• Title/Summary/Keyword: 실내부식실험

Search Result 23, Processing Time 0.035 seconds

Evaluation of Corrosion Thickness Loss of Temporary Steel Members Exposed to A Subway Construction Site (지하철 공사현장 환경하의 가시설 강재의 부식두께감소량 추정)

  • Kim, In Tae;Jeon, Sang Hyuck;Hur, Jung Ok;Cheung, Jin Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.301-310
    • /
    • 2009
  • Steel has been widely used as a material in temporary structures. Corrosion attack often reduces the long-term durability of temporary steel members that are not protected from corrosion. In designing temporary steel structures, it is difficult to evaluate their long-term durability, since the thickness loss of steel members is not clear. In this study, laboratory and field exposure corrosion tests were performed on structural steel plate specimens, and the loss of thickness of specimens that were exposed to a subway construction site for 11 months and of specimens that were exposed to environments with controlled humidity and calcium chloride for six months were measured. Finally, a thickness loss equation was formulated based on the environmental conditions and the testing periods.

Comparison of Predacity of Nematode Predatory Fungi against Meloidogyne incognita (국내 분리 포식성곰팡이들의 고구마뿌리혹선충에 대한 포식 능력 비교)

  • 이재국;김동근;이영기
    • Korean journal of applied entomology
    • /
    • v.39 no.2
    • /
    • pp.111-115
    • /
    • 2000
  • Fifty-two nematode predatory fungi were isolated from 37 soil samples collected from eight provinces in Korea. Isolated fungi were tested their predacity against Rhabditis sp. and Meloidogyne incognita in petri dish, and against M. incognita in greenhouse pot experiments. Fifty isolates had trapping organ of adhesive networks and two isolates had adhesive column or adhesive knob. In petri dish experiments, 5 1 isolates against Rhubditis sp. and 26 isolates against M. incognita showed over 91 % of predacity; in greenhouse experiments, however, only three isolates showed over 81% of predacity. These results imply that the results from the laboratory experiments are not consistent with those from the greenhouse experiments. Therefore, to select a promising biocontrol predatory fungi for plant-parasitic nematodes, the screening experiment should be conducted in conditions close to nature.

  • PDF

The metal corrosion caused by museum indoor air pollutants (박물관 실내 대기오염물질에 의한 금속 부식 영향)

  • Kang, Dai-Ill
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.5-14
    • /
    • 2008
  • The effect of air pollutants coming from internal museum materials such as wood-based products and cements on metal corrosion have been investigated. The Oddy test and the Chamber test was employed as a corrosion test. The metal pieces after the Oddy test had different corrosion types caused by the internal museum materials. The most effective wood based product was 18T HS(E0) and 9mm plywood(F0,E0). Iron(Fe) and copper(Cu) also bronze of the Chamber test had corrosion caused by Formic acid, Acetic acid, and Acetaldehyde. The packing materials in high humidity had caused more corrosion on the surface of the metal pieces than in low humidity.

  • PDF

Experimental Studies on the Corrosion of Reinforcement Steel in Reinforced Concrete with Corrosion Inhibitors (방식재를 사용한 철근 콘크리트의 철근부식에 관한 실험적 연구)

