• Title/Summary/Keyword: 실험 측정

Search Result 22,181, Processing Time 0.051 seconds

A study of $Smartpeg^{TM}'s$ lifetime according to sterilization for implant stability (임플랜트 안정성을 위한 자기공명막대의 소독방법에 따른 수명에 관한 연구)

  • Won, Ho-Yeon;Cho, In-Ho;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.42-52
    • /
    • 2008
  • Purpose: Resonance Frequency Analysis(RFA) technique can be used as an effective method in measuring the implant stability and documenting the clinical results. This technique also determines how stable the implant is before performing a prosthetic practice. Having become one the guidelines of the implant therapy whose final objective is the immediate loading, the $Osstell^{TM}$ mentor is giving a lot of information to the clinicians recently. In this communication, experiments were performed to investigate how reliable the measured ISQ values by $Osstell^{TM}$ mentor are, and to see if those are also stable even after sterilization. As five objectives: 1) How stable measured ISQ values after fixation $Smartpeg^{TM}s$ for 400 times. 2) How stable measured ISQ values after 'attach-detach'$Smartpeg^{TM}'s$ for 400 times. 3) How stable measured ISQ values after clinical sterilization methods. 4) How stable measured ISQ values after repeatedly sterilization in autoclave for 10 times. 5) What is the critical temperature which is lost the magnetism of $Smartpeg^{TM}$. Materials and Methods: Clinical sterilization methods(Autoclave sterilization, Dentistar sterilization, Ultra violet sterilization, Vacuum dry unit sterilization, Boiling water sterilization, combined $H_{2}O_{2}$ and Alcohol sterilization).$Smartpeg^{TM}s$. D3 Block bone($3{\times}9{\times}2cm$). Osstem implant(${\emptyset}4.1$-10mm).$Osstell^{TM}$ mentor. Individual experiment was used 8 number of $Smartpeg^{TM}s$ and they had measured to ISQ values of before experiment and after experiment. Results: 1. The measured ISQ values did not change after fixation $Smartpeg^{TM}s$ for 400 times. 2. There was no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ for 400 times. 3. The measured ISQ values did not change after the usual clinical sterilization methods. 4. The measured ISQ values did not change after sterilization in autoclave for 10 times. 5. It was impossible to exactly measure the critical temperature which is lost the magnetism of $Smartpeg^{TM}s$. But, the results was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10 minute. Conclusion: The measured ISQ values showed insignificant differences in case of no changes in the magnetism of the $Smartpeg^{TM}s$. It seems that the $Smartpeg^{TM}s$ can be used repeatedly in every measurement if the original magnetisms of the $Smartpeg^{TM}s$ can be recognized. There seems to be no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ only if the screw pitches were unimpaired. The clinical sterilization methods seems acceptable because the result was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10minute.

Experimental Study on the Effect of Specimen Size on Electrical Resistivity Measurement (전기비저항 측정에서 실험체 크기의 영향에 대한 실험적 연구)

  • Lim, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.164-169
    • /
    • 2018
  • In this study, the effect of the size of the specimen on the apparent resistivity was investigated at the laboratory level for electrical resistivity. The specimens were measured for apparent resistivity by fabricating specimens with different sides and heights. Experimental results show that the apparent resistivity increases as the side and height of the specimen become smaller. Also, it was confirmed that the influence of the size of the specimen on the electrical resistivity measurement was not linear.

Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method (오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현)

  • Kang Seong-Chul;Jeon Gye-Rock;Jeong Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.689-692
    • /
    • 2006
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed to reduce errors and weaknesses of the existing invasive blood pressure measurement methods. The system is composed of pressure control, signal measurement and blood pressure signal processing units. To verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Management System for Experimental Data In Remote Measurement Device Using TCP/IP Socket (TCP/IP 소켓을 이용한 원격 측정 장치의 실험 데이터 통합 관리 시스템 개발)

