• Title/Summary/Keyword: 신호계측

Search Result 655, Processing Time 0.024 seconds

Design and fabrication of a 300A class general-purpose current sensor (300A급 일반 산업용 전류센서의 설계 및 제작)

  • Park, Ju-Gyeong;Cha, Guee-Soo;Ku, Myung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current sensors are used widely in the fields of current control, monitoring, and measuring. They have become more popular with the increasing demand for smart grids in a power network, generation of renewable energy, electric cars, and hybrid cars. Although open loop Hall effect current sensors have merits, such as low cost, small size, and weight, they have low accuracy. This paper describes the design and fabrication of a 300A open loop current sensor that has high accuracy and temperature performance. The core of the current sensor was calculated numerically and the signal conditioning circuits were designed using circuit analysis software. The characteristics of the manufactured open loop current sensor of 300 A class was measured at currents up to 300 A. According to the test of the current sensor, the accuracy error and linearity error were 0.75% and 0.19%, respectively. When the temperature compensation was carried out with the relevant circuit, the temperature coefficients were less than $0.012%/^{\circ}C$ at temperatures between $-25^{\circ}C$ and $85^{\circ}C$.

Safety factor simulation of the transplanter bevel gear by planting condition (주간거리에 따른 정식기 베벨기어의 안전율 시뮬레이션)

  • Kim, Du Han;Choi, Chang Hyun;Jang, Hyeon Jun;Kim, Yong Joo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.15-15
    • /
    • 2017
  • 본 연구는 필드 작업 시 작업조건에 따른 정식기의 PTO 부하를 측정하고, 이를 이용하여 작업조건에 따른 안전율 시뮬레이션을 목적으로 수행하였다. 부하 계측 시스템은 PTO 축의 부하를 측정하기 위한 토크 센서, 토크 센서에서 발생한 신호를 수집하기 위한 데이터 수집장치, 노트북에 전원을 공급하기 위한 파워 컨트롤러로 구성하였다. 토크센서에서 입력된 부하 데이터를 처리하기 위한 소프트웨어는 Labview(Version 2011, National Instrument, USA)를 사용하였다. 포장시험은 유사한 토양 조건에서 4회 반복 시험을 수행하였으며, 작업속도 고속 조건에서 4개의 주간거리(26, 35, 43, 80cm)와 3개의 식부깊이 (85, 105, 136mm)에 대하여 수행하였다. 안전율 시뮬레이션을 위한 소프트웨어는 KISSsoft(Version 2016, Kissling & Co. AG, Switzerland)를 사용하였다. 식부깊이 85mm에서 주간거리 26, 35, 43, 80cm일 때 작업시 각각 굽힘 안전율은 2.2874, 2.4507, 2.7139, 2.8064로 나타났으며 접촉 안전율은 1.1787, 1.2799, 1.3205, 1.3275로 나타났다. 식부깊이 105mm에서 주간거리 26, 35, 43, 80cm일 때 작업 시 각각 굽힘 안전율은 2.1261, 2.2781, 2.4879, 2.5866로 나타났으며 접촉 안전율은 1.1296, 1.1425, 1.2710, 1.2507로 나타났다. 식부깊이 136mm에서 주간거리 26, 35, 43, 80cm일 때 작업 시 각각 굽힘 안전율은 1.6587, 1.6651, 1.7824, 2.2198로 나타났으며 접촉 안전율은 1.0030, 1.0104, 1.0450, 1.1931로 나타났다. 주간거리에 따른 식부깊이의 굽힘 안전율과 접촉 안전율은 가장 차이가 큰 주간거리 80cm에서 식부깊이가 85, 105, 136mm일 때 작업 시 각각 굽힘 안전율은 2.8064, 2.5866, 2.2198로 나타났으며 접촉 안전율은 1.3275, 1.2507, 1.1931로 나타났다. 시뮬레이션 결과 정식기 베벨기어의 안전율은 주간거리가 짧을수록, 식부깊이가 깊을수록 더 낮게 나타났다. 그러므로 정식 작업 시 정식기의 부하와 내구성을 고려하여 적절한 작업조건을 선정해야 함을 알 수 있다. 또한 향후 다양한 토양 조건 및 작업 단수 등에 따른 포장시험을 추가로 진행하여 여러 조건에서의 안전율 시뮬레이션을 수행할 예정이다.

