• Title/Summary/Keyword: 실험 반복 시간

Search Result 894, Processing Time 0.024 seconds

Effect of Nb, V and Cr on the High Temperature Oxidation of Ti-(42, 44)% Al Alloys (Ti-(42, 44)%Al 합금의 고온내산화성에 미치는 Nb, V 및 Cr의 영향)

  • Lee, Yeong-Chan;Kim, Mi-Hyeon;Kim, Seong-Hun;Lee, Won-Uk;Baek, Jong-Hyeon;Lee, Dong-Bok
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.1025-1031
    • /
    • 1999
  • Alloys of TiAl with six different compositions. i. e., Ti-(42, 44)Al-2Nb-4V. Ti-(42, 44)Al-4Nb-2V and Ti -(42, 44)Al-4Nb-2Cr, were manufactured by arc-melting. and their oxidation behavior was studied. Both isothermal and cyclic oxidation tests were performed at 700, 800 and $900^{\circ}C$ in air for 50hr. The oxidation resistance increased in the order of Ti-(42, 44)Al-2Nb-4V, Ti-(42, 44)Al-4Nb-ZV and Ti-(42, 44)Al-4Nb-2Cr. It was found that V was a deleterious element, while Cr was a beneficial element in terms of oxidation resistance. During oxidation, a simultaneous interdiffusion was observed. All the constituent elements in the base alloys diffused outward. whereas oxygen from the atmosphere diffused inward, to form triple oxide layers composed of an outermost $\textrm{TiO}_2$ layer. upper ($\textrm{TiO}_2+\textrm{Al}_2\textrm{O}_3$) mixed layer, and lower $\textrm{TiO}_2$-rich layer.

  • PDF

Polymerase Chain Reaction for the Rapid Detection of Listeria monocytogenes in Foods Using HlyA Gene Primers (HlyA유전자 Primer를 이용한 PCR에 의한 식품으로부터 Listeria monocytogenes의 신속 검출 방법)

  • 최영춘;박부길;오덕환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.6
    • /
    • pp.1016-1024
    • /
    • 2000
  • The study was conducted to develop a rapid method for the detection of Listeria monocytogenes in foods via polymerase chain reaction (PCR) technique using hemolysin gene (hlyA) primers. Specificity and sensitivity of PCR, optimal conditions for PCR and application of hlyA gene primers for the detection of L. monocytogenes from milk and beef were investigeted. Each of the 20 L. monocytogenes strains gave a single 713 bp band, but other Listeria sup. and other bacteria did not show any bands. As few as 1 pg of L. monocytogenes DNA or 2.4$\times$10$^4$L. monocytogenes cells could be detected with hlyA gene primers. PCR product was most improved at 20~30 cycle in terms of removal of tailing and sensitivity. Also, the sensitivity was significantly improved by the further 10~15 cycle after 20 cycle PCR amplication. Milk (10 mL) and beef (10 g) samples were inoculated with L. monocytogenes at the concentrations ranging from 0 to 10$^{7}$ CFU/mL or g to determine the best sensitivity of PCR for the rapid detection of L. monocytogenes. PCR assay could detect 2 cells in milk with repeating PCR amplication and 2.6$\times$10$^2$cells in beef sample after 24 hr enrichment growth at 35$^{\circ}C$ in LEB.

  • PDF

Automatic Sagittal Plane Detection for the Identification of the Mandibular Canal (치아 신경관 식별을 위한 자동 시상면 검출법)

  • Pak, Hyunji;Kim, Dongjoon;Shin, Yeong-Gil
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.3
    • /
    • pp.31-37
    • /
    • 2020
  • Identification of the mandibular canal path in Computed Tomography (CT) scans is important in dental implantology. Typically, prior to the implant planning, dentists find a sagittal plane where the mandibular canal path is maximally observed, to manually identify the mandibular canal. However, this is time-consuming and requires extensive experience. In this paper, we propose a deep-learning-based framework to detect the desired sagittal plane automatically. This is accomplished by utilizing two main techniques: 1) a modified version of the iterative transformation network (ITN) method for obtaining initial planes, and 2) a fine searching method based on a convolutional neural network (CNN) classifier for detecting the desirable sagittal plane. This combination of techniques facilitates accurate plane detection, which is a limitation of the stand-alone ITN method. We have tested on a number of CT datasets to demonstrate that the proposed method can achieve more satisfactory results compared to the ITN method. This allows dentists to identify the mandibular canal path efficiently, providing a foundation for future research into more efficient, automatic mandibular canal detection methods.

