• Title/Summary/Keyword: 심박산소포화도

Search Result 77, Processing Time 0.035 seconds

Correlational Analysis of Supine Position Time and Sleep-related Variables in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡 증후군에서 앙와위 자세시간과 수면관련변인 간 상관관계 분석)

  • Kim, Si Young;Park, Doo-Heum;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon
    • Sleep Medicine and Psychophysiology
    • /
    • v.24 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Objectives: A supine sleep position increases sleep apneas compared to non-supine positions in obstructive sleep apnea syndrome (OSAS). However, supine position time (SPT) is not highly associated with apnea-hypopnea index (AHI) in OSAS. We evaluated the correlation among sleep-related variables and SPT in OSAS. Methods: A total of 365 men with OSAS were enrolled in this study. We analyzed how SPT was correlated with demographic data, sleep structure-related variables, OSAS-related variables and heart rate variability (HRV). Multiple linear regression analysis was conducted to investigate the factors that affected SPT. Results: SPT had the most significant correlation with total sleep time (TST ; r = 0.443, p < 0.001), followed by sleep efficiency (SE ; r = 0.300, p < 0.001). Snoring time (r = 0.238, p < 0.001), time at < 90% SpO2 (r = 0.188, p < 0.001), apnea-hypopnea index (AHI ; r = 0.180, p = 0.001) and oxygen desaturation index (ODI ; r = 0.149, p = 0.004) were significantly correlated with SPT. Multiple regression analysis revealed that TST (t = 7.781, p < 0.001), snoring time (t = 3.794, p < 0.001), AHI (t = 3.768, p < 0.001) and NN50 count (t = 1.993, p = 0.047) were associated with SPT. Conclusion: SPT was more highly associated with sleep structure-related parameters than OSAS-related variables. SPT was correlated with TST, SE, AHI, snoring time and NN50 count. This suggests that SPT is likely to be determined by sleep structure, HRV and the severity of OSAS.

Effect of Virtual Reality Distraction on Pain and Anxiety in Children during Local Anesthesia (소아환자의 국소마취 시 Virtual Reality 주의분산이 통증 및 두려움에 미치는 효과)

  • Kim, Doosoo;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan;Ahn, Jihye
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.95-104
    • /
    • 2021
  • The purpose of this study was to evaluate the effect of virtual reality distraction on pain and anxiety in children during local anesthesia. Local anesthesia was administered to 3 groups: a control group without distraction, a group watching TV, and a group using a virtual reality device. The pulse rate and oxygen saturation rate were measured before and at the time of local anesthesia to assess the patients' pain and anxiety, and the Wong-Baker Faces Pain Rating Scale was completed after local anesthesia. The group using the virtual reality device had a significantly lower heart rate change and lower Wong-Baker Faces Pain Rating Scale score than those in the control group and the group watching TV (p < 0.05). The greatest difference in heart rate change and Wong-Baker Faces Pain Rating Scale score, between the control and virtual reality distraction groups, was seen in 5 - 7-year-olds and a Frankl's behavior rating scale grade of 3. The virtual reality device alleviated pain and reduced anxiety in children during local anesthesia.

Effects of Kangaroo Care on Physical Development and Adaptation of External Environment of Prematurity, and Maternal Role Confidence who Delivered Premature Infants (캥거루식 접촉이 미숙아 신체발달과 외부환경 적응 및 어머니의 역할수행 자신감에 미치는 효과)

  • Lee, Ji-Won;Eo, Yong-Sook;Han, Jung Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.128-137
    • /
    • 2016
  • This study aimed to investigate the effect of kangaroo care on physical development adaptation of external environment of prematurity, and maternal role confidence of those who delivered preterm infants. The subjects were 38 preterm infants and mothers with cesarean section delivery in the hospital, located at B city. Eighteen premature infants were assigned to the kangaroo care (KC) group or the control group (CG). Data were collected between June 2013 and June 2015. KC was given 3 times a day (60 min at a time) and performed a total of 10 times. The physical development indicator (weight, height, and head circumference) as well as the adaptation of external environment (temperature, heart rate, oxygenation) of preterm infants were checked before the start of the program. Following the initial measurement, the program was performed, and measurements were taken again at the end of the program. For measurement of maternal role confidence, structured self-reported questionnaires were performed. The results showed that the KC group had a lower oxygenation compared with the CG (t=2.27, p=.02); however, the physical development indicator (weight t=-0.83, p=.21, height t=-0.34, p=.37, head circumference t=1.29, p=.10) and maternal role confidence (t=-0.41, p=.34) were not significantly compared with the CG. The results of this study suggest that the practice of KC helps the adaptation of external environment of preterm infants

