• Title/Summary/Keyword: 실증설비

Search Result 339, Processing Time 0.036 seconds

교환기 부품 산업의 동향

  • Korean Associaton of Information & Telecommunication
    • 정보화사회
    • /
    • s.105
    • /
    • pp.24-35
    • /
    • 1996
  • 이 자료는 정보통신산업에서 중요한 위치를 차지하고 있는 교환기와 관련된 부품산업을 중심으로 국내 업계의 현황과 문제점을 실증적으로 파악하여 관련분야 기초자료를 제공하고자 한국정보통신진흥협회가 전자통신연구소로부터 수탁받아 실시한 "전기통신설비 및 운용관련 산업 실태 조사 분석"의 내용가운데 교환기 관련 부분중 부품시장에 관한 부문을 발췌한다.

  • PDF

A Study on the Demonstration of Yellow Plume Elimination System from Combined Cycle Power Plant Using Liquid Injection System (액상 직분사 시스템을 이용한 복합화력 황연제거 실증 연구)

  • Lee, Seung-Jae;Kim, Younghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.317-324
    • /
    • 2020
  • Combined cycle power plants (CCPP) that use natural gas as fuel are easier to start and stop, and have lower pollutant emissions, so their share of domestic power generation facilities is steadily increasing. However, CCPP have a high concentration of nitrogen dioxide (NO2) emission in the initial start-up and low-load operation region, which causes yellow plume and civil complaints. As a control technology, the yellow plume reduction system was developed and operated from the mid-2000s. However, this technology was unable to control the phenomenon due to insufficient preheating of the vaporization system for 10 to 20 minutes of the initial start-up. In this study, CFD analysis and demonstration tests were performed to derive a control technology by injecting a reducing agent directly into the gas turbine exhaust duct. CFD analysis was performed by classifying into 5 cases according to the exhaust gas condition. The RMS values of all cases were less than 15%, showing a good mixing. Based on this, the installation and testing of the demonstration facilities facilitated complete control of the yellow plume phenomenon in the initial start-up.

Characterization of Carbon Black and Oil from Positive Process of movable disc type for Waste Tires Pyrolysis (디스크 이동식 폐타이어 열분해 실증 설비로부터 생성된 Carbon Black, Oil의 특성 분석)

  • Ha, Hyun-Jung;Kim, Seong-Yeon;Kim, Ki-Kyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.483-486
    • /
    • 2008
  • 본 연구에서는 디스크 이동식 열분해 실증 설비를 이용하여 폐타이어 열분해 반응을 수행하였고, 생성된 열분해 생성물들의 특성을 분석하였다. 폐타이어 열분해 반응은 약 $550^{\circ}C$에서 90분간 진행되었고, 반응 결과 Recovered Oil, Carbon Black, Non Condensing Gas(NC Gas)가 생성되었다. 폐타이어 열분해 생성물의 수율은 Recovered Oil $40{\sim}50%$, Carbon Black 30$\sim$35%, NC Gas 10$\sim$15%, Steel 10$\sim$15%로 나타났다. 폐타이어 열분해 반응 후 생성된 Recovered Oil은 비점 및 특성 분석 결과 상업용 중유와 비슷한 성질을 나타냈고, 폐타이어 열분해 반응의 또 다른 생성물인 Carbon Black은 특성 분석 결과 고정 탄소 비율이 낮은 반면 회분과 휘발분의 비율이 높아 상업용으로 사용하기 위해서는 적절한 정제 과정이 필요함을 알 수 있었다.열분해 과정 중에 생성된NC Gas는 GC/MS를 이용하여 성분 분석을 수행한 결과, $CO_2$, $CH_4$를 비롯하여 주로 탄화수소류로 이루어졌으며, 대부분이 연료 가스로 구성되어 있어 열분해 반응의 열원으로서 사용이 가능하였다.

  • PDF

Verification Experiment and Calculation of Heating Load for a Test Space (시험공간에 대한 난방부하 실증실험 및 계산)

  • 현석균;홍희기;유호선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.153-160
    • /
    • 2002
  • As a way to assess the reliability of programs for building energy analysis, verification experiment and calculation of heating load are simultaneously conducted for a well-defined test space. Experimental conditions are carefully set to minimize uncertainties associated with radiation heating, air change, infiltration, and room-to-room interaction. Dyna- mic load calculations using TRNSYS, which are performed for two different computation domains, rely on the energy rate control that represents inherent load characteristics of a space. The predicted instantaneous heating load favorably simulates the overall behavior the measured one, though the latter fluctuates much more rapidly than the former Comparison of the accumulative load between the experiment and calculations shows a close agreement within an engineering tolerance, regardless of the computation model. It is deduced from such findings that the present experimental results along with weather information can serve as a set of reference data for validating load calculation softwares from the users'standpoint. In order to enhance the completeness of this work, a complementary study on the cooling load for the same test space is highly recommended.

