• Title/Summary/Keyword: 실내설정온도

Search Result 92, Processing Time 0.021 seconds

On-line Optimal Control Technology for Central Heating System (중앙난방시스템의 온라인 최적제어기법에 관한 연구)

  • Ahn Byung Cheon;Choi Sang Gon;Cho Sung Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.140-146
    • /
    • 2005
  • The on-line optimal control algorithm for central heating system has been researched for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as indoor heating load and outdoor temperature variation. This study has been done by using TRNSYS Program in order to analyze the central heating system. The optimal control algorithm shows good energy Performances in comparison with the conventional one.

Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material (목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석)

  • Seo, Jungki;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-359
    • /
    • 2017
  • Many researches and policies have been carried out for saving energy in buildings. However, there are a few studies of thermal characteristics of wood-based materials that have been widely used as structural materials and finishing materials in buildings. In this study, thermal bridging areas were found to investigate thermal performance of residential building using non wood-based materials and wood-based materials. And heat transfer analysis of 16 case studies according to composition of structural materials and finishing materials was conducted. Also in this experiment, Physibel Trisco was used as the heat transfer analysis simulation tool, which conforms to the calculation method of ISO 10211. Analytical modeling was also carried out according to the ISO 10211, and the boundary temperature conditions were set at room temperature $20^{\circ}C$ and outdoor temperature $-11.3^{\circ}C$ (Seoul standard) according to the energy saving design standard in South Korea. Applied structures are classified according to the cases of concrete structure with non wood-based finishing materials, concrete structure with wood-based finishing materials and wood structure. Analyzed building elements were divided into a wall, a roof, an interlayer floor and a bottom floor. As a result, it can be confirmed that the thermal bridge of the concrete structure and wood structure were caused by the geometrical and material causes. In addition, the structural thermal bridge was caused in the discontinuity of the insulation in the concrete structure. Also it was confirmed that the linear heat transfer coefficient of the wall decreases when the wood-based materials are applied to the concrete structure.

Implementation of A Monitoring System using Image Data and Environment Data (영상정보와 환경정보를 이용한 실내 공간 모니터링 시스템 구현)

  • Cha, Kyung-Ae;Kwon, Cha-Uk
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The objective of this study is to design a system that automatically monitors the state of interior spaces like offices where lots of people are coming and going through image data and environment data, which includes temperature, humidity, and other conditions, and implement and test related application programs. In practice, there are lots of image data automatically obtained by unmanned equipments, such as certain types of CCTVs, for monitoring situation in usual interior spaces. This image data can be used as a more effective manner by establishing a system that recognizes situation in specific interior spaces based on the relationship between image and environment data. For instance, it is possible to perform unmanned on/off controls for various electronic equipments, such as air conditioners, lights, and other devices, through analyzing the data acquisited from environment sensors (temperature, humidity, and illumination) as dynamic states are not maintained for a specified period of time. For implementing these controls, this study analyzes environment data acquisited from temperature and humidity sensors and image data input from wireless cameras to recognize situation and that can be used to automatically control environment variables configured by users. Experiments were applied in a laboratory where unmanned controls were effectively performed as automatic on/off controls for the air conditioner and lights installed in the laboratory as certain motions were detected or undetected for a specified period of time.

A Study on the Evaluation of Thermal Performance of Aluminium Alloy Window Frame considering 2D Steady-state Heat Transfer applied to Educadtional Facility (2차원 정상전열해석을 통한 교육시설의 알루미늄 창호 열성능 평가에 관한 연구)

  • Kang, Jung-Hun;Kwak, Young-Kuhn;Noh, Seung-Uk;Park, Dae-Ho;Lee, Ju-Ho;Hong, Wan-Pyo;Hwang, In-Kyu;Park, Tong-So
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.122-125
    • /
    • 2011
  • 본 연구에서는 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열성능 평가를 수행하였다. 교육시설의 주요 창호재료로 적용된 알루미늄은 열전도율이 $175 \;Kcal/m^2h^{\circ}C$ 정도로 플라스틱 소재와 비교하여 매우 불리하여 기존 시설에 설치된 알루미늄 창호는 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 합금 창호의 열성능 평가에 관한 연구를 수행하여 다음과 같은 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물의 에너지절약설계기준의 [별표 6] 중부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 [별표 7]의 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 해석한 결과 열관류율은 알루미늄 합금 창호는 $U=9.631 \;W/m^2K$, 복층유리 $U= 2.382 \;W/m^2K$로 여름철과 겨울철 동일한 해석결과치가 산출되었다. (2) 산출된 열관류율 해석결과를 건축물의 에너지절약설계기준 [별표 3] 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반복층창 성능기준인 $4.0 \;W/m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열량이 손실됨을 보여 주고 있다.