Comparison of the Clinical Performance between Two Pulse Oximeters in NICU: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$ (신생아 중환자실에서 맥박산소측정기의 감지도 비교: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$)

  • Lee, Heun-Ji;Choi, Jang-Hwan;Min, Sung-Ju;Kim, Do-Hyun;Kim, Hee-Sup
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.245-249
    • /
    • 2010
  • Purpose: Numerous false alarms by pulse oximetry, which is widely used in neonatal intensive care unit, can delay response to true alarms. Masimo $SET^{(R)}$ was introduced lately, to overcome false alarms by motion. We compared the clinical performance of two devices (Nellcor $N-595^{(R)}$ and Masimo $SET^{(R)}$) for the evaluation of the false alarm frequency during usual motion artifacts and stable state. Methods: A total of 20 preterm infants weighing 1,000-2,500 g were enrolled in the study. The sensors of two devices were placed on the different feet on the same infants, and both devices were programmed to emit an alarm for episode of hypoxemia (SpO2$\leq$85%). The false alarms were defined as episodes of poor correlation with ECG heart rate, poor waveforms, and the absence of obvious signs of hypoxia. We compared the frequency of false alarms between the two devices. Results: The mean chronological age was 20.8 days and the mean body weight was 1,668 g on the study day. The frequency of total false alarm was significantly fewer for Masimo $SET^{(R)}$ pulse oximetry (48 in Nellcor $N-595^{(R)}$, 27 in Masimo $SET^{(R)}$) although the false alarm during usual motion artifacts was not significantly between two devices (32 in Nellcor $N-595^{(R)}$, 19 in Masimo $SET^{(R)}$). Conclusion: The Masimo $SET^{(R)}$ pulse oximetry has fewer false alarm rates and identified more true hypoxic events than Nellcor $N-595^{(R)}$ pulse oximetry. Therefore, it is useful for adequate oxygen therapy and helps to decrease unnecessary handling by clinicians and nurses.

Effects of CP AP Therapy on Systemic Blood Pressure, Cardiac Rhythm and Catecholamines Concentration in Patients with Obstructive Sleep Apnea (폐쇄성 수면 무호흡에서 CPAP 치료가 전신성 혈압, 심조율 및 catecholamines 농도에 미치는 영향)

  • Kang, Ji-Ho;Lee, Sang-Haak;Choi, Young-Mee;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.715-723
    • /
    • 2000
  • Background : Obstructive sleep apnea syndrome (OSAS) affects systemic blood pressure and cardiac function. The development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac rhythm, suggests that recurrent hypoxia and arousals from sleep may increase a sympathetic nervous system activity. Continuous positive airway pressure (CPAP) therapy has been found to be an effective treatment of OSAS. However, only a few studies have investigated the cardiovascular and sympathetic effects of CPAP therapy. We evaluated influences of nasal CPAP therapy on the cardiovascular system and the sympathetic activity in patients with OSAS. Methods : Thirteen patients with OSAS underwent CPAP therapy and were monitored using polysomnography, blood pressure, heart rate, presence of arrhythmia and the concentration of plasma catecholamines, before and with CPAP therapy. Results: The apnea-hypopnea index (AHI) was significant1y decreased (p<0.01) and the lowest arterial oxygen saturation level was elevated significantly after applying CPAP (p<0.01). Systolic blood pressure tended to decrease after CPAP but without statistical significance. Heart rates during sleep were not significantly different after CPAP. However, the frequency and number of types of arrhythmia decreased and sinus bradytachyarrhythmia disappeared after CPAP. Although there was no significant difference in the level of plasma epinephrine concentration, plasma norepinephrine concentration significantly decreased after CPAP (p<0.05). Conclusion : CPAP therapy decreased the apnea-hypopnea index, hypoxic episodes and plasma norepinephrine concentration. In addition, it decreased the incidence of arrhythmia and tended to decrease the systemic blood pressure. These results indicate that CPAP may play an important role in the prevention of cardiovascular complications in patients with OSAS.

