Kim Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.411-430
    • /
    • 1994
  • The denture may be fractured accidentally by an impact while outside the mouth, or may be cracked or broken while in service in the mouth. The latter is generally a fatigue failure caused by repeated flexure over a period of time. This investigation compared the flexural fatigue resistance, the impact force and the transverse strength of two denture base materials with and without the grid strengthener, the T300, the T800 and the Kevlar fiber to evaluate the fracture resistance. The distribution and behavior of fibers across fracture lines were examined by Hi-Scope Compact Microvision System. Through analyses of the data from this study, the following conclusions were obtained. 1. The flexural fatigue resistance, impact strength and transverse strength of high impact strength resin were higher than those of conventional heat polymerizing resin, but statistically there was no significant difference(p>0.05). 2. All specimens with and without the grid strengthener did not show significant differences in the flexural fatigue, the impact and the transverse strength test(p>0.05). 3. All specimens reinforced with the T300, the T800 and the Kevlar fiber showed significant increase of the fatigue resistance and the impact force(p<0.05). 4. All specimens reinforced with the T800 and the Kevlar fiber showed significant increase of the transverse strength(p<0.05). 5. All specimens reinforced with the T300, the T800 and the Kevlar fiber exhibited greenstick fractures. The fibers tended to remain enveloped in the resin, resisting pull-out.

  • PDF

REINFORCEMENT OF ACRYLIC RESIN WITH METAL WIRE (금속 wire의 아크릴릭 레진 보강효과에 관한 연구)

  • Jeong, Chang-Mo;Jeon, Young-Chan;Lim, Chang-Sup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.823-832
    • /
    • 1996
  • The purpose of this study was to assess the effect of 1) the diameter(0.7,1.0,1.2mm) and number(1,2,3) of commonly available orthodontic metal wires embedded in self-curing orthodontic acrylic resin specimens($64{\times}10{\times}3mm$) and 2) the use of chemical adhesive system(Silicoater, Metalprimer) to prevent slipping at the interface between the resin and the metal wire on reinforcement by using three-point bending test. From this study, the following results were obtained. 1. No statistically significant difference was found among the transverse strengths for the control without reinforcement, one 0.7mm wire, two 0.7mm wires, three 0.7mm wires, and one 1.0mm wire groups(P>.05). 2. In the groups with 1.0 or 1.2mm wires, the transverse strength increased in proportion to the increase of number of wires(P<.05). 3. In the groups with 0.7 or 1.0mm wires, neither of Silicoater and Netalprimer increased the transverse strength significantly(P>.05). 4. No statistically significant difference was found in transverse strength between Silicoater groups and Metalprimer groups with same diameter of wires(P.>05). From these result, it is concluded that diameter of wires is a primary considering factor to reinforce the acrylic resin effectively and, when this requirement is satisfied, increased number of wires or chemical adhesive systems can be expected to produce the additional reinforcing effect.

  • PDF

A STUDY ON THE EFFECT OF PERMA CURE SYSTEM ON THE PHYSICAL PROPERTIES OF ACRYLIC RESIN SURFACES (광중합(光重合) 활택 경화제가 아크릴 레진 표면에 미치는 물리적 성질에 관한 연구)

  • Bae, Jeong-Sik;Lee, Ho-Yong;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.155-164
    • /
    • 1985
  • Acrylic resin has some disadvantages in its physical properties such as a low surface hardness, being easily abraded as well as low degree of impact resistance. To overcome these disavantages, Perma Cure System was introduced in 1981, in which photo polymerizing monomers coated on acrylic resin surface were polymerized. In this study, to observe the effect of Perma Cure System on physical properties of treated surface of different types of acrylic resin, abrasion resistance, surface hardness and surface roughness of 4 different types of resin (Premium, Ortho-jet acrylic, Quick resin, Thermo jel) were tested before and after coating treatment. The conclusions arised from this study are as follows; 1. In all types of resin, the abrasion resistance of coated specimen was higher than that of uncoated specimen, and there was difference in amount of abrasion among the types of coated resin. 2. In all types of resin, the surface hardness of coated specimen was higher than that of uncoated specimen, and there was no difference in surface hardness among the types of coated resin. 3. In all types of resin, surface roughness of coated specimen was lower than that of uncoated specimen, and was different according to the degree of surface roughness before coating treatment in same sort of resin specimen.

  • PDF

EVIDENCE OF SUSTAINED RELEASE OF CHLORHEXIDINE ADDED TO ACRYLIC RESIN : PRELIMINARY INVESTIGATION OF A POTENTIAL DRUG DELIVERY SYSTEM (아크릴릭 레진에 혼합된 클로르헥시딘의 방출 : 새로운 방법의 약물송달시스템을 위한 예비실험)

  • Choi, Yeong-Chul;Lee, Eun-Yeong;Lee, Jin-Yong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.259-267
    • /
    • 1998
  • For more than two decades, many investigators have tried a variety of methods for delivering antimicrobial agents to the oral cavity with the objective of eliminating mutans streptococci. In the belief that the effectiveness of chemotherapy might be improved by a more effective delivery system, the intention of the present study was to exploit a new drug delivery system delivering chlorhexidine to the oral cavity. The vehicle delivering chlorhexidine tested in this study was self-curing acrylic resin(polymethyl methacrylate). The powder of the acrylic resin was polymerized with the 5 different liquid preparations, in which $Chlorzoin^{(R)}$ was mixed with five different monomer/Chlorzoin ratios immediately prior to the polymerization, in a stainless steel mold ($40mm{\times}40mm{\times}2mm$). A total of 50 cured resin specimens were divided into 5 groups according to the different monomer preparations. Every specimen was soaked in an airtight container filled with distilled water (100 ml) and then kept in an incubator at $37^{\circ}C$. The solutions (0.8 ml) were collected from the container at every 24 hours, and the amount of released chlorhexidine in the solutions was measured in an ultraviolet spectrophotometer at 250nm. The container was refilled with distilled water every after measurement. This procedure was repeated for 14 days. It was found that chlorhexidine was continuously released from all of the 50 specimens during the experimental period. And it was noted that the pattern of chlorhexidine release was a type of sustained-release preparation, that is, the amount of the released chlorhexidine at the first day in all 5 groups was high (p<0.0001), and then the release was decreased during the rest of the experimental period (p<0.001).

  • PDF

Esthetic improvement in patient with deep bite using porcelain laminate veneers and a full veneer crown (과개교합 환자에서 도재 라미네이트 비니어와 전부도재관을 이용한 심미수복 증례)

  • Yoon, Jong-Sang;Shin, Soo-Yeon;Lee, Jonghyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.192-198
    • /
    • 2014
  • This case is a porcelain laminate veneer (PLV) and all-ceramic crown treatment case on a female patient in her thirties who visited for esthetic improvement. The patient's chief complaint was protrusive and uneven anterior teeth, and she wanted minimum tooth reduction. The patient was in skeletal class II deep bite. Considering this, check bite method was used for mounting on articulator during diagnostic wax-up. Tooth reduction was done using mock-up base on diagnostic wax-up, and the amount of deletion was checked by index. For the accordance of shade, PLVs were restored in prior to all ceramic crown. After using all-ceramic crown, satisfactory esthetic improvement was obtained.