• Title/Summary/Keyword: 신속한 화재진압

Search Result 36, Processing Time 0.027 seconds

A Design of Fire Monitoring System Based On Unmaned Helicopter and Sensor Network (무인헬기 및 센서네트워크 기반 화재 감시 시스템 설계)

  • Yun, Dong-Yol;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.2
    • /
    • pp.173-178
    • /
    • 2007
  • Recently, fires happen to occur owing to various factors. However, the demage caused by the fire is eyer increasing because timely actions could not be taken. To reduce the demage, a development of fire detection system which makes it possible to take adequate actions is requited. In this work, a sensor network-based fire detection system which utilizes both sensor nodes equipped with smoke sensor and unmaned helicopter is proposed. The proposed system is composed of unmaned helicopter which can gather the measurement data from the deployed sensor nodes and the embedded system which can get visual information on the firing spot and transmit these images to a remote server computer. The proposed system is applied to actual test bed to verify its feasibility.

A Method on Developing 3D/BIM-Based Real Time Fire Disaster Information Management (3D/BIM 기반 기존 건축물 실시간 건물 화재 정보 관리 방안)

  • Bae, Subin;Cha, Heesung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.2
    • /
    • pp.3-12
    • /
    • 2023
  • Fire accidents in buildings are reported more frequently nowadays. Existing building fire accidents can lead to large-scale accidents as damage to human and physical resources increases over time, so it is necessary to quickly find ways to suppress fires and rescue them. Currently, more attention is being paid to new buildings than the existing buildings. In addition, fire information can not be captured in a real time basis for the buildings. In line with the demands of this technology, this study presents a quick and systematic fire management method to minimize damage caused by fire in buildings. As a way to achieve the purpose of the study, ArduinoTM sensors and ExcelTM and RevitTM-DynamoTM tools have been combined to develop a new fire information management system and develop a real-time 3D visualization model. It is expected to contribute to the real-time smart fire management system by proposing a fire management application as a way to utilize it in the future.

A study on the efficiency advancement for evacuation of the crews by ship structural improvement (선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구)

  • Kim, Wonouk;Lee, Myoungho;Kim, Jongsu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.342-348
    • /
    • 2014
  • Onshore great fires can normally be extinguished by firefighters using special firefighting equipment and its suitable method. However, offshore fires on the ships are to be extinguished by the crew without any supports from the onshore. Also, crews working on board are exposed to high risk of emergency evacuation due to the complicated structure arrangement of the ships and different accident types such as fire and ship collisions. As most of damage and loss of life in fire are associated with suffocation, shortening of evacuation time is an important factor to improve a survival rate. In this study, visibility in the accommodation area is analyzed by using the temperature and smoke flow which are obtained by the Fire Dynamic Simulator(FDS) as a Three-Dimensional Fire Analysis program to understand the survival rate of the crew upon the fire. The fire doors for most of ships are designed to close automatically when the fire alarm is activated. These automatic closing of the fire doors is a very effective system to delay the spread of flame and smoke flow for the unmanned spaces of the fire protected area. However, if the crew cannot escape within the estimated time, the crew inside the fire protected area will be damaged a lot. In this paper, the comparative analysis between the evacuations by using the fire door from the fire protected area and the suggested fire shielding structure in this study is carried out by the smoke flow rate and the temperature rise rate.

A study on the design of a general-purpose automatic fire detection system based on a private wireless network of the fire fighting communication frequency band (소방통신 주파수 대역 자가 무선망 기반 범용 자동 화재 탐지 시스템 설계를 위한 연구)

  • Kim, Minyoung;Choi, Donggyu;Jang, Jongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.246-248
    • /
    • 2021
  • This paper proposes a new general-purpose automatic fire detection system. And it deals with the contents of related research on how to design and develop for this system. The proposed system automatically notifies the user and the nearby fire department when a fire breaks out in a place where a fire alarm is installed. If this is the case, the nearby fire department can quickly confirm this fact and extinguish the fire at an early stage, thereby reducing human and property damage. The main targets of this system are houses and small buildings. The proposed fire alarm functions as a conventional fire alarm, and if a fire occurs, this fact is immediately transmitted to a nearby receiver through wireless data communication. The receiver in this paper communicates data using Korea's firefighting communication frequency band, and establishes one own network by installing it in various places to quickly receive fire alarm data at any time.