  • PDF

Effect of human biosignal according as foot was heating with hot water (발 부분 온수 열자극시 인체 현상에 미치는 영향)

  • Lee, Woo-Cheol;Min, Kyeug-Kee;SaKong, Sug-Chin
    • 전자공학회논문지 IE
    • /
    • v.43 no.1
    • /
    • pp.5-15
    • /
    • 2006
  • In this paper, we measured the biosignal using hot-water system(STYX ford202) on foot. The biosignal transition data is observed from hot-water thermotherapy on foot. pre and post demonstration conditions under 43$^{\circ}C$ and 45$^{\circ}C$ are checked about 9 physiological factors for 10 persons and 10 days. (Checking Time: pre-test, post-test(5, 10, 15, 20 minutes)). The biosignal transition of demonstration's results showed as belows; Forehead Temperature($^{\circ}C$): -0.69 $\pm$ 0.01 dec, Leg Temperature($^{\circ}C$): 1.51 $\pm$ 0.22 inc, Blood Flow($m\ell/min$): 1.18 $\pm$ 0.50 inc, Blood Pressure(mmHg): (max) -1.49$\pm$ 2.81, (min) -0.06 $\pm$ 0.13 dec, Heart Rate(bpm): 6.97 $\pm$ 0.72 inc, Blood Sugar($mg/d\ell$) : -2.41 $\pm$ 1.55 dec, Oxygen Saturation(%): 1.34 $\pm$ 0.28 inc, Body Fat(%) -1.75 $\pm$ 0.15 dec, Weight(kg): -0.10 $\pm$ 0.04 dec. (dec: decrease, inc: increase)

Effects of the Excitation Level on the Dynamic Characteristics of Electrical Cabinets of Nuclear Power Plants (진동수준이 원자력발전소 전기 캐비닛의 동특성에 미치는 영향)

  • Cho, Sung-Gook;Kim, Doo-Kie;Go, Sung-Hyuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.23-30
    • /
    • 2010
  • Seismic qualification (SQ) is required prior to the installation of safety related electrical cabinets in nuclear power plants (NPPs). Modal identification of the electrical equipment is one of the most significant steps to perform SQ, and is an essential process to construct a realistic analytical model. In this study, shaking table tests were conducted to identify a variation of the dynamic characteristics of a seismic monitoring system cabinet installed in NPPs according to the excitation level. Modal identification of the cabinet has been performed by a frequency domain decomposition method. The results of this study show that the dynamic properties of the cabinet are nonlinearly varied according to the excitation level and the specimen behaves significantly in a nonlinear manner under safe shutdown earthquake motion in Korea. The main sources of the nonlinear behavior of the specimen have been judged by friction forces and geometrical nonlinearity rather than material nonlinearity. The nonlinear variation of the dynamic characteristics of the electrical cabinet might be accepted as an important fact that should be considered during the SQ of safety related equipment.

A Study on Applicability of Embedded Smart Sensor for Concrete Curing Monitoring (콘크리트 양생 강도 모니터링을 위한 매립형 지능형 센서의 적용성 연구)

