• Title/Summary/Keyword: 심박신호

Search Result 230, Processing Time 0.033 seconds

The Effect of Acupressure Thermal Bed Combined with Acupressure and Thermal Therapy on Brain waves and ANS (지압과 온열 요법이 조합된 지압온열침대가 뇌파와 자율신경에 미치는 영향)

  • Jang, Seok-Woo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.179-186
    • /
    • 2020
  • The purpose of this study was to investigate the effects on the bio signal of brain waves and pulse waves using acupressure thermal bed combined with acupressure and thermal therapy. Forty healthy adults were divided into 20 experimental groups using combinatorial stimulation beds and 20 non-irritating controls. As a result of the experiment, the EEG was significantly increased in the delta wave and theta wave in the experimental group, and the alpha wave and beta wave decreased significantly. The pulse wave increased the parasympathetic activity index in the experimental group and the heart rate decreased. There was no difference in the control group. This change in EEG can be seen as a combination stimulation bed having a sleep-inducing effect, and a change in pulse wave can seen as having a relaxing effect. This study is expected to be used as basic data for the development of various combination stimulators and functional bed products.

A Study on the Characteristics of Heart Rate Variabilities In Nornal Subjects and Hemiplegic patients (정상인과 편마비 환자의 심박변동신호의 특성에 관한 연구)

  • Jeong, Kee-Sam;Shin, Kun-Soo;Lee, Jeong-Whan;Ahn, Juhn;Chon, Joong-Son;Kim, Jun-Soo;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.285-290
    • /
    • 1997
  • In this paper, the power spectral analysis and the fractal analysis of heart rate variability(HRV) were performed to evaluate the effects of brain lesion on cardiovascular system and autonomic function for 24 normal subjects and 22 hemiplegic patients. The ECG and respiration signals were recorded at tilt angles of $0^{\circ}$ and $70^{\circ}$ for 5 and 6 minutes successively under the condition of frequency controlled respiration (0.25Hz). For normal subjects, HR, LF component, HF component and fractral dimension of HRV were distinctly changed after orthostatic stress, whereas, for hemiplegic patients, those were little changed. Complexity and variability of heart rate of patients were smaller than those of normal subjects. Sympathetic tone of patients was higher than that in normal subjects. All of these results support that autonomic disorder and cardiovascular disturbance accompanied by brain lesion could be assessed by the power spectral analysis and fractal analysis of HRV.

  • PDF

The process of estimating user response to training stimuli of joint attention using a robot (로봇활용 공동 주의 훈련자극에 대한 사용자 반응상태를 추정하는 프로세스)

  • Kim, Da-Young;Yun, Sang-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1427-1434
    • /
    • 2021
  • In this paper, we propose a psychological state estimation process that computes children's attention and tension in response to training stimuli. Joint attention was adopted as the training stimulus required for behavioral intervention, and the Discrete trial training (DTT) technique was applied as the training protocol. Three types of training stimulation contents are composed to check the user's attention and tension level and provided mounted on a character-shaped tabletop robot. Then, the gaze response to the user's training stimulus is estimated with the vision-based head pose recognition and geometrical calculation model, and the nervous system response is analyzed using the PPG and GSR bio-signals using heart rate variability(HRV) and histogram techniques. Through experiments using robots, it was confirmed that the psychological response of users to training contents on joint attention could be quantified.

Analysis of Change Rate of SBP and DBP Estimation Fusion Algorithm According to PTT Measurement change PPG Pulse Wave Analysis (PPG 맥파 분석의 PTT 측정변화에 따른 SBP, DBP 추정 융합 알고리즘 변화율 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.35-40
    • /
    • 2020
  • Recently, devices such as smart watches capable of measuring small biosignals have been released. Body composition, blood pressure, heart rate, and oxygen saturation can be easily obtained. However, the part that is not trusted by the user is accuracy. These biosignals are sensitive to the external environment and have large fluctuations depending on the conditions inside the subject's body. Blood pressure measurements, in particular, still give different results, depending on how the conditions in the body are handled. Therefore, in this study, PPG was analyzed to measure PTT at two points of 80% and 100%, the highest in PTT measurement. The effect of the measured value on SBP and DBP was analyzed and a method was proposed to increase the accuracy. As a result of the study, the measured value of PTT at 80% of the peak PPG is more effective in estimating blood pressure of SBP and DBP than the value measured at 100%. In the regression analysis of the rate of change blood pressure estimation, the coefficient of determination of SBP (80%) was 0.6946, and DBP (100%) was 0.547.

