• Title/Summary/Keyword: 신호원 위치

Search Result 353, Processing Time 0.025 seconds

Motion Artifacts reduction from the PPG based on the Improved PMAF for the U-Healthcare System (U-헬스케어 시스템을 위한 개선된 PMAF 기반의 PPG 신호의 동잡음 제거)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Jun, Jae-Chul;Lee, Gun-Ki
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.28-34
    • /
    • 2008
  • The real-time biomedical signal monitoring is a very important factor to realize the ubiquitous healthcare environment. Most of these devices for monitoring the biomedical information get the PPG signal from the user, and these signals are utilized for monitoring their health. It is inconvenient to get the PPG because the user should wear the finger probe with his finger for measuring the PPG signal. Also it is difficult to get the PPG correctly, because of the motion artifacts from the movement of the user. In this paper, we develop the watch type biomedical signal monitoring system without the finger probe, and propose the new algorithm for reducing the motion artifacts from the PPG signal. We designed the system which gets the PPG from the sensor on the wrist band strip. As compared with the finger probe type, this system we proposed is more affected by the motion artifacts. So to filter this motion artifacts, we propose the new method; the improved PMAF(Periodic Moving Average Filter) method.

A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing (명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구)

  • Hwang, Su Jung;Jung, Yoon Won;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2018
  • The purpose of this study is for fundamental research of meditation smart wear for physical and mental healing, and researching method for monitoring phase of meditation through textile by measuring the number of abdominal respiration when meditating. For this purpose, the research implemented Single Wall Carbon Nano-Tube (SWCNT) based strain gauges type textile sensor, considered reliability and validity of respiratory sensing, and analyzed efficiency of respiratory sensing based on body parts comparatively. The first preliminary experiment was to evaluate the performance of textile sensor through abdominal model dummy which open and shut of 5 cm repeatedly for 2 minutes at the rate of 0.1Hz in order to simulate abdominal respiration. It concluded signal efficiency between reference sensor(BIOPAC) and textile respiratory sensor appears statistically significant (p<0.001). The second experiment were conducted with 4 subjects doing abdominal respiration under same conditions, and after comparing the signal values between two sensors from 4 attached locations(around center and sides of omphali and phren), center of omphali and sides of phren were selected as suitable location for measuring meditational breathing as they showed large and stable signals. In result, this research aimed for implementing of the textile sensor for sensing meditational breathing of long respiration cycle, review of reliability and validity for sensing number of meditational respiration with the sensor and consideration of sensing efficiency by sensing location on body parts.

Measurement and Validation of Infrared Signature from Exhaust Plume of a Micro-Turbo Engine (마이크로 터보 엔진 배기 플룸에서의 적외선 신호 측정 및 검증)

  • Gu, Bonchan;Baek, Seung Wook;Jegal, Hyunwook;Choi, Seongman;Kim, Won Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1054-1061
    • /
    • 2016
  • Development of an accurate infrared signature (IR) measurement system is expected to contribute in the development of low observable technology and the spectroscopic analysis of electromagnetic radiation. Application of a spectroradiometer (SR) allows for the measurement of detailed infrared signature from the exhaust plume due to its own heat source. Establishment of a measurement system using a micro-turbo engine is intended to simulate the modelling of the aircraft plume. The engine was installed on a test stand to measure the engine performance. The IR signature was measured by placing the SR perpendicular to the axis line of the exhaust plume. Reference data from the blackbody were also measured to calibrate the raw data, and the infrared signature of the background was also measured for comparison with that of the plume. The calibrated spectral radiance was obtained through the data reduction process and the results were analyzed in specific bands. The experiments revealed that the measurement system established here showed sufficient performance for further comprehensive analysis.

Bubble-type Motion Detector Using a Pulsed-mode Oscillator and Delay Line (펄스 모드 발진기와 지연선로를 이용한 버블형 동작감지기)

  • Lee, Ik-Hwan;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.342-348
    • /
    • 2015
  • This paper presents a new motion detector that has a bubble-layer detection zone using a pulsed-mode oscillator and delay line. The proposed motion detector controls the bubble-layer detection zone with pulse width of transmitted signals and creates IF signals only by reflected signals from the target within the detection zone whose position is determined by time delay of the delay line. The fabricated motion detector uses the pulsed-mode voltage controlled oscillator as a signal source which has a center frequency of 8 GHz, pulse width of 2 nsec and pulse period of 30 nsec. It successfully makes the bubble-layer detection zones at 1 m, 3 m and 5 m distant from itself using two delay lines with 7 nsec and 12 nsec delay, and is also demonstrated to detect the target within the detection zones.

Analysis and Measurement of Interferences between UWB and Mobile Communication System (UWB 시스템과 이동통신 시스템간의 간섭측정 분석)

  • Kim Myung-Jong;Lee Hyung-Soo;Hong Ic-Pyo;Shin Yong-Sup
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.10 s.89
    • /
    • pp.1011-1017
    • /
    • 2004
  • Ultra Wideband(UWB) technologies have been developed to exploit a new spectrum resource in substances and to realize ultra-high-speed communication, high precision geolocation, and other applications. The energy of UWB signal is extremely spread from near DC to a few GHz. This means that the interference between conventional narrowband systems and UWB systems is inevitable. However, the interference effects had not previously been studied from UWB wireless systems to conventional mobile wireless systems sharing the frequency bands such as Korean Cellular CDMA and WCDMA. This paper experimentally evaluates the interference from two kinds of UWB sources, namely a direct-sequence spread-spectrum CDMA(DS-CDMA) UWB source and an impulse radio UWB source, to a Cellular CDMA and WCDMA digital transmission system. The average frame error rate degradation of each system are presented. From these experimental results, the interference effects of DS-CDMA UWB source is not severe compared to the Impulse UWB.

