• Title/Summary/Keyword: 심미적 인상

Search Result 63, Processing Time 0.026 seconds

An Investigation on Non-Relevance Criteria for Image in Failed Image Search (이미지 검색 실패에 나타난 비적합성 평가요소 규명에 관한 연구)

  • Chung, EunKyung
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.50 no.1
    • /
    • pp.417-435
    • /
    • 2016
  • Relevance judgment is important in terms of improving the effectiveness of information retrieval systems, and it has been dominant for users to search and use images utilizing internet and digital technologies. However, in the field of image retrieval, there have been only a few studies in terms of identifying relevance criteria. The purpose of this study aims to identify and characterize the non-relevance criteria from the failed image searches. In order to achieve the purpose of this study, a total of 135 participants were recruited and a total of 1,452 criteria items were collected for this study. Analyses and identification on the data set found thirteen criteria such as 'topicality', 'visual content', 'accuracy', 'visual feature', 'completeness', 'appeal to user', 'focal point', 'bibliographic information', 'impression', 'posture', 'face feature', 'novelty', and 'time frame'. Among these criteria, 'visual content' and 'focal point' were introduced in this current study, while 'action' criterion identified in previous studies was not shown in this current study. When image needs and image uses are analyzed with these criteria, there are distinctive differences depending on different image needs and uses.

The treatment of an edentulous patient with conventional complete denture and CAD/CAM complete denture (Conventional한 방식과 CAD/CAM System을 이용한 완전 무치악 환자 동시 수복 증례)

  • Cho, Sungyoon;Lee, Joonseok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.42-49
    • /
    • 2020
  • In patients with fully edentulous jaw, treatment of complete dentures should be carried out in many stages when following the conventional methods. Therefore there were disadvantages such as multiple visits to dental clinic is inevitable. In addition, errors caused by polymerization shrinkage, which happens during the fabrication of denture, and difficulties in reproduction of damaged or lost denture were considered as disadvantages. But nowadays, computer-aided design and computer-aided manufacturing (CAD/CAM) system is widely used in dentistry and it has begun to expand its spectrum in manufacturing complete dentures. Using CAD/CAM system to fabricate complete dentures can reduce the number of patient's visit and clinical chair time, since taking impression, recording jaw relation, and selection of artificial teeth are performed at the same time during the first visit, and delivering of dentures during the second visit is possible. In addition, because 3D-Printing technology is used, errors by polymerization shrinkage can be reduced. Among the companies that fabricate complete dentures using CAD/CAM system, DENTCA CAD/CAM denture (DENTCA Inc., Los Angeles, CA, USA) is the most commercialized company. In this case, we treated patients of complete dentures using conventional complete denture method and DENTCA CAD/CAM denture system in the same patient. We would like to report this case because we have achieved good results not only in functional aspects of pronunciation, chewing, and swallowing but also in aesthetic aspects.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

The attrition pattern in Angle Class III malocclusion with facial astmmetry (안면비대칭을 동반한 Angle III급 부정교합자의 교모양상)

  • Son, Woo-Sung;Jeon, Eun-Ye;Kim, Sung-Jo
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.549-557
    • /
    • 1997
  • This study was designed to investigate the attrition pattern in Angle Class III malocclusion with facial asymmetry. The sample consisted of three groups, the 20 subjects of normal occlusion group(Group I), the 12 subjects of class III malocclusion without facial asymmetry group(Group II) and 17 subjects of Class III malocclusion with facial asymmetry group(Group III). Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date processing. Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date Processing. All attrition areas were measured 2 times and the average value was used for data processing The data were statistically analyzed by SAS program. The results of this study were as follows. 1. Total attrition area in Group I was larger than in Group II and III. 2. There was no significant difference in attrition area between right and left side in each group, but attrition area in Group III was larger than in Group I and II. 3. In Group I, Maxillary attrition area was larger than mandibular attrition area, but in Group ll and III, there was no significant difference in attrition area between maxilla and mandible. 4. In Group III, the attrition area of deviated side was target than undeviated side 5. There was no significant difference in attrition area between chewing side and non-chewing side in each group. 6. The total attrition area was unaffected by gender.

  • PDF

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.

Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report (양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례)

  • Seojune Choi;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Implant assisted removable partial denture (IARPD) has been practiced in various forms for a long time, and among them, implant surveyed crown RPD is gaining predictability as well as being considered as a treatment option for patients with anatomical and financial disadvantages. The position of implant could be divided as posterior placement or anterior placement according to the purpose of the treatment and should be planned in consider to the alveolar ridge of patient, anticipated prognosis of remaining teeth, and opposing dentition. This case report describes a treatment for mandibular Kennedy class I partial edentulous patient with two implant-supported surveyed crown and implant assisted removable partial denture. Given the difficulty of posterior placement in this patient and the prognosis of the residual teeth, the plan was to place two implants in close proximity to the residual teeth, which were placed in the planned position, angle, and depth using guided surgery. The process of fabricating the fixed prosthesis was carried out in parallel with the maxillary edentulous tooth arrangement process to increase predictability, and when fabricating the localized tooth, the implant was designed in a form that allows the patient to perform functional movements by preventing excessive loading as the last supporting tooth, and was fabricated through a secondary impression process. Each treatment procedure was proceeded as planned, with aesthetically and functionally satisfactory results for both patient and operator.

THE STUDY OF FRACTURE STRENGTH OF PORCELAIN LAMINATE VENEER WITH VARIOUS LINGUAL EXTENTION LENGTH WHEN LNCISAL RESTORING (Porcelain Laminate veneer 절연 피복시 설측 연장 길이에 따른 파절강도의 연구)

  • Park, Johng-Han;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.746-754
    • /
    • 1996
  • The purpose of this study was to evaluate the fracture strength of porcelain laminate veneer with various lingual extention length when incisal restoring. Sixty recently extracted, intact maxillary incisors were used and stored in a physiologic saline solution from the time of extraction. Seating form was preparation at the labial surface of each tooth with a water-cooled round diamond bur. Standard block was formed with 32 gauge and 24 gauge wax at tooth labial and lingual surface. Lingual extention length differed according to each group. (group I : 0.5mm, group II : 1 mm, group III : 2mm, group IV : 0mm) All tooth specimens were impressioned with examix(GC Inc., Japan). Refractory cast were maked with refractory die material(Ceramco Inc., U.S.A.) Laminate porcelain (Ceramco II Veneer porcelain, Ceramco Inc., U.S.A.) was condensed in refractory die cast and baked according to the manufacturer's recommendations. Each surface was contoured with low speed diamond bur according to guide block. All porcelain specimens were sandblasted and ultrasonically cleaned in distlled water for 3 minutes. Then, all porcelain specimen were etched with 8% hydrofluoric acid for 5 minutes. Sixty specimens were bonded with composite resin cement(Choice Porcelain Veneer System, Bisco Inc., U.S.A.) according to manufacture's directions. The fracture loads of the specimen were measured by Instron universal testing machine. The mean values of fracture loads for the groups were statistically compared by Duncan's multiful range test. The result were as follows : Mean fracture strengths of each group were 86.95Mpa in no lingual extention group, 44.98Mpa in 0.5mm lingual extention group, 27.47Mpa in 1mm lingual extention group, 19.61Mpa in 2mm lingual extention group. There was a statistically significant difference between all group(p<0.01).

  • PDF

'All-on-4' fixed implant supported prosthesis restoration using digital workflow: a case report (Digital workflow를 활용한 'All-on-4' 임플란트 지지 고정성 보철물 수복 증례)

  • Sungwoo Ju;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Kung-Rock Kwon;Hyeong-Seob Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.316-327
    • /
    • 2023
  • In the case of fully edentulous patients with severe alveolar bone resorption, the consideration of 'All-on-X' implant-supported fixed prosthesis after placing four or more implants in the anterior maxilla is possible. Recent advancements in digital dentistry have enabled systematic and predictable treatment in all phases, including diagnosis, surgery, and prosthesis fabrication. By incorporating digital dentistry techniques such as digital complete denture, implant surgical guides, facial scanning into the conventional restoration process, it is possible to reduce the complexity of the prosthesis fabrication and effectively achieve the transition from provisional prosthesis to definitive prosthesis in terms of both aesthetics and function.

