• 제목/요약/키워드: 실내공기환경

검색결과 595건 처리시간 0.032초

네일샵미용실의 실내공기 중 미세먼지(PM10), 휘발성 유기화합물 (VOCs), 알데하이드류(Aldehydes)의 농도 및 업소 특성에 따른 상관성 분석 (Characteristics of PM10, VOCs and Aldehydes Levels in Nail and Hair Shops)

  • 이보람;곽수영;양원호;전상일;김정수;이기영
    • 한국환경보건학회지
    • /
    • 제43권6호
    • /
    • pp.509-515
    • /
    • 2017
  • Objectives: The purpose of this study was to assess the indoor levels of $PM_{10}$, VOCs and aldehydes in nail shop and hair salon. Methods: The field survey was conducted for 52 hair salons 52 nail shops, and 26 shop-in-shops in Seoul and Daegu city. The field technicians investigated characteristics of each shop including operating time, indoor volume, ventilation and so on. Indoor concentrations of $PM_{10}$, VOCs and aldehydes, indoor temperature and humidity were measured in 12 hair salons, 12 nail shops and 6 shop-in shops. MP Surveryor II (Graywolf, USA) was used to measure $CO_2$ concentration, temperature and humidity for 8 hours. $PM_{10}$ concentrations were measured by minivolume air sampler with Teflon quartz filter ($0.2{\mu}m$ pore size, ${\varphi}$ 47 mm, Graseby-Anderson TEF-DISKTM) for 6 hours. VOCs passive sampler (OVM 3500) was used to collect VOCs for 8 hours and analyzed by GC/MSD. Results: The $CO_2$ concentrations were $759.4{\pm}58.2$ ppm in nail shops, $731.0{\pm}72.5$ ppm in hair salons, and $656.4{\pm}31.2$ ppm in shop-in-shops. The $PM_{10}$ concentrations were $27.5{\pm}14.2{\mu}g/m^3$ in nail shops, $33.1{\pm}6.3{\mu}g/m^3$ in hair salons, and $39.0{\pm}26.9{\mu}g/m^3$ in shop-in-shops. TVOCs concentrations were $3085.4{\pm}1667.8{\mu}g/m^3$ in nail shops, $2131.1{\pm}617.3{\mu}g/m^3$ in hair salons, and $1550.3{\pm}529.0{\mu}g/m^3$ in shop-in-shops. TVOCs concentrations in nail shops were significantly higher than those in hair salons and shop-in-shops (p=0.002). Formaldehyde concentrations were $60.8{\pm}36.6{\mu}g/m^3$ in nail shops, $89.1{\pm}55.4{\mu}g/m^3$ in hair salons, and $45.1{\pm}22.5{\mu}g/m^3$ in shop-in-shops. Conclusion: TVOCs concentrations in nail shop were the highest among others. TVOC concentrations in all stores exceeded indoor air quality stand of indoor air quality control in public-use facilities, etc act.

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가 (Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool)

  • 박해동;박현희;신정아;김태호
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

지능형 무선통신용 가스 센서 모듈 구현 (The Realization on GAS Sensor Module for Inteligent Wireless Communication)

  • 김효찬;원영수;조형래
    • 한국ITS학회 논문지
    • /
    • 제11권6호
    • /
    • pp.123-132
    • /
    • 2012
  • 가스센서는 그 용도에 따라서, 자동차용(배출가스, 연료혼합 가스, 산소, 분진), 농수산 식품산업용(신선도, 저장, $CO_2$, 습도, $NH_3$, 질소산화물 가스, 유기가스, 농약 및 살충제로부터 방출되는 유독가스), 산업 의료용(석유화학제품 가스, 수소, 산소, 유독가스), 군사용(화학무기 가스), 환경 측정용(CO를 비롯한 황과 질소 등으로 구성된 대기오염가스), 가정용(LNG, LPG, 부탄, 실내공기, 습도) 등으로 매우 다양하게 사용하고 있다. 산업 현장의 유해물질 종류는 약 700종으로 알려져 있으며 이들 중 대다수의 물질은 일반적인 환경 조건에서 가스 형태로 존재한다. 본 연구에서는 이러한 유독 가스들 중에서 차량 내부 등의 밀폐된 공간에서 발생하기 쉬운 중요한 탄소(CO), 이산화탄소($CO_2$), 암모니아 ($NH_3$)의 세 가지 가스를 검출하는 휴대용 가스센서 모듈을 구현하고자 한다. 유독 가스 중에서도 가장 인명 사고의 중요한 요소인 NH3, $CO_2$, CO의 3종류 가스를 검출하는 다중 가스검출 센서에 대해 연구한다.