  • Kim, Seon-Yeong;Cho, Hwan-Gue
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06b
    • /
    • pp.397-400
    • /
    • 2010
  • 최근의 과학 실험은 그 규모나 내용에 있어서 점차 대형화되는 동시에 복잡해지고 있다. 이로 인하여 다양한 측정 장비로부터 도출된 실험 결과를 효율적으로 분석, 관리, 종합하는 도구의 필요성이 커지고 있다. 본 논문에서는 원격 측정 장치로부터 서로 다른 포맷의 실험 데이터를 자동 수집한 후 이중 정제한 데이터들만 추출하여 웹에서 시각화하는 실험 데이터 통합 관리 시스템을 제안한다. 먼저 원격 측정 장치의 데이터를 자동으로 수집하기 위해 폴링 서버를 설계하여 장치마다 폴링 에이전트를 도입하였다. 이를 통해 관리자가 각 측정 장치에 직접 접근하지 않고도 데이터를 수집할 수 있다. 폴링으로 확보한 데이터는 파싱을 통해 정제하고, 이들 데이터로 데이터베이스를 구축한다. 정제한 데이터는 시각화하여 사용자가 웹에서 쉽게 파악할 수 있다. 데이터 폴링은 TCP/IP Socket을 통해 수행하므로 보편적으로 사용하는 FTP 방식에 비해 데이터 확보 시 신뢰성을 높일 수 있으며, 폴링 여부 판단 시에는 동기식, 실제 폴링 시에는 비동기식 통신 방법을 사용하여 폴링의 효율을 높였다. 본 시스템을 활용하여 사용자의 임의적인 데이터 접근을 최소화하였고 데이터의 전송, 저장, 관리를 자동화함으로써 편의성을 높였다. 본 시스템을 활용하여 원격 실험 장치로부터 데이터를 확보할 때의 정확성과 폴링 및 파싱 속도를 실험을 통해 측정하였고, 그 결과 폴링 시 100%의 정확도와 정상 포맷의 데이터에 대해서 100%의 파싱 결과를 보임으로써 본 시스템이 원격 장치의 실험 데이터를 통합 관리할 때 적합함을 알 수 있었다. 추후 데이터의 속성에 따라 클러스터링 할 예정이며 클러스터링에 따른 시각화 서비스를 제공할 계획이다.

  • PDF

Test Equipment and Test Portfolio for Education of Strain and Vibration Measurements (변형률 및 진동 측정 교육을 위한 실험 장치와 실험 포트폴리오)

  • Yang, Jimin;Lee, Dooyoul
    • Journal of Practical Engineering Education
    • /
    • v.13 no.3
    • /
    • pp.497-505
    • /
    • 2021
  • Test equipment for strain and vibration measurement was designed for educational purposes. Widely available and affordable materials were put into making this device. Three strain gauges placed on an iron ruler made cantilevered beam were used to measure values according to external load. An electromagnet triggered excitation and a function generator created vibration of the beam. We present three different tests conducted with this equipment regarding production of scales, measurement of resonant frequency, and calculation of the difference between excitation frequency and measured frequency. Overall, this paper presents a piece of simple yet inexpensive test equipment and its corresponding portfolio with expectations of being applied to the educational field for efficient measurement of load and vibration.

