• Title/Summary/Keyword: 심장 판막

Search Result 786, Processing Time 0.021 seconds

Aortic Translocation for Complete Transposition of the Great Arteries with a Ventricular Septal Defect and Pulmonic Stenosis (심실 중격 결손과 폐동맥 협착을 동반한 완전 대혈관 전위에서 대동맥 전위술)

  • Jeong, In-Seok;Lee, Chang-Ha;Lee, Cheul;Lim, Hong-Gook;Kim, In-Sub;Youn, Hyo-Chul
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.476-479
    • /
    • 2008
  • The Rastelli operation has been a standard procedure for repairing complete transposition of the great arteries combined with a ventricular septal defect and pulmonary stenosis. Yet this procedure has several shortcomings, including the risk of incurring left ventricular outflow tract obstruction on long-term follow-up. In this regard, aortic translocation has recently been regarded as a potent alternative to Rastelli's operation. We report here on a case of complete transposition of the great arteries that was combined with an inlet-extended perimembranous ventricular septal defect and pulmonary stenosis in a 2-year-old boy. All the problems were successfully repaired using the aortic translocation technique. Postoperative echocardiography showed a straight and wide left ventricular outflow tract.

Intravascular Hemolysis after Prosthetic Valve Replacement (인공판막 치환수술후의 용혈)

  • Jang, Won-Chae;Lee, Gye-Yeong;Kim, Sang-Hyeong
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1556-1562
    • /
    • 1992
  • Forty two consecutive patients who had had valve replacement with St. Jude Medical prosthesis were studied on a view point of intravascular hemolysis. Patients were consisted of 14 mitral valve replacement, and 7 aortic valve replacement, and 21 double, mitral and aortic, valve replacement. Serum LDH, indirect bilirubin, GOT, hemoglobin levels and ret-iculocyte count were pursued in postopeative 1st day, 3rd day, 7th day, 14th day and 21th day. Postoperatively, all patients were not detected paravalvular leakage on the ech-ocardiographical study. The patients with double valve replacement revealed higher levels of LDH on postopeative 14th day[P<0 05] than those with single valve replacement. Among the patients with single valve replacement, the patients with aortic valve replacement revealed slightly higher levels of entire postopeative data, but considered insignificant. There was correlation between the severity of hemolysis and the size of replaced aortic valve. In the postoperative LDH levels, the patients with small sized-aortic valve[less than 21mm in diameter] replacement revealed higher levels of postoperative 3rd day, 7th day and 14th day than those with large size[more than 23mm in diameter]. The patients with high level LDH of greater than 800 WU /L on postoperative 7th day were 61.9%[26 of 42]. The high LDH frequency of DVR was 71.4%[15 of 21], MVR 50.0%[7 of 14] and AVR, 57.1%[4 of 7]. The level of LDH declined gradualiy thereafter through postoperative 3 weeks. In conclusion, intravascular hemolysis after prosthetic valve replacement was dependent on position of valve replacement and size of valve. And this study supports the conventional valve selection and usage in our hospital. The patients with subclinical hemolysis after valve replacement should be placed on a close observation.

  • PDF

Durability of the Ionescu-Shiley Valve in Mitral Position (이오네스큐 승모판막의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.246-255
    • /
    • 1989
  • A total and consecutive 291 patients of isolated single mitral valve replacement using the Ionescu-Shiley bovine pericardial xenograft valve operated on between October 1978 and June 1983 were retrospectively studied for the durability of the substitute valves based on the structural degeneration of primary tissue failure which had been proved on their re-replacement surgery. The mean age at the initial surgery was 32.4*12.5 years, and the operative mortality rate was 5.2 %. The early survivors of 276 patients were followed up for a total 1148.3 patient-years[mean\ulcornerD, 4.16*2.57 years]at the follow-up end of June 1988. They experienced 4 major late complications: 1.045 % thromboembolism/patient-year [pt-yr]; 0.871 % bleeding/pt-yr; 0.610% endocarditis/pt-yr; and 3.309% overall valve failure/pt-yr or 1.655% primary tissue failure/pt-yr. The actuarial survival rates were 89.4*2.2% and 87.7*2.5% at 5 and 10 years after initial surgery respectively. The probabilities of freedom from thromboembolism were 95.1*1.6% and 93.2*2.0% at 5 and 10 years after surgery. Nineteen patients underwent re-replacement of the Ionescu-Shiley valve because of primary tissue failure, and there was no operative mortality. The incidence of primary tissue failure was highest for the patients less than 15 years of age occurring in 9 out of 27 patients [33.3 %] or 8.68 %/pt-yr, while it was 4.0 % or 0.96 %/pt-yr for the rest of patients older than this age. The probabilities of freedom from primary tissue failure were 96.7*1.4 % and 84.2*3.8% at 5 and 9 years after surgery. The freedom from tissue failure increased as the age limits of cumulative younger patients were increased while it decreased as the age limits of cumulative older patients were decreased. Although it is clear that the Ionescu-Shiley valve would degenerate prematurely in young patients, the definite age limit could not be identified when the risk of early failure was significantly high.

