• Title/Summary/Keyword: 신호 획득

Search Result 1,348, Processing Time 0.031 seconds

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Signal Change of Normal Saline by Oxygen Injection in FLAIR Image (산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 2019
  • It was reported that there were some cases in which signal was not inhibited but high signal appeared in cerebrospinal fluid on FLAIR(fluid attenuated inversion recovery) of MRI(Magnetic Resonance Imaging) in case a person inhales high-concentration oxygen. This study was to prepare basic database. We produced a phantom fixed with agar gel and by using it, obtained the images of the signals of normal saline into which oxygen was injected and normal saline diluted with contrast media by changing the TI(Inversion Time) of FLAIR technique and analyzed them. In the result of FLAIR technique of MRI using Philips Achieva MR 3.0T in Busan P Hospital, the SNR(Signal to Noise Ratio) of normal saline into which oxygen was injected was higher than the SNR of normal saline into which oxygen was not injected. However, it was not higher than the SNR of normal saline diluted with contrast media. In the TI 1,800ms, we could obtain the images which do not have the rise of the signal due to oxygen. In the CNR(Contrast to Noise Ratio) of normal saline into which oxygen was injected and normal saline diluted with contrast media as well, it was higher in the TI 1,800ms than in the TI 2,800ms that is mainly used clinically. It is thought that the result of this study could be basic database for studies on change of signal of cerebrospinal fluid as a result of injection of oxygen in FLAIR technique of MRI.

Development of an EMG-based Wireless and Wearable Computer Interlace (근전도기반의 무선 착용형 컴퓨터 인터페이스 개발)

  • Han, Hyo-Nyoung;Choi, Chang-Mok;Lee, Yun-Joo;Ha, Sung-Do;Kim, Jung
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.240-244
    • /
    • 2008
  • This paper presents an EMG-based wireless and wearable computer interface. The wearable device contains 4 channel EMG sensors and is able to acquire EMG signals using signal processing. Obtained signals are transmitted to a host computer through wireless communication. EMG signals induced by the volitional movements are acquired from four sites in the lower limb to extract a user's intention and six classes of wrist movements are discriminated by employing an artificial neural network (ANN). This interface could provide an aid to the limb disabled to directly access to computers and network environments without conventional computer interface such as a keyboard and a mouse.

  • PDF

Heartbeat-signal Monitoring System Using Fine-pressure Sensor (미압 센서를 이용한 심박신호 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1266-1271
    • /
    • 2010
  • In this paper, we implemented a heartbeat-signal monitoring system that can measure and check the heartbeat of a human body in any time and anywhere. The implemented prototype is composed of heartbeat measurement terminal, gateway, and server that collect and process data. The terminal compose sensor network using ZigBee protocol. And server acquire heartbeat signal through differentiating collected data two times, and store above data to database and manage it. We can understand the status of examinee's heart without restriction and self-awareness. Through experiment, we confirmed the possibility of ubiquitous healthcare system based on sonsor network using the ZigBee.

Development of Plasma Monitoring System for Laser Welding Quality Analysis (레이저 용접품질 해석용 플라즈마 감시장치 개발)

  • 권장우;권오상;장영건;이경돈;홍승홍
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.425-431
    • /
    • 1999
  • We develope plasma monitoring system which detect plasma signals and store them for Laser welding quality evaluation and analysis using photo detector. The most fundamental and important aspects in such a system are signal restoration fidelity, noise immunity and noise cancelation capability. In this paper, we propose implementation method using distribute processing structure and hybrid digital communication for high noise cancelation capability, immunity and signal fidelity which are poorly presented in other researches. Lab experimental results and welding experimental results show a effectiveness of proposed method and plasma data is stored with 256 kbps without any communication error. we are implementing various welding defect recognition algorithm in this system.

  • PDF

A Method to Improve Location Estimation of Sensor Node (센서노드 위치 측정 정확도 향상 방법)

  • Han, Hyeun-Jin;Kwon, Tae-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1491-1497
    • /
    • 2009
  • Existing methods to measure are based on ToA (Timer of Arrival), RSS (Received Signal Strength), AoA(Angle of Arrival) and other methods. In this paper, we propose a compensation of ToA and RSS methods to measure more precisely the distance of nodes. The comparison experiments with the traditional ToA method show that the average error value of proposed method is reduced 30%. We believe that this proposal can improve location estimation of sensor nodes in wireless sensor networks.