  • Y.S Chung;G.H Han;Lee, G.G.;J.W. Jang;Park, E.K.
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.6
    • /
    • pp.175-183
    • /
    • 1997
  • 경제성장에 따른 항만구조물의 건설 및 유지관리에 관한 관심이 급격히 고조되고 있다. 이러한 항만구조물은 해양환경에 노출되어 콘크리트에 매입된 철근의 부식을 야기시키는 요인에 접해있다. 한편, 콘크리트 내부의 염분침투는 매입철근의 부식을 가속화시켜 콘크리트 구조물의 내구성에 상당히 큰 피해를 입힐 수 있다. 본 연구의 목적은 여러 가지 방식제를 사용함과 동시에 물/시멘트을 달리한 실험변수를 이용한 시험체에 대한 부식평가 및 매입철근의 적절한 부식방지 기법의 개발에 있다. 해양환경 조건을 simulation한 해수 및 담수 순환장치를 이용한 실내 시험체의 철근 부시도 평가 및 항만현장에 직접 거치된 시험체 등 다양한 조건하의 2년간의 실험이 현재 진행 중에 있다. 40주에 걸쳐 간헐 침투되는 해수조건에서 60개의 콘크리트 시험체의 철근 부시도 평가결과를 기초하여 180여개의 콘크리트 시험체를 새로이 제작하여 Half-Cell Test를 통한 Instant-Off Potential, Current Method를 통한 Corrosion current, Chloride Content 및 시험 종료후 시험체를 파쇄하여 부식된 철근의 무게측정등을 통하여 거동 및 부식을 예측.평가하고 이를 통한 부식방지기법을 개발하고자 한다.

HCP Evaluation Considering Property of Cement Mortar and Steel Corrosion (건조 상태의 시멘트 모르타르 특성과 철근 부식량을 고려한 HCP 평가)

  • Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2017
  • HCP(Half Cell Potential) method has been widely used since it is recognized as a efficient NDT(Non Destructive Technique) for corrosion detection. This work is for an evaluation of relation between corrosion amount and measured HCP in dried condition through ICM(Impressed Current Method) for accelerating corrosion. For the work, cement mortar specimens with three w/c ratios and four cover depths are prepared, and corrosion test based on ICM is performed for 6 hours, 18 hour, and 42 hours with constant 20V of electrical charge, respectively. From the test, corrosion amount increases with reduced cover depth, increasing w/c ratio, and extended corrosion period, where corrosion amount is evaluated to linearly increases with measured HCP in dried condition. In order to evaluate corrosion amount through measured HCP, the measured HCP level is firstly determined and then corrosion amount is to be compared with measured HCP, which is evaluated to be more reasonable with higher C.O.V.

Flexural Strength Evaluation of PSC Beam with Loss of PS Tendon Area (PS강재의 단면적 감소에 따른 PSC보의 휨강도 평가)

  • Park, Soon-Hyung;Kim, Yong-Tae;Youn, Seok-Goo;Kim, Eun-Kyum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.309-312
    • /
    • 2008
  • This paper describes ultimate load tests which were performed to show the effects of prestress loss and tendon corrosion on the flexural strength of post-tensioned concrete beams and the occurrence of wire fracture. Five test specimens were fabricated in laboratory with the variations of the prestress of tendons and the loss of tendon area. For two specimens, small area of tendon at the center of the beam was exposed by using diameter 25mm drill and the exposed tendon was corroded using accelerated corrosion equipment. During the tests, deflections, crack width, and strain changes were measured and acoustic events were monitored with two acoustic sensors. Tests results show that the ultimate flexural strength of test specimens with corroded tendons is smaller than the predicted flexural strength which is calculated considering the loss of tendon area. It is considered that estimation of flexural strength of PSC beams with corroded tendons is very complicated just based on the loss of tendon area obtained by one-side visual inspection.

  • PDF

Suggestion of Deterioration Curve for New-type Coating on Atmospheric Environment by Acceleration Corrosion Test (부식촉진 실험을 통한 대기환경에서 신설 도장계의 노화곡선 제안)