  • PDF

The relation of the bioprosthetic valve failure to its calcification (조직판막의 실패와 석회화에 관한 연구)

  • 홍유선
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1001-1012
    • /
    • 1989
  • In 1968, Carpentier and his associates introduced glutaraldehyde as a compound for preparing cardiac tissue valve, and this technique has provided a considerably more suitable and durable tissue valve substitute. To increase further durability of valve tissue, Reis and his colleagues designed a flexible stent to reduce the stress on the heterogeneous tissue valve mounted. However with the advent of more innovative mechanical valve currently, many bioprosthetic valves are being substituted by mechanical valves at our department of cardiothoracic surgery because of bioprosthetic valve failure. Main cause of bioprosthetic valves failure were calcification or/and tear of tissue valves. The purpose of this retrospective study is to clarify the relationship between the patients clinical profile during implantation of tissue valves and pathologic features of the failed bioprosthetic valve. From March, 1982 through June, 1988, 53 bioprosthetic heart valves that had been ex-planted from 45 patients at the department of cardiac surgery of Yonsei University Hospital were subjected to this study. The patients were 10 to 65 year-old [mean age: 30.3 yr] with 17 males and 28 females. Re-replacements of prosthetic valves were carried out twenty nine in mitral position, eight in aortic position and eight in both aortic and mitral position simultaneously. The grading and location for calcification of valves were verified by radiograms. The calcification of the explanted valves leaflets was graded from 0 to 4 plus according to Cipriano and associates method. The types of tear and perforation of leaflet were classified into four types as Ishihara has adopted initially in 1981. In younger age group under thirty three years, explanted tissue valves were significantly more affected in terms of grades of severity of valve calcification as compared with older age group [p < 0.035]. Valve calcification appeared more severe in male as compared to female [p< 0.002]. Ionescu-Shiley bovine pericardial bioprosthetic valves showed more severe calcification than Hancock porcine tissue valves [p< 0.035]. Calcium deposit was found very prevalent at the area of commissural attachment [86 % of all]. Type I of valve rupture was shown to be related with simultaneous calcification. However, the relation of explanted valve position, duration of implanted prosthetic valve, atrial fibrillation and anticoagulant therapy to the severity of bioprosthetic valve calcification were not significantly clear statistically [p > 0.05].

  • PDF

Early and Late Results after Mitral Valve Replacement (승모판막 치환후 조기및 장기추적결과)

  • 김명인
    • Journal of Chest Surgery
    • /
    • v.25 no.2
    • /
    • pp.149-157
    • /
    • 1992
  • Total 145 cases mitral vlave replacement were performed in Department of Thoracic and Cardiovascular Surgery in Chungnam National University Hospital during the period from May 1983 to July 1991. Sixty-one patients were male and 84 patients were female and the range of age was from 12 to 66 years old with the mean of 37.9[$\pm$11.6] years. Valvular lesions were 49 cases of mitral stenosis, 18 cases of regurgitation and 78 cases of combined lesion. Used valve were Ionescu-Shiley[42 cases], Bjork-Shiley[49 cases], Inact[6 cases], St. Jude Medical[11 cases] and CarboMedics[37 cases]. Mean size of valve was 29.8$\pm$1.68mm. Early morality was 13.8%[20 cases] and low output syndrome was most common cause[9 cases]. Age, functional classification and biventricular hypertrophy were risk factors. All survived cases were followed up without missing. Mean follow up period were 3 years and 3 months. Total 14 cases of death[9.7%] were observed and heart failure, unexplained sudden death and bleeding were the causes in that order. Common late complications were heart failure and bleeding related with anticoagulation. Actuarial survival rate at 5 years was 83$\pm$5.4% in overall, 78$\pm$7.2% in tissue valve group, 87$\pm$6.8% in mechanical valve group. The actuarial freedom rate from thromboembolism at 7 years was 89$\pm$8.3% in overall, 86$\pm$9.9% in tissue valve group and 97$\pm$1.9% in mechanical valve group. Actuarial freedom rate from bleeding at 5 years with anticoagulation was 88.9$\pm$4.2% in overall, 96$\pm$3.9% in tissue valve group, 86$\pm$4.6% in mechanical valve group. Reoperation was done in 3 cases with heart failure with tricuspid regurgitation and thromboembolism in 2 cases. The functional status of survived cases was I or II.