Robust determination of control parameters in K chart with respect to data structures (데이터 구조에 강건한 K 관리도의 관리 모수 결정)

  • Park, Ingkeun;Lee, Sungim
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.6
    • /
    • pp.1353-1366
    • /
    • 2015
  • These days Shewhart control chart for evaluating stability of the process is widely used in various field. But it must follow strict assumption of distribution. In real-life problems, this assumption is often violated when many quality characteristics follow non-normal distribution. Moreover, it is more serious in multivariate quality characteristics. To overcome this problem, many researchers have studied the non-parametric control charts. Recently, SVDD (Support Vector Data Description) control chart based on RBF (Radial Basis Function) Kernel, which is called K-chart, determines description of data region on in-control process and is used in various field. But it is important to select kernel parameter or etc. in order to apply the K-chart and they must be predetermined. For this, many researchers use grid search for optimizing parameters. But it has some problems such as selecting search range, calculating cost and time, etc. In this paper, we research the efficiency of selecting parameter regions as data structure vary via simulation study and propose a new method for determining parameters so that it can be easily used and discuss a robust choice of parameters for various data structures. In addition, we apply it on the real example and evaluate its performance.

The Effect of Additives on the Properties of Zn Electrode in Zn/AgO Secondary Battery (Zn/AgO Secondary Battery용 아연 양극의 성능에 미치는 첨가제의 영향)

  • Park, Kyung-Wha;Kim, Chang-Hwan;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • We investigated the effect of both 4 types additives and $0.5wt\%\;Pb_3O_4$ which have been reported to show an improvement on the performance of Zinc anode. And Experimental methods such as corrosion potential measurement, potentiodynamic polorization test and charging-discharging cycle life test were carried out in $40 wt\%$ KOH with $Pb_3O_4(0.5, \;10\;&\;2.0wt\%)$ and 4 types additives $(0.4wt\%\;of\;Ca(OH)_2$, 0.025M of Citrate, Tartrate and Gluconate). Corrosion potential was shifted to high direction and also changed to high and low direction repeatedly with increasing of $Pb_3O_4$ quantity. However by adding $0.5wt\%\;Pb_3O_4$, corrosion potential shifted to low direction and showed stable condition. Furthermore it was well known that corrosion resistance was predominantly increased compared to no addition and improved charging-discharging property with adding additives. By SEM analysis, it was concluded that the morphology of surface in case of only $0.5wt\%\;Pb_3O_4$ addition was nearly the same as that of Tartrate additive and in the other additives such as $Ca(OH)_2$, Citrate, Tartrate and Gluconate, their morphologies showed dendrite growth. Eventually it was thought that the additive of Tartrate indicated comparatively good corrosion resistance effect as well as charging-discharging property improvement among those four types additives.

The Effects of Microcurrent Stimulation on Erector Spinae Fatigue Index (미세전류 자극이 척주세움근의 피로지수에 미치는 영향)

  • Kang, Da-Haeng
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.545-551
    • /
    • 2013
  • This study aimed to compare the effects of microcurrent stimulation and rest on the fatigue index by applying both to subjects who had accumulated fatigue after performing short-duration physical activity. The experiment was performed at S University from December 2012 to February 2013, on 22 healthy men in their 20s, who were right-handed, and without peripheral or musculoskeletal diseases. All subjects lifted a 10-kg box lift and lower 100 times in 15 minutes. Immediately after that, muscle fatigue index (Median Frequency: MF) and blood fatigue index (Creatine Kinase Lactate: CK, Lactate Dehydrogenase: LDH) were measured by using surface electromyography. The subjects were divided into two groups, and microcurrent stimulation and rest were mediated to the experimental and control groups, respectively, for 20 minutes. After intervention, muscle fatigue index and blood fatigue index were measured and the changes in the accumulated fatigue index were compared. Both groups manifested significantly decreased cumulative fatigue after applying the mediation compared to the pre-intervention level (p < .05), the only exception being the fatigue index of the left erector spinae in the rest group. Compared to the rest group, the microcurrent stimulation group showed a significant decrease in muscle fatigue index (p < .05) but no significant differences were found in the blood fatigue index. Given the results of this study, microcurrent stimulation is considered to be helpful in muscle fatigue recovery for workers who have to perform repetitive movements lifting weights, and additional studies on the correlations of the fatigue recovery with respect to the long-term follow-up of fatigue index and mediation time are necessary.

