• Title/Summary/Keyword: 신호변환장치

Search Result 258, Processing Time 0.027 seconds

Development of depression diagnosis system using EEG signal (뇌파 측정 신호를 이용한 우울증 진단장치 개발)

  • Kim, Kyu-Sung;Jung, Ju-Hyeon;Lee, Woo-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.452-458
    • /
    • 2017
  • In this study, a device was developed for diagnosing depression using EEG signals from July 2016 to June 2017. For normal people, the left alpha rhythm is more activated than the right alpha rhythm, but for the depressed patients, the right alpha rhythm is more activated than the left one. An analog circuit and digital low pass filter were used for noise removal and amplification of EEG, and the Hamming window function was applied to eliminate the signal leakage generated by the fast Fourier transform. To verify the validity of the developed diagnosis system, the EEG of 20 university students in the 3rd and 4th grade with an average age of 24 years was measured. Calculations of the relative value of the left and right alpha rhythm for the depression diagnosis revealed a minimum, maximum, and mean value of 66.7, 113.3, and 92.2, respectively. In addition, 7 out of 20 subjects were between 90 and 95, and those with a higher mean deviation of approximately 20 tended to have mild depression. These results can provide meaningful data for the development of depression treatment equipment by solving the left and right brain asymmetry problem, and it may be applied usefully to diagnose depression after clinical trials on a large number of depressed patients.

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF

Real-Time LDR to HDR Conversion Hardware Implementation using Luminance Distribution (영상의 휘도 분포를 이용한 LDR 영상의 실시간 HDR 변환 하드웨어 구현)

  • Lee, Seung-min;Kang, Bong-soon
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.901-906
    • /
    • 2018
  • Due to the development of display technologies for images, the resolution and quality of images are increasing day by day. In accordance with the development of the display technology, researches have been actively conducted on technologies for converting and displaying existing images to higher resolution and quality. Since the results of theses studies are included in the image signal processor, hardware implementation is indispensable. In this paper, we propose a real-time HDR(High Dynamic Range) conversion hardware implementation of LDR(Low Dynamic Range) image using luminance distribution. The proposed method extracts the features of the image using the histogram of the luminance distribution, and extends the luminance and color based on the extracted features. In addition, when the proposed method is designed by hardware IP(Intellectual Property) and its performance is verified, 4K DCI(Digital Cinema Image) can be handled at a rate of 30fps at 265.46MHz.

A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room (병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구)

  • Hwang, L.H.;Na, S.K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.360-369
    • /
    • 2008
  • The solar cells should be operated at the maximum power point because its output characteristics were greatly fluctuated on the variation of insolation, temperature and load. It is necessary to install an inverter among electric power converts by means of the output power of solar cell is DC. The inverter is operated supply a sinusoidal current and voltage to the load and the interactive utility line. In this paper, the proposes a photovoltaic system is designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper is operated in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature for solar cell has typical dropping character. The single phase PWM voltage source inverter is consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be develop continuously by connecting with the source of electric power for ordinary using. It can be cause the efect of saving electric power, from 10 to 20%. The single phase PWM voltage source inverter operates in situation, that its output voltage is in same phase with the utility voltage. The inverter are supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

Motor Imagery Brain Signal Analysis for EEG-based Mouse Control (뇌전도 기반 마우스 제어를 위한 동작 상상 뇌 신호 분석)