  • PDF

Heating and Cooling Energy Demand Analysis of Standard Rural House Models (농어촌 주택 표준모델의 냉난방에너지요구량 분석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3307-3314
    • /
    • 2012
  • The annual energy demand of the standard rural house models was analyzed using the DesignBuilder. Indoor temperature set-point, U-value of outer wall, type of window, and degree of ventilation were selected as simulation parameters. In all the simulation cases, heating energy demand was higher than cooling energy demand regardless of the building size. When the lower U-value of the outer wall was applied to account for the thicker insulation layer, heating energy demand was decreased while cooling energy demand was increased. However, it is better to reduce the area of outer wall which is directly exposed to outdoor air because reducing the U-value of the outer wall is not effective in decreasing heating energy demand. Among the four different window types, the double skin window is most favorable because heating energy demand is the lowest. For a fixed infiltration rate, higher ventilation rate resulted in an increased heating energy demand and had minor impact on cooling energy demand. As long as the indoor air quality is acceptable, lower ventilation rate is favorable to reduce the annual energy demand.

Mix Design and Physical Properties of Concrete Used in Seongdeok Multi-purpose Dam (성덕 다목적댐 콘크리트의 배합설계 및 역학적 특성)

  • Kim, Jin-Keun;Jang, Bong-Seok;Ha, Jae-Dam;Ryu, Jong-Hyun;Go, Suk-Woo;Kim, Jeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.517-520
    • /
    • 2008
  • Gravity dam use self weight to stand external force like hydraulic pressure. In general, gravity dam concrete is divided into internal and external concrete. Seongdeok dam is gravity dam which is being constructed in Cheongsong-gun, Gyeonsangbuk-do. And upstream cofferdam was constructed to examine the temperature crack due to hydration heat and to decide the height of placement. In this study, we examined the mix design of internal/external concrete and physical properties(compressive strength, adiabatic temperature rise). And we also performed laboratory tests to verify exothermic properties. Lastly, we measured the hydration heat and thermal stress of upstream cofferdam.

  • PDF

Study on Analysis and Evaluation of Performance for Evacuated Tubular Solar Collector System (진공관형 태양열 집열장치의 성능평가 및 해석 연구)

  • Chun, Tae-Kyu;Ahn, Young-Chull
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.112-119
    • /
    • 2013
  • The thermal performance for test system with evacuated tubular solar collector is experimentally investigated to obtain the basis data for developing new type solar collector. For this purpose, the test system was designed using CATIA and then after being manufactured, the system was tested using evacuated tubular solar collector. Numerical analysis, furthermore, was performed using ANSYS Fluent V.13 for glass evacuated tubular solar collector. The results showed that as setting temperature difference(${\Delta}T$) of system was increased, total operating(working) time was almost same in all cases, even though operating count was decreased. The results of numerical analysis showed that as temperature of solar absorber in glass evacuated tubular solar collector was high, the drop-rate of temperature of center part was increased.

Cause of undeveloped primordium formation according to incubation temperature of new oyster mushroom cultivar 『Heuktari』 for bottle cultivation (병재배용 느타리 품종 『흑타리』의 배양온도에 따른 미발이 관계 규명)

