Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System (이산화티탄 광촉매 환기장치의 오염물질 저감 실험)

  • Song, Yong Woo
    • Land and Housing Review
    • /
    • v.13 no.2
    • /
    • pp.117-123
    • /
    • 2022
  • In this study, titanium dioxide photocatalyst was applied to the ventilation system to reduce particulate matter and nitrogen oxides (NOx), which are representative indoor harmful substances. A reaction device capable of installing an ultraviolet lamp was designed and manufactured so that the pollutant decomposition effect of the titanium dioxide photocatalyst identified through previous studies could be applied indoors. The reaction device was used on the indoor ventilation system and applied to the Mock-Up test. As a result of the Mock-up test, the NOx reduction performance according to the change in air volume once per hour and five times per hour was confirmed. As a result, it was confirmed that as the number of ventilation increases, the NOx reduction time decreases proportionally, and the reduction performance increases.

보일러사도 환기시장 간다

  • Korea Boiler Engineering Association
    • 보일러설비
    • /
    • no.3 s.158
    • /
    • pp.144-147
    • /
    • 2007
  • 원자재 가격 상승과 달러화 약세 등의 영향으로 내수시장과 수출시장 모두에서 어려움을 겪고 있는 보일러 제조업체들이 일제히 환기시장으로 눈을 돌리면서 시장 쟁탈전이 뜨거워 지고 있다. 실내공기 오염악화를 이유로 공동주택과 관련 시설 등에 대한 환기시스템 설치를 의무화하는 '다중이용시설 실내공기질 관리법'이 지난해 발효되면서 주택 환기시스템 관련 수요는 매년 확대될것으로 전망되고 있기 때문이다. 실제로 환기시장 규모는 2004년 500억원대에서 2005년1000억원 규모로 성장했고 지난해에는 2200억원대를 기록했다. 업계관계자들은 올해 환기시장의 규모를 약 3500억원대로 예상하고 있고 내년에는 5500억원대까지 성장할 것으로 전망하고 있다. 이에 따라 이 시장에 진출한 보일러사들은 일제히 신제품을 발표하고 나섰고 최근에는 경동나비엔과 대성쎌틱이 새롭게 시장에 진입한 상태다. 주요 보일러사들이 출시한 환기시스템의 특장점과 마케팅 방향등에 대해 알아봤다.

  • PDF

업무용빌딩 소재 사무실의 실내공기질 평가사례

  • Jeong, Ji-Yeon;Lee, Byeong-Gyu;Lee, Gwang-Yong
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.94-97
    • /
    • 2005
  • 서울, 인천, 광주, 그리고 부산지역의 대형업무용 빌딩 소재 36개 사무실을 대상으로 사무직 근로자의 실내환경에 대한 인식, 신체증상경험, 사무실환경관련 태도를 알기위한 설문조사와 그리고 실내환경에 영향을 미치는 인자에 대한 실태조사결과 자신이 근무하고 있는 사무실 환경에 대해 만족하지 못한 근로자들이 많았으며, 신체이상 증상 경험유무에 있어서도 빌딩증후군 관련 증상을 경험한 사람이 많은 것으로 조사되었다. 실내환경질에 영향을 미치는 요인에 대한 평가에 있어서도 겨울철 경우 실내의 상대습도가 매우 낮아 불편감을 초래하고 있는 것으로 조사되었고, 실내공기 오염의 지표물질인 이산화탄소 농도에 있어서도 최고치 농도가 1,000ppm을 초과하는 사무실이 33.3%인 12개 사무실로 나타나 실내환기에 있어 문제가 있는 것으로 조사되었다. 대부분의 실내공조설비는 주로 온도조절 즉 냉${\cdot}$난방 조절목적으로 주로 이용하고 있는 것으로 나타나 신선외기공급을 통한 실내환기 개념에 있어서는 인식이 낮은 것으로 평가 되었다.

  • PDF

Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers (핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang;Kwon, Jeong-Tae;Park, Gyung-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1789-1794
    • /
    • 2009
  • In the present study, the cooling performance characteristics on environment changes of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP on an air velocity, an indoor/outdoor temperature and an indoor/outdoor relative humidity were obtained. Fin types of PF heat exchanger were a triangler and squarer form. The experimental data for the three kinds of heat exchangers were measured using the air-enthalpy calorimeter. Performance of PF A/C was more excellent than that of a fin-tube A/C. Also, the performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin. As the air velocity, the indoor temperature and the indoor relative humidity increase, capacity and COP increase. And as outdoor temperature increases, capacity and COP decrease. But, the performance change on the outdoor relative humidity was insignificant.

