• Title/Summary/Keyword: 써니

Search Result 452, Processing Time 0.03 seconds

Experimental Study on Heat Transfer Characteristics of Thermosyphon Using Nanofluids (나노유체를 이용한 써모사이폰의 열전달 성능 특성에 관한 실험적 연구)

  • Lee, Moo-Yeon;Cho, Chung-Won;Lee, Ho-Seong;Won, Jong-Phil;Lim, Taek-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1073-1079
    • /
    • 2012
  • This study aims to experimentally investigate the heat transfer characteristics of a thermosyphon using nanofluids. A thermosyphon with three individual pipes, which share the internal volume of the evaporator section, was designed, and its performance was tested for various charge amounts, input powers of the evaporator section's heater, and concentrations of working fluids. The optimized charge amount of the thermosyphon using distilled water was 30%, and the thermal resistance of the thermosyphon with $TiO_2$ nanofluid was 18.1% lower than that with Ag nanofluid. In addition, the heat transfer performance of the thermosyphon with $TiO_2-1%$ was optimized at an input power of 300 W at the evaporator section's heater and a charge amount of 30%.

Analysis on Creative Time and Space Production in Korean Cinema - Focusing on the Film - (한국영화에 나타난 창의적 시공간 연출 분석 -영화 <써니>를 중심으로)

  • Kim, Seong-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.168-177
    • /
    • 2019
  • In cinema, a montage can be defined as temporalization. In reverse, it is evident that this method results in the spatialization of time. In movies, you are free to go to the past or future, see separated times together, and separate the same time into different ones. Therefore, in one aspect, time is turned into space, and on the other hand, space is turned into time. In conclusion, space in cinema inevitably expresses time. The movie the creative arrangement of time and space played a big role in making a movie that simply overlaps a story from high school to the present attract over seven million audiences. Director Kang Hyung-cheol used his unique film production language to transform boring into cheerfulness and stale to delight, and he helped the audience heal their wounds from their youth. He said, "The most important aspect of movie production is creating visual stories, and the background of such visual story is time and space." This paper aims at analyzing the creative time and space production of the director in the film .

저궤도 위성의 열진공 시험 및 발사 동안의 써미스터 데이터 처리

  • Lee, Na-Yeong;Gwon, Dong-Yeong;Jeon, Mun-Jin;Kim, Dae-Yeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.187.1-187.1
    • /
    • 2012
  • 본 논문은 저궤도 위성의 각 유닛의 온도 정보를 획득하기 위해 사용되는 온도 센서인 써미스터의 data 처리를 위한 calibration 방법을 정리한 것이다. 써미스터는 온도에 따라 저항 값이 바뀌는 소자이며, 위성 프로세서는 정전류 소스를 공급하고 여기에 걸리는 전압을 AD converter를 이용해 데이터로 전송한다. 지상에서는 전송된 데이터를 calibration 공식에 대입하여 온도 정보를 얻어낸다. 특히 발사 준비 및 발사 후 발사체와 분리되기 전까지 계속 모니터링이 필요한 배터리 온도 정보의 경우 배터리 내부의 한 개 써미스터에 대해 발사장전기시험장비와 발사체의 MUX 시스템 그리고 위성 내부 프로세서에서 프로세싱이 동시에 이루어지기 때문에 각 시스템의 영향성까지 고려해야 한다. 본 논문에서는 저궤도 위성의 열진공 시험 및 발사 동안의 실제 데이터 처리 결과를 통해 정밀한 써미스터 데이터 처리 및 그 시스템 설계에서 고려해야 할 점들을 정리한다.

  • PDF

Development of Thermosyphon for Cooling of High Power Electronic Component in Telecommunication System (통신시스템의 고발열 부품 냉각용 써모사이폰 개발)

  • 한재섭
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.2
    • /
    • pp.27-36
    • /
    • 1998
  • 통신시스템의 고발열 전자부품 냉각을 위해 3종류의 써모싸이폰을 각각의 용도에 따라 개 발하였으며 그 각각의 설계변수에 대한 냉각특성을 실험적으로 구하였다. TS-I에서는 증발부 내부 에 금속스크린 메쉬형심지를 삽입함으로써 시간에 따른 온도 변화를 작게 하여 냉각성능 안정성을 확보하였고, TS-II에서는 9W/cm2의 높은 냉각성능을 가진 루프형 써모사이폰을 개발하였으며 TS-III에서는 작동유체의 종류, 파이프개수 와이어 삽입여부등 써모사이폰의 주요 설계변수에 따 른 냉각특성을 구하였다.

