• Title/Summary/Keyword: 신호각도

Search Result 317, Processing Time 0.03 seconds

Performance analysis of SNR and BER for radiation pattern reconfigurable antenna (인체 부착용 방사패턴 재구성 안테나의 SNR 및 BER 성능 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4125-4130
    • /
    • 2015
  • This paper presents the communication performance for the radiation pattern reconfigurable antenna in the wearable device measuring bio signal (temperature, blood pressure, pulse etc.) of human body. The operational frequency is 2.4 - 2.5 GHz, which covers Bluetooth communication bandwidth. The maximum gain of the antennas is 1.96 dBi. The proposed antenna is efficiently transmitting and receiving signal by generating two opposite beam directions using two RF switches (PIN diode). Also, we investigated how radiation pattern changes according to three angles ($30^{\circ}$, $90^{\circ}$, $150^{\circ}$) of Top Loading. In this paper, we measured and compared the SNR (Signal-to-Noise Ratio) and BER (Bit Error Rate) performances of the proposed antennas in the condition between an ideal environment of anechoic chamber and smart house existing practical electromagnetic interferences (Universal Software Radio Peripheral, USRP). Throughout the comparing the results of the measurement of two cases, we found that the SNR is degraded over 5dB in average and BER is increased over ten times in maximum, therefore, it is confirmed that the error rate of receiving signal is increased. The measured results of SNR and BER value in this paper able to expect the performance degrading by the interference from the electromagnetic devices.

Characteristics of EMG Median Frequency and Torque During Isometric Back Extension Exercises (등척성 요추 신전운동 시 중앙주파수와 토크의 특성)

  • Kang, S. J.;Park, S. J.;Jang, K.;Park, K. H.;Kwon, O. Y.;Kim, Y. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • Localized muscle fatigue can be identified by a downward shift of the EMG frequency typically represented by a fall in the median frequency The Present experimental study was Performed to investigate the time change of the median frequency and the muscle torque during maximal isometric back extension exercises at different exercise angles (0$^{\circ}$, 12$^{\circ}$, 36$^{\circ}$and 72$^{\circ}$) Twenty heath subjects (mean age : 24.35 $\pm$ 2.70) were Participated in this study Median frequency was extracted from EMG signals by employing the fast Fourier transform. Initial median frequency and the slope of median frequency was not significantly correlated with the muscle torque. Pearson's Product moment correlation was used to quantify the relationship between slopes of median frequency and torque. The results may suggest that the exorcise angle during maximal isometric back extension exercises does not affect the slopes of the median frequency and torque, and y-intercept of the median frequency among exercise angles There was no significant correlation between slopes of median frequency and torque. But there was a moderate correlation between median frequency and torque at each exercise angle. In conclusion, the exercise angle during maximal isometric back extension exercise is not a direct effect on slopes of median frequency and torque. But results showed that the shift of median frequency and torque shift were highly correlated in all subjects.

Optimizing Imaging Conditions in Digital Tomosynthesis for Image-Guided Radiation Therapy (영상유도 방사선 치료를 위한 디지털 단층영상합성법의 촬영조건 최적화에 관한 연구)

  • Youn, Han-Bean;Kim, Jin-Sung;Cho, Min-Kook;Jang, Sun-Young;Song, William Y.;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.281-290
    • /
    • 2010
  • Cone-beam digital tomosynthesis (CBDT) has greatly been paid attention in the image-guided radiation therapy because of its attractive advantages such as low patient dose and less motion artifact. Image quality of tomograms is, however, dependent on the imaging conditions such as the scan angle (${\beta}_{scan}$) and the number of projection views. In this paper, we describe the principle of CBDT based on filtered-backprojection technique and investigate the optimization of imaging conditions. As a system performance, we have defined the figure-of-merit with a combination of signal difference-to-noise ratio, artifact spread function and floating-point operations which determine the computational load of image reconstruction procedures. From the measurements of disc phantom, which mimics an impulse signal and thus their analyses, it is concluded that the image quality of tomograms obtained from CBDT is improved as the scan angle is wider than 60 degrees with a larger step scan angle (${\Delta}{\beta}$). As a rule of thumb, the system performance is dependent on $\sqrt{{\Delta}{\beta}}{\times}{\beta}^{2.5}_{scan}$. If the exact weighting factors could be assigned to each image-quality metric, we would find the better quantitative imaging conditions.

Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality (흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가)

  • Kim, Min Kyoung;Kwak, Hyeng Ju;Kim, Jong Hun;Choe, Won-Ho;Ha, Yun Kyung;Lee, So Jung;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.143-147
    • /
    • 2016
  • Recently, digital tomosynthesis system (DTS) has been developed to reduce overlap using conventional X-ray and to overcome high patient dose problem using computed tomography (CT). The purpose of this study was to develop image reconstruction algorithm and to evaluate image characteristics and dose with chest digital tomosynthesis (CDT) system. Image reconstruction was used for filtered back-projection (FBP) methods and system geometry was constructed ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, and ${\pm}30^{\circ}$ angular range for acquiring phantom images. Image characteristics carried out root mean square error (RMSE) and signal difference-to-noise ratio (SDNR), and dose is evaluated effective dose with ${\pm}20^{\circ}$ angular range. According to the results, the phantom image with slice thickness filter has superb RMSE and SDNR, and effective dose was 0.166 mSv. In conclusion, we demonstrated usefulness of developed CDT image reconstruction algorithm and we constructed CDT basic output data with measuring effective dose.

Joint Angles Analysis of Intelligent upper limb and lower extremities Wheelchair Robot System (지능형 상 · 하지 재활 휠체어 로봇 시스템의 관절각도 분석)

  • Song, Byoung-Ho;Kim, Kwang Jin;Lee, Chang Sun;Lim, Chang Gyoon
    • Journal of Internet Computing and Services
    • /
    • v.14 no.6
    • /
    • pp.33-39
    • /
    • 2013
  • When the eldery with limited mobility and disabled use a wheelchairs to move, it can cause decreased exercise ability like decline muscular strength in upper limb and lower extremities. The disabled people suffers with spinal cord injuries or post stroke hemiplegia are easily exposed to secondary problems due to limited mobility. In this paper, We designed intelligent wheelchair robot system for upper limb and lower extremities exercise/rehabilitation considering the characteristics of these severely disabled person. The system consists of an electric wheelchair, biometrics module for Identification characteristics of users, upper limb and lower extremities rehabilitation. In this paper, describes the design and configurations and of developed robot. Also, In order to verify the system function, conduct performance evaluation targeting non-disabled about risk context analysis with biomedical signal change and upper limb and lower extremities rehabilitation over wheelchair robot move. Consequently, it indicate sufficient tracking performance for rehabilitation as at about 86.7% average accuracy for risk context analysis and upper limb angle of 2.5 and lower extremities angle of 2.3 degrees maximum error range of joint angle.

Robust DNA Watermarking based on Coding DNA Sequence (부호 영역 DNA 시퀀스 기반 강인한 DNA 워터마킹)

  • Lee, Suk-Hwan;Kwon, Seong-Geun;Kwon, Ki-Ryong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.2
    • /
    • pp.123-133
    • /
    • 2012
  • This paper discuss about DNA watermarking using coding DNA sequence (CDS) for the authentication, the privacy protection, or the prevention of illegal copy and mutation of DNA sequence and propose a DNA watermarking scheme with the mutation robustness and the animo acid preservation. The proposed scheme selects a number of codons at the regular singularity in coding regions for the embedding target and embeds the watermark for watermarked codons and original codons to be transcribed to the same amino acids. DNA base sequence is the string of 4 characters, {A,G,C,T} ({A,G,C,U} in RNA). We design the codon coding table suitable to watermarking signal processing and transform the codon sequence to integer numerical sequence by this table and re-transform this sequence to floating numerical sequence of circular angle. A codon consists of a consecutive of three bases and 64 codons are transcribed to one from 20 amino acids. We substitute the angle of selected codon to one among the angle range with the same animo acid, which is determined by the watermark bit and the angle difference of adjacent codons. From in silico experiment by using HEXA and ANG sequences, we verified that the proposed scheme is more robust to silent and missense mutations than the conventional scheme and preserve the amino acids of the watermarked codons.