  • PDF

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.

A Development of S/W for Maintenance Management of Fire Protection in Public buildings (공공건물의 방화유지관리 S/W 개발)

  • Lee, Soo-Kyung;Ko, Chan;Kang, Gye-Myung
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.259-264
    • /
    • 1999
  • 국내에 건축되어 있는 대부분의 공공건물들은 화재발생 시 이를 신속히 발견하고, 자체적으로 소화할 수 있는 소방시설을 갖추도록 법에서 의무화하고 있다. 그러나 화재발생 시 이러한 소방설비들이 정상적인 기능을 발휘하지 못함으로 인해 조기진압에 실패함으로써 인명과 재산의 커다란 손실을 가져오는 경우가 많이 있다. 이러한 이유는 소방설비의 설계 및 시공의 문제점보다는 관리의 미숙함으로 인한 경우가 대부분이다. 그러므로 방화유지관리자의 업무를 보조하고, 건물에 설치된 소방설비를 효율적으로 점검 관리 관리할 수 있는 정보를 제공해주는 소프트웨어 개발이 필요하다. (중략)

  • PDF

Effect of Absorbent Thickness on the Noise Level Reduction of Fire-Extinguishing Nozzle (흡음재 두께가 소화노즐 소음도 저감에 미치는 영향)

  • Kim, Hak-Sun;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.99-104
    • /
    • 2019
  • In a gas system fire extinguishing system, extinguishing agents are usually stored with approximately 280 bar at $21^{\circ}C$ and are released at approximately 8 MPa through the decompression valve and orifice to quickly suppress the fire. When extinguishing agents are discharged, they cause a loud noise (approximately 140 dB), which can damage electronics, such as hard disk drives (HDDs). Therefore, the noise is becoming a serious issue in the gas extinguishing system. The method of the noise reduction by adding an absorbent is most general and in this study, the thickness of the absorbent was as a selected design variable. The noise level at the observation point and the flow characteristics inside the nozzle were numerically calculated and analyzed using the commercial code ANSYS CFX ver. 18.1.

Experimental Study on Moisture Content According to Addition of Surfactants (계면활성제 첨가에 따른 함수율에 관한 실험적 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.79-83
    • /
    • 2015
  • The fire accident is a representative type of disaster that can largely impact on business. Therefore, precautionary measures and rapid initial response is very important when a disaster occurs. The storage of porous combustibles is inevitable in coal yard, plywood processing industry, and others that are currently operating. Initial fire fighting of fire and identifying the ignition point in such a porous combustible storage space are so difficult that if the initial response is failed, being led to deep-seated fire, surface fire is likely to result in secondary damage. In addition, deep-seated fire can cause personal injuries and property damage due to a large amount of toxic gases and reignition. Therefore damage reduction measures is required around the storage space to handle a porous flammable. Improving the penetration performance of the concentration of the surfactant is carried out as underlying study, which is about an deep-seated fire extinguishing efficiency augmentation when using wetting agents. The porous materials used in the experiments is radiata pine wood flour, which occupies more than 75% of the domestic wood market. Fire fighting water is selected as Butyl Di Glycol (BDG), which is being used for infiltration extinguishing agent, and the experiment was carried out by producing a standard solution. The experiment was carried out on the basis of the Deep-Seated Fire Test of NFPA 18. The amount of watering, porous material to the internal amount of penetration, and runoff measurement out of the porous material was conducted. According to experimental results, as the surface tension is reduced, the surfactant concentration macroscopic penetration rate decreases, but infiltration to a porous material is shown to have growth characteristics.