  • Choi, Jong In;Kim, Jeong Han;Gwon, Hee Min;Lee, Yun Hae;Shin, Bok Eum;Gu, Ok;Ha, Tai Moon;Jung, Gu Hyun
    • Journal of Mushroom
    • /
    • v.18 no.4
    • /
    • pp.317-322
    • /
    • 2020
  • This experiment was conducted to solve the failure of fruiting body production in the bottle cultivation of the oyster mushroom cultivar 'Heuktari'. The effects of incubation temperature on primordium formation and fruiting body yield of the oyster mushroom cultivar 'Heuktari' were investigated. The proper temperature for mycelium growth of 'Heuktari' on potato dextrose agar (PDA) medium is 23-26℃. The mycelial growth of 'Heuktari' was faster than that of Chunchu 2ho. During mycelial culture in sawdust medium, the temperature of the medium in the bottle initially increased, reached the highest point in the middle of the culture, and then decreased. The higher the set temperature, the shorter the incubation period. When the incubation temperatures were 20℃ and 24℃, respectively, the undeveloped primordium formation rates were low (1.8% and 4.2%, respectively). However, the rate of undeveloped primordium formation increased, and the yield decreased at incubation temperatures of 16℃ and 28℃. Mushroom farms that set incubation temperatures to 18℃ and maintained the medium temperature at less than 28℃ showed undeveloped primordium formation rates ranging between 0.3-0.8%. The rate of undeveloped primordium formation increased and the yield decreased in the farms with high incubation temperatures (above 28℃). We found that in order to reduce undeveloped primordium formation, the air inside the incubation room should be circulated continuously so that the temperature of the medium does not rise above 28℃, and dense incubation conditions should be avoided.

Moisture Contents Setting according to Growth Stages of when the Cultivation of Gastrodia elata in Indoor Facilities (천마 실내시설재배 시 생육단계별 수분함량 설정)

  • Kim, Chang Su;Kim, Hyo Jin;Seo, Sang Young;Ahn, Min Sil;Kim, Hee Jun;Lee, Wang Hyu
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.10a
    • /
    • pp.77-77
    • /
    • 2018
  • 천마(Gastrodia elata)는 연중생산을 위해 실내시설 재배 시 생육모델을 구죽하고, 생육단계에 따른 온도, 수분, $CO_2$ 등 환경 조건 설정이 필요하다. 본 연구는 천마의 생육단계 중 괴경형성기와 괴경비대기의 수분함량을 설정하여 최적의 환경조건을 찾기 위해 수행하였다. 먼저 괴경형성기 수분함량 공급은 괴경형성기에 -20kPa, -30kPa, -40kPa로 처리하여 120일간 배양한 뒤, 괴경비대기를 -40kPa로 고정하여 60일간 배양하였다. 반면, 괴경비대기 수분함량 공급은 괴경형성기를 -30kPa로 고정하여 120일간 배양한 뒤 괴경비대기에 -20kPa, -30kPa, -40kPa, -50kPa로 처리하여 60일간 배양하였다. Tensiometer(토양수분장력계)기를 설치하여 수분을 공급하였고, FDR센서 (UbiMas, CoCo sensor, Frequency domain reflectometry type)를 배양토의 깊이 5 cm와 15 cm에 2개를 설치하여 평균값으로 수분함량을 측정하였으며, 전체수량, 성마율, 종마율 등을 조사하였다. FDR센서로 수분함량을 측정한 결과, -20 kPa은 43.3%, -30 kPa은 34.7%, -40 kPa은 29.8%, -50 kPa은 25.3%로 측정되었다. 괴경형성기 수분함량 처리 후 수확기의 상자 당 전체수량은 -30 kPa일 때 985 g으로 가장 많았고, -40 kPa일 때 912 g, -20 kPa일 때 703 g으로 처리간의 유의적인 차이를 보였다. 성마율은 수분함량처리별 각각 25, 34, 30% 이었고, 종마율은 수분함량처리별 각각 53, 73, 65%로 나타났다. 따라서 -30 kPa 처리구가 다른 처리구에 비해 전체수량, 성마율, 종마율 등이 유의적으로 우수하였다. 괴경비대기 수분 함량 처리 후 수확기의 상자 당 전체수량은 -40 kPa일 때 992 g으로 가장 많았고, -50 kPa일 때 955 g, -30 kPa일 때 903 g, -20 kPa일 때 686 g 순으로 나타났다. -30 kPa에서 -50 kPa 사이에서는 전체 수량의 유의성 차이는 없었다. 성마율은 수분함량처리별 각각 20, 30, 35, 33%이었고, 종마율은 수분함량처리별 각각 45, 65, 75, 68%로 나타났다. 따라서 -40 kPa 처리구가 다른 처리구에 비해 전체수량, 성마율, 종마율 등이 유의적으로 우수하였다. 반면 -20 kPa 처리구는 과도한 수분으로 천마가 오히려 부패될 수 있는 환경조건이 조성됨에 따라 성마율, 종마율 등 전체적인 수량 감소에 영향을 미친 것으로 판단되었다.

