• Title/Summary/Keyword: 실내기

Search Result 1,301, Processing Time 0.061 seconds

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units (3실 열펌프의 운전조합에 대한 난방성능 실험연구)

  • Kim, Ju-Hyung;Kim, Ki-Young;Kwon, Young-Chul;Park, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4197-4203
    • /
    • 2013
  • In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.

Classification of Indoor Air condition Refrigerant noise (에어컨 실내기 냉매 소음의 분류)

  • Jeong, Un-Chang;Kim, Jin-Su;Lee, Sun-Hun;Lee, You-Yub;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.254-254
    • /
    • 2014
  • 에어컨 실내기는 소비자와 근접해 있는 실내에 설치되며, 필요성에 의해 가동되므로 소비자들의 소음에 대한 반응이 민감하다. 실내기 소음에는 Fan Noise, Cricking Noise, Refringerant Noise 등이 존재한다. 이중 Refringerant Noise 의 경우 Overall Level 은 낮지만 거슬리는 소음이 발행하여 소비자의 가장 큰 불만을 초래한다. Refringerant Noise 에 대해 발생원인 및 해결 방안 측면으로의 연구는 활발히 진행 중이다. 그러나, 소음에 대한 평가 방법에 대한 연구가 이루어지지 않고 있다. 이에 본 연구에서는 에어컨 실내기 Refringerant Noise 을 대상으로 각 소음 별 특성 분석을 수행하였다. 이를 바탕으로 각 소음 별 영향인자를 도출하였다.

  • PDF

가정용 공기청정기 기술 및 시장동향

  • 김영생
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.4
    • /
    • pp.17-22
    • /
    • 2004
  • 가정용 공기청정기의 집진, 탈취, 각종 부가기능 등의 개발 현황 및 성능시험 결과와 사회환경 변화에 따른 시장 동향을 소개한다. 건강과 환경에 대한 관심이 점점 높아져 가는 사회적 분위기 속에서 특히 인간에게 직접적으로 영향을 미치는 실내 공기질에 대한 문제는 사회적으로 중대한 이슈가 되고 있다. 사회구조가 변화하면서 실내에서 생활하는 시간이 점점 길어지고 이에 따라 실내 환경이 인간에게 미치는 영향 또한 커지고 있다. 특히 실내공간에서 부유 하는 분진, 세균류와 유기화합물(volatile organic compounds : VOCs), 포름알데히드(HCHO) 등이 인체에 미치는 영향에 대한 연구 결과가 대중에게 알려지면서 실내 공기질 개선에 대한 사회적 요구가 급증하고 있는 것이 사실이다. 따라서 최근 공기청정기의 수요가 호조를 보이고 있으며, 백색가전제품 중에서도 두자리수 성장을 계속하고 있는 상품 중 하나이다. 공기청정기는 건강을 지향하는 추세가 강한 요즘, 필수품으로서 정착했으며 well-being붐을 타고 더욱 확대되고 있다.(중략)

  • PDF

A Study of Stabilizer for the Noise Reduction in Room Air Conditioner (룸에어컨 소음저감을 위한 Stabilizer에 관한 연구)

  • 서상호;이내영;이진하;진심원;임금식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.136-141
    • /
    • 1995
  • Room Air Conditioner(이하 RAC) 실내기는 열교환기, Cross Flow Fan(이하 CFF), 곡률, Stabilizer(이하 STB) 등 여러 설계인자가 소음, 풍량 및 압력 등에 상호 복합적으로 연성(Coupled)되어 있어 각 인자가 성능에 미치는 영향을 정량적으로 밝혀 내기가 쉽지 않다. 따라서 RAC 실내기의 고성능 및 저소음화를 실현하기 위해서는 실내기를 구성하는 각 인자간의 상호 관련성 및 각 인자가 소음.성능 등에 미치는 영향을 체계적으로 분석하는 것이 필수적이다. 본 연구에서는 설계인자중 소음 및 풍량에 민감한 영향을 주는 STB 위치 및 형상 등에 관하여 자세히 다루고자 한다. STB위치의 적절한 범위를 설정하기 위해 Laser Doppler Velicitimeter(이하 LDV)를 이용하여 곡률별 실내기 내부의 유속분포 및 속도 벡터를 측정하였고, CFF내부 Vortex의 정확한 위치를 찾아냈다. 또한 실내기 저소음화를 위한 소음원 규명 측면에서 실내기 내부의 난류도와 관련하여 속도 Fluctuation을 정의하고, 실험을 통해 구하였다.

  • PDF

Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination (실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구)

  • Kwon, Young-Chul;Chun, Chong-Keun;Park, Youn-Chang;Ko, Kok-Won;Seo, Dong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1487-1493
    • /
    • 2008
  • In order to investigate the cooling capacity of multi-heat pump applying an inverter compressor, the experiment on the cooling performance characteristics of heat pump with 3 indoor units was performed under the cooling standard and cooling low-temperature conditions. The system data were measured by the psychrometric calorimeter. The operation characteristics and the behavior of the cooling cycle of the heat pump with 3 indoor units were understood from the cooling capacity, COP, and P-h diagram by indoor-unit combination. The operating load and performance of the multi-heat pump depends on the indoor-unit combination. The cooling capacity and COP of the low temperature condition were larger than those of the standard one. Also the cycle was analyzed by using P-h diagram.

Numerical Simulation of Flows inside the Various Rooms for Performance Assessment of Air Cleaning System (공기청정 시스템 성능예측을 위한 실내 유동현상에 관한 수치모사)

  • 손덕영;이두환;길재흥;최윤호;김동현
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.306-316
    • /
    • 2002
  • ln this paper, flowfields inside the various rooms have been investigated. A storage room, a liv-ingroom with a kitchen in an apartment, and a hospital room are considered in the present calculations. In all cases, it was found that the average of air change rate is. similar to that of perfect mixing assumption and the location of air purifier has little effects on the average air change rate. Detailed local air concentrations show that there are regions where air is not quite purified because of non-uniform circulation of air flow. The location of air purifier has great effects on this behavior.

