Park, Sang-Hyun;Lee, Kwang-Hee;Kim, Dae-Eop;Lee, Jong-Seon
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.4
/
pp.547-552
/
2001
Extracting mandibular incisors for orthodontic treatment may adversely affect the occlusion. However, when properly used, extraction of mandibular inciors is a selection for the correction of the malocclusion. Generally, treatment for crowding needs to select between nonextraction and four premolar extraction. Approaches for crowded mandibular incisors include distal movement of posterior teeth, lateral movement of canines, labial movement of incisors, interproximal enamel reduction, removal of premolars, removal of one or two incisors, and various combinations of the above. Extraction of incisors is used in case of crowding, anterior tooth size discrepancy, absent of maxillary lateral incisors, and ectopic eruption. But severe overjet. overbite, and space are the contraindication of it. A patient had severe crowding on upper anterior teeth, impacted upper left lateral incisor, palatal ectopic eruption of upper right incisor and severe crowding on lower anterior teeth. Lower lateral incisors are extracted for space availability and facial esthetics. We report the case of orthodontic treatment of upper and lower anterior crowding through extraction of lateral incisor.
Journal of the korean academy of Pediatric Dentistry
/
v.32
no.3
/
pp.525-530
/
2005
Maxillary median diastema is the term used when there is spacing between maxillary central incisors. The space between maxillary central incisors are often observed during ugly duckling stage. In most of the cases, as maxillary permanent canines erupt, it gradually disappears. Maxillary median diastema needs to be treated when there is up to 2mm of space between the incisors even after eruption of permanent canines or when there is 3mm of space, at least, before the eruption of the canines. Particulary, for the latter case, orthodontic treatment is recommended because not only the esthetic point of view but also to regain the eruption space for maxillary lateral incisors and canines. The appliance used for orthodontic treatment are removable appliances, using finger spring and etc, and fixed appliances, using rubber elastics and coil spring. If rubber band alone was used to treat median diastema without any other appliance such as band, tube or bracket, it will gradually move downward along the root surface. Then it will destroy the peridontal ligament and causes tooth mobility, extrusion, and avulsion. This report presents cases of damaged tooth due to improper use of rubber band when treating maxillary median diastema.
Park, Young-Ju;Nam, Jeong-Hun;Song, Jun-Ho;Yeon, Byung-Moo;Kim, Da-Young;Ahn, Jang-Hun;Gang, Tae-In;Kang, Hae-Jin;Kim, Jun-Hyun
The Journal of the Korean dental association
/
v.47
no.11
/
pp.750-757
/
2009
Purpose : The purpose of this study is to evaluate the clinical availability of submentoplasty for esthethic improvement of the cervico-facial region of patients with obtuse chin-neck angle. Materials and methods : Case 1. We evaluate the changes of submental line length and chin-neck angle of 35-year-old woman with skeletal Class III and mandibular excess with excessive submental fat before and after surgery: Bilateral sagittal split ramus osteotomy(BSSRO) setback(5mm), Mandibular Angle Reduction, Reduction Malarplasty and Submentoplasty. In this case, It was done simultaneously with orthognathic surgery. Case 2. The changes of submental line length and chin-neck angle of 20-year-old man with skeletal class III and maxillary defiency were evaluated before surgery, at first surgery : Lefort I osteotomy(6mm posterior Impaction), BSSRO setback(9mm), Paranasal Augmentation and at second surgery: genioplasty(6mm advanced) with submentoplasty. In this case, submentoplasty and advancement genioplasty were done after 2 months post-operative periods. Results : Case 1. In case of the Skeletal Class III mandibular excess with submental fat deposit, It showed the improvement of submental angle and length of submental line after simultaneous submentoplasty. Submental angle is changed from $177^{\circ}$ (pre-op) to $151^{\circ}$ (post-op) and submental line length is changed from 8mm(pre-op) to 36mm(post-op). Case 2. The improvement of submental angle and length of submental line after delayed submentoplasty was aquired in case of the skeletal class III maxillary defiency. Submental angle is changed from $154^{\circ}$ (pre-op) to $161^{\circ}$ (first surgery) and to $153^{\circ}$ (second surgery) and submental line length is changed from 25mm(pre-op) to 19mm(first surgery) and to 23mm(second surgery). Conclusion : The results suggest that Submentoplasty is useful surgical procedure for esthethic improvement of the cervicofacial region of patients with obtuse chin-neck angle.
