• Title/Summary/Keyword: 신축학교

Search Result 102, Processing Time 0.033 seconds

Hazardous Organic Compounds Concentration of Newly Built School Classroom and Neurobehavioral Performance of Elementary School Children (신축학교 교실 실내공기 중 유해유기물질 농도와 초등학생의 신경행동기능에 관한 연구)

  • Kwaak, Hong-Taak;SaKong, Joon
    • Hwankyungkyoyuk
    • /
    • v.24 no.3
    • /
    • pp.18-25
    • /
    • 2011
  • This study was conducted to evaluate the effects of volatile organic compounds and formaldehyde of newly-built school classroom indoor air on the neurobehavioral functions of students. The elementary schools that were opened in September 2008(as of September 2008) was selected for newly-built school and the elementary school that were opened in March 2006 was selected for control group schools. The concentration of formaldehyde(HCHO), a hazardous organic compound that exists in the air of classrooms, exceeded the standard value of $108.2{\mu}g/m^3$ in newly-built schools while it was $60.8{\mu}g/m^3$ in control group schools, which is around 60% of the standard concentration. However, the concentration of the total volatile organic compounds(TVOCs) was $788.9{\mu}g/m^3$ and $756.1{\mu}g/m^3$ in newly-built schools and control group schools respectively, which are approximately two times higher than the standard concentration. In newly-built schools, the mean reaction time of additions and symbol digit, respectively 3,020ms and 2,398ms in pre-exposure were increased to 3,167ms and 2,514ms respectively in post-exposure. The difference of mean reaction time between pre and post exposure was 146.8 ms, or 4.6%, and 116.7ms, or 4.8%, respectively, showing statistically-significant increase of reaction time(p<0.05). On the contrary, the difference of reaction time of both tests were not statistically significant in the control group schools. These results showed that the neurobehavioral performance of newly-built schools students were affected by volatile organic compounds and formaldehyde of classroom indoor air.

  • PDF

Reduction Effect of VOCs and Formaldehyde Using Auto Bake-Out System (자동 베이크 아웃 시스템을 이용한 휘발성유기화합물 및 포름알데히드 저감효과)

  • Kim, Hyung-Jin;Lee, Kap-Soo;Cho, Jin-Kyu;Lee, Jun-Bum;Roh, Heoung-Rae;Yun, Hong-Su
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.291-295
    • /
    • 2011
  • A bake-out process using auto switchgear for five days was performed to evaluate the reduction effect of the concentration of volatile organic compounds (VOCs) and formaldehyde in a newly-built elementary school gymnasium. Reduction rates of VOCs were observed as followings: 38.2, 64.2, 86.3, 80.2, and 71.5% for benzene, toluene, ethylbenzene, xylene, and styrene, respectively, which satisfies the indoor air quality standards of newly-built apartment houses in Korea. The reduction rate of total VOCs and formaldehyde were 67.0 and 24.7%, respectively. Those results proved that the bake-out process using auto switchgear was effective for reducing indoor air pollutants.

Feasibility Study for the Reconstruction of Jangan Primary School Building (서울 장안초등학교 재건축 계획 설계 연구 요약)