The Hearing Ability of Coralfish Chromis notatus to Low Frequency Sound 2. The Auditory Critical Ratio and Hearing Index (저주파음에 의한 자리돔의 청각 능력 2. 청각 임계비 및 청각능력지수)

  • 이창헌;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.4
    • /
    • pp.314-321
    • /
    • 2000
  • In order to obtain the fundamental data on the auditory thresholds of fishes for catching method using low frequency sound, the auditory thresholds of coralfish Chromis notatus were measured in the presence of masking noise in the spectrum level range of 73~83dB re l$\mu$Pa/√Hz by heartbeat conditioning technique using pure tones coupled with a delayed electric shock. Critical ratios were about 23~41dB at measurement frequency, The critical ratio increased almost linearly with increasing frequency from 500Hz. The noise spectrum level at the start of masking was about 60~65dB. This suggests that hearing of coralfish is masked in the natural environment with the noise spectrum level above 60dB. The sound pressure level of which the signal sound of 300Hz is recognized by coralfish under the ambient noise is above 88dB and the critical ratio of them is above 23dB. The hearing index of coralfish with ambient noise was 81.

  • PDF

HRV Evaluation under Stress Condition by Using Patch Type Bipolar Heart Activity Monitoring System (패치형 바이폴라 심장활동 모니터링 시스템을 이용한 스트레스 상태의 HRV 평가)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Lee, Kang-Hwi;Choi, Hee-Jung
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • In this study, we have developed the patch type HAMS (Heart Activity Monitoring System) which is non-restricted, non-awarable and non-invasive. The module using wireless telecommunication to receive the ECG (electrocardiogram) signal at the computer has mobility which it easily monitors the heart activity of subjects in no time for long term at any time and places. We developed the small patch type electrode which can be attached on the chest. Also the reliability and moving artifact of ECG signal measured by this electrode have been verified. Using HAMS, we measured the HRV (Heart Rate Variability) parameters, the questionnaire evaluation for anxiety and stress and the amount of stress hormone (cotisol) to evaluate the stress effect in HRV on the same subject. As a result of comparing the values under non stressed and stressed condition, there was significant difference on many parameters. And the parameter highly related with stress on Pearson's Correlation Coefficient has been examined. These show that using HAMS is able to evaluate the function of autonomic nervous system. Therefore, we can predict heart problem in daily life by using HAMS. Also we expect that this module can be applied for more application as health monitoring system.

  • PDF

Comparative Study of Subjective Mental Workload Assessment Techniques for the Evaluation of ITS-oriented Human-Machine Interface Systems (지능형 교통체계 기반 인간-기계 인터페이스 시스템 평가를 위한 정신적부하 측정방법의 비교 연구)

  • Cha, Doo-Won;Park, Peom
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.3
    • /
    • pp.45-58
    • /
    • 2001
  • Subjective mental workload assessment technique becomes a standard human factors and human-machine interface evaluation tool for the evaluation of ITS(Intelligent Transport Systems)-oriented information systems as well as the drivers visual activity analysis, physiological indices(GSR, EEG, ECG, etc.), secondary task performance, reaction time. vehicle control parameters(speed, steering behavior, accelerator control) that are widely applied for transportation and vehicle systems to evaluate the safety, to decide the system or design alternatives, and to establish the design guidelines. This paper reviewed and compared the most globally employed four mental workload assessment techniques that have been designed for the use of various human-machine systems and ITS-oriented in-vehicle information systems. NASA-TLX(National Aeronautics and Space Administration-Task Load Index). SWAT(Subjective Workload Assessment Technique), MCH(Modified Cooper-Harper) scale, and recently developed RNASA-TLX(Revision of NASA-TH) were compared in terms of sensitivity and subjective evaluations to derive the human-machine interface evaluation guidelines for the application of ITS-oriented in-vehicle information systems. Then, experiment results supported that RNASA-TLX is the prospective tool for the mental workload assessment of ITS-oriented in-vehicle information systems.