  • Lee, Kyeong-Yeon;Lee, Tae-Hoon;Lee, Sang-Yoon
    • Korean Journal of Cognitive Science
    • /
    • v.21 no.2
    • /
    • pp.309-338
    • /
    • 2010
  • In this paper, we studied the brain-computer interface (BCI). BCIs help severely disabled people to control external devices by analyzing their brain signals evoked from motor imageries. The findings in the field of neurophysiology revealed that the power of $\beta$(14-26 Hz) and $\mu$(8-12 Hz) rhythms decreases or increases in synchrony of the underlying neuronal populations in the sensorymotor cortex when people imagine the movement of their body parts. These are called Event-Related Desynchronization / Synchronization (ERD/ERS), respectively. We implemented a BCI-based mouse interface system which enabled subjects to control a computer mouse cursor into four different directions (e.g., up, down, left, and right) by analyzing brain signal patterns online. Tongue, foot, left-hand, and right-hand motor imageries were utilized to stimulate a human brain. We used a non-invasive EEG which records brain's spontaneous electrical activity over a short period of time by placing electrodes on the scalp. Because of the nature of the EEG signals, i.e., low amplitude and vulnerability to artifacts and noise, it is hard to analyze and classify brain signals measured by EEG directly. In order to overcome these obstacles, we applied statistical machine-learning techniques. We could achieve high performance in the classification of four motor imageries by employing Common Spatial Pattern (CSP) and Linear Discriminant Analysis (LDA) which transformed input EEG signals into a new coordinate system making the variances among different motor imagery signals maximized for easy classification. From the inspection of the topographies of the results, we could also confirm ERD/ERS appeared at different brain areas for different motor imageries showing the correspondence with the anatomical and neurophysiological knowledge.

  • PDF

A Performance Comparison of CCA and RMMA Algorithm for Blind Adaptive Equalization (블라인드 적응 등화를 위한 CCA와 RMMA 알고리즘의 성능 비교)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • This paper related with the performance comparison of CCA and RMMA blind adaptive equalization in order to reduce the intersymbol interference which is occurred in channel when transmitting the 16-QAM signal, high spectrum efficiencies of nonconstant modulus characteristic. The CCA possible to improve the misadustment and initial convergence by compacting the every signal constellation of 16 by using the sliced symbol of the decision device output, namely statistical symbol, but incresing the computational cost. The RMMA possible to minimize the fast convergence speed and misadjustment and channel tracking capability without increasing the computational cost by obtain the error signal after transform to 4 constant modulus signal based on the region of signal constellation located. In this paper, these algorithm were implemented in the same channel, and the blind adaptive equalization performance were compared using the equalizer output signal constellation, residual isi, MSE, SER. As a result of simulation, the RMMA has better performance in output signal constellation, residual isi and MSE compared to the CCA, but has slow convergence speed about 1.3 times. And the SER performance presenting the robustness to the noise signal, the CCA has more beeter in less SNR, but the RMMA has better in greater than 6dB in SNR.

The Conducting Motion Recognizing System Using Acceleration Sensors for the Virtual Orchestra (가속도 센서를 이용한 지휘 동작 인식 시스템)

  • Son, Dong-Kwan;Lee, Hui-Sung;Noh, Young-Hae;Wohn, Kwang-Yun;Goo, Bon-Cheol
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.124-129
    • /
    • 2006
  • 음악은 소리를 즐긴다는 뜻을 담고 있다. 감상자에게 단순한 청각적 자극을 넘어 즐거움을 주기 위해선 음악적인 경험이 뒷받침되어야 한다. 가상 현실을 이용한 사용자와 시스템 간의 상호작용을 음악 경험 제공에 접목하려는 시도는, 새로운 경험을 통해 일반인들이 보다 쉽게 음악을 접하고 체험함으로써 음악을 통해 즐거움을 얻을 수 있도록 도움을 주는 데에 그 목적이 있다. 가상 오케스트라를 구현하고 지휘 동작을 재현하는 것은 이러한 가능성을 극대화하는 연구이다. 본 논문에서는 가상 오케스트라를 구현하기 위해 필수적인 중간 단계로, 사용자의 지휘 동작을 감지하여 연주의 박자(속도)를 제어하는 지휘 시뮬레이션 시스템을 제시한다. 실제의 지휘 동작을 분석하고, 동작의 변화를 인식하기 위하여 가속도 센서를 이용, 공간상에서 지휘봉의 움직임을 가속도 정보로 수집하여 이에 상응하는 박자의 제어를 구현한다. 사용자의 박자 명시에 따라 변화하는 상하 방향의 가속도를 센서를 통해 전압 신호로 입력 받고, DSP 의 A/D conversion 모듈에서 디지털 신호로 변환, 일정 수준 이상의 신호를 박자 정보로 직렬통신을 통해 컴퓨터에 전달한다. 컴퓨터에서는 Max/MSP를 이용하여 각 박자 사이의 시간 간격을 측정하고 상응하는 MIDI 음악을 재생하는 방식으로 시스템이 구현된다. 기존 연구에서 사용된 CCD 카메라에 의한 Motion Tracking 을 보완하여 동작의 크기에 따라 음량을 조절한다. 본 논문에서 제시되는 시스템은 지휘 동작에서 가장 특징적으로 나타나는 상하 방향의 급격한 가속도 변화를 직접 입력 받기 때문에 기존 시스템에 비해 지휘 동작의 인식 성공률을 높일 수 있으며, 화상 처리 및 계산에 의한 지연을 최소화할 수 있다. 또한, 장치의 규모를 소형화하여 보다 지휘봉의 형태에 가까운 인터페이스를 제공하며, 적합한 응용 콘텐츠를 접목할 경우 게임 컨트롤러로의 발전 가능성이 있다.