  • PDF

The Influence of Obstructive Sleep Apnea on Systemic Blood Pressure, Cardiac Rhythm and the Changes of Urinary (폐쇄성 수면 무호흡이 전신성 혈압, 심조율 및 요 Catecholamines 농도 변화에 미치는 영향)

  • Lo, Dae-Keun;Choi, Young-Mee;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.153-168
    • /
    • 1998
  • Background: The existing data indicate that obstructive sleep apnea syndrome contributes to the development of cardiovascular dysfunction such as systemic hypertension and cardiac arrhythmias, and the cardiovascular dysfunction has a major effect on high long-term mortality rate in obstructive sleep apnea syndrome patients. To a large extent the various studies have helped to clarify the pathophysiology of obstructive sleep apnea, but many basic questions still remain unanswered. Methods: In this study, the influence of obstructive sleep apnea on systemic blood pressure, cardiac rhythm and urinary catecholamines concentration was evaluated. Over-night polysomnography, 24-hour ambulatory blood pressure and ECG monitoring, and measurement of urinary catecholamines, norepinephrine (UNE) and epinephrine (UEP), during waking and sleep were undertaken in obstructive sleep apnea syndrome patients group (OSAS, n=29) and control group (Control, n=25). Results: 1) In OSAS and Control, UNE and UEP concentrations during sleep were significantly lower than during waking (P<0.01). In UNE concentrations during sleep, OSAS showed higher levels compare to Control (P<0.05). 2) In OSAS, there was a increasing tendency of the number of non-dipper of nocturnal blood pressure compare to Control (P=0.089). 3) In both group (n=54), mean systolic blood pressure during waking and sleep showed significant correlation with polysomnographic data including apnea index (AI), apnea-hypopnea index (AHI), arterial oxygen saturation nadir ($SaO_2$ nadir) and degree of oxygen desaturation (DOD). And UNE concentrations during sleep were correlated with AI, AHI, $SaO_2$ nadir, DOD and mean diastolic blood pressure during sleep. 4) In OSAS with AI>20 (n==14), there was a significant difference of heart rates before, during and after apneic events (P<0.01), and these changes of heart rates were correlated with the duration of apnea (P<0.01). The difference of heart rates between apneic and postapneic period (${\Delta}HR$) was significantly correlated with the difference of arterial oxygen saturation between before and after apneic event (${\Delta}SaO_2$) (r=0.223, P<0.001). 5) There was no significant difference in the incidence of cardiac arrhythmias between OSAS and Control In Control, the incidence of ventricular ectopy during sleep was significantly lower than during waking. But in OSAS, there was no difference between during waking and sleep. Conclusion : These results suggested that recurrent hypoxia and arousals from sleep in patients with obstructive sleep apnea syndrome may increase sympathetic nervous system activity, and recurrent hypoxia and increased sympathetic nervous system activity could contribute to the development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac function.

  • PDF

USE OF ENFLURANE FOR CHILDREN WHO FAIL TO RESPOND PROPERLY TO ORAL CHLORAL HYDRATE (Chloral Hydrate 경구투여 후 진정 효과가 나타나지 않은 소아환자에 대한 Enflurane의 사용)

  • Lee, Sang-Min;Yoon, Hyng-Bae;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.513-519
    • /
    • 1999
  • Chloral hydrate is one of the most widely used sedative agents to control the difficult to treat young age group in the dental clinic. We are often frustrated to see the patient still awake and cry with agitation even after far more than the normal onset time. In such a case, the patient has to be rescheduled for another sedation visit with different agents and/or routes which greatly disappoints the guardians. This case report presents a sedative regimen that can possibly help the clinician complete scheduled treatment without postponement. We have tried sleep induction with Enflurane (1-1.5vol%) for 60 seconds to 37 patients of those who failed to respond properly to the dose(70mg/kg)of oral Chloral hydrate. The average age and weight of the patients was 34.3 months(22-43mo.) and 14.9kg(11-21kg) respectively. It is suggested that sleep induction with low dose Eflurane produced a stable state during dental treatment with respect to vital sign and behavior. Evidence of adverse effect was not detected or reported during and/or after the procedures.

