• Title/Summary/Keyword: 신호 대 잡음 비율

Search Result 42, Processing Time 0.037 seconds

Study on Power Allocation for Heterogeneous Networks Based on Asynchronous TDD (비동기식 TDD 기반의 이종 네트워크를 위한 전력 할당 방식 연구)

  • Min, Kyungsik;Kim, Taehyoung;Park, Sangjoon;Choi, Sooyong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.10
    • /
    • pp.664-673
    • /
    • 2014
  • This paper analyzes the power allocation scheme to maximize the sum-rate for heterogeneous networks based on asynchronous time division duplex. We consider heterogeneous networks where a small cell exists in the macro cell coverage and the small cell and the macro cell share the same time-frequency resources. We formulate the optimization problem which maximizes the sum-rate of the heterogeneous network subject to the target signal-to-interference-plus-noise ratio. We analyze the feasible region in order for the optimal solution to exists and the optimal power allocation scheme for maximizing the sum-rate. Simulation results show that the proposed power allocation schemes outperform the maximum power transmission scheme.

Performace Analysis on Nodes' Moving distances in Mobile Sensor Field (이동 센서 환경에서 노드 이동 거리에 따른 성능 변화 연구)

  • Park, Se-Young;Yun, Dai Yeol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.505-507
    • /
    • 2021
  • In a Wireless Sensor Network (WSN), the wireless data transmission environment plays an important role in system performance. In the proposed mobility model moving distance of sensor nodes has a great influences on communication performance. Transmission/receiving distance (d), path loss (L), sensitivity, Bit Error Rate (BER), Signal-to-Noise Ratio (SNR) are considerations when designing a wireless communication system. MANET is a form of network in which only wireless terminals communicate with each other independently and move without any assistance of an existing infrastructure network. This paper is research on the optimized power usage method which is study on the effect of the moving distance of mobile nodes on the overall energy efficiency of the system in WSN. The purpose of this study is to extend the life of the entire network by proposing the mobile distance of sensor nodes within the communication available range.

  • PDF

Performance Evaluation of U-net Deep Learning Model for Noise Reduction according to Various Hyper Parameters in Lung CT Images (폐 CT 영상에서의 노이즈 감소를 위한 U-net 딥러닝 모델의 다양한 학습 파라미터 적용에 따른 성능 평가)

  • Min-Gwan Lee;Chanrok Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.709-715
    • /
    • 2023
  • In this study, the performance evaluation of image quality for noise reduction was implemented using the U-net deep learning architecture in computed tomography (CT) images. In order to generate input data, the Gaussian noise was applied to ground truth (GT) data, and datasets were consisted of 8:1:1 ratio of train, validation, and test sets among 1300 CT images. The Adagrad, Adam, and AdamW were used as optimizer function, and 10, 50 and 100 times for number of epochs were applied. In addition, learning rates of 0.01, 0.001, and 0.0001 were applied using the U-net deep learning model to compare the output image quality. To analyze the quantitative values, the peak signal to noise ratio (PSNR) and coefficient of variation (COV) were calculated. Based on the results, deep learning model was useful for noise reduction. We suggested that optimized hyper parameters for noise reduction in CT images were AdamW optimizer function, 100 times number of epochs and 0.0001 learning rates.

A Convergence Study on effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb (하지동맥 전산화단층촬영 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 융복합 효용성 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.431-437
    • /
    • 2015
  • This convergence study analyzed the effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb. 48 patients of 125 cc contrast agent and 30 patients of the same amount divided at a ratio of 7:3 for the contrast agent and normal saline solution were studied. The average attenuation coefficient(HU) and signal to noise ratio(SNR) of abdominal aorta, femoral artery, popliteal artery and posterior tibial artery at each image were evaluated quantitatively and the four criteria in the five point scale was conducted qualitatively by two radiologists and four radiological technologists. In the quantitative evaluation, both HU and SNR had high average score before dilation but there were no statistical significance by independent t-test(p>0.05). In the qualitative evaluation, there were a little differences in the average scores between 4.86~4.77 of original contrast agent and 4.83~4.67 of dilated contrast agent but there were no statistical significance(p>0.05). In the computed tomography of arteries of lower limb, the dilated contrast agent doesn't influence image quality and reduces overall contrast agent and lowers iodine content per unit of molecular therefore will contribute to decrease side effect of contrast agent.

Transmission Probability of Car-to-Car Message Delivery Link based on Visible Light Communications (광무선통신기술을 이용한 차량간 메시지전달링크의 링크전송확률 분석)

  • Kang, Moon-Soo;Lee, Chung-Ghiu
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.6
    • /
    • pp.752-758
    • /
    • 2011
  • In this paper, we perform a research on a message delivery link based on visible light communication using illumination light-emitting diodes (LEDs) for car-to-car communications and the link transmission success probability is analyzed for the link. The message delivery system is modeled and the signal-to-noise ratio is calculated from the received optical power. Then, the link transmission probability is estimated from the calculated bit error rates (BERs). The message delivery system has optical links from an LED transmitter near the rear lamp of a car ahead to a receiver near the headlamp of a car behind, whose positions are assumed to follow the normal Gaussian distribution. The link transmission success probability is calculated considering the physical characteristics of the optical link. The car positions are generated according to the normal distribution and the bit error rates are calculated for all links. The link transmission success probability is defined. For the unoptimized optical car-to-car message delivery links, it is shown that the link transmission success probability is larger than 0.9 with the transmitted optical power of 400 mW and the semi-angle at half power of 30 degree.