  • PDF

Design and Manufacture of FMCW Radar with Multi-Frequency Bandwidths (다중 대역폭을 갖는 FMCW 레이다 송수신기 설계 및 제작)

  • Hwang, Ji-hwan;Kim, Seung Hee;Kang, Ki-mook;Kim, Duk-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.4
    • /
    • pp.377-387
    • /
    • 2016
  • Design of X-band frequency FMCW based imaging radar with multi-resolutions and performances of the self-manufactured radar system are presented in this study. In order to implement the multi-bandwidths, a ramp sequence of the FMCW signal is consisting of two kinds of 'saw-tooth' waveform with different bandwidth, and a receiver circuit consisting of L-band source and frequency converter circuit is used to effectively extract spectra of beat-frequency from the received signal of X-band frequency. The system setups for performance measurement of self-manufactured radar system are maximum output power of 35 dBm, sampling frequency of 1.2 MHz and sweep time of 1 ms. Then, the measured resolutions of the modulated signal having bandwidth of 500 MHz and 300 MHz in range & azimuth-direction are (0.28 m, 0.26 m) and (0.44 m, 0.27 m), respectively.

Replacement Condition Detection of Railway Point Machines Using Data Cube and SVM (데이터 큐브 모델과 SVM을 이용한 철도 선로전환기의 교체시기 탐지)

  • Choi, Yongju;Oh, Jeeyoung;Park, Daihee;Chung, Yongwha;Kim, Hee-Young
    • Smart Media Journal
    • /
    • v.6 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Railway point machines act as actuators that provide different routes to trains by driving switchblades from the current position to the opposite one. Since point failure caused by the aging effect can significantly affect railway operations with potentially disastrous consequences, replacement detection of point machine at an appropriate time is critical. In this paper, we propose a replacement condition detection method of point machine in railway condition monitoring systems using electrical current signals, after analyzing and relabeling domestic in-field replacement data by means of OLAP(On-Line Analytical Processing) operations in the multidimensional data cube into "does-not-need-to-be replaced" and "needs-to-be-replaced" data. The system enables extracting suitable feature vectors from the incoming electrical current signals by DWT(Discrete Wavelet Transform) with reduced feature dimensions using PCA(Principal Components Analysis), and employs SVM(Support Vector Machine) for the real-time replacement detection of point machine. Experimental results with in-field replacement data including points anomalies show that the system could detect the replacement conditions of railway point machines with accuracy exceeding 98%.

Development of Photoacoustic System for Breast Cancer Detection (유방암 진단용 광음향 영상 시스템 개발)

  • Lee, Soonhyouk;Ji, Yun-Seo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.183-190
    • /
    • 2013
  • Recently, the photoacoustic imaging system has been widely and intensively developed, and has been shown the possibility of diagnosis for early stage cancer. In this study, we developed a photoacoustic tomography imaging system with a commercial ultra sound device and a linear array probe. A tube phantom and a chicken breast phantom was made for the possibility of a system as a breast cancer detection. A moving average filter and a band pass filter with 3~6 MHz bandwidth were developed for background noise elimination before delay-and-sum beamforming algorithm was used for image reconstruction. As a result, we showed that some signal processing procedure before beamforming was effective for the photoacoustic image reconstruction.