A Study of Manhole Bursting due to Surcharged Flow in Large Sewer System (대규모 간선에 있어서 써차지 흐름에 동반되는 맨홀뚜껑 비산현상에 관한 연구)

  • Choi, Sung-Mo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.2 s.13
    • /
    • pp.53-59
    • /
    • 2004
  • The mechanism of manhole bursting which occurs at excess rainfall events Is studied by using both the physical model and the numerical model (SWMM ; Storm Water Management Model). The result of numerical simulation to steep pressure rising agrees well with that of the physical model at the sewer system under surcharged flow. A cause of manhole bursting is an expansion and spout of the condensed all at manhole that results from the surcharged flow and press wave propagation caused by gate operation or closure of conduit at pumping station.

Evaluations of Mn-Ni-Co type thermistor thin film for thermal infrared sensing element (열형 적외선 센싱소자용 Mn-Ni-Co계 써미스터 박막 특성 평가)

  • 전민석;최덕균
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.6
    • /
    • pp.297-303
    • /
    • 2003
  • Mn-Ni-Co type thin films were prepared at various conditions by a rf magnetron sputtering system. At the condition. or substrate temperature of $300^{\circ}C$ and $Ar/O_2$= 10/0, a cubic spinel phase was obtained. When oxygen was included in process gas, a cubic spinel phase was not formed even after the thermal annealing at $900^{\circ}C$. The thermistor thin film had no other elements except Mn, Ni and Co. The infrared reflection spectra of the thermistor thin films showed that the films had somewhat high reflectance for incoming infrared ray with some angle. The etch rate of the thermistor thin films was about 63nm/min at a condition of DI water : $HNO_3$: HCl = 60 : 30 : 10 vol%. The B constant and temperature coefficient of resistance of the thermistor thin films were 3500 K and -3.95 %/K, respectively. The voltage responsivity of the thermistor thin film infrared sensor was 108.5 V/W and its noise equivalent power and specific detectivity were $5.1\times 10^{-7}$ W/$Hz^{-1/2}$ and $0.2\times 10^6$cm $Hz^{1/2}$/W, respectively.

Thermal Response Analysis of Satellite Propulsion Tank with Thermostat Location Variation (써모스탯 위치변화에 대한 인공위성 추진제 탱크의 열적 반응 해석)

  • Lee, Kyun-Ho;Han, Cho-Young;Choi, Joon-Min;Moon, Hong-Youl
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.126-132
    • /
    • 2004
  • Thermal control of satellite propellant tank is achieved by patch heaters enabled by thermostat's behavior. It is important to attach the thermostat on the appropriate position of the propellant tank. However its position cannot be given with exact numerics because tank is spherical. In practice, the thermostat position is designated approximately in a relevant drawing approximately, thereby an engineer practices depending on his own experience and intuition. The sensitivity analysis for the position of thermostat is performed such that the influence on the thermal behavior and control of tank is examined quantatively. When assembling tank module, the reasonable performance on the thermal control is believed with possible human errors if the uncertainty in the position of thermostat is not quite large.

수변전설비의 최적관리와 트러블 대책⑦

  • 한국전력기술인협회
    • Electric Engineers Magazine
    • /
    • v.242 no.10
    • /
    • pp.11-14
    • /
    • 2002
  • 철탑, 건물 또는 피뢰침에 낙뢰가 들어오게 되면 그 접지극 부근의 대지전위가 상승하고 다른 접지극에서 기기로 뇌 써지가 역류하기도 하고 피뢰기와 보호소자를 역섬락시켜 배전선측, 통신선측으로 뇌 써지가 흐른다. 한편 철탑이 건물의 옥상에 있는 경우는 피뢰침이 건물의 철골, 철근과 연결되어 있으므로 뇌써지는 건물에도 흐르고 그것도 접속되어 있는 기기의 지지물을 통하여 다른 접지계통에 유입된다.

  • PDF

Study on the Performance Characteristics of the Thermosyphon Used for the Vehicle Operated at Low Temperature Conditions (저온작동 조건에서 자동차용 써모사이폰의 성능특성에 관한 연구)

  • Lim, Taek-Kyu;Lee, Ho-Seong;Won, Jong-Phil;Cho, Chung-Won;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.510-515
    • /
    • 2012
  • The objective of this study is to investigate low temperature performance characteristics of the thermosyphon with/without wick. Thermosyphons using water as the working fluid are tested with variations of wick, charge amount of the working fluid, outdoor temperature, and heat load for the evaporator section at a low temperature. As a result, the heat transfer of thermosyphon was optimized at the charge amount of 40% and increased with the rise of the outdoor temperatures.