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

Effects of Hot Isostatic Pressing on Bond Strength and Elevated Temperature Characteristics of Plasma sprayed TBC (HIP처리가 플라즈마 용사된 열차폐 코팅층의 접착강도와 고온특성에 미치는 영향)

  • Park, Young-Kyu;Kim, Sung-Hwi;Kim, Doo-Soo;Lee, Young-Chan;Choi, Cheol;Jung, Jin-Sung;Kim, Gil-Moo;Kim, Jae-Chul
    • Korean Journal of Materials Research
    • /
    • v.10 no.4
    • /
    • pp.312-316
    • /
    • 2000
  • A study has been made to investigate the effects of hot isostatic pressing(HIP ping) on bond strength and elevated temperature characteristics of thermal barrier coating(TBC). The specimens were prepared by HIPping of TBC which is composed of the ceramic top coat(8wt%$Y_2$$O_3$-$ZrO_2$) and the metallic bond coat on the matrix of IN738LC superalloy. The results showed that the porosity and microcracks in the ceramic top coat of TBC were significantly decreased by HIP. As a result, the bond strength of the HIPped coating was increased above 48% compared to that of as-coated specimen and microstructure was homogenized. It was found that the thermal cycle resistance of HIPped coating was inferior to that of as-coated specimen. It was considered that this result was mainly caused by the reduction of internal defects in the top coat layer which could play a role in relaxing the thermal stress due to a large difference in thermal expansion between TBC and matrix.

  • PDF

Range Stabbing Technique for Continuous Queries on RFID Streaming Data) (RFID 스트리밍 데이타의 연속질의를 위한 영역 스태빙 기법)

  • Park, Jae-Kwan;Hong, Bong-Hee;Lee, Ki-Han
    • Journal of KIISE:Databases
    • /
    • v.36 no.2
    • /
    • pp.112-122
    • /
    • 2009
  • The EPCglobal leading the development in RFID standards proposed Event Cycle Specification (ECSpec) and Event Cycle Reports (ECReports) for the standard about RFID middleware interface. ECSpec is a specification for filtering and collecting RFID tag data and is treated as a Continuous Query (CQ) processed during fixed time intervals repeatedly. ECReport is a specification for describing the results after ECSpec is processed. Thus, it is efficient to apply Query Indexing technique designed for the continuous query processing. This query index processes ECSpecs as data and tag events as queries for efficiency. In logistics environment, the similar or same products are transferred together. Also, when RFID tags attached to the products are acquired, the acquisition events occur massively for the short period. For these properties, it is inefficient to process the massive events one by one. In this paper, we propose a technique reducing similar search process by considering tag events which are collected by the report period in ECSpec, as a range query. For this group processing, we suggest a queuing method for collecting tag events efficiently and a structure for generating range queries in the queues. The experiments show that performance is enhanced by the proposed methods.

Testing for validity of isometric muscle endurance test as an abdominal muscular endurance evaluation methods (복근 지구력 평가 도구로서 등척성 수축 후 버티기 방법의 타당성 비교 검증)

  • Park, Soon-Tae;Hur, Sung-Hoon;Lee, Jang-Kyu;Lee, Jong-Sam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.815-827
    • /
    • 2014
  • The current study was undertaken to verify appropriateness of muscle endurance test at three different angles ($30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$) of isometric contraction position, and to sought valid and reliable testing method that provide an alternative to sit-ups. Total 92 young and healthy subjects (68 males and 24 females) were recruited, and the following results were obtained. 1. A low correlations in males, but a high correlations in females was found when the comparisons were made between aerobic and muscle endurance capability. 2. Measuring tolerance time, by using isometric contraction was showed a significant correlation with the repetition numbers of sit-ups. 3. The highest correlation was found at 40 inclined degrees of plane, and the lowest correlation was drawn from 50 inclined degrees of plane. Based on these results, it was concluded that measuring tolerance time during maintaining an isometric contraction at 40 inclined degrees of plane is a valid and effective tool for measuring abdominal muscle endurance, and it can be used as an alternative way of sit-up, which potentially risky for inducing many back-associated injuries. Further studies need to be undertaken to determine for optimal angles, that can safely be applied for people of various age groups and physical conditions.