  • Kim, Seung-Je
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.3 no.3
    • /
    • pp.59-70
    • /
    • 1996
  • 장안초등학교는 한국전쟁 이후인 1955년에 개교된 초등학교이다. 처음에는 8학급의 가교사시설에 18학급으로 편성되어 초기부터 시설이 양적으로 부족하였다. 또한 이 지역의 학생수 증가로 거의 매년에 걸쳐 학급수의 증가와 교실증축이 함께 이루어 졌다. 현재 건물의 건립년도를 살펴보면 1965년 6월에 처음 신관 1층 부분이 건설되어 70년대와 80년대에 걸쳐 꾸준히 증축되어 왔으며, 대지 동측의 별관은 1993년 12월에 건설된 새건물로, 학교교사 건물이 30년된 건물과 최근의 건물이 함께 공존하고 있다. 철근콘크리트 건물이 구조적으로는 100년도 견딘다 하지만 실제로는 약 30년이면 콘크리트의 산성화가 가속화되면서 구조적으로 안전하지 못하다는 학설이 인정되어, 최근 30년이 경과된 학교 건축의 재건축이 사회적 문제로 대두되고 있다. 실제로는 25년이상 경과된 건물에서도 구조적인 하자가 발생하는 예 가 많아 교육부에서는 대체로 25년이상 경과된 건물에 대하여 재건축을 실시하고 있다. 장안초등학교는 20년에서 30년 경과된 건물이 많은 부분을 차지하는 관계로 재건축이 실시되는 예이다. 아직까지 사용이 가능하다고 판단되는 건물은 본관의 남측부분의 교사(1983년 증축)과 신관의 우측부분(1985년 9월 23일 증축)과 별관(1993년 12월 14일 신축)교사동을 들수 있다. 때문에 이 부분에 대하여 철거할 것인가 혹은 그대로 사용할 것인가에 대한 의견이 있어, 최종적으로 별관은 그대로 사용하는 것을 원칙으로 하고 본관 남측부분은 가장 마지막 건설시기에 철거하고 신관 우측부분은 규모가 작아 철거하기로 하였다. 학교건축은 다른 일반건물과는 달리 교육이라는 기능을 충분히 발휘할수 있는 공간구성이 필수적이라 할수 있다. 여기서 말하는 교육이란 예전의 주입식 교육이 아니라 21세기를 바라보는 정보화 세계화를 지향하는 교육으로 학생 개개인의 창의성과 자주성을 발휘시킬수 있는 교육이라는 점에 대하여 의견은 없을 것이다. 이러한 교육이란 다양한 교육방법을 전제로 하며 하나의 학년을 하나의 학습그룹으로 생각하는 것은 중요한 출발점이 될 것이다. 한 학년의 그룹을 교대상의 기본으로하여 이러한 그룹에 대하여 일제학습, 그룹학습, 팀티칭, 개별학습이 이루어 질수 있는 공간을 제공하는 점을 본 장안초등학교 기본계획에서 출발점으로 하였다. 물론 학교전체 학생을 콘트롤할 수 있는 교육방법도 존재한다. 선진 외국의 예를 살펴보면 아동의 능력별 교육을 위하여 무학년제(Non-Grade)를 도입하는 경우도 있지만 아직 우리나라에서는 학급단위가 중요시되고 있다. 이 학급단위는 교육단위이면서 생활지도 단위이기도 하다. 이러한 점을 인식하여 학교건축의 간장 기본 단위가 되는 보통교실 계획을 보통교실과 오픈스페이스를 연속시킨 유니트로 계획하여 일제학습, 그룹학습, 팀티칭, 개별학습 등이 이루어 질수 있도록 하였다. 실제로는 36학급을 계획할 경우, 한학년의 6개 학급이 하나의 공통된 공간내에 그룹핑 되는 것이 바람직하지만(제3안의 배치에서 제안하여 보았지만 북측교실, 오픈스페이스의 통로화등의 문제점이 있었다), 그 규모가 너무 커서 3개학급을 하나의 유니트로 하였다. 물론 한학년이 동일한 층에 배치시켜 서로의 관련성을 높게 하였다. 특별교실 계획은 보통교실과의 관련성과 장래 지역개방의 역할을 고려하여 계획하여야 할 것이다. 장안 초등학교의 경우는 별관을 그대로 사용 한다는 조건이 있기 때문에 기존의 편복도 형식의 교실에서는 보통교실 계획의 어려움이 있어 특별 교실동으로 고려하였다. 때문에 지역개방에 대해서는 문제점을 안고 있다. 체육관은 기준령에는 권장시설로 되어 있지만 학교시설에 필수적인 시설이라 생각한다. 체육은 국민건강에 직결되기 때문이다. 또한 체육관 건설은 실외체육 실내체육에 대응할 뿐 아니라 학교 행사등에 유용히 사용되기 때문에 더욱 필요시설이라 할수 있겠다. 또한 지역개방을 위하여 정문 혹은 후문 가까이에 배치시키는 것은 필수적이다. 별관, 체육관, 운동장, 후문측에 12학급용의 단독건물 등의 기본적인 제약조건을 고려하여 배치하자면 자연히 교실동들이 분산되는 결과를 낳게된다. 이러한 각각의 교사동을 A동을 중심으로 구름다리로 연결하여 동선의 불편함을 해소시켰다. 주차장은 후문 가까이에 약 10정도의 주차공간이 확보가능하다. 이외에는 운동장을 사용하는 방법과 체육관의 1층부분을 필로티로 하여 그곳에 20대 정도 주차시키는 방안이 있다. 주차는 많을수록 편리는 하겠지만 제한된 대지에 모두 만족 시켜주기는 불가능하다. 공공용의 주차와 소방에 필요한 동선이 요구된다. 특히 도심주차난을 생각할 때는 차라리 적극적으로 지하주차장을 계획하는 방안이 있을 것이다. 마지막으로 현재 67학급은 초대형 규모로 초등학교 규모로는 적합하지 못하다. 장래를 고려하여 48학급에서 최종적으로 36학급으로 계획하였으나 한동안은 67학급이 그대로 유지될 것으로 보인다. 신설 초등학교가 가까운 시기에 개교될 것을 기대한다.