Comparative observations of lingualized occlusion and monoplane occlusion in the treatment of severe atrophy of edentulous mandible (심한 하악 치조골 흡수를 보이는 환자에서 설측 교두 교합과 단일평면 교합을 비교 관찰한 의치 수복 증례)

  • Ahn, Gyo-zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.127-136
    • /
    • 2018
  • The patient who has severely absorbed residual ridges, treatments are challenging to satisfy many factors: support, retention, stability, etc. The neutral zone or monoplane occlusion with non-anatomical tooth would be helpful to get additional retention and stability. The monoplane occlusion has been used long time because it can eliminate horizontal forces and many other advantages. The lingualized occlusion was introduced to improve chewing efficiency and esthetics. But from a stability aspect, it seems controversy between monoplane occlusion and lingualized occlusion. This case report shows the results of the treat two flat residual ridge patients using functional impression; piezography, and made 2 other dentures with monoplane and lingualized occlusion that patient can select denture.

A Study on the Presence of Post-Miesianism and Its Future (Post-Miesianism의 실체와 미래에 대한 연구)

  • Lee, Sang-Jin
    • Journal of architectural history
    • /
    • v.10 no.4 s.28
    • /
    • pp.77-92
    • /
    • 2001
  • 현대의 건축시기는 다원성의 시기 또는 복합성의 시기라고 불리운다. 모더니즘과 포스트모더니즘의 시기를 거치며 다양한 형태적 실험의 과정을 겪었고 수많은 이데올로기와 이론들로 무장된 논쟁의 역사도 갖게 되었다. 이러한 현대건축의 다양성은 건축디자인이라는 전문직의 사회에 기여하는 역할을 반추(反芻)함과 동시에 다변하는 인간사고의 역동성을 반영하고 있다. 건축관련 책자나 저널 등에서 흔히 발견할 수 있는 Neo-Classicism, Deconstructivism, Minimalism, High-Tech, New Moderns 등등의 건축양식들은 스타일을 지칭하는 언어라기보다는 건축적 사고를 지칭하는 언어라고 할 수 있다. 결국 건축디자인이라는 작업은 인간을 둘러 싼 건조환경의 생성에서 출발하는 것이므로 건축적 사고방식은 그 시기의 사회현상과 밀접한 관계를 맺게 된다. 20세기 말부터 불어닥친 디지털 문화의 사회변혁은 전 세계를 하나의 채널로 엮게 되었고, 이러한 영향들은 지역과 민족, 그리고 종교적인 요소들까지도 혼합하여 국경을 초월한 미래의 새로운 이상들을 꿈꾸게 되었다. 19세기 산업혁명과 함께 급속히 벨라진 인류문명의 진보는 필수적으로 세계화를 동반하는 것이고, 세계화와 지역성사이의 괴리를 통해 나타나는 문화적 비판과 충돌은 아직도 진행상태인 것이다. 세계화라는 통염은 문명의 보편성을 기반으로 하며 전통문화의 파괴가 뒤따를 수밖에 없는데, 현재와 같이 IT혁명을 통해 급속도로 빨라진 세계문화의 교류는 한 국가가 뿌리를 내리고 있는 문화적 유산이라는 토양을 포기하여야 할 단계에 와 있다고 논평할 정도이다. 여기서 건축은 문화적 상징으로 작용하게 되는데, 그것이 심미적이든 관습적이든 또는, 경제적이든 건축가는 해답의 제시라는 임무에 직면하게 된다. 20세기에 진행된 모더니즘의 건축은 구조와 공간에 대한 고전건축의 숙원을 고덕건축이 이룬 것처럼 15세기 르네상스 시대로부터 진행된 형태와 공간, 기능, 그리고 아름다움과 기술(technology) 또는 경제성 등에 대한 건축적 의문과 탐구를 일단락지었다고 할 수 있다. 