  • Jeong, Young-Soo;Kim, Min-Jeong;Jeon, Seok-Hyeon;Ahn, Jin-Hee;Kim, In-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.75-83
    • /
    • 2019
  • In this study, to propose the deterioration curves of urethane, ceramic, polysiloxane and fluorocarbon coating for the steel bridge, an accelerated corrosion tests were carried out. The each coating system wes applied on the top of the specimens, and circular initial defects were introduced with different diameters with 0.5, 1.0, 3.0, 5.0 mm. An accelerated corrosion test condition was used to simulate severe corrosive environment depending on ISO 20340. The deterioration curve of each coating type was evaluated based on deteriorated area from the circular defects. In order to evaluate the coating service life of installed steel bridge using deterioration curve, the acceleration coefficient was calculated at correlation between ISO 20340 and corrosivity categories by ISO 9223 based on field corrosion rate. From test results, the propagation rate of coating deterioration area was different to diameter of circular defects. In case of urethane coating, the coating service lifes of 3% deterioration area was evaluated in 31.8, 15.8, 9.9 and 3.9 years with C2, C3, C4 and C5 category.

Field Investigation of Chloride Penetration and Evaluation of Corrosion Characteristics for Deicer (염화물 침투 현장조사 및 제설제에 따른 부식특성)

  • Yang, Eun-Ik;Kim, Myung-Yu;Park, Hae-Geun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.47-52
    • /
    • 2008
  • Deicer has been generally used for prevention of a road freezing in winter, and the usage amount is increasing every year. However, deicer may induce the decrease of bond strength, surface scaling, and environmental pollution. In this study, the field test was performed to investigate the deterioration of concrete road structures used for 17 years. And, the corrosion resistance characteristics were compared for the existing deicer and eco-friendly deicer. According to the field test results, the penetration depth of limit chloride amount was about 40mm, and the average concentration of chloride was $3.45kg/m^3$ at the surface of structures. On the contrary, the carbonation depth was slight. The penetration depth of eco-friendly deicer was less than the existing deicer, and the corrosion resistance of eco-friendly deicer was higher.

Effect of Impressed Current System for Corrosion Protection of Rebars in Concrete (콘크리트 중의 철근 부식 억제를 위한 외부전원법의 효과)

  • Moon, Han-Young;Kim, Seong-Soo;Kim, Hong-Sam
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.221-230
    • /
    • 1999
  • Corrosion of rebars can occur if there are cracks, moisture and availability of oxygen or carbonation proceeds, chloride penetrates and diffuses in concrete. Once rebars in concrete corrodes, subsequently accompanied with scaling, spalling in concrete cover. As a result of them, the RC structure is seriously deteriorated. In this study, theoretical review and experiments for cathodic protection(CP) have been performed to control corrosion of rebars in concrete contained chlorides and pre-crack. For CP the impressed current system was applied, the protection effect was investigated when rebars was directly contacted with salt water due to crack and open to much chlorides in concrete. In order to investigate the effect of protection, when CP was energized for 1 year, half-cell potential, potential-decay with current density, corrosion ratio, etc. were measured. With the cathodic protection by impressed current system, the depolarized values of all specimen were met NACE Standard, the effect of 34~84% of the ratio of corrosion area and 84~86% of cross-section reduction were calculated.

Evaluation of Deicing Performance for the Eco-Friendly Deicer (친환경 제설제의 융빙성능 평가)

  • Lee, Kyung-Bae;Lee, Seung-Woo;Yoo, Hyung-Mok;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.10 no.2
    • /
    • pp.15-26
    • /
    • 2008
  • Recently, various damages such as corrosion of rebar, scaling on concrete pavement and environmental deteriorations caused by using the chloride-containing deicer have been reported. To solve these problems, several substitute deicers have been developed by other researchers. However, studies on evaluation of performance for the developed deicers have been limited in the basic laboratory testing. It is necessary to establish the resonable and systematic test procedure for evaluating the deicing performance. In this study, rational and practical test methods were set up through literature review and deicing performance of Eco-Friendly Deicer(EFD), which is a kind of low chloride-containing deicer developed by our research group, was evaluated by the presented test methods. As results of the laboratory tests, initial deicing performance of EFD was similar with that of Pre-Wetted Salt(PWS) which has been used in highway deicing and it was verified by executed field tests in twice that EFD had passable deicing performance compare with PWS.

  • PDF