• Title/Summary/Keyword: 실내 광원

Search Result 94, Processing Time 0.02 seconds

Prognostic Value of Blood Lactate for Mortality of Acutely Poisoned Patients in Emergency Department (응급실내 급성 중독 환자들의 예후 예측에 대한 혈액 젖산 수치의 유용성)

  • Kim, Hye Ran;Kang, Mun Ju;Kim, Yong Hwan;Lee, Jun Ho;Cho, Kwang Won;Hwang, Seong Youn;Lee, Dong Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.14 no.1
    • /
    • pp.16-25
    • /
    • 2016
  • Purpose: Patients suffering from acute poisoning by different substances often visit the emergency department (ED) and receive various prognoses according to the toxic material and patients' condition. Hyperlactatemia, which is an increased blood lactate level that generally indicates tissue hypoperfusion, is commonly utilized as a prognostic marker in critically ill patients such as those with sepsis. This study was conducted to investigate the relationships between blood lactate and clinical prognosis in acute poisoned patients. Methods: This retrospective study was conducted from January 2013 to June 2014 at a single and regional-tertiary ED. We enrolled study patients who were examined for blood test with lactate among acute intoxicated patients. The toxic materials, patient demographics, laboratory data, and mortalities were also reviewed. Additionally, we analyzed variables including blood lactate to verify the correlation with patient mortality. Results: A total of 531 patients were enrolled, including 24 (4.5%) non-survivors. Patient age, Glasgow coma scale (GCS), serum creatinine (Cr), aspartate transaminase (AST), and serum lactate differed significantly between survivors and non-survivors in the binary logistic regression analysis. Among these variables, GCS, AST, and lactate differed significantly. The median serum lactate levels were 2.0 mmol/L among survivors and 6.9 mmol/L among non-survivors. The AUC with the ROC curve and odds ratio of the initial serum lactate were 0.881 and 3.06 (0.89-8.64), respectively. Conclusion: Serum lactate was correlated with fatalities of acute poisoning patients in the ED; therefore, it may be used as a clinical predictor to anticipate their prognoses.

  • PDF

Ubiquitous sensor network based plant factory LED lighting system development (유비쿼터스 센서 네트워크 기반의 식물공장 LED 조명 시스템 개발)

  • Yang, Heekwon;Shin, Minseock;Lee, Chankil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.845-848
    • /
    • 2013
  • Due to intense climate changes and extreme weather conditions a noticeable decrease has been observed in the growth of certain plants. The indoor plant factories would have certain benefits including increase in crop yield, reduction in distribution cost, and maintains the healthy freshness level of the agricultural product. Recently, an artificial light source with optimum wavelength is spot lighted to fulfill the need of light for the indoor plant factories. The energy efficient light emitting diodes (LED) provide the essential light energy for the proper growth of indoor cultivated plants. This work focuses to utilize ubiquitous sensors network(USN) in providing suitable environment for the proper growth of agricultural product inside the indoor plant factory. The proposed system makes use of sensors and actuators, communicating each other through WPAN, ZigBee network. The proposed system obscured the traditional indoor plant factories with easy installation and wireless connectivity of the sensors and actuators along with eliminating the web of wires reducing the initial installation and maintenance cost.

  • PDF

A Study on the Ubiquitous Wireless Tilt Sensors's Application for Measuring Vertical Deflection of Bridge (교량의 수직처짐 측정을 위한 유비쿼터스 무선경사센서 활용연구)

  • Jo, Byung Wan;Yoon, Kwang Won;Kim, Young Ji;Lee, Dong Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.116-124
    • /
    • 2011
  • In this study, a new method to estimate the bridge deflection is developed by using Wireless Tilt Sensor. Most of evaluations of structural integrity, it is very important to measure the geometric profile, which is a major factor representing the global behavior of civil structure, especially bridges. In the past, Because of the lack of appropriate methods to measure the deflection curve of bridges on site, the measurement of deflection had been done restrictly within just a few discrete points along the bridge. Also the measurement point could be limited to locations installed with displacement transducers. So, in this study, the deflection of the structure was measured by wireless tilt sensor instead of LVDT(Linear Variable Differential Transformer). Angle change of tilt sensor shows structural behavior by the change of the resistor values which is presented to voltage. Moreover, the maximum deflection was calculated by changing the deflection angle which was calculated as V(measured voltage) ${\times}$F(factor) to deflection. The experimental tests were carried out to verify the developed deflection estimation techniques. Because the base of tilt measuring is the gravity, uniform measurement is possible independent of a measuring point. Also, measuring values were showed very high accuracy.

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.