공기청정기 기술의 진보과정과 향후 방향

  • 박종훈;염봉열;윤성진
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.4
    • /
    • pp.27-30
    • /
    • 2004
  • 최근 주거환경의 악화와 웰빙의 열풍으로 인해 실내 공기 및 물과 관련된 제품들의 개발이 활발히 일어나고 있다. 본고에서는 공기청정기의 변천사와 기반 연구 및 향후 진행방향에 대하여 논한다. 최근 중국에서의 황사가 연일 매섭게 불어오고 있고, TV나 신문, 잡지 등 매스컴에서는 신축 건물이나 아파트, 공공장소의 실내 공기질의 심각성에 대해 언급하며, 이에 대한 다양한 해결책이 제시되고 있다. 미국이나 일본 등 선진국에서는 이미 실내 공기를 오염시키는 유해가스 및 미생물, 방사성 동위원소 등의 원인물질을 규명하고, 원인물질에 따른 실내 공기 청정화 방법 등을 제시하거나 해결하기 위하여 많은 연구가 이루어지고 있다.(중략)

  • PDF

빌딩 설비의 실무 포인트(7) - 공조기편[ I ]

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.7 s.55
    • /
    • pp.72-73
    • /
    • 1981
  • 공기조화기는 건물내에서 일하는 사람의 공기환경을 좋게 하기 위한 시설로서 실내작업자와는 밀접한 관계가 있다. 공기환경에서는 공기의 온도, 습도와 풍속유지 범위를 정하고 탄산가스, 일산화탄소 및 부유먼지 함유량을 규제하고 있다. 더욱 정기적 측정을 하여 그 기록을 보관해야 한다. 이상과 같이 실내환경에 대한 감시가 엄격해짐으로 실내환경에 신경을 써야 할 것이다. 이런 문제 때문에 공기기술자라 할지라도 공기조화기의 기능을 어느정도 이해해 둘 필요가 있다, 그래서 2회에 걸쳐 공기조화기의 기초지식과 실무 주안점을 소개할까 한다.

  • PDF

Fabrication of Compact Patch Antenna for the Indoor Repeater System (실내 간이 중계기용 소형 패치안테나 제작)

  • 손태호;송문수
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.298-300
    • /
    • 2003
  • 미국 PCS 대역 실내 간이 중계기에 사용될 수 있는 소형 안테나를 개발 제작하였다. 이동통신용 PCS 주파수는 CDMA에 비해 2배 정도 높기 때문에 건물 등 실내에서 통신하기에는 감쇠가 심하다. 따라서 건물 밖 신호를 받아서 건물의 특정부분으로 중계해주는 시스템이 필요하게 된다. 이 연구에서는 벽걸이 혹은 사진액자 형태의 중계기에 사용될 수 있는 소형이면서도 대역특성이 넓은 패치 안테나를 제작하였다. A4 크기의 중계기에 적용되는 소형 패치 안테나를 2개 배열하여 측정한 결과 S11의 -10㏈ 대역폭은 1.7 - 2.1㎓로 400㎒ 의 광대역이고, 이득 6 - 8.5㏈i 및 -l8㏈의 F/B 비 특성을 보였다.

  • PDF

Indoor Air Quality in daycare facilities (보육시설의 실내공기질 유지관리 실태)

  • Park, Jun-Seok
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.6
    • /
    • pp.28-32
    • /
    • 2014
  • 본 투고에서는 2008년 환경부의 용역으로 실시된 "보육시설의 실내공기질 진단 및 개선 시범사업"의 결과를 바탕으로 우리나라 보육시설의 실내공기 오염 실태와 함께 개선방안, 그리고 개선효과에 대하여 소개하였다. 서울, 경기, 인천 지역의 61개 시설을 대상으로 실내공기질 측정과 설문조사를 실시한 결과 폼알데하이드와 총 휘발성유기화합물은 일부시설에서 "다중이용시설 등의 실내공기질 관리법" 기준치를 초과하는 것으로 나타났다. 반면 이산화탄소와 미세먼지는 조사 대상 시설 중 50 % 이상이 기준치를 초과하는 것으로 나타났다. 따라서 보육시설의 실내공기질 개선을 위해서는 각 오염물질의 발생원별로 유지관리 대책이 필요한 것으로 조사되었다. 또한 오염원인별 분석결과, 대부분 시설의 실외오염물질 농도가 실내보다 낮게 나타나 외기의 오염이 실내에 미치는 영향은 미비한 것으로 나타났으며, 계절에 따른 실내공기오염은 동절기에 낮은 외기온도로 인하여 실내를 하기 때문에 하절기에 비해 더 높게 나타났다. 공간에 따른 오염물질의 농도는 이산화탄소와 미세먼지의 경우 아동이 늘 상주하는 교실의 오염이 가장 심한 것으로 나타났으며 폼알데하이드와 총휘발성유기화합물의 경우 놀이실의 오염도가 교실에 비해 더 높게 나타났다. 개선방안별 개선효과에 있어서는 환기계획 몇 환기설비 설치, 지하공간 습기 문제 개선에서 가장 높은 효과가 나타났다. 향후 보육시설의 쾌적하고 건겅한 실내환경의 유지관리를 위해서는 보육종사자들이 활용할 수 있는 유지관리 지침 또는 매누얼에 대한 보급이 필요할 것으로 판단된다.