A Hippocampus Segmentation in Brain MR Images using Level-Set Method (레벨 셋 방법을 이용한 뇌 MR 영상에서 해마영역 분할)

  • Lee, Young-Seung;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.9
    • /
    • pp.1075-1085
    • /
    • 2012
  • In clinical research using medical images, the image segmentation is one of the most important processes. Especially, the hippocampal atrophy is helpful for the clinical Alzheimer diagnosis as a specific marker of the progress of Alzheimer. In order to measure hippocampus volume exactly, segmentation of the hippocampus is essential. However, the hippocampus has some features like relatively low contrast, low signal-to-noise ratio, discreted boundary in MRI images, and these features make it difficult to segment hippocampus. To solve this problem, firstly, We selected region of interest from an experiment image, subtracted a original image from the negative image of the original image, enhanced contrast, and applied anisotropic diffusion filtering and gaussian filtering as preprocessing. Finally, We performed an image segmentation using two level set methods. Through a variety of approaches for the validation of proposed hippocampus segmentation method, We confirmed that our proposed method improved the rate and accuracy of the segmentation. Consequently, the proposed method is suitable for segmentation of the area which has similar features with the hippocampus. We believe that our method has great potential if successfully combined with other research findings.

Design of a Low-Power 8-bit 1-MS/s CMOS Asynchronous SAR ADC for Sensor Node Applications (센서 노드 응용을 위한 저전력 8비트 1MS/s CMOS 비동기 축차근사형 ADC 설계)

  • Jihun Son;Minseok Kim;Jimin Cheon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.454-464
    • /
    • 2023
  • This paper proposes a low-power 8-bit asynchronous SAR ADC with a sampling rate of 1 MS/s for sensor node applications. The ADC uses bootstrapped switches to improve linearity and applies a VCM-based CDAC switching technique to reduce the power consumption and area of the DAC. Conventional synchronous SAR ADCs that operate in synchronization with an external clock suffer from high power consumption due to the use of a clock faster than the sampling rate, which can be overcome by using an asynchronous SAR ADC structure that handles internal comparisons in an asynchronous manner. In addition, the SAR logic is designed using dynamic logic circuits to reduce the large digital power consumption that occurs in low resolution ADC designs. The proposed ADC was simulated in a 180-nm CMOS process, and at a 1.8 V supply voltage and a sampling rate of 1 MS/s, it consumed 46.06 𝜇W of power, achieved an SNDR of 49.76 dB and an ENOB of 7.9738 bits, and obtained a FoM of 183.2 fJ/conv-step. The simulated DNL and INL are +0.186/-0.157 LSB and +0.111/-0.169 LSB.

Performance Test of the Iterative Method and Newly Developed True X Method (PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가)

  • Choi, Jae-Min;NamKung, Chang-Kyeong;Park, Seung-Yong;Nam, Ki-Pyo;Lim, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • Objective: In this study, the differences between two reconstruction methods were analyzed by comparing image uniformity and contrast according to Iteration and Subset, which were altered through the Iterative method and True X method, used in Siemens' PET/CT studies. Methods: The Phantom images were obtained by exposure for two minutes per one bed. To determine the image uniformity, the Coefficient of variance was used. Also, in order to compare the contrast value, we measured and analyzed the ratio of the SUV mean of Phantom image's hot spheres and the background. Results: Under the same reconstruction conditions (Iteration and Subset) of CV, the Iterative method was higher than the True X method. In the comparison of the SUV mean ratio of the background and hot sphere, the True X method had a closer rate than the Iterative method. Conclusion: The newly developed True X reconstruction method is better than the previously used Iterative method in terms of uniformity and contrast. However, the date for this study was only obtained using the Phantom device. In order to obtain more accurate and useful information from the experiment, further research should be conducted. Also, it is necessary to find the appropriate standards for Iteration and Subset for further experimentation.

  • PDF

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

Application of Dynamic Reaction Cell - Inductively Coupled Plasma Mass Spectrometry for the Determination of Calcium by Isotope Dilution Method (반응셀 유도결합플라스마 질량분석분석기를 이용한 칼슘 동위원소비율의 측정과 동위원소희석법의 적용)

  • Suh, Jungkee;Yim, Yonghyeon;Hwang, Euijin;Lee, Sanghak
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.417-426
    • /
    • 2002
  • Inductively Coupled Plasma Dynamic Reaction Cell Quadrupole Mass Spectrometry (ICP-DRC-QMS) was characterized for the detection of the six naturally occurring calcium isotopes. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise ratio. This experiment shows that the potentially interfering ions such as $Ar^+$, ${CO_2}^+$, ${NO_2}^+$, $CNO^+$ at the calcium masses m/z 40, 42, 43, 44 and 48 were removed by flowing $NH_3$ gas at the rate of 0.7 mL/min $NH_3$ as reactive cell gas in the DRC with a RPq value (rejection parameter) of 0.6. The limits of detection for $^{40}Ca$, $^{42}Ca$, $^{43}Ca$, $^{44}Ca$, and $^{48}Ca$ were 1, 29, 169, 34, and 15 pg/mL, respectively. This method was applied to the determination of calcium in synthetic food digest samples (CCQM-P13) provided by LGC for international comparison. The isotope dilution method was used for the determination of calcium in the samples. The uncertainty evaluation was performed according to the ISO/GUM and EURACHEM guidelines. The determined mean concentration and its expanded uncertainty of calcium was ($66.4{\pm}1.2$) mg/kg. In order to assess our method, two reference samples, Riverine Water reference sample (NRCC SLRS-3) and Trace Elements in Water reference sample (NIST SRM 1643d), were analyzed.