  • PDF

Clinical Results of Mitral Valve Repair (승모판막질환의 판막재건술36례 성적)

  • Jang, Bong-Hyeon;Han, Seung-Se;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.70-81
    • /
    • 1988
  • From January 1962 to March 1987, 97 patients underwent operation for mitral valve disease. Of these patients, 61 [62.9%] required mitral valve replacement. Thirty-six patients [37.1%] had mitral valve repair. The mean age was 26.9*11.6 years [range 5 months to 48 years]. There were 32 [88.9%] cases of rheumatic valve disease, 4 [11.1%] cases of congenital mitral valve disease. Valve dysfunction was classified into three types: type I [normal leaflet motion], 6 patients; type II [prolapsed leaflet], 1 patient; type III [restricted leaflet motion], 29 patients. Twenty-nine patients [80.6%] had pure or predominant stenosis and 7[19.4%] had pure regurgitation. No patient was in NYHA functional class I. Three patients [16.7%] were in functional class II, 15[83.3%] were in functional class II. The techniques used included closed mitral commissurotomy [16 patients], open mitral commissurotomy [13 patients], localized Wooler type annuloplasty [4 patients], suture repair of leaflet defect [3 patients], chordal shortening [1 patient], Carpentier ring annuloplasty [1 patient], and fenestration of fused chordae [1 patient]. There were two perioperative deaths [5.6%], related to left ventricular failure and reoperation. The survivors were followed up for 94 patient-years [mean 4.68*5.54 years]. One late death [1.1*1.1% per patient-year] occurred and was valve related. Reoperation was required in 3 patients, of whom 2 were deaths. There was 1 case [1.1*1.1% per patient-year] of thromboembolism. No patient received anticoagulant after operation. At 10 year, 92*7.4% of the patients were still alive. The actuarial survival rate of patients free of valve-related complication was 79*6.4% at 6 years, 27*12.1% at 11 years. After surgery, 18 patients [88.9%] were in NYHA functional class I or II.

  • PDF

Extended Unroofing Procedure for Creation of a New Ostium for an Anomalous Right Coronary Artery Originating from the Left Coronary Sinus - A case report - (좌관상동맥동에서 이상 기시하는 유관상동맥 질환에서 새로운 개구부를 만드는 Extended Unroofing 수술 - 1예 보고 -)

  • Park, Jung-Sik;Lee, Hyang-Lim;Kim, Keun-Woo;Choi, Chang-Hyu;Lee, Jae-Ik;Jean, Yang-Bin;Park, Kook-Yang;Park, Chul-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.102-105
    • /
    • 2008
  • An anomalous origin of the coronary artery with subsequent coursing between the great vessels is a rare congenital heart defect that may cause myocardial ischemia and sudden death. Several surgical techniques have been described to address this defect. An extended unroofing procedure to create an alternative ostium for the right coronary artery was successfully carried out in a patient having an anomalous origin of the right coronary artery. The newly constructed orifice was widely patent 3 months later, without any episodes of myocardial ischemia or aortic regurgitation.

Friction Force Microscopy Analysis of Diamond-like Carbon Films (다이아몬드상 카본 박막의 Friction Force Microscopy 분석)