전국 다중이용시설의 실내공기 부유 곰팡이의 현황 및 특성 분석 (An Analysis of the Current Status and Characteristics of Airborne Fungi in Indoor Air in Multi-Use Facilities Nationwide)

  • 박용성;권순현;박송이;기선호;윤원석
    • 한국환경보건학회지
    • /
    • 제48권5호
    • /
    • pp.282-289
    • /
    • 2022
  • Background: Airborne fungi are ubiquitous in the air and exposure to an airborne fungus can be a significant risk factor. The composition of fungi has been potentially important for human health, especially for respiratory diseases like asthma and atopic dermatitis. Therefore, we attempted to ascertain what kind of airborne fungi affect human health at a nationwide level. Objectives: This study was carried out to provide information on indoor fungi distribution at multi-use facilities throughout South Korea. Methods: We classified our data by region and public facility after collection, cultivation, and identification via the sequencing of the ITS (internal transcribed spacer) region. We investigated whether or not the proliferation of HaCaT cells was affected by the identified airborne fungi. Results: In our data, the most isolated airborne fungi by region were Penicillium spp (Seoul, Daegu), Periconia sp (Gyeonggi-do), Iprex sp (Gangwon-do), Phanerochaete sp (Busan), Bjerkandera sp (Gwangju), and Aspergillus sp (Jeju-do). In the public facilities, the most detected fungi were Cladosporium sp (public transport), Penicillium sp (apartment house, retail market, financial institution, karaoke room), Bjerokandera sp (underground parking lot, public toilet, medical institution), Periconia sp (retail store), and Fusarium sp (general restaurant). Next, we selected twenty airborne fungi to examine their cytotoxicity and proliferation of human skin cells. In this experiment, the proliferation of the cells was influenced by most of the identified fungi. In case of the cytotoxicity test, most genera except for Rhodotorula sp and Moesziomyces sp showed cytotoxicity in HaCaT cells. Conclusions: The distribution of mold in the indoor air in multi-use facilities in South Korea differs from region to region, and this is an indicator that should be considered in future health impact studies. In addition, as a result of culturing about 20 types of bacteria dominant in indoor air, it was found that most (90%) inhibit the growth of skin cells, which can be harmful to health. An in-depth study of the health effects of floating fungi is needed.

실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가 (Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air)

  • 백성옥;문영훈
    • 분석과학
    • /
    • 제17권6호
    • /
    • pp.496-513
    • /
    • 2004
  • 본 연구는 환경 대기 중 독성 VOC 측정을 위하여 흡착제를 이용한 시료채취와 열탈착을 병용한 GC/MSD 분석방법론 전반을 총괄적으로 평가하고, 나아가 각종 흡착제의 VOC 시료채취 특성을 비교 평가하기 위하여 수행하였다. 측정대상물질은 BTEX와 유기염소계 화합물을 포함하는 총 33개의 VOC를 선정하였으며, 조사된 흡착제는 상용중인 10종을 대상으로 하였다. 이들 흡착제는 총 6종의 탄소계 (Carbotrap, Carbopack B, Carbotrap C, Carbosieve-SIII, Carboxene 1000 및 Activated Charcoal)와 4종의 고분자 수지계 (Tenax TA, Porapak Q, Chromosorb 102, Chromosorb 106) 로 구분되어 진다. 시료채취과정은 단일 흡착관과 다중흡착관을 대상으로 표준시료와 실제 현장시료를 대상으로 재현성과 감응계수 측면에서 평가하였으며, 측정 정확성은 Carbotrap을 기준으로 평가하였다. 실험결과, 독성 VOC에 가장 적합한 흡착제로는 Carbotrap과 Carbopack B 및 Tenax TA 인 것으로 나타났으며, 강한 흡착제는 열탈착 성능이 떨어지고, 시료 중 수분의 영향으로 감도와 재현성이 현저히 떨어지는 문제점으로 인하여 적합하지 않은 것으로 나타났다. 3 종류의 이중흡착관과 2 종류의 삼중흡착관의 시료채취특성을 평가한 결과, Carbotrap C와 Carbotarp으로 조합된 경우가 가장 우수한 것으로 나타났다. 반면, 친수성인 강한 흡착제가 같이 충전된 삼중 흡착관의 사용은 수분의 영향을 최소화하는데 매우 세심한 주의가 필요한 것으로 나타났다. 결과적으로 흡착시료채취법을 이용하여 실내외 환경에서의 독성 VOC 농도에 대한 신뢰성 있는 자료를 얻기 위해서는 적절한 흡착제의 선정 (혹은 조합) 및 그에 따른 최적 분석 조건의 설정에 무엇보다도 세심한 주의가 요망된다.

