• Title/Summary/Keyword: 실내환경조절설비

Search Result 15, Processing Time 0.018 seconds

Simulation on the characteristics of the control system of an environmental control facility (실내환경조절설비의 제어시스템 특성에 관한 시뮬레이션)

  • 이종석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.251-259
    • /
    • 1998
  • Environmental control facilities are used to simulate an environment or combination of environments under which many kinds of research and tests can be performed. The design of the control system to maintain desired environmental conditions is essential to proper operation of the facility. A simulation model of the facility has been developed by analyzing each component of the system thermodynamically with necessary properties and heat transfer relations. Using the system simulation model, the required characteristics of the control system has been investigated. PI controller is considered as the most probable controller for this kind of the facility, and electric heater power is shown as the Proper manipulated variable for temperature control.

  • PDF

업무용빌딩 소재 사무실의 실내공기질 평가사례

  • Jeong, Ji-Yeon;Lee, Byeong-Gyu;Lee, Gwang-Yong
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.94-97
    • /
    • 2005
  • 서울, 인천, 광주, 그리고 부산지역의 대형업무용 빌딩 소재 36개 사무실을 대상으로 사무직 근로자의 실내환경에 대한 인식, 신체증상경험, 사무실환경관련 태도를 알기위한 설문조사와 그리고 실내환경에 영향을 미치는 인자에 대한 실태조사결과 자신이 근무하고 있는 사무실 환경에 대해 만족하지 못한 근로자들이 많았으며, 신체이상 증상 경험유무에 있어서도 빌딩증후군 관련 증상을 경험한 사람이 많은 것으로 조사되었다. 실내환경질에 영향을 미치는 요인에 대한 평가에 있어서도 겨울철 경우 실내의 상대습도가 매우 낮아 불편감을 초래하고 있는 것으로 조사되었고, 실내공기 오염의 지표물질인 이산화탄소 농도에 있어서도 최고치 농도가 1,000ppm을 초과하는 사무실이 33.3%인 12개 사무실로 나타나 실내환기에 있어 문제가 있는 것으로 조사되었다. 대부분의 실내공조설비는 주로 온도조절 즉 냉${\cdot}$난방 조절목적으로 주로 이용하고 있는 것으로 나타나 신선외기공급을 통한 실내환기 개념에 있어서는 인식이 낮은 것으로 평가 되었다.

  • PDF

실내공기질 향상을 위한 환경친화형 바닥공조시스템

  • 조동우
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.32-40
    • /
    • 2004
  • 바닥공조시스템(underfloor air distribution system)은 건물 내에서 공기흐름을 바닥을 통해 조절하는 방식으로 전통적인 천장공조 방식을 대체할 새로운 시스템으로 평가받고 있다. 일반적으로 바닥 공조시스템은 공조기 등에서 송풍되는 공조공기가 억세스 플로어 하부의 바닥공간으로 전달되고 바닥급기구를 통해 실내로 송풍되는 구조를 이루고 있다. 바닥공조시스템의 이점은 전통적인 천장공조 방식에 비해 실내공기의 질(IAQ)이 향상되며 에너지의 절감이 가능하다는 점을 들 수 있다. (중략)

  • PDF

Task/Ambient Air-Conditioning System의 연구 개발사례 및 향후 과제

  • 타나베신이치
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.9-17
    • /
    • 2004
  • 차세대의 공조시스템을 논의하는 데 있어서 잊어서는 안 되는 키워드 중의 하나가 “Task/Ambient Air-Conditioning System”이 있다. 이것은 기존의 실내온열환경을 균일하게 조절한다는 개념에서, 거주역(Task-zone)에 대해서는 고품질의 환경을, Ambient-zone에 대해서는 다소 완화된 환경을 제고하고자 하는 생각으로, 퍼스널 공조와 같은 고도화된 공조시스템에서 자연환기의 이용에 이르기까지 폭넓은 범위에 미치고 있다. (중략)

  • PDF

Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season (고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향)