  • PDF

Interior surface treatment guidelines for classrooms according to the acoustical performance criteria (학교 교실의 음환경 기준에 따른 실내마감 방안)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.92-101
    • /
    • 2016
  • There are many results in which acoustical conditions of a classroom play an important role for studying effects and academic achievement of students. However, there are very few guidelines or design proposals which could make appropriate acoustic environment when classrooms are built or renovated. The present study suggests various design proposals satisfying acoustic standards of classrooms based on theoretical calculation and acoustic field experiments. At first, minimum area of sound absorption was calculated which is required to satisfy the acoustic standard for domestic middle and high schools. Also, room acoustic measurements were carried out in order to investigate the acoustic performance of an existing classroom by changing interior finishing materials on ceiling and rear walls. As a result, it was revealed that reverberation time standard below 0.8 s can be acquired even if there is no sound absorption on ceiling which is a general practice executed in Korea. Specially, it was found that if partial area of ceiling would be treated as reflective with the ratio of sound absorption and reflection as 2:1, almost similar acoustic parameters of $C_{50}$, $D_{50}$, RASTI (Rapid Speech Transmission Index) and higher sound levels could be acquired in comparison with the case of entire sound absorption on ceiling.

A Study on Fire Risk of Multi-family Apartment Houses Constructed with the Exterior of the EIFS (외단열시스템 외장재로 시공된 다세대 공동주택의 화재위험에 관한 연구)

  • Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.60-65
    • /
    • 2013
  • EIFS system has the merit of low construction cost and shortening of construction period by easy-to-construct. For such reasons as mentioned above, it has been using across the board such as residential building, school, officetel, building remodeling and so on. It, however, has a drawback of generating plenty of combustible gases from styrofoam which is main material of it. In this regard, measures to prevent losses of life from combustible gases are needed urgently as fires on residential buildings applied EIFS caused human casualties resulted from combustible gases. With respect to the above, this study will analyze the risk of fires on residential facilities, such as multi-family apartment houses, schools and other buildings, applied EIFS which is the most frequently used as material of exterior wall and suggest countermeasure of it.