일부 실내공간에서 PM10과 CO2의 농도 특성에 관한 연구 (A Study on the PM10 and CO2 Concentrations at Public Places)

  • 정준식;박덕신;김종범;송혜숙;박형규
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4335-4347
    • /
    • 2015
  • 본 연구에서는 2008년 8월부터 2012년 12월 까지 경기도 수원, 안산, 화성 등 초등학교 286곳을 대상으로 교실에서의 $PM_{10}$$CO_2$ 농도 현황을 조사하고, 환경적 특성을 파악하여 초등학교 학생들의 건강에 영향을 미치는 학교 실내공기질의 관리 방안으로 활용하고자 한다. 초등학교를 지역별로 구분하여 $PM_{10}$ 농도를 조사한 결과, 통계적으로 유의한 차이를 보이진 않았다. 그러나 지리적 특성에 따라 상대적으로 공단지역에서는 높은 농도를 보였으며, 농촌지역에서는 낮은 농도를 보였다. $CO_2$ 농도는 각 지역 간 농도 차이는 없는 것으로 나타났다. 연도별 $PM_{10}$ 농도를 분석한 결과, 수원은 2008년, 화성은 2009년에 가장 높은 농도로 나타났다(p<0.01). 안산지역은 2009년에 가장 높은 농도를 보였으나, 유의한 차이를 보이지 않았다. 각 지역 의 연도별 $CO_2$의 농도를 분석한 결과, 유의한 차이를 보이지 않는 것으로 분석 되었다(p-value = 0.366, 0.730, 0.210). 2008년 가을부터 2012년 겨울까지 $PM_{10}$$CO_2$의 계절별 시계열 분석 결과, $PM_{10}$의 경우는 2009년에 높게 나타났으며, 점차적으로 감소하는 경향을 보이다가 2012년에 다시 높아지는 경향을 보였다. $CO_2$는 연도별로 차이가 없는 것으로 나타났으나, 계절별로 는 봄과 겨울기간이 여름철보다 농도가 높아지는 경향을 나타내었다. $PM_{10}$$CO_2$, 건축년도, 학급 평균 인원, 온도, 습도와의 상관성을 분석한 결과, $CO_2$와 환경적 요인인 온도, 습도와 상관성은 각 -0.329, -0.188로 유의한 음의 상관성을 보였다(p< 0.01).

천연가스 수중연소기(SMV)에서 순산소연소를 활용한 $CO_2$ 회수방안 (The $CO_2$ Recovering Recipe used Oxy Combustion with the Submerged Natural Gas Burner)

  • 손화승;김호연;하종만;김준석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.157-157
    • /
    • 2010
  • 우리나라는 기후변화협약에 대응하기 위한 교토의정서를 비준한 국가로서, 아직 온실가스의 의무감축 대상 국가는 아니다. 그러나 2012년부터 시작될 교토의정서 2차 공약기간 중에 브라질, 중국 및 인도와 같이 2차 의무감축대상이 가장 유력시 되는 국가로 지목되고 있으므로, 이러한 변화에 능동적으로 대처할 수 있는 기술적, 사회적, 정책적 방안이 신속히 마련될 필요가 있다. CCS(carbon capture & storage)란 화석연료로 부터 연소시 대기 중으로 배출되는 온실가스($CO_2$)를 포집하여 재생 또는 지중, 해양에 저장하는 기술로서 국가녹색성장 핵심기술중의 하나로 분류되며, 대료적인 $CO_2$ 발생대상인 석탄화력발전소로 부터 $CO_2$ 회수방안, 회수, 처리관련 연구를 포함하여 국내외 적으로 활발한 연구가 이루어 지고 있다. 순산소 연소기술을 통한 $CO_2$ 회수, 처리기술은 연료(천연가스, 석탄, 석유)의 산화제를 공기대신 순도 95% 이상의 고농도 산소를 이용하여 순산소연소를 하며, 이때 발생하는 배가스의 대부분은 $CO_2$와 수증기로 구성되어 있다. 발생된 배가스의 약 70~80%를 다시 연소실로 재순환시켜 연소기의 열적 특성에 적절한 연소가 가능하도록 최적화함과 동시에 배가스의 $CO_2$ 농도를 80% 이상으로 농축시켜 회수를 용이하게 하며, 특히 공해물질은 NOx 발생량을 10ppM 이하로 줄일 수 있다. 천연가스가 생산되는 LNG기지에서 LNG를 기화시키기 위하여 해수식 기화기(ORV : Open Rack Vaporizer와 수중연소식 기화기(SMV ; Submerged Combustion Vaporizer)를 사용하고 있으며, 특히 SMV는 버너를 이용하여 $-162^{\circ}C$ LNG를 $10^{\circ}C$의 LN로 기화시키는 설비로서 이때 연소시 $CO_2$를 상당량 발생시킨다. 본 논문에서는 SMV에서 순산소 연소방식을 적용하여 연료인 천연가스를 연소시키고, 이때 발생되는 $CO_2$와 수분이 주 성분인 배가스를 연소기에 재순환시켜, 연소실내 고온문제를 해결하며, 최종적으로 배가스중 $CO_2$$-162^{\circ}C$의 LNG 냉열을 이용하여 고순도의 액체 $CO_2$로 액화시키므로서 $CO_2$의 회수, 처리문제를 해결하는 방식을 소개하고자 한다. 이러한 방식은 천연가스에서 발생되는 $CO_2$ 회수를 LNG 냉열을 활용하므로서 폐열을 활용하는 에너지 효율적인 문제와 사용가능한 고순도 $CO_2$로 회수하므로서 환경적인 문제를 처리하는 기술이라 할 수 있다.

