• Title/Summary/Keyword: 심미치과

Search Result 1,131, Processing Time 0.035 seconds

ORTHODONTIC TREATMENT THROUGH EXTRACT10N OF UPPER AND LOWER LATERAL TEETH (상하악 측절치 발거를 통한 전치부 총생의 치료)

  • Park, Sang-Hyun;Lee, Kwang-Hee;Kim, Dae-Eop;Lee, Jong-Seon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.547-552
    • /
    • 2001
  • Extracting mandibular incisors for orthodontic treatment may adversely affect the occlusion. However, when properly used, extraction of mandibular inciors is a selection for the correction of the malocclusion. Generally, treatment for crowding needs to select between nonextraction and four premolar extraction. Approaches for crowded mandibular incisors include distal movement of posterior teeth, lateral movement of canines, labial movement of incisors, interproximal enamel reduction, removal of premolars, removal of one or two incisors, and various combinations of the above. Extraction of incisors is used in case of crowding, anterior tooth size discrepancy, absent of maxillary lateral incisors, and ectopic eruption. But severe overjet. overbite, and space are the contraindication of it. A patient had severe crowding on upper anterior teeth, impacted upper left lateral incisor, palatal ectopic eruption of upper right incisor and severe crowding on lower anterior teeth. Lower lateral incisors are extracted for space availability and facial esthetics. We report the case of orthodontic treatment of upper and lower anterior crowding through extraction of lateral incisor.

  • PDF

IMPROPER USE OF RUBBER BANDS TREATING MAXILLARY MEDIAN DIASTEMA : A CASE REPORT (상악 정중이개 치료시 rubber band의 부적절한 사용)

  • Choi, Won-Hyuk;Kim, Eun-Jung;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.525-530
    • /
    • 2005
  • Maxillary median diastema is the term used when there is spacing between maxillary central incisors. The space between maxillary central incisors are often observed during ugly duckling stage. In most of the cases, as maxillary permanent canines erupt, it gradually disappears. Maxillary median diastema needs to be treated when there is up to 2mm of space between the incisors even after eruption of permanent canines or when there is 3mm of space, at least, before the eruption of the canines. Particulary, for the latter case, orthodontic treatment is recommended because not only the esthetic point of view but also to regain the eruption space for maxillary lateral incisors and canines. The appliance used for orthodontic treatment are removable appliances, using finger spring and etc, and fixed appliances, using rubber elastics and coil spring. If rubber band alone was used to treat median diastema without any other appliance such as band, tube or bracket, it will gradually move downward along the root surface. Then it will destroy the peridontal ligament and causes tooth mobility, extrusion, and avulsion. This report presents cases of damaged tooth due to improper use of rubber band when treating maxillary median diastema.

  • PDF

Submentoplasty for esthetic improvement of the neck-lower facial region : Two cases report (하안면과 경부의 심미성 증진을 위한 지방흡입술을 동반한 Submentoplasty 술식: 증례보고)

  • Park, Young-Ju;Nam, Jeong-Hun;Song, Jun-Ho;Yeon, Byung-Moo;Kim, Da-Young;Ahn, Jang-Hun;Gang, Tae-In;Kang, Hae-Jin;Kim, Jun-Hyun
    • The Journal of the Korean dental association
    • /
    • v.47 no.11
    • /
    • pp.750-757
    • /
    • 2009
  • Purpose : The purpose of this study is to evaluate the clinical availability of submentoplasty for esthethic improvement of the cervico-facial region of patients with obtuse chin-neck angle. Materials and methods : Case 1. We evaluate the changes of submental line length and chin-neck angle of 35-year-old woman with skeletal Class III and mandibular excess with excessive submental fat before and after surgery: Bilateral sagittal split ramus osteotomy(BSSRO) setback(5mm), Mandibular Angle Reduction, Reduction Malarplasty and Submentoplasty. In this case, It was done simultaneously with orthognathic surgery. Case 2. The changes of submental line length and chin-neck angle of 20-year-old man with skeletal class III and maxillary defiency were evaluated before surgery, at first surgery : Lefort I osteotomy(6mm posterior Impaction), BSSRO setback(9mm), Paranasal Augmentation and at second surgery: genioplasty(6mm advanced) with submentoplasty. In this case, submentoplasty and advancement genioplasty were done after 2 months post-operative periods. Results : Case 1. In case of the Skeletal Class III mandibular excess with submental fat deposit, It showed the improvement of submental angle and length of submental line after simultaneous submentoplasty. Submental angle is changed from $177^{\circ}$ (pre-op) to $151^{\circ}$ (post-op) and submental line length is changed from 8mm(pre-op) to 36mm(post-op). Case 2. The improvement of submental angle and length of submental line after delayed submentoplasty was aquired in case of the skeletal class III maxillary defiency. Submental angle is changed from $154^{\circ}$ (pre-op) to $161^{\circ}$ (first surgery) and to $153^{\circ}$ (second surgery) and submental line length is changed from 25mm(pre-op) to 19mm(first surgery) and to 23mm(second surgery). Conclusion : The results suggest that Submentoplasty is useful surgical procedure for esthethic improvement of the cervicofacial region of patients with obtuse chin-neck angle.