Safety Distance Visualization Tool for LTE-Based UAV Positioning in Urban Areas (도심 지역 LTE 측위 기반 무인항공기 안전거리 생성 알고리즘 연구 및 시각화 도구 개발)

  • Lee, Halim;Kang, Taewon;Seo, Jiwon
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.408-414
    • /
    • 2019
  • We developed a surveillance tool for collision avoidance of unmanned aerial vehicles (UAVs) in urban areas. In our tool, users can visualize the safety distance on the actual 3D map of urban area. The estimated positions of UAVs are assumed to be obtained based on the long-term evolution (LTE) signals. The safety distance is defined to include two or more signals with bias. The safety distance calculation method used in this paper enables simulation similar to the actual urban areas where signals are frequently biased due to multipath. In the simulation, the parameters were set based on the measured values, and the change of the safety distance according to the number of faulty signals was simulated. As a result, increasing the number of faulty signals led to a longer safety distance as expected.

Performance Evaluation for ECG Signal Prediction Using Digital IIR Filter and Deep Learning (디지털 IIR Filter와 Deep Learning을 이용한 ECG 신호 예측을 위한 성능 평가)

  • Uei-Joong Yoon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.611-616
    • /
    • 2023
  • ECG(electrocardiogram) is a test used to measure the rate and regularity of heartbeats, as well as the size and position of the chambers, the presence of any damage to the heart, and the cause of all heart diseases can be found. Because the ECG signal obtained using the ECG-KIT includes noise in the ECG signal, noise must be removed from the ECG signal to apply to the deep learning. In this paper, the noise of the ECG signal was removed using the digital IIR Butterworth low-pass filter. When the performance evaluation of the three activation functions, sigmoid(), ReLU(), and tanh() functions, was compared using the deep learning model of LSTM, it was confirmed that the activation function with the smallest error was the tanh() function. Also, When the performance evaluation and elapsed time were compared for LSTM and GRU models, it was confirmed that the GRU model was superior to the LSTM model.

Predicton and Elapsed time of ECG Signal Using Digital FIR Filter and Deep Learning (디지털 FIR 필터와 Deep Learning을 이용한 ECG 신호 예측 및 경과시간)

  • Uei-Joong Yoon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.563-568
    • /
    • 2023
  • ECG(electrocardiogram) is used to measure the rate and regularity of heartbeats, as well as the size and position of the chambers, the presence of any damage to the heart, and the cause of all heart diseases can be found. Because the ECG signal obtained using the ECG-KIT includes noise in the ECG signal, noise must be removed from the ECG signal to apply to the deep learning. In this paper, Noise included in the ECG signal was removed by using a lowpass filter of the Digital FIR Hamming window function. When the performance evaluation of the three activation functions, sigmoid(), ReLU(), and tanh() functions, which was confirmed that the activation function with the smallest error was the tanh() function, the elapsed time was longer when the batch size was small than large. Also, it was confirmed that result of the performance evaluation for the GRU model was superior to that of the LSTM model.

Implementaion of Home Healthcare System for a Patient using SAW Tag (SAW 태그를 이용한 재택환자 종합관리시스템 구현)

  • Song, Jai-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.183-188
    • /
    • 2017
  • This paper is for the a study on home healthcare system for a patient using SAW Tag. This system is useful when there's a patient in home. Many patients are wounded in restroom. But restroom is very private place and nobody want to be disturbed here. The place where the patient is most injured in the house is the toilet, and it is the point where the privacy of the individual should be kept and the patient's condition should be checked and cope with in case of emergency. And using saw tag, we can calculate position and ID through reflected rf signal. Therefore we propose a general home healthcare system. The management system utilized a seat bed system to monitor at-home patients. The system mounts a bio-signal measuring unit on a toilet seat, measures a bio-signal from the bio-signal measuring unit, and the measured bio-signal is transmitted to the main server through the user's smart phone. With proposed system, we can expand operation area to silver town where many patients are cared. In this paper we developed sensor system and saw tag positioning system and showed the result.

The effectiveness of MRI evaluation after anterior cruciate ligament reconstruction using hamstring tendon autograft (자가 슬괵건을 이용한 전방십자인대 재건술 후 결과 판정에 있어 MRI 검사의 유용성)

  • Kim, Jin-Goo;Kim, Young-Woo;Lee, Soo-Won;Shim, Jae-Chan;Oh, Soo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • Purpose: To evaluate the effectiveness of MRI after ACL reconstruction with femoral tunnel at 10 o'clock position. Materials and Methods: MRI findings of 29 patients after ACL reconstruction using hamstring tendon autograft were evaluated. The mean period from operation to MRI was 18.9 months($7{\sim}40$ months). Signal intensity, morphology and continuity of graft, femoral insertion, graft angle, roof impingement, cross pin breakage and position were evaluated. Those findings were compared with KT-2000, Lysholm knee score and pivot shift test. Results: There was no significant correlation between signal intensity of graft and the duration to MRI. Most common pattern of the morphology was straight, and the continuity was well-preserved. 13 cases of femoral tunnel insertion were zone 4 and 16 were zone 3. There were no roof impingement. 10 cases showed cross pin breakages, of which 5 were found at the outside of distal femoral posterior cortex. 9 showed cross pin directed posteriorly in axial view. There was no significant correlation between clinical results and cross pin breakage. Conclusion: MRI examinations after ACL reconstructions are useful to evaluate the graft status, position of the graft and cross pins. Since the direction of the cross pin is important especially in 10 o'clock femoral position, care should be taken to avoid cross pin breakage.

  • PDF