  • Choi, Won-Seok;Lee, Jong-Hwan;Song, Beom-Young;Heo, Jin-Hee;You, Jin-Soo;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.181-181
    • /
    • 2008
  • DLC (Diamond-like Carbon) 박막은 높은 내마모성과 낮은 마찰 계수, 화학적 안정성 및 적외선 영역에서의 높은 투과율과 낮은 광 반사도, 높은 전기저항과 낮은 유전율, 전계방출특성 등 여러 가지 장점을 가진 물질이다[1]. 최근에는 DLC 박막의 여러 장점들과 산과 염기 유기용매에 대한 화학적 안정성으로 인하여 인조관절에서 인공심장의 판막에 이르기까지 의공학 관련 부품소재로 응용되고 있으며 내구성과 안정성에 있어서 탁월한 성능을 보여주고 있다. 또한 DLC 박막의 높은 경도와 낮은 마찰 계수, 부드러운 박막 표면 (수nm의 RMS 거칠기)의 장점을 살려 마그네틱 미디어와 하드디스크의 슬라이딩 표면에 사용되어지고, MEMS (Micro-Electro Mechanical System) 소자와 MMAs (Moving Mechanical Assemblies)의 고체윤활코팅으로 활용하여 미세기계의 내구성과 성능 향상을 도모할 수 있다. 이와 같이 DLC 박막은 다양한 분야에 응용되고 있으며, 박막이 지닌 여러 가지 장점들로 인하여 더 많은 분야에 응용될 가능성을 지닌 물질이다. 그러나 수 ${\mu}m$이상의 두께에서 박막이 높은 잔류응력 (residual stress)을 가지고, 열에 취약하여 이의 개선에 관한 연구들이 진행되어 지고 있다 [2]. 따라서 사용되는 목적에 따라 용도에 맞는 양질의 DLC 박막을 합성하기 위해선 합성 장치의 개발과 다양한 실험을 통한 최적의 합성조건 도출 등의 노력이 요구된다. 또한 DLC 박막 합성시의 여러 가지 증착 방법에 따른 박막 물성에 대한 재현성 확보 및 박막 증착에 관한 명확한 메커니즘 규명이 아직까지는 불분명하여 이에 관한 연구가 시급하다. 따라서 본 연구에서는 MEMS 소자와 MMAs의 고체윤활코팅으로 사용가능한 DLC 박막을 RF PECVD (Plasma Enhanced Vapor Deposition) 방식으로 합성하고 후열처리 온도에 따른 DLC 박막의 마찰계수 변화를 박막에 훼손을 주지 않는 FFM (Friction Force Microscopy) 방식을 사용하여 분석하였다.

  • PDF

Detection of Main Components of Heart Sound Using Third Moment Characteristics of PCG Envelope (심음 포락선의 3차 모멘트를 이용한 심음의 주성분 검출)

  • Quan, Xing-Ri;Bae, Keun-Sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.3001-3008
    • /
    • 2013
  • To diagnose the cardiac valve abnormalities using analysis of phonocardiogram, first of all, accurate detection of S1, S2 components is needed for heart sound segmentation. In this paper, a new method that uses the third moment characteristics of an envelope of the PCG is proposed for accurate detection of S1 and S2 components of the heart sound with cardiac murmurs. The envelope of the PCG is obtained from the short-time energy profile, and its third moment profile with slope information is used for accurate time gating of the S1, S2 components. Experimental results have shown that the proposed method is superior to the conventional second moment method for detection of S1 and S2 regions from the heart sound signals with cardiac murmurs.

Clinical Evaluation of the Angell-Shiley Porcine Xenograft Valve (Angell-Shiley 판막의 임상적 평가)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.75-82
    • /
    • 1986
  • The use of the Angell-Shiley porcine xenograft cardiac valve was limited in number at Seoul National University Hospital chiefly because of the cessation of supply from the manufacturer, Forty-eight Angell-Shiley valves along with the 5 other mechanical or tissue valves were used in 46 patients during the period from 1977 to 1980, and a total of consecutive cases was studied for their early and long-term clinical results. The operative mortality rate was 4.3%; no death after single and 2 deaths after double valve replacement within 30 days of surgery. The 44 early survivors were followed up for a total of 171.6 patient-years and a mean of 46.8$\pm$31.1 months. Four died during the follow-up period with a linealized late mortality rate of 2.33%/patient-year. Four patients had experienced 5 episodes of thromboembolism and one died; a linealized incidence of 2.91% emboli/patient-year. A single case each had a bleeding complication related to the anticoagulants, 0.58% bleeding/patient-year, and prosthetic valve endocarditis, 0.58% endocarditis/patient-year. The clinical improvement was excellent by 70% of the survivors having no cardiac symptoms at the end of the follow-up. The actuarial survival rates were 89.9$\pm$4.9% at 5 years and 69.2$\pm$15.0% at 9 years after surgery. The probabilities of freedom from thromboembolic complication were 92.3$\pm$5.5% and 80.9$\pm$9.0% at 5 and 9 years after surgery. And, the probability of freedom from overall valve failure was 83.4$\pm$6.3% at 5 years and it declined sharply down to 55.9$\pm$22.2% at 9th year of the follow-up. These results are comparable with those in the major reports, except a more accelerated and time-related increases in valve failure after 5 or 6 years after operation with the Angell-Shiley valve. The durability of the xenograft tissue valve remains as the most important debate and the need of more durable tissue valves was also discussed.

  • PDF