  • PDF

NIR reflecting properties of TiO2/Ag/TiO2 multilayers deposited by DC/RF magnetron sputtering (DC/RF 마그네트론 스퍼터링법을 이용한 TiO2/Ag/TiO2 하이브리드 다층박막의 적외선 반사 특성)

  • Kim, Seong-Han;Kim, Seo-Han;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.158-158
    • /
    • 2016
  • 최근 화석연료의 고갈과 환경 보전 및 에너지 절약에 대한 관심이 높아짐에 따라 화석연료의 소비를 최소화하고 실내조건을 쾌적하게 유지하려는 연구가 진행되고 있다. 국내의 경우 전체 에너지 소비의 30%이상을 차지하고 있는 건물부문에서의 에너지 소비를 줄이기 위한 활발한 연구가 진행되고 있으며 이에 따른 에너지절약 소재개발이 활발하게 진행되고 있다. 1975년 이후 여러 차례에 걸친 단열강화 조치를 통해 건물에서의 에너지 소모를 줄이고 있었으나 건물의 외벽에 대한 사항으로 한정되어있었고, 또한 건물의 창 면적이 증가함에 따라 창을 통한 열손실량과 열획득량이 더욱 증가하게 되었다. 이러한 문제를 해결하기 위해 열반사유리에 대한 많은 연구가 진행되고 있다. 열반사유리는 근적외선(열선)영역의 빛을 반사시켜 실내의 열손실량 및 외부에서의 열획득량을 감소시켜 에너지의 소비를 줄일 수 있는 유리을 말한다. 이러한 열반사유리은 fresnel 방정식을 통해 빛의 파장대에 따른 반사율 및 투과도를 예측할 수 있는데, 다층박막구조인 Oxide-Metal-Oxide(OMO)구조는 Oxide의 높은 굴절률과 Metal의 낮은 굴절률을 통해 가시광영역대의 높은 투과도와 근적외선 영역의 높은 반사율을 얻을 수 있다. 또한 Metal층을 삽입함으로서 flexible한 코팅이 가능하고, 높은 carrier density와 mobility로 표면 플라즈몬 공명을 통해 특정 파장대의 반사율을 높일 수 있으므로 많은 연구가 진행되고 있다. $TiO_2$는 고굴절률 및 낮은 광흡수성의 특성을 가지는 산화물반도체로 기존의 $In_2O_3$계 산화물에 비해 값이 싸고 높은 안정성과 광촉매특성을 보이므로 외부에 노출된 환경에 적합한 재료이다. Ag는 저굴절률과 낮은 광흡수성을 가지는 재료로 금속층에 적합하다. 본 연구에서는 fresnel 방정식을 통해 반사도 및 투과도를 예측하고 마그네트론 스퍼터링법으로 다층박막을 열선인 적외선 영역에서의 반사율 및 반사 효율을 평가하였다. Index-matching 시뮬레이션을 통해 $TiO_2/Ag/TiO_2$ 다층박막의 투과도와 반사도를 이론적으로 검토하였다. 시뮬레이션 프로그램은 Macleod프로그램을 이용하였고 재료 각각의 굴절률은 Ellipsometry를 이용하여 측정하였다. 두께 40 nm 와 8 ~ 16 nm를 가지는 $TiO_2$층과 Ag층을 각각 RF/DC 마그네트론 스퍼터링법을 이용하여 Glass기판 위에 증착하였다. 직경 3 in 의 $TiO_2$, Ag 소결체 타깃을 이용하였고 스퍼터링 파워는 각각 200 W, 50 W로 설정하였고, 스퍼터링 가스는 Ar가스의 유량을 20 sccm으로 설정하였다. 작업압력은 모두 1 Pa로 설정하였고 타깃 표면의 불순물 및 이물질 제거를 위해 Pre-sputtering을 10분 진행하였다. 박막의 두께는 reflectometer와 Alphastep을 이용하여 측정하였고 Hall effect measurement를 이용하여 비저항, carrier density, mobility등 전기적 특성을 측정하였다. 또한 UV-VIS spectrometer와 USPM-RU-W NIR Micro-Spectrophotometer를 통해 광학적 특성을 측정하였고 계산 값과 비교분석하였다. 또한 열반사 특성을 평가하기 위해 직접 set-up한 장비를 이용하였다. 단열 박스에 샘플을 장착해 적외선 램프를 조사하였을 때의 열 반사효율을 평가하였고, IR Camera를 이용하여 단열 박스 내부의 온도 변화를 관찰하였다.

  • PDF