• Title/Summary/Keyword: 실내오염물질

Search Result 318, Processing Time 0.022 seconds

Development of Real-time Monitoring Platform for Indoor Air Quality Using Air Quality Sensors (AQ센서를 활용한 실내 대기 질 실시간 모니터링 플랫폼 개발)

  • Oh, Sang-Heon;Kim, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.206-209
    • /
    • 2018
  • According to data released by the WHO(World Health Organization), the death toll from indoor air pollution in 2016 was about 3.8 million. While many people are aware of outdoor air pollution, indoor air pollution is getting less attention. Recently, however, indoor air pollution has also become a big problem, raising many issues. Frequent indoor activities such as cooking and heating produce various pollutants, which can cause children and elderly with weak immune systems to be exposed to pollutants, which can cause serious health problems such as poor lung function and respiratory diseases. Therefore, in this paper, the IoT(Internet of Things) platform that measures and monitors indoor air quality using AQ(Air Quality) sensors is developed so that data can be monitored in real time through applications and reactive web.

  • PDF

Effect of Mechanical Ventilation System on Improvement of Indoor Air Quality in A Newly Built Apartment and B Department Store (A신축아파트 및 B백화점에서 기계환기에 의한 실내공기질의 개선 효과)

  • Park, Jeong Ho;Lee, Sang Hyuk;Kim, Hyoung Kab
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.38-45
    • /
    • 2014
  • 본 연구에서는 기계환기에 의한 실내공기질 개선효과를 현장실험을 통해 파악하기 위해 환기설비를 갖춘 A 신축아파트와 다중이용시설인 B 백화점을 연구 대상으로 하였다. A 신축아파트에서는 새집증후군 등 주요 실내공기오염의 원인물질인 VOCs 및 HCHO를 측정 대상물질로 선정하고 미환기 상태에서 16가구에서 전반적인 신축아파트의 실내공기오염 특성을 파악하였으며, 이중 상대적으로 TVOC 농도가 높은 2가구를 대상으로 환기전후의 농도 특성을 파악하였다. B 백화점에서는 $CO_2$ 및 HCHO를 대상물질로 선정하고 1~7층별로 미환기시와 기계환기 1시간 이후의 농도 특성을 통해 환기에 의한 저감율을 파악하였으며, 이후 환기시설 정상가동 상태에서 3년간 실내공기오염물질의 농도 특성을 파악하였다. 미환기 상태에서 A 신축아파트의 VOCs 및 HCHO 농도는 일부 지점에서는 에틸벤젠, 자일렌 등의 농도가 실내환경기준을 초과하고 있었다. 특히 환기전후의 TVOC 농도 특성은 A-1 지점의 경우 미환기시 $3,547{\mu}g/m^3$에서 환기시 $961{\mu}g/m^3$ 그리고 A-2 지점의 경우 미환기시 $3,117{\mu}g/m^3$에서 환기시 $594{\mu}g/m^3$으로 환기에 의해 각각 73%, 81% 저감율이 나타났다. 또한 개별 VOCs 및 HCHO물질별 환기에 의한 저감율은 31.4~96.7%로 나타났으며, 환기이후 모든 물질이 실내기준보다 훨씬 낮은 수준으로 나타났다. B 백화점에서는 평균 $CO_2$ 농도는 미환기시 855 ppm에서 기계환기 1시간 이후 580 ppm으로 약 32% 저감되었으며, HCHO의 평균농도도 $251{\mu}g/m^3$에서 $70.3{\mu}g/m^3$으로 약 72%의 저감되는 것으로 나타났다. 이후 환기시설 정상가동 상태에서 3년간 실내공기질의 측정결과 지속적으로 실내환경 기준을 만족하였다. 최근 실내공기질 개선을 위해 다양한 개선 방법이 소개되고 있으나, 이중 기계환기는 신축아파트 및 다중이용시설 등에서 실내공기질을 실내환경기준 이하로 지속적이고 쾌적하게 유지할 수 효과적 방법으로 고려된다.

Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System (이산화티탄 광촉매 환기장치의 오염물질 저감 실험)

  • Song, Yong Woo
    • Land and Housing Review
    • /
    • v.13 no.2
    • /
    • pp.117-123
    • /
    • 2022
  • In this study, titanium dioxide photocatalyst was applied to the ventilation system to reduce particulate matter and nitrogen oxides (NOx), which are representative indoor harmful substances. A reaction device capable of installing an ultraviolet lamp was designed and manufactured so that the pollutant decomposition effect of the titanium dioxide photocatalyst identified through previous studies could be applied indoors. The reaction device was used on the indoor ventilation system and applied to the Mock-Up test. As a result of the Mock-up test, the NOx reduction performance according to the change in air volume once per hour and five times per hour was confirmed. As a result, it was confirmed that as the number of ventilation increases, the NOx reduction time decreases proportionally, and the reduction performance increases.

공기청정기 기술의 진보과정과 향후 방향

  • 박종훈;염봉열;윤성진
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.4
    • /
    • pp.27-30
    • /
    • 2004
  • 최근 주거환경의 악화와 웰빙의 열풍으로 인해 실내 공기 및 물과 관련된 제품들의 개발이 활발히 일어나고 있다. 본고에서는 공기청정기의 변천사와 기반 연구 및 향후 진행방향에 대하여 논한다. 최근 중국에서의 황사가 연일 매섭게 불어오고 있고, TV나 신문, 잡지 등 매스컴에서는 신축 건물이나 아파트, 공공장소의 실내 공기질의 심각성에 대해 언급하며, 이에 대한 다양한 해결책이 제시되고 있다. 미국이나 일본 등 선진국에서는 이미 실내 공기를 오염시키는 유해가스 및 미생물, 방사성 동위원소 등의 원인물질을 규명하고, 원인물질에 따른 실내 공기 청정화 방법 등을 제시하거나 해결하기 위하여 많은 연구가 이루어지고 있다.(중략)

  • PDF

An Experimental Study on the Diffusion of VOCs & Analysis of Distribution by CFD Method in a Room (ASTM법을 이용한 휘발성유기화합물의 실내 확산실험 및 실내농도분포의 수치해석)

  • 이상권;백광욱;정진도;김상진
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.281-282
    • /
    • 2002
  • 휘발성유기화합물질 (Volatile Organic Compounds, VOCs)은 오존층을 파괴시키는 염소화합물과 광화학 스모그를 형성하는 촉매로 작용하는 주요 대기오염 물질일 뿐만 아니라 VOCs 자체로도 인류의 건강을 위협하는 물질이다. 특히 휘발성유기화합물은 물질의 종류가 수십 종에 이르며 석유화학산업, 도료산업 등의 고농도 발생사업장과 상대적으로 낮은 농토수준이기는 하지만 일상생활에서 절하게 되는 자동차, 주유소, 세탁소 등의 시설을 통해 지속적으로 환경계에 배출되는 등 발생원이 다양하며 측정분석방법에 내재된 어려움으로 인하여 다른 일반적인 대기오염물질에 비하여 여러 가지 측면에서 적절한 관리가 힘든 것으로 알려져 있다. (중략)

  • PDF