이러한 모더니즘의 한복판에 Mies van der Rohe라는 거장이 깊은 발자국을 남기며 한 시대를 이루었고 그가 남긴 시대정신의 이념과 가치를 Miesianism이라고 부른다. 실용성과 도덕성을 근본으로 하는 Miesianism은 대중에 호소하는 미적 표현주의를 부정하고 지역정서를 중시하는 문맥적 접근방식을 경시함으로써 보편화라는 현상을 불러일으킨 국제주의 양식의 한 부류로 비판을 받아왔다. 즉, Miesianism의 단순하고 강렬한 외형적 요소는 그것이 내포하는 기술적 합리성이나 공간적 완결성을 무시한 채 전 세계에 영향을 미쳤고 동시에 지역적 저항을 받게 되었다. 시카고 및 전 세계의 Miesian들, 즉 Mies van der Rohe의 제자들이나 그로부터 영향을 받은 수많은 건축가들은 이러한 저항과 비판에 직면하게 되며 새로운 사고의 시대적 요구 앞에 고뇌하게 된다. 한국에서는 1978년 Mies van der Rohe의 제자인 김종성이 미국에서 서울로 돌아와 '서울건축컨설탄트'를 설립하며 본격적으로 Miesianism의 규범적 건축론을 설파하기 시작하였다. 이른바 시카고 국제주의학파의 건축전수라고 할 수 있는데 '서울건축컨설탄트'를 통하여 배출된 김종성의 제자들은 명쾌하고도 간결한 건축해법의 경험을 토대름대로의 정체성을 갖고자 노력하였으나 결국 다원적 가치를 요구하는 시대적 흐름 속에 혼란을 겪고 있는 것 또한 사실이다. 본 연구는 Miesianism의 기원을 밝히고 그것의 실수와 오류를 밝힘과 동시에 현대의 여러 가지 건축유형들과 비교하여 봄으로써 Post-Miesianism의 실체와 그 미래에 대하여 고찰하여 보고자 한다. 미스의 유산이라고 할 수 있는 Miesianism의 요체는 첫째, Schinkel로부터 이어받은 시대정신의 사명감, 둘째, Berlage가 전해준 전문가로서의 도덕성을 바탕으로 하여 이루어진 기술적 합리성의 실현, 그리고 마지막으로 그 당시의 추상예술에 대한 이해로써 받아들인 nee-Suprematism의 아방 가르데적인 자세라고 할 수 있다. 그러나 이것들을 전파하고 수용하는 과정에서 미스적인 단순하고 명쾌한 외관이 더욱 강한 인상을 남기게 되었고 또한 미스가 현대성의 본질이라고 믿는 기술의 전수는 모든 외관을 동일하게 만드는 International Style로서의 보편적 획일성을 초래하였다. Mies van der Rohe의 강력하고 규범적인 dogma는 그의 제자들에게는 강렬한 카리스마로 각인되었고, Mies가 원한 것이 아닐지라도 그들을 하나의 틀 속에 가두는 영향력을 행사하였다. 2세대이든 3세대이든 기술적 합리성과 추상적 단순미라는 믿음을 맹목적으로 추종할 때 그들은 Miesian으로 남아있게 되며, 거기서 벗어났을 때 non-Miesian, 또는 배신자로 취급하기까지 하였다. 이것은 미스의 제자들에게 강한 족쇄가 되어 형태적 또는 개념적 변화의 시도를 어렵게 하였고 시대적 요구에 부응하지 못한다는 평가에 이르게 되었다. 문화의 다양성과 역동성을 인정함과 동시에 Miesianism에 대한 새롭고 시대에 적합한 해석을 기대하게 되는데, 이러한 기대 속에서 우리는 Post-Miesianism이라는 새로운 유형을 엿볼 수 있게 된다. Post-Miesianism의 징후를 현대의 다양한 건축유형에서 발견할 수 있는데, High-Tech의 구축적이고 정밀한 건축 기술적 해법과 Minimalism의 반복성을 통한 추상미의 표현 등에서 뿐만이 아니라 Post-Modernism의 인간성의 추구나 문맥적 고려, 또는 해체주의의 형이상학적이고 아방가르데적인 실험주의 정신까지조차 Post-Miesianism이 공유할 수 있는 부분이 있다고 보여진다. 또한, 미스의 영향이 2세대, 3세대의 건축가들에게 미치면서 여러 방향으로 변질되어 가는 것을 우리는 발견할 수 있으며 그러한 시대성에 적응하는 시도들이야말로 새로운 미래를 향한 Post-Miesianism의 실체인 것이다. Mies가 말하였듯이 한 시대의 끝은 그 시대가 완전히 이해되었을 때이며, 모더니즘의 숙제는 아직 해결되지 않았으므로 Miesianism의 탐구는 Post-Miesianism이라는 새로운 주제로 계속될 것이다. 이를 통하여 21세기 디지털 문명의 시대 속에서 현대건축이 안을 수밖에 없는 보편성과 지역성의 충돌이라는 문제의 해결에 한 발걸음 다가갈 수 있기를 기대하여 본다.

  • PDF