  • PDF

A Study on the Factors Giving Effects to Patient's Satisfaction in the Selection of Implant Operation (임플란트 시술선택에 있어 환자 만족도에 영향을 미치는 요인)

  • Kim, Gi-Ug;Choi, Sung-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4354-4359
    • /
    • 2010
  • The study performed questionnaire to the patients receiving implant operation, who visited dental clinics and hospitals(2 hospitals and 5 clinics) from Jul. 1, 2009 to Sep. 12, 2009 in order to study the factors giving effects to patient's satisfaction in the selection of implant. 145 questionnaire papers collected from patients were analyzed with SPSS12.0 program. The result revealed that the satisfaction with implant operation was usually normal when implant was operated because of tooth extraction due to dental caries and periodontal disease and it was usually high when implant was operated because of wound(P<0.05). When considering each cause of tooth extraction, the satisfaction with pronunciation function was usually normal(P<0.001), the satisfaction with functional part including foreign body sense was very low when the cause of operation was periodontal disease(P<0.01). The satisfaction with hospital environment depending on the cause of hospital selection was usually high when hospital was selected because of doctor's fame. It was low when hospital was selected because it was close to home(P<0.001). The satisfaction with the number of hospital visits depending on the number of implanted teeth was usually low when many teeth were implanted(P<0.01). The analysis on the satisfaction with tooth shape and color showed that the satisfaction was high when '1~2' teeth and 'more than 6' teeth were implanted(P<0.05). In order to improve patient's satisfaction with implant, it is necessary to recognize individual's oral status and request correctly. It is determined that proposal of operation period, number of hospital visits, function and expected aesthetic satisfaction degree will contribute to the improvement of mutual reliance between doctor and patient and post-operation satisfaction degree.

Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: A case report (적층가공을 이용한 임시의치 제작 및 기존방식의 임시의치와의 비교 증례)

  • Kim, Hyun-Ah;Lim, Hyun-Pil;Kang, Hyeon;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.483-489
    • /
    • 2019
  • With development of digital dentistry, the 3-dimensional (3D) manufacturing industry using computer-aided design and computer-aided manufacturing (CAD/CAM) has grown dramatically in recent years. Denture fabrication using digital method is also increasing due to the recent development of digital technology in dentistry. The 3D manufacturing process can be categorized into 2 types: subtractive manufacturing (SM) and additive manufacturing (AM). SM, such as milling is based on cutting away from a solid block of materal. AM, such as 3D printing, is based on adding the material layer by layer. AM enables the fabrication of complex structures that are difficult to mill. In this case, additive manufacturing method was applied to the fabrication of the resin-based complete denture to a 80 year-old patient. During the follow-up periods, the denture using digital method has provided satisfactory results esthetically and functionally.