Journal of the Korea Academia-Industrial cooperation Society
/
v.11
no.11
/
pp.4354-4359
/
2010
The study performed questionnaire to the patients receiving implant operation, who visited dental clinics and hospitals(2 hospitals and 5 clinics) from Jul. 1, 2009 to Sep. 12, 2009 in order to study the factors giving effects to patient's satisfaction in the selection of implant. 145 questionnaire papers collected from patients were analyzed with SPSS12.0 program. The result revealed that the satisfaction with implant operation was usually normal when implant was operated because of tooth extraction due to dental caries and periodontal disease and it was usually high when implant was operated because of wound(P<0.05). When considering each cause of tooth extraction, the satisfaction with pronunciation function was usually normal(P<0.001), the satisfaction with functional part including foreign body sense was very low when the cause of operation was periodontal disease(P<0.01). The satisfaction with hospital environment depending on the cause of hospital selection was usually high when hospital was selected because of doctor's fame. It was low when hospital was selected because it was close to home(P<0.001). The satisfaction with the number of hospital visits depending on the number of implanted teeth was usually low when many teeth were implanted(P<0.01). The analysis on the satisfaction with tooth shape and color showed that the satisfaction was high when '1~2' teeth and 'more than 6' teeth were implanted(P<0.05). In order to improve patient's satisfaction with implant, it is necessary to recognize individual's oral status and request correctly. It is determined that proposal of operation period, number of hospital visits, function and expected aesthetic satisfaction degree will contribute to the improvement of mutual reliance between doctor and patient and post-operation satisfaction degree.
Kim, Hyun-Ah;Lim, Hyun-Pil;Kang, Hyeon;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug
The Journal of Korean Academy of Prosthodontics
/
v.57
no.4
/
pp.483-489
/
2019
With development of digital dentistry, the 3-dimensional (3D) manufacturing industry using computer-aided design and computer-aided manufacturing (CAD/CAM) has grown dramatically in recent years. Denture fabrication using digital method is also increasing due to the recent development of digital technology in dentistry. The 3D manufacturing process can be categorized into 2 types: subtractive manufacturing (SM) and additive manufacturing (AM). SM, such as milling is based on cutting away from a solid block of materal. AM, such as 3D printing, is based on adding the material layer by layer. AM enables the fabrication of complex structures that are difficult to mill. In this case, additive manufacturing method was applied to the fabrication of the resin-based complete denture to a 80 year-old patient. During the follow-up periods, the denture using digital method has provided satisfactory results esthetically and functionally.
Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the denture when there are a few residual teeth. When the lateral force applied to the tooth abutment and implant surveyed crown is minimized, the horizontal and rotational movement of the denture is significantly reduced which is an effective method that can improve the address in patients who complain of reduced retention and stability of their dentures. In this case, a small number of implants were placed to fabricate an implant-assisted removable partial denture with implant surveyed crown in the maxilla and implant overdenture with Locator® attachment in the mandible to improve the retention, stability, and support of the dentures. The patient was satisfied with both functional and aesthetic aspects after the final dentures were delivered.
Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.
Kim, Dae-Sik;Kim, Young-Jun;Choi, Jae-Hoon;Han, Jong-Hoon
The korean journal of orthodontics
/
v.31
no.5
s.88
/
pp.505-515
/
2001
The purpose of this study was to measure the average tooth size of Korean with normal occlusion. According to the study, the average tooth ratios between the upper and lower teeth which could assure the proper ovebite, overjet and good interdigitation were calculated. The normal occluson sample of this study consisted of 43 Korean male adults and 51 Korean female adults. Among them, 22 Korean male adults and 51 Korean female adults were from KAO(Korean Association of Orthodontists), 21 Korean male adults were from Department of Orthodontics, College of Dentistry, Yonsei University. The results from this study were as follows : 1 The average tooth size of Korean Norm classified by male and female was measured. 2. The average tooth size of Korean male adults with normal occlusion was significantly larger than that of Korean female adults except upper and lower first molars. (p<0.05) 3. The tooth ratio which could Predict the proper overbite and overjet in anterior teeth and proper occlusion in posterior teeth was calculated. 1) Sum of inciosrs = 4:2.97 2) Neff's anterior coefficient = 1.22 3) Bolton's anterior ratio = 78.29%, overall ratio = 91.14% 4. A positive correlation was observed between the sum of lower anterior incisors and the sum of unilateral canine and premolars In each jaw. Based this correlation, the regression equation was made which could Predict the sum of unerupted unilateral canine and premolars in mired dentition. 1) Sum of unilateral unerupted upper canine and premolars' width = 10.435018 + 0.513346 ${\times}$ (sum or lower 4 incisors' width) 2) Sum of unilateral unerupted lower canine and premolars' width = 9.654002 + 0.502565 ${\times}$ (sum of lower 4 incisors' width)
Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.
Journal of the korean academy of Pediatric Dentistry
/
v.32
no.3
/
pp.557-568
/
2005
The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution(0.1N NaOH). The brands studied were MetafilCX(Sun medical, Japan) Solitaire 2(Heraeus Kulzer, USA), Composan LCM(Promedica, Germany), DenFil(Vericom, Korea). The results were as follows: 1. The mass loss of each brand was 0.74~7.94% and highest value in Metafil($7.94{\pm}0.39%$). 2. The sequence of the degree of degradation layer depth was in descending order by Metafil, Solitaire 2, DenFil, Composan LCM. There were significant differences between Metafil and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Metafil, Solitaire 2, Composan LCM, DenFil. There were significant differences among the materials(p<0.05). 4. On SEM, destruction of bonding between matrix and filler and on CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Metafil, Solitaire 2, Composan LCM and DenFil. There were significant differences among the materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.491, p<0.05) and Vicker's hardness number and maximum wear depth (r=-0.942, p<0.05) were relatively high. These results indicate that hydrolytic degradation and wear may consider as a evaluation factors of composite resins.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.