• Title/Summary/Keyword: 아치콘크리트

Search Result 81, Processing Time 0.021 seconds

Flexural Behavior of RC Arch Deck Subjected to Static Loading (철근콘크리트 아치 데크의 정적 휨 거동)

  • Eom, Gi-Ha;Yang, Dal-Hun;Kim, Sung-Jae;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.4
    • /
    • pp.371-378
    • /
    • 2017
  • In this study, the flexural behavior of the RC Arch Deck under static loading was evaluated. Flexural test was carried out using an actual size RC Arch Deck with a length of 2.5 m, a center thickness of 100 mm and an end thickness of 160 mm. The test results showed that it's ultimate load was 1.74 times higher than the ultimate design load. On the other hand, it showed that the flexural behavior has different behaviors (i.e. different stiffness). This type of structural behavior indicates that it has inter-dependency between the deck and the supporting girder. Therefore, it is necessary to confirm the precise behavior by the static loading test of the RC Arch Deck, excluding the girder effect in the future study. The overall results showed that RC Arch Deck has excellent structural performance due to the structural advantages of the arch shape. In the future, the RC Arch Deck can be applied as a long span slab.

Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch (프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가)

  • Ahn, Jin-Hee;Yim, Hong Jae;Bang, Jin Soo;Jeon, Seok Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Precast concrete segment arch system has an economic and construct ability that combined with advantage of precast concrete and arch behavior. A precast concrete segment arch system with outrigger is consisted of segmented precast panels, a steel outrigger rib, and V-strip to connect precast panels with a steel outrigger rib and cast-in-place anchors in precast panels to connect V-strip should have sufficient pull-out capacity to form its arch shape by site lifting for assembled precast panels and outriggers. However, it is difficult to secure its embedment depth due to the relatively shallow thickness of precast panel. It can be also occurred that flexure deformation of precast panels caused by its pull-out behaviors. In this study, pull-out capacity of cast-in-place anchor was examined for construction of precast concrete segment arch system with outriggers. Therefore, a total of 24 precast panel specimens were fabricated to examine pull-out capacities of cast-in-place anchor in precast panels, and installation depth of anchors, diameter of anchors and wire mesh effects for the precast panel were examined. From this pull-out tests, its pull-out capacities and failure modes were evaluated and the type of the cast-in-place anchor applicable to the precast concrete segment panel arch system with outriggers was determined from comparison of the design specification values.

Strength Evaluation on Sectional Members of Prefabricated Precast Concrete Arch with Reinforced Joint (보강된 이음부가 적용된 조립식 프리캐스트 콘크리트 아치의 단면 강도 평가)

  • Joo, Sanghoon;Chung, Chulhun;Bae, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1363-1372
    • /
    • 2014
  • In the previous study, the structural performance of proposed precast concrete arch with reinforced joint was evaluated by structural experiment. In this paper, finite element analysis considering both material and contact nonlinearity was carried out on the specimens of the previous study. Based on the result of analysis and experiment, friction coefficient between concrete blocks was determined. To evaluate the strength of sectional member, elastic analysis was carried out on the arch using linear elastic analysis program. The section force was compared with the nominal strength of arch section. It was concluded that the maximum load of all the specimens exceed the nominal strength of arch section. Those results of the strength evaluation were similar to the results of structural experiments. Therefore, it is concluded that the elastic analysis and ultimate strength model can effectively evaluate the strength for the proposed precast concrete arch composed of concrete blocks and reinforced joint in design.

Numerical Analysis for Carinthian Cut and Cover Tunnelling Method (카린시안 터널 공법의 기준 제안을 위한 수치 해석적 연구 - 국내 고속철도 복선터널 표준 단면을 기준으로 -)

  • Roh, Byoung-Kuk;Baek, Seung-Kyu;Cha, Min-Woong
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • Carinthian cut and cover tunnelling method which combines cut & cover and NATM tunnel excavation method has increased the interest. Design and construction of arch concrete have been increased, but there is no applicable standards for arch concrete. Therefore, in this study numerical analysis was performed to propose standards for the Carinthian tunnelling method considering a variety of conditions such as ground conditions, tunnel overburden thickness, thickness of backfill, and overburden surface slope angle changes, linear regression equations derived to classify and organize a rational, economical, and safe Carinthian cut and cover tunneling method based proposed.

Shear Compatibility Condition with Arch Action in Simply Supported RC Beam (단순지지된 RC보에서의 아치효과를 고려한 전단변형적합조건)

  • Lee, Seong-Chul;Cho, Jae-Yeol;Kim, Woo;Park, Byung-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.847-850
    • /
    • 2008
  • In simply supported concrete beams with concentrated load, there is arch action that the internal lever arm length varies through shear span. Recently shear analysis model considering this effect has been developed, but the analysis algorithm is so complicated. Moreover, the variation of internal lever arm length is not considered on the shear compatibility condition. In this study, the shear analysis model is developed more simply and the variation of internal lever arm length is considered on the shear compatibility condition. From these modifications, an actual shear behavior of RC beams subjected to concentrated load could be expected from the results of the proposed analysis model.

  • PDF

Out-of-Plane Shear Strength Models of SC Wall (SC 벽체의 면외 전단강도 특성)

  • Hon, Sung-Gul;Lee, Kyuong-Jin;Park, Dong-Soo;Kim, Won-Ki;Lee, Dong-Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.225-228
    • /
    • 2008
  • This paper presents out-of-plane shear strength models for composite wall with steel plates based on limit theorem in the framework of the plasticity theory. The formulas proposed by JEAG 4618 need to be reconsidered with a couple of limitations; ignoring the effect of bond stress generated by studs in the process of calculating arch action, illogically discriminating between concrete shear cracking strength and arch strength by algebraic relation in short shear span ratio(0-2.0). In most cases, reinforcement ratio is not sufficient to yield, as a result, arch strength is determined by accounting equilibrium including both bond strength and concrete compressive strength. We conducted experimental research assuming that SC wall is a continuous beam under the simplified loading patterns, changing main valuables involving the number of studs, stirrups. The results show good agreements with the formula and we quoted the test results of JEAG.

  • PDF

Structural Performance of Precast Concrete Arch with Reinforced Joint (보강된 이음부를 가진 조립식 프리캐스트 콘크리트 아치의 구조성능)

  • Chung, Chulhun;Joo, Sanghoon;Choi, Dongchan;Lee, Jongyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.29-47
    • /
    • 2014
  • The masonry stone arch bridge, due to its superior durability and aesthetics, has been one of the oldest and popular types of short span bridges. In Europe, this type of bridges have been continuously constructed, and numerous related researches have been conducted until recently. However, there are few construction cases in Korea since the economic efficiency and the construction effectiveness is not contentable. Therefore, this study proposed the reinforced joint to improve structural performance of the conventional arch systems which is proposed by previous researchers. The structural performance of the proposed reinforced joint, which consists of the transverse loop joint and the longitudinal reinforcement, is validated by experimental test of an arch bridge which is constructed using precast concrete segments. Based on this results of the experimental test, it is concluded that the strength of arch bridges can be enhanced by applying the proposed reinforced joints since the reinforced joint restrains hinge behavior and relative displacement between segments with a little reinforcement.