  • Park, Seung-Hee;Kim, Dong-Jin;Hong, Seok-Inn;Lee, Chang-Gil
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.219-224
    • /
    • 2011
  • In this study, a piezoelectric smart sensor that can be embedded inside of concrete structures is developed to investigate the early stage of concrete curing. A waterproof coating is used to protect the piezoelectric sensor from moistures of concrete mixture. Also, a mortar case is utilized to encapsulate the sensor to protect it from impact loads. To estimate the strength of concrete, a self-sense guided-wave actuated sensing technique is applied. In the guided wave, its velocity is varied according to the mechanical properties of concrete such as modulus of elasticity. Because modulus of elasticity directly affects the strength of concrete, the guidedwave's velocity also affects the concrete strength development. To verify the feasibility of using the proposed approach, the smart sensor was embedded into a 100MPa concrete cylinder and the self-sense guided wave is continuously measured throughout the curing process. The measurements showed that the propagation time (TOF) of the measured guided waves gradually decreased as the curing age increased. Especially, at the early age of the curing process, the variation of the TOF was very significant. Furthermore, the results showed that there is a linear relationship between the TOF of the self-sense guided waves and the strength of concrete existed. It is safe to conclude that the proposed approach can be used very effectively in monitoring of the strength development of high strength concrete structures.

Brain Atrophy and White Matter Lesions on Magnetic Resonance Imaging in Alzheimer's Disease (알쯔하이머 치매 환자의 뇌자기공명영상(腦磁氣共鳴影像)에 나타난 뇌위축(腦萎縮)과 뇌백질병변(腦白質病變)에 대한 연구)

  • Woo, Jong Inn;Kim, Ju Han
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.203-210
    • /
    • 1996
  • Objects : To investigate the relationship between the age of onset with the atrophy and the white matter hyperintensities observed in the brain MRI of Alzheimer patients. Methods : The authors measured volumetrically cortical and ventricular brain atrophy and rated semiquantitatively white matter signal hyperintensities in nine presenile and 18 senile Alzheimer patients, who were matched for dementia severity, according to NINCDS-ADRDA criteria and in age-matched 10 presenile and 11 senile control subjects. Results : Presenile Alzheimer patients showed significantly greater cortical and ventricular atrophy indices(p<0.05) but no difference in white matter hyperintensity scores compared to the age-matched control group. On the contrary, senile Alzheimer patients showed significantly greater white matter hyperintensity scores(p<0.05) but no difference in cortical and ventricular atrophy indices compared to the age-matched control group. Conclusion : An earlier onset was related to marked brain atrophy with less white matter lesions and a later onset is related to marked white matter lesions with less brain atrophy in Alzheimer's disease. Our results suggested the passible difference in the pathophysiology between the presenile and the senile-onset Alzheimer's disease.

  • PDF

Development of Android-Based Photogrammetric Unmanned Aerial Vehicle System (안드로이드 기반 무인항공 사진측량 시스템 개발)

  • Park, Jinwoo;Shin, Dongyoon;Choi, Chuluong;Jeong, Hohyun
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.3
    • /
    • pp.215-226
    • /
    • 2015
  • Normally, aero photography using UAV uses about 430 MHz bandwidth radio frequency (RF) modem and navigates and remotely controls through the connection between UAV and ground control system. When using the exhausting method, it has communication range of 1-2 km with frequent cross line and since wireless communication sends information using radio wave as a carrier, it has 10 mW of signal strength limitation which gave restraints on life my distance communication. The purpose of research is to use communication technologies such as long-term evolution (LTE) of smart camera, Bluetooth, Wi-Fi and other communication modules and cameras that can transfer data to design and develop automatic shooting system that acquires images to UAV at the necessary locations. We conclude that the android based UAV filming and communication module system can not only film images with just one smart camera but also connects UAV system and ground control system together and also able to obtain real-time 3D location information and 3D position information using UAV system, GPS, a gyroscope, an accelerometer, and magnetic measuring sensor which will allow us to use real-time position of the UAV and correction work through aerial triangulation.