A numerical Study for Improvement of Indoor Air Quality of Apartment House (공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.521-530
    • /
    • 2009
  • This study has been made to execute a research in order to lead the improvement of indoor air quality, examining the indoor ventilation characteristics by using a numerical analysis method. To this end an extensive parametric investigation are made according to various external flow variables such as main wind direction and wind speed by season, building layout design, and location of ventilators, etc. in Daedeok Techno Valley, one of large-scaled apartment in Daejeon. It is observed there was a significant difference of main wind direction between summer and winter. The main wind direction in summer was a south wind, and on the contrary the direction in winter is northnorthwest, which is similar to the average main wind direction for 10 years. One of the important calculation results is that the change of wind direction causes a significant effect on the apartment ventilation by the change of pressure difference around each complex of apartment. In case of favorable area of ventilation, the indoor ventilation rate can meet 0.7 ACH from the standard value only with natural ventilation. On the contrary, in other area the value was much lower than the standard value. If the calculation result applies to the design of layout apartment or placement of ventilators, it will be greatly helpful to the energy saving because it can be parallel with the natural ventilation to help securing ventilation rate, not much depending on the mechanical ventilation.

한국철도차량(주) 창원공장 난방 및 환기설비공사 설계 및 시공 사례

  • 임정빈
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.6
    • /
    • pp.40-48
    • /
    • 2002
  • 최근 각 공장에서는 근로자의 작업환경 개선과 생산제품의 품질향상을 위하여 건물 내 냉.난방 설비를 적용하여 운영하고 있으나 높은 층고로 인하여 겨울철 실내온도를 유지하기 위한 막대한 에너지 손실과 환기시 실내오염 공기의 신속한 배출 등의 문제로 고민하고 있는 실정이다. 따라서 한국철도차량(주) 창원공장의 난방 및 환기 설비 설계 및 시공사례를 소개하고자 한다.

  • PDF

자동차 에어컨 및 난방장치 가동에 따른 bioaerosol 노출특성

  • 이지현;조완근;서영준;강정환;이준엽;권기동
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.11a
    • /
    • pp.36-38
    • /
    • 2004
  • 겨울철 및 여름철의 자동차 실내에서의 환기장치 (heater and air conditioner)의 작동이 차내 바이오 에어로졸농도에 미치는 영향을 조사한바 가동전보다 히터나 에어컨 가동 후 미생물 농도가 감소하여 실내 환기장치는 어느정도 공기정화 기능을 하고 있는 것으로 판단된다.

  • PDF

A Practical usage of industrial local ventilation facility and energy saving in the industrial ventilation (산업용 국소환기장치 활용 및 공장환기의 에너지절약)

  • 심광진;이동호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.6
    • /
    • pp.433-442
    • /
    • 1999
  • 기원전 27세기경, 고대 이집트의 피라미드건설을 위해 앗시리아 지방에서 나일강변으로 이주한 기술자들의 집합주택에는 거의 환기구가 설치되어 있었다는 기록이 있다. 이 환기방법은 실내와 실외의 기온차에 의한 공기의 부력을 이용한 중력환기로 생각된다. 중력환기는 지금도 주물공장 등의 고온, 발열을 수반하는 작업장에서 적용되고 있으며, 이와 같이 자연력을 이용한 환기를 자연환기라 부른다.

  • PDF

A Subjective Symptom Level and Satisfaction Factor by Indoor Air Quality According to Ventilation System in Dental Clinic (치과병·의원 환기방법에 따른 실내공기질 자각증상 수준 및 근무환경 만족요인)

  • Choi, Mi-Suk;Ji, Dong-Ha;Choi, Jae-Ho
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.353-359
    • /
    • 2011
  • This study was designed to identify a subjective symptom level by Indoor air according to ventilation system in Dental Clinic. The number of respondents was 582 who work in dental clinic and period of investigation was October 2010 through January 2011. A structured questionnaire was employed to evaluate the level of participants' sociodemographics, job-related factors, work place condition, a subjective symptom. Most of respondents were answered that time for symptom to begin was at around 2 P.M. and time for symptom to feel serve pain was at around 3 P.M. and ventilation frequency per a day was often in case of individual cooling and heating system. More often natural ventilation and in case of individual cooling and heating system, the level of subject symptom was low and multiple regression analysis has found that indoor air quality related elements were main factors that influence to the feeling of satisfaction in work place. The results of this study suggest that more often natural ventilation was very important to reduce the level of subjective symptom. Thus, a management program for indoor air quality is strongly recommended by natural ventilation, maintenance man for promotion of quality of life in dental hygienist and to improve dental service and competitiveness.

환기시스템에 의한 Sick House 대책

  • Kimura, Hiroshi
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.9
    • /
    • pp.46-51
    • /
    • 2003
  • "환기"는 생활용품 등으로부터의 오염물질 및 불특정 물질의 농도 저감이 가능하기 때문에 Sick House 대책으로서의 중요한 대책기술이다. 본 고에서는 집합주택을 대상으로 한 중앙공조 환기방식 및 배기 중앙 환기방식의 사례를 보여주고, 시스템의 구성기술과 오염물질의 농도 저감효과에 대해서 기술한다. 또한, 대표적인 오염물질인 포름알데히드의 건자재로 부터의 발산량은 온습도, 환기량 및 건자재의 표면적 비율 등의 영향인자에 따라 변화하므로, 필요 환기량은 이들의 영향요인을 고려하여야 한다는 것을 기술한다.

  • PDF