• Title/Summary/Keyword: 실험상관식

Search Result 881, Processing Time 0.028 seconds

Empirical Correlations of Frost Thickness and Frost Surface Temperature on Heat Exchanger Fin (열교환기 휜에서의 서리층 두께와 서리층 표면온도의 실험 상관식)

  • Kim, Kyoung-Min;Kim, Jung-Soo;Kim, Jang-Hyun;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.798-803
    • /
    • 2009
  • In this study, dimensionless correlations of frost properties (i.e. the thickness and surface temperature of frost) on heat exchanger fin with nonuniform temperature distribution are proposed from frosting experiments. We analyzed the local fin temperature distribution, frost thickness and frost surface temperature on a 2D fin; in the airflow direction and the direction perpendicular to airflow. As a result, the frost growth on the fin had a close relation with fin heat conduction. The dimensionless correlations for the average frost properties were expressed as a function of dimensionless temperature, humidity ratio, Reynolds number, and Fourier number. These correlations agreed well with experimental data with the error less than 14%.

  • PDF

Measurement of The Thermal Contact Conductance in Nuclear Fuel Element (핵 연료 요소내의 접촉 열전도도 측정)

  • Sung-Deok Hong;;Goon-Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.75-81
    • /
    • 1990
  • Experiments to predict the thermal contact conductance between the fuel pellet and cladding have been performed, which is important to determine the temperature distibution within the fuel rod. UO$_2$and Zircaloy-2 are used in these experiments. The measuring apparatus is composed of a presser which controls the contact pressure, a thermometer with 5.5 sheathed thermocouples, a vacuum pump, pellet and cladding rods, and two heating devices, etc. The thermal contact conductances were measured with varying the contact pressure and surface roughnesses of UO$_2$and Zircaloy-2 bars. The results show that an increase in the contact pressure and a decrease of surface roughness resulted in increase of the thermal contact conductance. Finally, a fitting correlation has been established and compared with widely-used correlations.

  • PDF

Effect of Aspect Ratio of Flat Tube on R410A Evaporation Heat Transfer and Pressure Drop (납작관의 종횡비가 R-410A 증발열전달 및 압력손실에 미치는 영향)

  • Kim, Nae Hyun;Lee, Eul Jong;Byun, Ho Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.395-404
    • /
    • 2013
  • In this study, R-410A evaporation heat transfer tests were conducted in flattened tubes made from 5-mm round tubes. The test range covered a saturation temperature of $15^{\circ}C$, heat flux of $5{\sim}15kW/m^2K$, and mass flux of $200-400kg/m^2s$. The results showed that both the condensation heat transfer coefficient and the pressure drop increased as the aspect ratio increased, with a pronounced increase for an aspect ratio of 4. A comparison of the flattened tube data with existing correlations revealed that the heat transfer coefficients were reasonably predicted by the Shah correlation, and the pressure drops were reasonably predicted by the Jung and Radermacher correlation.

Air-Water Flooding in Multirod Channels : Effects of Spacer Grids and Blockages (다봉채널내의 공기-물 플러딩 : 스페이서 그릿 및 블럭키지의 영향)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.381-393
    • /
    • 1993
  • This paper presents the experimental results on flooding of countercurrent flow in vertical multirod channels, which consists of falling water film and upward air flow. In particular, the effects of spacer grids, with and without mixing vane, and of blockage in the multirod bundle on the behaviour of flooding were investigated. The 5$\times$5 zircaloy tube bundle was used for the test section. The comparison of previous analytical models and empirical correlations with present data on flooding showed that the existing models and correlations predict much higher flooding curves. The spacer grid causes the lower flooding air flow rate to compare with the bare rod bundle. However, the mixing spacer grids need a higher flooding air flow rate for a constant liquid flow rate than the spacer grids without mixing vanes. The bundle containing blockages has the highest flooding air flow rate among the bundles with spacer grids and blockages. Empirical flooding correlations for the three types of test section have been made.

  • PDF

Effects of Double-diffusive Convection on the Mass Transport of Copper Ions in a Horizontal Porous Layer (수평 다공성유체층에서 이온의 물질전달에 대한 이중확산대류 효과)

  • Yoon Do-Young;Kim Min Chan;Choi Chang Kyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.98-105
    • /
    • 1999
  • In the present study, buoyant force and its stabilizing effects in an electrostatic field were examined systematically in order to reduce the effect of natural convection with thermal stratification in a horizontal fluid-saturated porous layer. The correlation of ionic mass transport induced by double-diffusive convection in a horizontal porous layer has been derived theoretically. And the theoretical model was examined by electrochemical experiments. The theoretical correlation for mass transport which is satisfying Forchheimer's flow equation and based on the micro-turbulence model is derived as a function of soltual Darcy-Rayleigh number, thermal Darcy-Rayleigh number and Lewis number. In the experiment, the mass transport of copper ions in $CuSO_4-H_2SO_4$ solution is measured by electrochemical technique. By assembling theoretical correlation and experimental results, the mass transport correlation induced by double-diffusive convection is proposed as $$Sh=\frac{0.03054(Rs_D-LeRa_D)^{1/2}}{1-3.8788(Rs_D-LeRa_D)^{-1/10}}$$ The present correlation looks flirty reasonable with comparing experimental results, and very promising for the applications of its prototype into various systems involving heat transfer as well as mass transfer, in order to control the effects of natural convection effectively.