전신 정위 프레임을 이용한 환자의 움직임 및 외부자세 setup 오차 분석

  • 정진범;정원균;서태석;최경식;지영훈;이형구;최보영
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.59-59
    • /
    • 2003
  • 목적 : 환자의 호흡에 의한 움직임 및 부정확한 환자 자세 setup 때문에 3 차원 전신 정위 방사선치료,3 차원 입체조형 방사선치료 IMRT와 같은 방사선 치료기술에서 병소에 대한 정확한 표적 위치측정은 매우 어려운 실정이다. 그러므로 본 연구는 방사선 치료시 환자의 움직임을 최대한 고정시켜 줄 수 있으며 환자 자세에 대한 setup 오차를 감소시키고 환자 전신에 산재한 병소의 위치를 좌표화할 수 있는 전신 정위 프레임 제작과 제작한 프레임에 대한 고정효과 및 재현성을 나타내는 환자 자세의 setup 오차를 평가하는데 있다. 재료 및 방법 : 자체 제작한 전신 정위 프레임 구조는 CT 영상 촬영 가능성에 중점을 두고 병소 표적의 좌표실현 및 환자체형에 따른 다양성 그리고 프레임에 대한 견고성 및 안정성 확인에 초점화하여 제작하였다. 이렇게 제작된 전신 정위 프레임에 대한 방사선 투과율 측정 실험과 CCTV 카메라와 DVR(Digital Video Recorder)를 이용해 환자 자세 변화에 대한 영상을 획득하여 matlab으로 구현한 오차분석용 프로그램으로 환자 외부자세에 대한 오차 비교 평가하고 CT 촬영에 의한 가상표적 위치측정 실험을 수행하였다. 또 한 고정벨트 추가 사용으로 인한 환자의 고정효과 정도를 살펴보았다. 결과 : 제작된 전신 정위 프레임에 대한 방사선 투과율은 마그네트론 10, 21 MeV의 에너지에서 95, 96% 의 투과율이 측정되었고 30 $^{\circ}$. 60 。각도의 경사로 빔이 전달될 때는 90.3, 94.4% 가 측정되었다. CCTV 카메라를 이용하여 흉부 및 복부의 움직임을 촬영한 영상을 Matlab프로그램으로 구현한 오차분석 프로그램을 적용한 결과, 환자 자세에 대한 오차의 평균값은 흉부의 lateral 방향에서는 3.63$\pm$1.4 mm, AP 방향에서는 2.1$\pm$0.82 mm이었다. 그리고 복부의 later의 방향에서는 7.0$\pm$2.1 mm, AP 방향에서는 6.5$\pm$2.2 mm 이었다. 또한 표적 위치측정을 위해서 환자의 피부에 임의의 가상표적을 부착하고 CT 촬영한 영상결과, 프레임으로 가상표 적에 대한 위치를 정확히 파악할 수 있었다. 결론 : 제작된 프레임을 적용하여 방사선투과율 측정실험, 환자 외부자세에 대한 오차 측정실험, 가상표적 위치측정 실험 등을 수행하였다. 환자 외부자세에 대한 오차 측정실험 경우, 더 많은 Volunteer를 적용하여 보다 정확한 오차 측정실험이 수행되어야 할 것이며 정확한 표적 위치 측정실험을 위해서 내부 마커를 삽입한 환자를 적용한 임상실험이 수행되어야 할 것이다. 또한 위치결정에서 획득한 좌표값의 정확성을 알아보기 위해서 팬톰을 이용한 방사선조사 실험이 추후에 실행되어져야 할 것이다. 그리고 제작된 프레임에 Rotating X선 시스템과 내부 장기의 움직임을 계량화하고 PTV에서의 최적 여유폭을 설정함으로써 정위 방사선수술 및 3 차원 업체 방사선치료에 대한 병소 위치측정과 환자의 자세에 대한 setup 오차측정 결정에 도움이 될 수 있을 것이라고 사료된다.

  • PDF

원자로 용기 하부 냉각 실험에서의 용융물과 용기면의 간극 측정 기법 개발

  • 강경호;김종환;함영수;김상백
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.557-562
    • /
    • 1997
  • 노심용융물의 노내 자연 냉각 현상은 TMI-2 사고 이래로 실험과 해석 분야에서 많은 연구가 이루어지고 있으나, 아직까지는 이에 대한 명확한 규명이 이루어지지 않은 상태이다. 원자로 용기 냉각 Mechanism 중에서 노심용융물이 원자로 용기 하부 반구내로 재배치되어 하부 반구 내벽과 접촉할 때 용융물과 하부 반구 내벽 사이에 생길 수 있는 작은 간극으로 냉각수가 침투되어 노심용융물의 냉각이 이루어질 수 있다는 가정이 유력하게 제기되고 있다 본 논문에서는 노심용융물과 원자로 용기 하부 반구 사이의 간극을 통한 노심용융물의 냉각 특성을 규명하는 SONATA-IV실험 연구와 연계하여 이상 유동이 존재하는 고온 표면에서의 미세한 간극을 측정할 수 있는 방법의 검토 및 시편을 이용한 실험을 통하여 가장 적합한 간극측정기법을 도출하였다 간극 측정 기법으로는 중성자 래디오그라피, X 선 후방산란 단층기법 그리고 초음파 펄스 반사 탐상법을 검토하였으며, 시편 측정 실험결과 실시간 간극 측정방법으로는 초음파 펄스 반사 탐상법이 가장 적합한 것으로 나타났다.