천연기념물 제395호 진주 가진리 새발자국과 공룡발자국 화석산지의 새로운 해석

  • Im, Jong-Deok;Gong, Dal-Yong;Kim, Gyeong-Su;Kim, Tae-Hyeong
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.21-21
    • /
    • 2010
  • 천연기념물 제395호 진주 가진리 새발자국과 공룡발자국 화석산지는 1997년 5월 20일, 경남과학교육원 신축 공사장에서 당시 경남과학고등학교 교사로 근무하던 백광석(현재 서상중고등학교 교장)에 의해 최초로 발견되어, 수 백 점의 새발자국 화석과 공룡발자국 화석들이 학계에 알려지게 되었다. 지금까지도 세계 여러나라의 중생대 새 발자국 중에서 가장 밀도가 높은 화석산지로 손꼽히고 있으며 많은 학자들의 관심을 받고 있다. 이곳의 지질은 백악기 하양층군 함안층 하부의 적색 이암 또는 셰일과 사암의 호층으로 구성되어 있고, 새발자국 화석들은 적색 이암에서 발견된다. 현재, 이 화석산지는 경남과학교육원 건물 내부에 위치하고 있으며, '화석문화재전시관'이라는 명칭으로 보호 및 관리되고 있기때문에 자연재해와 풍화에 의한 침식을 1차적으로 막고 있다. 이 화석산지는 우리나라에서는 천연기념물 제394호 해남 우항리 화석산지와 함께 현장을 그대로 보존하면서 화석의 보존과 관리를 동시에 할 수 있는 건물을 지어 자연사교육을 진행할 수 있는 곳으로 많은 학생들을 대상으로 우리나라의 소중한 화석을 직접 관찰하고 학습하는 체험교육이 가능하다. 원격조종카메라 시스템을 활용하여 관람객이 직접 자신이 원하는 발자국 화석을 세부적으로 관찰할 수 있게 장치한 interactive system은 과학교육 효과를 증진시킨다. 선행 연구에 의하면, 본 화석산지에서 익룡의 발자국 화석(KS 071)도 공룡이나 새발자국과 같은 층리면에서 서로 겹쳐서 나타난다고 보고되었으나, 본 연구에 의해 다시 조사된 결과 전형적인 익룡의 발자국 화석에서 보이는 분명한 특징들을 발견할 수 없었다. 물갈퀴를 가진 새발자국 가운데에서 Uhangrichnus chuni 와 Jindongornipes kimi 로 기재된 표본들에 대하여서도 새롭게 분석하였다. Uhangrichnus chuni로 기재된 많은 표본들은 II-IV번 발가락 사이의 각, 물갈퀴의 형태, 뚜렷한 hallux 등의 형태적 특징을 근거로 할 때, 대부분이 Ignotorinis yangi로 판단된다. Jindongornipes kimi로 기재된 표본들은 이미 기재된 표본보다 크기가 적어도 10%-25%가 작으며, II-IV번 발가락 사이의 각에서 차이를 보인다.

  • PDF

A Study on Diversification of Financing Method for BTL Private Participation in Infrastructure by Introduction of ABS (자산유동화증권 도입을 통한 BTL 민간투자사업에서의 재원 조달 다양화 방안 연구)

  • Park, Young-Min;Kim, Soo-Yong
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.378-383
    • /
    • 2006
  • This study presents the results from an investigation into ABS to revitalize small and medium construction enterprises, and to analyze merits and demerits of ABS introduction using sensitivity analysis some realistic cases. According to some available procedures, this study suggests ABS introduction structure of new education facilities construction in BTL projects of two different types. In order to analyze the effectiveness of introduction, a model was built as new education facilities construction in this paper. In addition, this study tried to put a figure on finance interest changes by analyzing changes for earning rates and money that payed by the government. Moreover, this study also presents merits and demerits of ABS introduction.

  • PDF

현상설계경기 - 강원전문대학

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.9 s.329
    • /
    • pp.112-115
    • /
    • 1996
  • 강원전문대학신축설계경기의 당선작이 지난 6월21일 발표되었다. 총 9개의 작품이 응모한 이번 설계경기에서는 주.엄앤드이건축사 사무소(이각표)와 주.종합건축사사무소 산(한광호)의 공동안이 당선작으로 선정되었으며 주.건축사사무소 원.시공.형제(정상원)와, 주,건축사종합건축사사무소(공순구)의 안이 각각 우수작으로 선정되었다. 이 설계경기는 강릉시 주문진의 주문진소속고등학교 4만 8천여평 부지의 기존교사동, 실습동 증축과 대학본관, 도서관 등을 비롯 부대시설을 건립하는 것으로, 한국교육개발원의 '강원전문대설립방안 및 중.장기발전계획연구'에 의거 전문대학의 설립이념 및 목적, 설치학과 및 학생정원, 시설확충계획의 반영, 옥외시설 오픈스페이스 등을 충분히 고려하여야하는 것을 기본 설계방향으로 잡았다. 이번 심사는 한봉기(기획관), 이중근(건설교통국장)과 강원대, 관동대, 삼척산업대, 춘천교육대의 건축 및 조경학과 교수 등 총 10명이 맡았다. 당선된 주.엄앤드이건축사사무소와, 주.종합건축사사무소 산의 공동안은 적절한 조닝캠퍼스 내외의 접근성양호와 보차분리와 토지이용계획의 우수 등 여러 부분에서 심사위원들의 높은 점수를 받았다.