The use of implant-assisted removable partial denture in the partially edentulous maxilla with a few unilateral remaining teeth and implant overdenture in the mandible: A case report (상악 편측 소수 잔존치에서 임플란트 융합 국소의치와 하악 임플란트 피개의치의 수복 증례)

  • Yun, Yina;Kim, Hyun-Ah;Park, Sangwon;Park, Chan;Jang, Woohyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.515-522
    • /
    • 2021
  • Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the denture when there are a few residual teeth. When the lateral force applied to the tooth abutment and implant surveyed crown is minimized, the horizontal and rotational movement of the denture is significantly reduced which is an effective method that can improve the address in patients who complain of reduced retention and stability of their dentures. In this case, a small number of implants were placed to fabricate an implant-assisted removable partial denture with implant surveyed crown in the maxilla and implant overdenture with Locator® attachment in the mandible to improve the retention, stability, and support of the dentures. The patient was satisfied with both functional and aesthetic aspects after the final dentures were delivered.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

A study of Korean Norm about tooth size and ratio in Korean adults with normal occlusion (한국성인 정상교합자의 치아크기와 비율에 관한 연구)

  • Kim, Dae-Sik;Kim, Young-Jun;Choi, Jae-Hoon;Han, Jong-Hoon
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.505-515
    • /
    • 2001
  • The purpose of this study was to measure the average tooth size of Korean with normal occlusion. According to the study, the average tooth ratios between the upper and lower teeth which could assure the proper ovebite, overjet and good interdigitation were calculated. The normal occluson sample of this study consisted of 43 Korean male adults and 51 Korean female adults. Among them, 22 Korean male adults and 51 Korean female adults were from KAO(Korean Association of Orthodontists), 21 Korean male adults were from Department of Orthodontics, College of Dentistry, Yonsei University. The results from this study were as follows : 1 The average tooth size of Korean Norm classified by male and female was measured. 2. The average tooth size of Korean male adults with normal occlusion was significantly larger than that of Korean female adults except upper and lower first molars. (p<0.05) 3. The tooth ratio which could Predict the proper overbite and overjet in anterior teeth and proper occlusion in posterior teeth was calculated. 1) Sum of inciosrs = 4:2.97 2) Neff's anterior coefficient = 1.22 3) Bolton's anterior ratio = 78.29%, overall ratio = 91.14% 4. A positive correlation was observed between the sum of lower anterior incisors and the sum of unilateral canine and premolars In each jaw. Based this correlation, the regression equation was made which could Predict the sum of unerupted unilateral canine and premolars in mired dentition. 1) Sum of unilateral unerupted upper canine and premolars' width = 10.435018 + 0.513346 ${\times}$ (sum or lower 4 incisors' width) 2) Sum of unilateral unerupted lower canine and premolars' width = 9.654002 + 0.502565 ${\times}$ (sum of lower 4 incisors' width)

  • PDF

Evaluation of shade guide using digital shade analysis system (색조 선택 시스템을 이용한 shade guide의 색조 분석)

  • Lee, Seung-Taek;Lee, Jong-Hyuk;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.

WEAR AND CHEMICAL DEGRADATION OF ESTHETIC RESTORATIVE MATERIALS (차세대 레진 개발을 위한 광중합형 복합레진의 화학적 분해와 마모에 관한 연구)

  • Yang, Kyu-Ho;Choi, Eun-Young;Choi, Nam-Ki;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.557-568
    • /
    • 2005
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution(0.1N NaOH). The brands studied were MetafilCX(Sun medical, Japan) Solitaire 2(Heraeus Kulzer, USA), Composan LCM(Promedica, Germany), DenFil(Vericom, Korea). The results were as follows: 1. The mass loss of each brand was 0.74~7.94% and highest value in Metafil($7.94{\pm}0.39%$). 2. The sequence of the degree of degradation layer depth was in descending order by Metafil, Solitaire 2, DenFil, Composan LCM. There were significant differences between Metafil and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Metafil, Solitaire 2, Composan LCM, DenFil. There were significant differences among the materials(p<0.05). 4. On SEM, destruction of bonding between matrix and filler and on CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Metafil, Solitaire 2, Composan LCM and DenFil. There were significant differences among the materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.491, p<0.05) and Vicker's hardness number and maximum wear depth (r=-0.942, p<0.05) were relatively high. These results indicate that hydrolytic degradation and wear may consider as a evaluation factors of composite resins.

  • PDF