• Title/Summary/Keyword: 심박변위도

Search Result 7, Processing Time 0.019 seconds

Evaluation of Immediate Effects of an Electrical Massager on Stress Relaxation Using the Heart Rate Variability(HRV) (심박변위도를 이용한 전동 안마기의 단기적 스트레스 완화 효과 평가)

  • Kim, Yong-Dae;Chang, Yun-Seung;Choi, Dong-Hyuk;Lee, Hyun-Ju;Tae, Ki-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.75-81
    • /
    • 2010
  • The purpose of this study was to investigate the short-term effects of electrical massager on stress-related parameters including heart rate variability (HRV), heart rate (HR) using the photoplethysmogram (PPG) signal with motion artifact correction. Twenty healthy subjects were randomly allocated to receive a 15-min section of three types ((1) resting mode (control group), (2) light massage mode, (3) strong massage mode). Results indicated that self-report, VAS (Visual Analog Scale) significantly decreased for two massage modes after massage except control group. In strong massage mode, it was associated with significant increases in HF, but significant decreases in LF and LH/HF ratio compared with the light massage mode. For all outcomes, similar changes were not observed in the control group. Also, the result founded that mean HR of all groups decrease. We conclude that electrical massager reduces perceived stress and improves adaptive autonomic response to stress in healthy adults.

Analysis and Processing of Driver's Biological Signal of Workload (작업 부하에 따른 운전자의 생체신호 처리 및 특성 분석)

  • Heo, Yun Seok;Lee, Jae-Cheon;Kim, Yoon Nyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.87-93
    • /
    • 2015
  • The accidents caused by drivers while driving are considered as the major causes along with other causes such as conditions of roads, weather and cars. In this study, we investigated the driver's workloads under three different driving conditions (Weather, Driving time zone, and Traffic density) through analyzing biological signals obtained from a car driving simulator system. The proposed method is able to detect R waves and R-R interval calculation in the ECG. Heart rate variability (HRV) was investigated for the time domain to determine the changes in driver's conditions.

Characteristics of Heart Rate Variability Derived from ECG during the Driver's Wake and Sleep States (운전자 졸음 및 각성 상태 시 ECG신호 처리를 통한 심장박동 신호 특성)

  • Kim, Min Soo;Kim, Yoon Nyun;Heo, Yun Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.136-142
    • /
    • 2014
  • Distinct features in heart rate signals during the driver's wake and sleep states could provide an initiative for the development of a safe driving systems such as drowsiness detecting sensor in a smart wheel. We measured ECG from health subjects ($23.5{\pm}2.5$ in age) during the wake and drowsiness states. The proposed method is able to detect R waves and R-R interval calculation in the ECG even when the signal includes in abnormal signals. Heart rate variability(HRV) was investigated for the time domain and frequency domains. The STD HR(0.029), NN50(0.044) and VLF power(0.0018) of the RR interval series of the subjects were significantly different from those of the control group (p < 0.05). In conclusion, there are changes in heart rate from wake to drowsiness that are potentially to be detected. The results in our study could be useful for the development of drowsiness detection sensors for effective real-time monitoring.

A Study of Noncontact Heartbeat and Respiration Detection Using the Doppler Radar (도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 검출에 관한 연구)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • In this paper, a 2.4 GHz doppler radar system consisting of a doppler radar sensor and a baseband module were designed to detect heart beat and respiration signal without direct skin contact. The doppler radar system emits RF signal of 2.4 GHz toward human chest, and then detects phase modulation of the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from I/Q channels of the doppler radar system are applied to the pre-processing circuit, the amplification circuit, and the offset circuit of the baseband module. The designed system was tested on mouse, rabbit and mankind, which have different range of heart rates and respiration signals, to evaluate detection accuracy of the system. ECG acquisition system and respiration transducer were used to generate the reference signal. In our experiments, a performance of detection were found to be high in the case that the subject stays still. In this paper, we confirmed that non-contact heart beat and respiration detection using the doppler radar has the possibility and limitation according to distance, cardiopulmonary activities, range of heart rates and respiration.

Detection of Heartbeat and Respiration Signal Using the Aircushion and the Frequency Domain Filter (에어쿠션 및 주파수 영역 필터를 이용한 호흡 및 심박 신호 검출)

  • Kim, Joo-Han;Cho, Sung-Pil;Shin, Jae-Yeon;Lee, Jeon;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.33-42
    • /
    • 2010
  • In this study, we have proposed a simple cardiorespiratory monitoring method based on displacements of human body which occurs due to periodic heartbeat and breathing. The proposed system consists of an aircushion, pressure sensing hardware and heartbeat and respiration signals extraction algorithm. The aircushion was used for unconstrained measurement of the respiration and heartbeats without a sensor attached on the subject's skin surface. The displacements of subject sitting on the aircushion cause small pressure variations. These variations are amplified and filtered with the pressure sensing hardware. Finally, heart rate and respiration rate are extracted by signal processing algorithm based on frequency domain filter. To evaluate the performance, extracted respiration and heart rate from proposed system were compared with conventional methods. The average sensitivity of respiration and heart rate are 98.67% and 99.24%, respectively. These results show the proposed method has advantages of installing and processing simplicity so as to be used easily in unconstrained respiration and heart rate monitoring in daily life.