Active Vibration Control of a Simply Supported Plate with Piezoelectric Sensors and Actuators-II. Experiment (압전센서와 액츄에이터를 이용한 단순지지 평판의 능동 진동제어-II. 실험)

  • 노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.1E
    • /
    • pp.30-41
    • /
    • 1992
  • 압전 센서와 액츄에이터를 이용한 단순지지 평판의 능동 진동제어에 관한 실험적 고찰을 하였 다. 외력과 압전 제어력에 대한 평판의 진동 진폭반응을 고찰하여 구한 이론식의 타당성을 실험적으로 검증하였으며, 사용된 진동원으로는 집중 진동 여기기와 압전 구동기를 채택하였다. 실머치와 이론치 상 호간에는 양호한 상관관계를 보였으며, 비교에서 나타나는 정략적인 오차의 원인을 분석하였다. 본 연구 에서는 고찰된 방법은 임의의 외력조건과 제어 알고리즘에 대해서 적용이 가능하다.

  • PDF

Factors Affecting HETP in Capillary Gas Chromatography (모세관 기체 크로마토그래미에서 HETP에 영향을 미치는 인자)

  • 노경호;나영진;정용안
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.88-92
    • /
    • 2002
  • The election profiles with different flow rates of motile phase were experimentally measured to investigate the effects on HETP in capillary gas chromatography. Based on the correlation coefficient ($r^2$), the first and second moments as well as HETP were determined from the elution cuties, and the parameters used in empirical equations were estimated. The empirical equations were expressed in terms of mobile phase velocity, and the theoretical Golay equation was considered. The samples were d-limonene and perillyl alcohol, potential anticancer agent mainly was contained in the peel of orange. From the experimental results, HETP of the samples were increased with mobile phase velocities. The correlation coefficient of d-limonene was in the range between 0.8265 and 0.8465, while that of perillyl alcohol was between 0.9353 and 0.9374. The total HETP was composed of $H_{g}$, $H_{l}$ and Hc, and Hg had the greatest effect on HETP, but HI showed a negligible effect. In terms of HETP, the optimum velocity of mobile phase was present.

Empirical Equation for Resolution if Ibuprofen Enantiomers by Chiral High-Performance Liquid Chromatography (키랄 고성능 액체 크로마토그래피를 이용하 이부프로펜의 분리도에 관한 실험식)

  • 여미순;노경호
    • KSBB Journal
    • /
    • v.18 no.4
    • /
    • pp.261-265
    • /
    • 2003
  • Ibuprofen was analyzed by chiral high performance liquid chromatography. Retention behaviours of the standard mixtures of ibuprofen were investigated to obtain their acceptable resolution. A chromatographic column (3.9 ${\times}$ 300 mm) was packed by Kromasil CHI-TBB packings (10 $\mu\textrm{m}$) and n-hexane was used as a mobile phase with 0.1% acetic acid and tert-butyl methyl ether. Isocratic elution of ibuprofen at 1.0 $m\ell$/min was performed by changing the mobile phase compositions. The experimental variables affecting the resolution were the compositions of mobile phase and chemical buffer (n-hexane and tert-butyl methyl ether). The resolution between the enantiomers were correlated into the several types of empirical equations including linear form, and their agreements between experimental data and calculated values were examined by the regression coefficient.

Experimental study on non-linear throughflow characteristics of rockfill gabion weir (돌망태 보 통과류의 비선형적 흐름 특성에 관한 실험적연구)

  • Han, Ilyeong;Lee, Jaejoung;Kim, Gyoo bum
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.861-870
    • /
    • 2020
  • As the flow velocity and Reynolds number increase in rockfill porous media, the flow deviates from Darcy conditions. In this study, the permeability tests of rock column specimen and laboratory gabion weir model were carried out to investigate a head loss behaviour of flow through rockfill deposition in small river artificial recharge. Through column test, the nonlinear relationships between flow velocity and hydraulic gradient and coefficients were determined and the correlation formula of hydraulic mean radius and coefficients was proposed. The flow velocities and discharges in voids estimated by proposed equations were well matched with the measured values of laboratory gabion weir model.

원자로 입구노즐에서의 원자로 냉각재 펌프에 의한 맥동압력 준위 예측

  • 정종식;양재영
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.205-209
    • /
    • 1996
  • 원자로 입구노즐에서 원자로 냉각재 펌프에 의한 맥동압력 준위를 원자로 하향통로와 저온 관을 상관시켜 예측하는 방법에 관하여 분석하였다. 원자로 하향통로에서의 맥동압력은 원자로 내부구조물의 건전성 평가에 쓰이는 중요한 인자로 이 값을 정확히 구하기 위해서는 경계조건인 입구노즐에서의 맥동압력을 정확히 예측해야 한다. 이를 위해 원자로 하향통로와 저온관을 상관시켜 원자로 입구노즐에서의 펌프에 의한 맥동압력 준위를 계산하였으며 Palo Verde Unit 1의 실험치와 비교 분석하였다. 분석 결과, 제시된 맥동압력 준위 예측모델은 500℉의 경우 비교적 잘 일치하였으나, 565℉의 경우 상당한 차이가 있었으므로 추가적인 검토 및 수정 작업이 요구된다.

  • PDF