  • PDF

무기계 침투제를 적용한 콘크리트의 장기폭로실험을 통한 염해 내구성 평가 (Durability Evaluation of Inorganic-Impregnated Concrete Exposed to Long-Term Chloride Exposure Test)

  • 권성준;박상순;노병철
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.283-290
    • /
    • 2008
  • 표면 침투제를 이용한 보수기법은 열화된 콘크리트구조물에 대해서 효과적이므로, 최근들어 많은 연구가 수행되고 있다. 특히 무기계 표면 보호재를 제조할 경우나 현장에서 적용할 경우, 공기오염이 없으므로 환경친화적이며, 침투층과 구콘크리트간의 물리적 성능 차이에 의한 박리가 발생하지 않는다. 침투된 콘크리트의 내구성 평가를 위해서는 장기폭로실험에 의한 평가가 매우 중요하지만, 대부분의 내구성 실험이 일시적이고 정성적인 실내실험에 국한되어 있다. 본 연구에서는 무기계 및 유/무기계 침투제를 사용한 콘크리트 시편에 대하여 장기염해폭로실험을 수행하여 내구적 특성을 실험적으로 평가하였다. 21 MPa과 34MPa로 제조된 2가지의 콘크리트 배합에 대하여, 2년간 해수중, 조석대, 비말대에 노출하였으며, 압축강도, 염화물 침투깊이, 철근부식 자연전위 등을 평가하였다. 평가 결과, 침투제를 적용한 시편은 강도 증가에서는 성능 개선 효과가 거의 없었으나, 염화물 침투깊이와 자연전위에 대해서는 내구성능이 개선된 것으로 평가되었다. 유/무기계 침투제 보다 무기계 침투제에서 염해저항성이 크게 평가되었으며 수중부, 조석대에 노출된 시편보다는 비말대에 노출된 시편에서 염해저항성이 높게 평가되었다.

냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구 (A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types)

  • 이강배;박성호;이희원;이승재;이승현
    • 한국융합학회논문지
    • /
    • 제12권8호
    • /
    • pp.31-37
    • /
    • 2021
  • 산업의 발전으로 도시화로 인해 건물의 규모가 커지면서, 건물의 공기 정화 및 쾌적한 실내 환경을 유지의 필요성 또한 증가하고 있다. 냉동 시스템의 모니터링 기술의 발전으로 건물 내에 발생하는 전력 소모량을 관리할 수 있게 되었다. 특히 상업용 건물에서 발생하는 전력 소모량 중 약 40%가 냉동 시스템에서 일어난다. 따라서 본 연구 냉동시스템 고장진단 알고리즘을 개발하기 위해서 냉동시스템의 구조를 이해하고, 냉동 시스템의 운영과정에서 발생하는 데이터를 수집 분석하여 다양한 유형과 심각도를 가지는 고장 상황을 조기에 신속하게 탐지 분류하고자 하였다. 특히 분류가 어려운 고장 유형들의 분류 정확도를 향상시키기 위하여 3단계 진단 및 분류 알고리즘을 개발하여 제안하였다. 다수의 실험과 초모수 (hyper parameter) 최적화 과정을 거쳐 각 단계에 적합한 분류 모형으로 SVM과 LGBM에 기반 한 모형을 제시하였다. 본 연구에서는 고장에 영향을 미치는 특성을 최대한 보존하면서, 선행연구에서 어려움을 겪었던 냉매 관련 고장을 포함한 모든 고장 유형을 우수한 결과로 도출하였다.