심근조영심초음파에서 심장의 움직임을 보정한 비침습적 심근관류모델의 정량적 평가

  • 이재훈;김희중;정남식;임세중;김기황
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.49-49
    • /
    • 2003
  • 목적 : 심초음파는 비침습적이므로 반복적으로 정확히 심질환의 경과를 관찰하여 치료효과 및 수술시기를 정할 수 있는 검사로서 임상적으로 매우 유용하다. 실시간 심근조영심초음파에 의한 time intensity 평가는 부위별로 수행됨으로 연속적으로 위치하는 관심영역이 intensity에 있어 심장의 움직임 변화에 영향을 받는다. Time intensity 곡선의 최적의 곡선맞춤을 위해 주기적인 심장 운동 매개변수를 조합해 기존의 모델을 보정한 안정적인 측정방법을 제시한다. 방법 : 심장의 운동에 의한 특징적인 정보를 설명하기 위해 기존의 문헌에 제시된 지수 함수에 주어진 심박수로 만들어진 시간에 관한 일반적인 정형파 함수를 추가한다. C(t) = A[1 - exp($\beta$t)] + Dsine(2$\pi$ft + $\theta$) C(t): videointensity A: plateau videointensity (blood volume) $\beta$: capillary blood velocity (rate constant of rise in videointensity) t: pulsing interval (ms) D: displacement from the periodic variance of the curve (estimated motion field from the ejection point for the ratio between systole and diastole) f: heart rate $\theta$: transit time issue A $\times$ $\beta$ : myocardial blood flow 관상동맥의 관류 데이터에 대한 실험이 펄스간격에 대한 비디오 세기로 수행되었다. 그리고 이러한 결과들이 the sum of squares due to error, R square, root mean squared error로 평가되었다. 결과 : 실험결과, 주기적인 심장의 움직임과 심박출 시점으로부터의 변위를 잘 기술하고 곡선에서의 측정 점들이 예측된 심장 움직임에 따라 성공적으로 표시되었다. 뿐만 아니라 보정된 모델이 현저한 적합도의 향상을 보여주었다. 결론 : 제시된 접근방법은 각각의 측정에서 심장 운동 영역의 변화에 독립적이며 측정 시점에 의해 영향받지 않고 심근 관류의 안정적인 측정이 가능하다. 심장의 움직임에 관한 매개변수를 조합한 모델로 곡선접합을 수행함으로써 관류의 정량적 정보를 좀더 정확하게 얻을 수 있으며 임상적 이용을 가능하게 할 것으로 기대된다.

  • PDF

Kinemetic analysis of a thumping security motion with an expandable barton (경호원의 삼단봉 머리치기 동작의 운동학적 분석)

  • Kim, Yong-Hak;Kim, Sin-Hye;Jung, Sung-Bae
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.93-109
    • /
    • 2013
  • This research is mainly based on the experimental result due to seek different outcomes whena certain security motion with a paticular gear is applied in a plausible confrontational situation. For the purpose of this research an Expandable Baton, which is one of the most commonsecurity equipments, was chosen to be applied in a situation of hitting a person's head. Alsothe results will be studied in the view of Kinematic theory. To demonstrate, 10 students who were majeored in Escort Crane studies at 'H' university werechosen as testees. The participants were grouped into two-one is practiced with the 'expanadable baton use program' and the other is pre-practiced. In this report two groups abovewill be reffered as 'group A' and 'group B' for conveniency. There were a number of differences and changes between two groups. Group B took more timethan the other group did. Group A spent about 0.428sec in section 'e2' and 0.230sec in section'e3' while Group B took 0.435sec, 0.232sec in each sections.To add on, more distinctive results were out when it was more focused on physical movements. Two gropus presented considerable changes- in an 'left-right' moving displacement-Group A;$2.16{\pm}0.9cm$ (left side), $3.78{\pm}1.42cm$ (right side), total $5.94{\pm}2.03cm$. Group B; $2.97{\pm}1.01cm$ (left side),$4.56{\pm}1.57cm$ (right side), total $7.53{\pm}2.13cm$.Continuously, different outcomeswere shown between two groups in a 'back and forth' moving displacement-Group A;$32.48{\pm}3.86cm$, $35.21{\pm}4.64cm$, total $69.36{\pm}5.72$. Group B; $34.50{\pm}6.12cm$, $37.04{\pm}3.70cm$, total $71.46{\pm}7.17cm$. Furthermore, changes in an 'up and down' moving displacement were - GroupA; $5.62{\pm}2.41cm$, $4.54{\pm}1.87cm$, total $10.11{\pm}1.57cm$. Group B; $6.33{\pm}1.78cm$, $4.86{\pm}1.85cm$,total $10.68{\pm}1.81cm$. To continue, there were few modifications of degree on participants' joints, espcially on 'Wristjoint', 'Elbow joint' and 'Shoulder joint', depend on different sections -Wrist joint;Group A; e1 $114.62{\pm}7.13$, e2 $68.27{\pm}6.37$, e3 $131.64{\pm}6.27$. Group B; e1 $112.62{\pm}6.13$, e2 $66.28{\pm}7.38$, e3$137.42{\pm}4.28$ and Elbow joint ; Group A e1 $132.31{\pm}6.55$, e2 $117.92{\pm}8.42$, e3 $144.41{\pm}6.32$. Group B; e1 $133.58{\pm}8.56$, e2 $114.45{\pm}8.21$, e3 $139.89{\pm}4.38$. Lastly, degree changes ofshoulder joint were; Group A; e1 $13.55{\pm}3.85$, e2 $131.42{\pm}11.24$, e3 $78.32{\pm}6.28$. Group B; e1$9.45{\pm}1.23$, e2 $136.74{\pm}13.21$, e3 $79.75{\pm}4.24$.