Experimental Investigation for the Characteristics of Energy-Usage of Heating Systems in Apartment Complex Part I: Experiment System Implementation (난방방식별 에너지사용 특성 실증 분석 I: 실증 시스템 구축)

  • Im, Yong-Hoon;Choi, Kyu-Sung;Kim, Hyouck-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.480-487
    • /
    • 2007
  • The experimental implementation for different heating systems, district heating and separate heating and power, is discussed in the analysis of the characteristics of energy-usage in apartment complex. Total 20 families are chosen for the experiment, 10 for the district heating and the others for separate heating and power. Among the 10 families, the operating temperature was forced to be controled within certain range of temperatures for 5 ones, and it was left as usual for the other ones. The configuration and general features of each facilities and data acquisition systems are mentioned in brief and the technical specifications for it are also described. The analysis for the experiment results of this investigation is going to be carried out and published in a subsequent paper.

  • PDF

Demonstration study on Heating and Hot water According to Control Condition of Solar System (태양열 시스템의 제어조건에 따른 난방 및 급탕 실증연구)

  • Joo, Hong-Jin;Kwak, Hee-Youl;Kim, Jeong-Bae;Kim, Jong-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.832-837
    • /
    • 2006
  • This study describes thermal performance of heating and cooling demonstration system using ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about $331m^2$ was heated and cooled using that system. The demonstration system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, and subsidiary tank. From January to March in 2006, demonstration test were performed with 4 control mode to find the optimum control condition for solar thermal system. After experiments and analysis, this study found that solar thermal system of control mode IV was corresponded to 78% for the hot water supply and 49% for space heating.

  • PDF

Verification Experiment and Calculation of Cooling Load for a Test Space (시험공간에 대한 냉방부하 실증실험 및 계산)

  • 유호선;현석균;김용식;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.

석탄가스화 합성가스 제조공정 및 발전시스템 기술개발

  • Yun, Yong-Seung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.436-445
    • /
    • 2005
  • 석탄가스화는 화석연료인 석탄을 기존의 공해물질 발생을 90% 이상 줄이면서 고효율로 활용할 수 있는 방법이다. 3톤/일급 pilot급 석탄가스화 설비에서 생산된 CO와 수소가 주성분인 합성가스를 소형 LPG 엔진과 중형 천연가스 엔진에 연계시켜 발전시스템을 구성하였으며 전기생산까지 구현하였다. 합성가스의 고온 집진과 탈황을 자체기술로 구현하여 합성가스내 $H_2S$와 COS 성분들을 1 ppm 이하 정제와 99% 이상의 고온집진 효율을 확인하였다. 선진국들의 설비 규모에 비해서는 극히 열세인 국내 현황이지만, 고온고압의 석탄가스화로부터 탈황과 집진, 전기 생산까지 전 과정을 pilot 설비규모에서 실증하는 성과를 얻었으며 향후 전체 시스템의 최적화와 연속운전 기술의 개발로 이어진다면 중소형 석탄가스화 부분에서는 선진국과 차별화된 틈새시장 실용화 기술의 확보가 가능할 것이다.

  • PDF

Development and Actual Application of Governor Program to Nuclear Steam Turbine (원자력 증기터빈 조속기 프로그램 개발 및 실증 적용)

  • Choi, In-Kyu;Kim, Jong-An;Park, Doo-Yong;Woo, Joo-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • This paper describes the up-grade of the turbine governor for steam turbine due to its poor operation from long time use. The analog type governor of the unit 1 in Kori nuclear power plant in Korea was removed and the new digital type turbine governor was developed and installed. The procedure for the actual application, site adaptability test using dynamic simulator and the result of actual operation are described here. And the program for nuclear steam turbine is suggested here.

Evaluating the Applicability of diagnosis methods for aging at overhead systems (가공배전설비 열화진단기법 현장 적용성 평가)

  • Choi, Sun-Kyu;Lee, Jae-Bong;Lee, Byung-Sung;Park, Chul-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2058-2059
    • /
    • 2008
  • 한전 배전계통에서 적용되고 있는 가공설비 열화진단 장비의 특성 및 진단사례를 고찰하고, 측정 결과의 신뢰도 향상 방안을 제시하였다. 본 논문에서 제시한 열화설비 진단기법 및 신뢰도 향상 방안은 연구개발 과제로 채택되어 진행예정이며, 향후 실험실 모의시험 및 실증 시험을 통해 제시된 이론을 검증하고 체계화 하고자 한다.

  • PDF