A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection) (Haas 촬영법에서 선예한 영상 획득을 위한 연구)

  • Ahn, Jun-Ho;Han, Jae-Bok;Song, Jong-Nam;Kim, In-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2022
  • The Study In order to obtain a sharpness Image from Skull PA axial projection (Haas) in a head axial X-ray Examination, this study changed the posture angle using Skull Phantom and evaluated the image subjectively to 5 radiologists who worked in the Department of Imaging at University Hospital. In the prone position, the head was lowered 4 cm from the back of the head, entered 25° toward the head, and the image evaluation score was high with 20 points, such as the back bone, dorsum sellae projected in the large hole, and posterior clinoid process. In addition, the score significance was verified, and the Cronbach Alpha value was evaluated to have good reliability of 0.789. As a result of calculating the signal-to-noise ratio (SNR) by setting the region of interest (ROI) of the image, it was the highest at 5.957 for 25° incident at the back of the head and 6.430 for 30° incident at the back of the head. As a result of the study, in order to obtain a sharp image of the back of the head bone, dorsum sellae, and posterior clinoid process when shooting in the axial direction after the head, it is filmed by tilting 25° toward the head from 4 cm below the back of the head. In order to obtain a sharp image of rock pyramid symmetry, petrous ridge, sagittal suture, and lambdoid suture, it is thought that it will be helpful for clinical use if you shoot it 8cm down from the back of the head and tilt it 30° toward the head.

An analysis of the Sound Radiation Characteristics of the King Song-Dok Bell Using Cylindrical Acoustic Holography (원통형 음향 홀로그라피를 이용한 성덕대왕 신종의 방사음장 특성 분석)

  • Kim, Yang-Hann;Kim, Sea-Moon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.94-100
    • /
    • 1997
  • In order to investigate the radiation of sound from the King Song-Duk bell, we measured the sound pressure around the bell at every 30$^{\circ}$ using a microphone line array which was composed of 30 microphones separated by 15cm;total number of measurement point was 360. The sound field was estimated by using cylindrical acoustic holography. The spectrum of measured sound pressure demonstrates that it is almost like white noise in the very beginning, but in 10 seconds two close frequency components(64.06Hz, 64.38Hz) remain and make a famous beating. This beating sound is often believed to make unique sound of the King Song-Duk bell. The mode shapes of that frequency components are the same except that one is rotated by 45$^{\circ}$ from the other. This phenomenon occurs at the other pairs of components are the same except ones in very high frequency range where the mode shapes are rather complex.

  • PDF

Posture Stabilization Control of QuadCopter Using Sensor Fusion and Modified PID Control (진동에 강인한 센서 융합 필터와 개선된 PID 제어 방식을 이용한 쿼드콥터의 자세 제어)

  • Cho, Youngwan;Kim, Hyun-Soo
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.376-382
    • /
    • 2014
  • In this paper, we propose a advanced attitude PID controller and sensor fusion method robust to the vibration of the quadcopter unmanned air vehicle using four BLDC motors. When the gyro sensor and acceleration sensor are fused, a complementary filter is designed to ignore the vibrations generated by the motors and to complement the drawbacks. As a result, we obtain accurate results than using each sensor. Also, it is possible to obtain a low delay results in robust to vibration than the low-pass filter or moving average filter, which is generally used for quadcopter. And we improved D controller, which have being used for attitude control of quadcopter, to quadcopter using gyro sensor. it was confirmed that the attitude is stabilized and error is reduced By using gyro sensor output instead of variation of estimated angle in D control.

Flap Hinge Moment Estimation through Ground and Flight Tests (지상 및 비행 시험을 통한 플랩의 힌지 모멘트 추정)

  • Ko, Myung-Gyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.464-470
    • /
    • 2018
  • In this paper, a practical method of estimating the flap hinge moments which change according to the aircraft flap operations was introduced. For the flap design, the hinge moment derived by structural load analysis and wind tunnel tests was able to be compared with the real flight hinge moment, and the static safety of the flap structure could be verified though this comparison. In order to perform the tests, two strain gauges were installed on the flap hinge and an onboard device for aircraft load monitoring was utilized. Through the ground test, the correlation between the strain and the moment of the flap hinge was calibrated with analytic and finite element analysis. During the flight test, strain signals together with the flap deflection angles and airspeed were recorded. Finally, the flight hinge moments could be predicted by the measured strain which was calibrated with the analytic and the finite element analysis.