  • PDF

The Effects of Preemptive Analgesia of Morphine and Ketorolac on Postoperative Pain, Cortisol, $O_2$ Saturation and Heart Rate (Morphine과 Ketorolac의 선행진통법이 수술 후 통증, 코티졸, 산소포화도 및 심박동 수에 미치는 효과)

  • Seo, Yun-Ju;Yoon, Hae-Sang
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.5
    • /
    • pp.720-729
    • /
    • 2008
  • Purpose: This study investigated the preemptive analgesic effects of Morphine and Ketorolac on postoperative pain, cortisol, $O_2$ saturation and heart rate for the first 24 hr after abdominal surgery. Methods: Data collection was performed from April 1 to September 30, 2006. Forty patients undergoing a gastrectomy under general anesthesia were randomly allocated to the experimental or control group. The experimental group (20 patients) was administered Morphine and Ketorolac approximately 1 hr prior to skin incision, but the control group (20 patients) was administered Morphine and Ketorolac at peritoneum closure through a patient-controlled analgesia (PCA) pump. Postoperative pain, blood pressure, heart rate, cortisol, $O_2$ saturation, frequency of the PCA button pressed and doses of additional analgesics were observed through post operative 24 hr. Collected data was analyzed using t-test, $X^2$ test, repeated measures ANOVA, and Bonferroni methods. Results: Postoperative pain, cortisol, the frequency of PCA button pressed, and dose of additional analgesics of the experimental group were significantly lower than the control group. There were no statistical differences in blood pressure, heart rate and $O_2$ saturation between the experimental group and control group. Conclusions: We concluded that administration of morphine and ketorolac at 1 hr prior to skin incision resulted in decreasing postoperative pain, but it didn't affect blood pressure, heart rate or $O_2$ saturation for 24 hr after abdominal surgery.

The Effect of Low Dose Lidocaine on Fentanyl-Induced Cough, Mean Arterial Pressure, Heart Rate, Oxygen Saturation and Dizziness in Inhalation Anesthesia (흡입성 전신마취에서 저용량의 리도카인이 펜타닐-유도성 기침, 평균동맥압, 심박동수, 산소포화도 및 어지럼증에 미치는 영향)

  • Lee, Keon Young;Yoon, Haesang
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.4
    • /
    • pp.275-281
    • /
    • 2012
  • Purpose: This study was performed to evaluate the effect of low-dose lidocaine on fentanyl-induced cough and hemodynamic changes under general anesthesia. This research was a randomized trial design and performed using a double-blind method. Methods: Data collection was performed from October 22, 2008, to May 4, 2009. One hundred and thirty two patients were randomly assigned to control group (Con G) and experimental group (Exp G) using a table of random numbers. Exp G (n=66) were administered 0.5 mg/kg lidocaine and Con G (n=66)) were administered saline. The occurrence of cough and vital sign were recorded within one minute after fentanyl bolus by an anesthesiologist. Collected data were analyzed using Repeated measures ANOVA using SPSS for Windows (Version 17.0). Results: The incidence of cough in Exp G was 13.6%, while Con G was 53%. The incidence cough in Exp G was significantly lower compared to Con G (p<.001). Lidocaine seemed not to suppress mean arterial pressure (p=.145), heart rate (p=.508), and oxygen saturation (p=.161). Conclusion: Intravenous administration of 0.5 mg/kg lidocaine seems to suppress fentanyl-induced cough without affecting mean blood pressure, heart rate and oxygen saturation. Therefore, we recommend intravenous 0.5 mg/kg lidocaine administration to suppress fentanyl-induced cough under general anesthesia.

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Nam, Jae-Hyun;Chang, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.67-71
    • /
    • 2007
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, Sp02, and heart rate.

  • PDF