Holocene Sea Level Changes in the Eastern Yellow Sea: A Brief Review using Proxy Records and Measurement Data (황해 동부 연안의 홀로세 해수면 변화: 대리기록과 관측자료를 통한 재검토)

  • Lee, Eunil;Chang, Tae Soo
    • Journal of the Korean earth science society
    • /
    • v.36 no.6
    • /
    • pp.520-532
    • /
    • 2015
  • In order to understand the Holocene sea level changes in the eastern Yellow Sea, the west coast of Korea, and to compare the rates of sea level rise in each period of time, the geological proxy records for pre-instrumental era and measurement data for the present day were combined and analysed. The sea level in the Yellow Sea rose fast with a rate of about 10 mm/yr during the early Holocene, and decelerated down to 1 mm/yr since the mid to late Holocene. The rising rates of sea level in the 20th century were slightly higher than those in the late Holocene. The present-day rates of sea level rise, known as the 'rapid' rise, are in fact much lower or similar, compared to the early to mid Holocene sea levels in the study area. Recent tide-gauge data show that sea level rise in the eastern Yellow Sea has been accelerating toward the 21st century. These rising trends coincide well with global rising patterns in sea level. Additionally, the present-day rising trends of sea level in this study are correlated with increased rates of carbon dioxide concentrations and sea surface temperatures, further indicating a signal to global warming associated with the human effect. Thus, the sea level changes induced by current global warming observed in the eastern Yellow Sea and world's oceans can be considered as 'Anthropocene' sea level changes. The changes in sea level are based on instrumental measurements such as tide-gauges and satellite altimetry, meaning the instrumental era. The Holocene changes in sea level can thus be reconstructed from geological proxy records, whereas the Anthropocene sea-level changes can be solely based on instrumental measurements.

Extraction and Complement of Hexagonal Borders in Corneal Endothelial Cell Images (각막 내피 세포 영상내 육각형 경계의 검출과 보완법)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.102-112
    • /
    • 2013
  • In this paper, two step processing method of contour extraction and complement which contain hexagonal shape for low contrast and noisy images is proposed. This method is based on the combination of Laplacian-Gaussian filter and an idea of filters which are dependent on the shape. At the first step, an algorithm which has six masks as its extractors to extract the hexagonal edges especially in the corners is used. Here, two tricorn filters are used to detect the tricorn joints of hexagons and other four masks are used to enhance the line segments of hexagonal edges. As a natural image, a corneal endothelial cell image which usually has regular hexagonal form is selected. The edge extraction of hexagonal shapes in corneal endothelial cell is important for clinical diagnosis. The proposed algorithm and other conventional methods are applied to noisy hexagonal images to evaluate each efficiency. As a result, this proposed algorithm shows a robustness against noises and better detection ability in the aspects of the output signal to noise ratio, the edge coincidence ratio and the extraction accuracy factor as compared with other conventional methods. At the second step, the lacking part of the thinned image by an energy minimum algorithm is complemented, and then the area and distribution of cells which give necessary information for medical diagnosis are computed.

High Energy Electron Dosimetry by Alanine/ESR Spectroscopy (Alanine/ESR Spectroscopy에 의한 고에너지 전자선의 선량측정)

  • Chu, Sung-Sil
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 1989
  • Dosimerty based on electron spin resonance (ESR) analysis of radiation induced free radicals in amino acids is relevant to biological dosimetry applications. Alanine detectors are without walls and are tissue equivalent. Therefore, alanine ESR dosimetry looks promising for use in the therapy level. The dose range of the alanine/ESR dosimetry system can be extended down to 1 Gy. In water phantom the absorbed dose of electrons generated by a medical linear accelerator of different initial energies $(6\~21MeV)$ and therapeutic dose levels (1~60 Gy) was measured. Furthermore, depth dose measurements carried out with alanine dosimeters were compared with ionization chamber measurements. As the results, the measured absorbed doses for shallow depth of initial electron energies above 15 MeV were higher by$2\~5\%$ than those calculated by nominal energy $C_E$ factors. This seems to be caused by low energy scattered beams generated from the scattering foil and electron cones of beam projecting device in medical linear accelerator.

  • PDF