Analysis of Posture Balance System of using Multi-parameter after Exercising (운동 후 멀티파라미터를 이용한 자세균형의 시스템 분석)

  • Kim, Jeong-Lae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.145-150
    • /
    • 2011
  • This study was developed the posture balance system of multi-parameter for moving body after and before exercising. Body transition meaned a head moving and upper body moving. This system has catched a signal for physical condition of body data such as a data acquisition system, data signal processing and feedback system. There were checked a parameter that measured vision, vestibular, somatosensory, CNS. This system was evaluated a data through the stability. The posture balance system can be used to support assessment for body moving in exercising situation. It was expected to monitor a physical parameter for health management system.

Design and Implementation of the Magnetic Detection System Using the Geological Magnetic Filter (자기환경필터를 이용한 자기표적 검출 시스템의 설계 및 제작)

  • Kim, Won-Ho;Choi, In-Kyu;Park, Jong-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.148-153
    • /
    • 1999
  • In this paper, we developed and implemented the geological magnetic filter for the improvements of the signal to noise ratio of the magnetic detection system. Using the geological magnetic filter, we can remove the coherent noises in the time domain and improve the signal to noise ratio of the magnetic detection system. Numerical simulation results show that geological magnetic filter can excellently remove the sensor misalignment effects and the regular short range local noise as well as it delete the coherent noises. We confirmed that the geological magnetic filter improved the signal to noise ratio about 19dB and deleted the coherent noises with restoring the source magnetic signal through experiments by implemented system.

  • PDF

Characteristics of Bottom Scatter ing from Inhomogeneous Bottom Layer (해저퇴적층의 비균질성에 따른 음파 산란 특성)

  • KIM HYUNGWOO;CHOI JEE WOONG;NA JUNGYUL;SUK DONGWOO;PARK KYUNGJU;PARK KILSUNG;YOON KWANGSEOB;NA YOUNG NAM
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.89-92
    • /
    • 2000
  • 고주파 대역의 소오나를 이용하여 해저면 상태, 즉 해저면 거칠기 및 비균질성의 변화에 따른 음파 산란 영향을 파악하기 위한 실험을 실시하였다. 지음향 요소 중, 평균 입도 크기(mean grain size)는 입도 분석을 통하여 결정하였으며, 이를 기초로 하여 나머지 요소들(Density, Velocity Ratio 등)을 결정하였다. 또한 공극률을 측정하여 평균 입도 크기와 비교함으로써, 공극률과 입자 크기 사이의 관계를 나타내보고자 하였다. 이렇게 파악된 해저면 특성들과 해저면에 의해 산란되어 들어오는 신호의 분석을 통하여 해저면의 상태에 따른 신호의 변화를 비교하였다. 획득된 자료들은 해저면의 상태, 즉 해저면 연흔(ripple)의 유무와 해저면내의 비균질성에 따라 수신되는 신호에 차이를 나타내었으며, 또한 입사각, 산란 각 및 방위각의 변화에 따라 신호에 차이를 보였다. 수신된 신호들간의 비교를 통하여 해저면내의 비균질성의 차이에 따른 산란 음파의 변화 양상을 파악하고자 하였다.

  • PDF

Irregular Sound Detection using the K-means Algorithm (K-means 알고리듬을 이용한 비정상 사운드 검출)

  • Chong Ui-pil;Lee Jae-yeal;Cho Sang-jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.1
    • /
    • pp.23-26
    • /
    • 2005
  • This paper describes the algorithm for deciding the status of the operating machines in the power plants. It is very important to decide whether the status of the operating machines is good or not in the industry to protect the accidents of machines and improve the operation efficiency of the plants. There are two steps to analyze the status of the running machines. First, we extract the features from the input original data. Second, we classify those features into normal/abnormal condition of the machines using the wavelet transform and the input RMS vector through the K-means algorithm. In this paper we developed the algorithm to detect the fault operation using the K-means method from the sound of the operating machines.

  • PDF