  • PDF

An Experimental Phonetic Study of the Word Duration in Standard Korean - with reference to its contextual effects - (한국어의 낱말 지속시간에 관한 실험음성학적 연구 - contextual effect와 관련하여 -)

  • 성철재
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.191-194
    • /
    • 1995
  • 환경적 요인으로 인하여 측정간격이 지속시간이 변할 수 있는 지의 l여부를 알아보기 위해 실험을 행하였다. 실험에서의 측정간격은 어절단위이며 이러한 실험을 통해서 소위 구-길이 효과의 한 츠면도 파악해 볼 수 있다. 측정간격 양쪽의 어절에서 체계적인 음절증가를 유도한 뒤 나타날 수 있는 측정간격의 지속시간에서의 변화율을 측정하였다. 결과는 엄격한 의미에서 체계적으로 기술될 수 있을 만한 단음화효과는 나타나지 않았다. 어느 정도의 융통성을 둔다면 순행단음화 효과의 부분적인 출현은 인정할 만하다. 문장의 중간에 위치한 어절과 양쪽 환경 각각을 짝을 지워 상관관계를 따져본 결과 양의 상관이 더 많이 나타났다. 결과적으로 실험에서의 측정간격은 지속시간에 관한 한 문장 내에서 독립적인 활동을 하는 단위로 생각할 수 있다.

  • PDF

의학연구에서 반복측정 실험 계획법

  • 박선일
    • Journal of the korean veterinary medical association
    • /
    • v.38 no.10
    • /
    • pp.892-914
    • /
    • 2002
  • 의학연구에서는 여러 가지 이유로 반복측정 실험이 자주 수행된다. 저자가 대한수의학회지와 임상수의학회지에 발표된 최근 몇 년의 실험연구를 분석한 결과 상당수의 논문이 반복측정 실험계획을 활용하였지만 자료분석에서는 매우 잘못된 분석을 수행함으로써 결과의 신빙성과 객관성에 많은 문제점을 안고 있는 것으로 조사되었다. 아무리 훌륭한 실험을 수행하였다고 하더라도 실험계획에 적합하지 않는 자료분석은 논문으로서의 가치가 없음을 너무나 분명한 사실이다. 많은 국내외 저자들이 의학연구에서 자료분석의 오류가 끊임없이 지적하였음에도 불구하고 이에 대한 교육 부재와 필요성에 대한 인식부족은 여전하다. 본 원고에서는 의학연구에서 흔하게 접하는 두가지 예제를 들어 반복측정 실험계획의 기본원리와 분석법 및 결과의 해석에 초점을 맞추어 설명하고자 한다. 본 실험계획법에 대하여 관심이 있는 독자는 저자에게 연락하면 자세한 논의를 할 수 있다.

  • PDF

Acoustic Information as Determinant of Personality - Focused on Cases of Ring-Back-Tone (RBT) of Mobile Phone - (사용자의 퍼스날리티를 파악하기 위한 요소로서 청각 정보에 대한 연구 - 핸드폰의 Ring Back Tone (RBT) 서비스를 중심으로 -)

  • Kim, Bo-Min;Kwon, Moon-Young;Suk, Hyeon-Jeong;Jeong, Sang-Hoon
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2007.05a
    • /
    • pp.23-26
    • /
    • 2007
  • 본 연구에서는 Ring-Back-Tone(RBT)의 개성이 통화 상대자의 퍼스널리티를 측정하는데 영향을 끼치는가에 대하여 실험연구를 진행하였다. 음악과 통화상대자의 퍼스널리티를 측정하기 위해, 성격 5요인 모형에서 음악의 특성과 밀접한 관련을 가진 3가지 요인인 Openness(개방성), Extroversion(외향성), Neuroticism(신경성)에 중심으로 각 요인에 속하는 12가지 하위 특성(trait)를 측정 도구로 활용하였다. 예비실험에서는, 17가지의 음악의 퍼스널리터를 측정하였으며 이 중 3가지를 선정하여 본 실험의 RBT로 설정하였다(N=15). 본 실험에서는 동일한 통화 상대자의 퍼스널리티에 대하여 각각의 RBT 음악의 경우마다 측정한 결과를 비교 분석하였으며, 3가지 RBT와 RBT를 설정하지 않은 대조군에 대하여 각각 15명의 피실험자들이 참여하였다(N=60). 피실험자들은 통화 상대자의 퍼스널리티의 Openness와 Extroversion을 측정하는데 있어 무의식중에 인지된 RBT의 개성의 영향을 받는 것으로 나타났다(p<0.01). 또한 RBT개성과 측정된 통화 상대자의 퍼스날리티 간에 유사한 성향이 있음을 발견하였다(r=0.753).

  • PDF