  • 최영하;이재한;박동금;권준국;엄영철
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.164-168
    • /
    • 1999
  • 온실은 동절기 난방을 주목적으로 설비되어 년중 작물재배 시는 하절기 온실내부 온도가 필요이상으로 상승하여 실내온도가 35-4$0^{\circ}C$ 정도로 올라가는데 이러한 상태에서의 온도는 많은 작물의 생육적온을 벗어난 온도로서 고온장해를 나타낸다. 이 같은 문제점을 해결하기 위해 몇 가지 냉방방법이 알려져 있는데 에어컨 등과 같은 냉방장치를 이용한 기계적 냉각방식과 수분증발을 통한 증발식 냉각방식으로 대별되며 이중 기계적인 냉방방식은 설비나 유지관리 면에서 비용이 많이 들어 비경제적이고, 증발냉각 방식중에서도 Fan and Pad 법이 가장 효과가 좋은 것으로 알려져 있으나 이역시 설치 및 유지비가 많이 들고, vep의 탈부착이 어려워 고정시켜놓을 경우 동계 광투과에 방해가 되는 등의 문제가 많다. (중략)

  • PDF

공기순환형 구조체 축열 공조시스템

  • 이정재;정광섭
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.8
    • /
    • pp.15-18
    • /
    • 2002
  • 축열 공조방식 중 현재 가장 많이 보급되고 있는 방식은 빙축열 방식과 수축열 방식이다. 본래 축열식 공조는 열원 용량을 감소하고, 값싼 심야전력을 통해서 운전비용(running cost)의 절감을 목적으로 하지만, 열을 저장하기 위한 "축열조"가 필요하므로, 필연적으로 초기투자비(intial cost)의 증가를 동반하며, 기존의 건물에는 쉽게 적용할 수 없는 등의 문제점이 있다. 따라서 축열을 위한 초기비용을 증가시키지 않는 축열식 공조방식으로서 건축물 자체가 가지는 높은 열용량에 착안하여 구조체 축열에 관한 연구가 최근 활성화되고 있다. 구조체 축열은 건축물 그 자체를 축열 매체로 이용하기 때문에 별도의 축열조가 필요 없고, 구조체 로부터의 "복사"형태로 거주영역에 직접적으로 작용하여 실내의 온열환경을 향상시킬 수 있다. 이 때문에 2차측 공조기의 용량을 절감시킬 수 있고, 축열 부위에서의 열반송이 필요없는 등, 구조체 축열 시스템은 기존의 빙축열과 수축열 방식에서는 없는 여러가지 장점을 가지고 있다. 구조체 축열 공조시스템은 기존의 공조시스템 중에서 급기구 부위만을 변경하여 주간에서 종래의 공조시스템과 같이 실내로 공조 공기를 급기하고, 야간에는 급기구에 설치된 댐퍼를 조절하여 천정면으로 공조 공기를 급기함으로써 구조체에 열을 축열시키는 방안이다. 본 시스템은 기존의 설비시스템을 이용하여 건축물의 구조체를 축열, 공조개시전 및 주간의 부하를 대폭 줄임으로써 에너지를 절감시킬 수 있다는 장점을 갖는다. 따라서 구조체 축열 공조시스템은 "지구환경 유지.전력부하 평준화.안전성.에너지 절약.비용절감.쾌적성"의 모든 조건을 만족시키는 유력한 차세대 공조 방식이 될 것으로 판단되며, 본 보에서는 공기순환형 구조체 축열시스템을 소개하고자 한다.

  • PDF

A Study on Influences of Buckminster Fuller in Contemporary Architecture (벅민스터 퓰러가 현대건축에 미친 영향에 관한 연구)

  • 정연전;전명현
    • Korean Institute of Interior Design Journal
    • /
    • no.19
    • /
    • pp.45-52
    • /
    • 1999
  • This study is on Buckminster Fuller, who is generally known as a structure engineering architect, and his influences. Fuller's radical and utopian ideas and designs were regarded as 'paper architecture'. But considering today's high cost of energy and the limited natural resources, Fuller's Dymaxion theory must be re-evaluated. Fuller's influences on the contemporary architecture are summarized as follows. 1) His idea of controlling the environment through the use of technology influenced today's 'High-Tech' architects. Architecture is no-longer designed purely by its formal character, but becomes a tool of investigating environmental significance of modern technology. 2) Through systemizing mechanical equipment, Dymaxion House prototype, and aggregation of high-tech mechanical equipments, influenced Archigram & Metabolist's capsule idea. It is expressed as a plug-in module equipment of 'High-Tech' architecture which has flexible interior with mechanical exterior image. 3) Megastructure. The Manhattan dome project gave an influence to many engineer/architects who tried to achieve an ideal artificial environment. This is in connection to 1960's utopian projects. Today's megastructures show new possibilities in urbanism and architecture. Fuller's comprehensive idea of humans living in harmony in the universe shows possibilities not only in structural engineering, but in solving various problems that confront today's architecture.