  • PDF

Wearable based Electrocardiogram Sensing Clothes for Monitoring of Vital Signal (생체신호 측정을 위한 웨어러블 기반의 심전도 측정 의복)

  • Yu, Ki-Youp;Han, Ki-Tae;Kim, Ju-Hyun;Kim, Jong-Hun;Chung, Kyung-Yong;Lee, Jung-Hyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.277-278
    • /
    • 2009
  • 차세대 하이테크 스마트 의류는 복합 차원에서의 감성적인 요소를 섬유 패션기술에 IT융합 기술을 이용하여 제공하고 있다. 생체신호를 이용한 감성은 모호하여 정량적이고 객관적인 측정이 어렵고, 그 표현도 제한된 감성 어휘에 의하여 나타나기 때문에 구체적으로 파악하는 것은 어려운 일이다. 이를 위하여 제품의 기능적 측면뿐만 아니라 정서적 감정과 선호도가 반영된 제품의 설계나 디자인 또한 요구되고 있다. 본 논문에서는 생체신호 측정을 위한 웨어러블 기반의 심전도 측정 의복을 제안하였다. 착용자가 평소 자주 입는 티셔츠를 응용하여 답답해하거나 불편하지 않게 제작하고 소매 형태로 신축성있는 소재를 사용한다. 인체의 형태에 따라 의복과 바이오센서의 전극이 안정적으로 밀착될 수 있도록 고탄력 밴드를 이용하여 일자형으로 제작하였다. 심전도 측정 의복을 착용에 의해 수집된 심전도 ECG 파형을 수집하고 심박변화율을 계산하는 시뮬레이션을 개발한다.

Impact of Indoor Air Quality on the Eye Conditions of Occupants in Newly-built University Buildings (새 학교 건물 내 실내공기질이 재실자의 안구에 미치는 영향)

  • Kim, Woo-Jae;Kim, Sun-Duk;Kim, Hyojin;Kim, Ho-Hyun;Lee, Cheol-Min;Kim, Yoon-Shin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: This study was to find out the influence on eyes of indoor air quality in college students taking course, such as Sick-building syndrome symptoms and effects on the eye in new-built university buildings. Methods: We selected a new building in a university located in Metro Seoul and college students in a department for the study. The number of total participants was 33, to whom questionnaire surveys were conducted in advance to check individual traits (gender, age, whether to smoke, whether to wear contact lenses, or whether to drink). The first questionnaire surveys and checking of ocular symptoms to first indoor hazardous materials were conducted in October and two months later the second surveys and checking were carried out in December. The indoor air quality was measured when conducting the first questionnaire surveys and the second questionnaire surveys; especially measurements of gaseous materials such as aldehydes and VOCs in the indoor air were conducted. Results: Indoor air quality of the new building was as follows: formaldehyde level was 22.90 ${\mu}g/m^3$ in the first measurement and 16.79 ${\mu}g/m^3$ in the second measurement. In addition, most materials showed higher value in the first measurement. The level of TVOC was statistically significant (p<0.05) decreased on 448.54 ${\mu}g/m^3$ in the first and 62.55 ${\mu}g/m^3$ in the second. In clinical assessments to check ocular symptoms caused by eye irritations, dry eye syndrome was found in the first and second exposures. When comparing the first and second assessments, dry eyes deteriorated in the morning of the second attempt compared to the first one. Conclusions: In the survey of ocular symptoms and the measurement of indoor air quality, the level of formaldehyde was measured higher in the second attempt than the first; thus, it was confirmed the influence of indoor air quality in a new building upon ocular symptoms of occupants.