  • PDF

Comparison of Human Sensibility in Driving Simulator and Roller-Coaster Simulator (자동차 시뮬레이터와 롤러코스터 시뮬레이터 주행에 따른 감성 비교)

  • 민병찬;전효정;강인형;성은정;김철중;윤석준
    • Science of Emotion and Sensibility
    • /
    • v.6 no.3
    • /
    • pp.13-20
    • /
    • 2003
  • In an experimental study, we assessed human sensibility in terms of psychophysiological response according to change of speeds (40, 70, 100km/h) in a driving simulator and application of motion fitters (washout filter, non-washout later) in a roller coaster simulator. For the driving and roller coaster simulators, a group of 12 healthy men in their twenties and a group of 8 healthy men in their twenties, respectively, participated. Participants each completed a simulator sickness questionnaire (SSQ), a subjective assessment of sensations of pleasantness, tension, and arousal, and perception of speed. Physiological signals were measured by 1/f fluctuation of EEG (electroencephalogram), ECG (electrocardiogram), and GSR (galvanic skin response). These were measured pre-to-post under the experimental conditions for each simulator. Subjective pleasantness, tension, arousal, and perception of speed and physiological responses indicating a feeling of pleasantness by 1/f fluctuation were higher for the roller coaster simulator than those measured for low speed driving in the driving simulator. The mean frequency of alpha band (8-l3㎐) in EEG increased with exposure to the driving simulator relative to that for the roller coaster simulator. Heart rate variability and GSR were significantly changed between pre- and post- under each condition in the driving and roller coaster simulators. The data suggest that subjective sensibility was elevated according to gain of speed and variety of simulator motion, and physiological responses were activated with increased speed.

  • PDF

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

The Change of Vascular Reactivity in Rat Thoracic Aorta 3 Days after Acute Myocardial Infarction (흰쥐에서 급성심근경색 3일 후 흉부 대동맥 혈관 반응성의 변화)

  • Lee, Sub;Roh, Woon-Seok;Jang, Jae-Seok;Bae, Chi-Hoon;Park, Ki-Sung;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.576-587
    • /
    • 2009
  • Background: The up-regulation of the nitric oxide (NO)-cGMP pathway might be involved in the change of vascular reactivity in rats 3 days after they suffer acute myocardial infarction. However, the underlying mechanism for this has not been clarified. Material and Method: Acute myocardial infarction (AMI) was induced by occluding the left anterior descending coronary artery (LAD) for 30 min (Group AMI), whereas the sham-operated control rats were treated similarly without LAD occlusion (Group SHAM), The concentration-response relationships for phenylephrine (PE), KCl, acetylcholine (Ach) and sodium nitroprusside (SNP) were determined in the endothelium intact E(+) and endothelium denuded E(-) thoracic aortic rings from the rats 3 days after AMI or a SHAM operation. The concentration-response relationships of PE in the E(+) rings from the AMI rats were compared with those relationships in the rings pretreated with nitric oxide synthase (NOS) inhibitor $N{\omega}$-nitro-L-arginine methyl ester (L-NAME) or the cyclooxygenase inhibitor indomethacin. The plasma nitrite/nitrate concentrations were checked via a Griess reaction. The cyclic GMP content in the thoracic aortic rings was measured by radioimmunoassay and the endothelial nitric oxide synthase (eNOS) mRNA expression was assessed by real time PCR. Result: The mean infarct size (%) in the rats with AMI was $21.3{\pm}0.62%$. The heart rate and the systolic and diastolic blood pressure were not significantly changed in the AMI rats. The sensitivity of the contractile response to PE and KCl was significantly decreased in both the E(+) and E(-) aortic rings of the AMI group (p<0.05). L-NAME completely reversed these contractile responses whereas indomethacin did not (p<0.05). Moreover, the sensitivity of the relaxation response to Ach was also significantly decreased in the AMI group (p<0.05). The plasma nitrite and nitrate content (p<0.05), the basal cGMP content (p<0.05) and the eNOS mRNA expression (p=0.056) in the AMI rats were increased as compared with the SHAM group. Conclusion: Our findings indicate that the increased eNOS activity and the up-regulation of the NO-cGMP pathway can be attributed to the decreased contractile or relaxation response in the rat thoracic aorta 3 days after AMI.