  • PDF

Experimental Study on the Indoor Thermal Characteristics for Floor Radiant Heating System (바닥복사 난방시스템의 실내 열환경 특성에 대한 실험적 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.3
    • /
    • pp.1-12
    • /
    • 2021
  • In this study, the effects of various operational conditions for floor radiant heating system were researched by experiments. Hot water supply set temperature, indoor air set temperature and supply water flowrate were considered as operational conditions. The control method for this system is On-Off control of automatic thermostatic valve. The purpose of this study is to evaluate indoor thermal control characteristics and energy performance, respectively. As a result, if lower supply water temperature is applied, the supply and return temperature difference is reduced and energy consumption of heat supply is also reduced.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Design and Operation Guideline (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(III): 도시가스 및 수송용 - 기술지침(안) 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • In this study, to optimize the production and utilization of biogas for organic waste resources, the precision monitoring of on-site facilities and the energy balance by facility were analyzed, and the solutions for field problems were investigated, and the design and operation guidelines for pretreatment facilities and generators were presented. Gas pre-treatment is required to solve frequent failures and efficiency degradation in operation of high quality refining facilities, and processing processes such as desulfurization, dehumidification, deoxidization, dust treatment, volatile organic compounds, etc. Since these processes are substances that are also eliminated from the high-quality process, quantitative guidelines are not presented in the gas pretreatment process, but are suggested to operate during the processing process as a qualitative guideline. In particular, dust, siloxane, and volatile organic compounds are the main cause of frequent failure of high-quality processes if they are not removed from the gas pretreatment process. Design of the biogas high-quality process. The operation guidelines provide quality standards [Methane content (including propane) of 95% or more] with 90% or more utilization of the total gas generation, two systems, and a margin of 10% or more. It also proposed installing gas equalization tank, installing thermal automatic control system for controlling equalization of auxiliary fuel, installing dehumidification device at the back of high quality for removing moisture generated in the process of gas compression, installing heat-resisting facilities to prevent freezing of facilities in winter and reducing efficiency, and installing membrane facilities in particular.

Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands (간척지 온실의 환기 및 냉방 특성 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. The climatic conditions around seven major reclaimed land areas with a plan to install advanced horticultural complexes in Korea were analyzed. The characteristics of natural ventilation and temperature rise through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. Results of comparing the ventilation rate of the greenhouse according to the presence or absence of plants showed the greenhouse with plants had the lower ventilation rate, but the smaller rise of indoor temperature due to the evapotranspiration of plants. In the greenhouse with plants, the number of air changes was in the range of 0.3 to 0.9 volumes/min and the average was 0.7 volumes/min. The rise of indoor temperature relative to outdoor temperature was in the range of 1 to $5^{\circ}C$ and the average $2.5^{\circ}C$. The natural ventilation performance of the experimental greenhouse constructed in the reclaimed land almost satisfied the recommended ventilation rate in summer and the rise of indoor temperature relative to outdoor temperature did not deviate considerably from the cultivation environment of plants. Therefore, it was determined that the greenhouse cultivation in Saemangeum reclaimed land is possible with only natural ventilation systems without cooling facilities. As the reclaimed land is located in the seaside, the wind is stronger than the inland area, and the fog is frequent. This strong wind speed increases the ventilation rate of greenhouses, which is considered to be a factor for reducing the cooling load. In addition, since the fog duration is remarkably longer than that of inland area, the seasonal cooling load is expected to decrease, which is considered to be advantageous in terms of the operation cost of cooling facilities.