A Study on how to improve Survey of Fire Safety Management of manufacturing plants (The Medium and Small-sized Manufacturing industry) (제조 사업장의 소방안전관리 실태조사 및 개선방안에 대한 연구 (중소규모 제조사업장 중심으로))

  • Choe, Yeong-Gi;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.483-497
    • /
    • 2013
  • 현대사회가 발전 할수록 대량산업화와 도시화가 심화되어 건축물의 초고층화 및 대형화가 증가하고 있으며, 안전적인 건축물 보다는 건물 및 제조사업장의 시각적인 디자인에 치우쳐 화재하중이 높은 건축자재의 내 외장재 및 고급스러운 장식물을 사용함으로써 그 위험뿐 만 아니라 화재발생시 대규모 인명 및 재산상의 피해를 가져오게 된다. 그리고 제조사업장화재는 화재로 인한 직접적인 손실 즉 물적 손실은 물론 생산중단으로 인한 간접적인 손실은 실로 측정하기가 어렵다. 지금까지 발생한 제조사업장화재의 발화요인별 분석은 부주의, 전기적, 미상 순으로 인한 화재가 가장 많고 발화열원은 작동기기, 담뱃불(라이터), 마찰 전도 복사등이 주요 원인이 되고 있고 대형화제 취약시설로는 공장 및 창고로 나타나고 있다. 소방방재청의 통계자료를 살펴보면 2012년 화재 발생현황 중 발화요인에 대한 화재별 장소 건수를 검토 한 결과 비주거의 화재발생 16,009건 중 5,758건으로 (36%)부주의이고, 주거에도 화재발생 10,715건 중 5,560건으로 51.9%의 부주의로 가장 높은 것으로 나타났다. 그러므로 제조사업장의 사소한 부주의로 발생하는 화재를 예방하기 위해서는 소방안전관리자의 처우개선과 기업활동규제완화의 겸직 허용을 재검토 하여야 하며, 소방안전관라자의 실무능력 강화를 위한 소방안전관리 실무교육과정을 이론적 교육 보다는 현장 실습위주로 할 필요가 있다. 이를 위해서는 소방안전관리자에 대한 법정 실무교육 횟수를 확대하여 현행 2년에 1회 에서 1년에 1회로 하고, 실무교육에 있어서도 우수송방안전관리 업체를 선정하여 화재예방에 대한 구체적인 업무를 활성화 하고, 문제 발생요소들을 분석하여 실습을 통한 소방안전관리자의 실무교육을 실시해야 할 것이다. 이러한 전문 소방안전관리자로 소방대상물의 소방교육 및 훈련을 성실히 수행 해야 할 것 이다. 한순간의 부주의로 인하여 화재가 발생하면 돌이킬 수 없는 수백명의 생명을 앗아가고, 수백억원대의 재산피해를 줄이기 위해서는 소방안전관리자의 역량을 넓히고 화재예방 업무를 최우선적으로 수행해야 할 것이다. 화재예방을 위해 소방안전관리자의 업무개선 및 전문교육을 활성화 하여 업무능력을 향상 시켜 화재발생시 초기진압에 신속하고 정확하게 대처해야 한다는 것이 전문적인 화재예방 대책 일 것이다.

  • PDF

Development of Fire Engine Travel Time Estimation Model for Securing Golden Time (골든타임 확보를 위한 소방차 통행시간 예측모형 개발)

  • Jang, Ki-hun;Cho, Seong-Beom;Cho, Yong-Sung;Son, Seung-neo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.1-13
    • /
    • 2020
  • In the event of fire, it is necessary to put out the fire within a golden time to minimize personal and property damages. To this end, it is necessary for fire engines to arrive at the site quickly. This study established a fire engine travel time estimation model to secure the golden time by identifying road and environmental factors that influence fire engine travel time in the case of fire by examining data on fire occurrence with GIS DB. The study model for the estimation of fire engine travel time (model 1) covers variables by applying correlation analysis and regression analysis with dummy variables and predicts travel time for different types of places where fire may occur (models 2, 3, 4). Analysis results showed that 17 siginificant independent variables are derived in model 1 and the fire engine travel time differs depending on the types of places where fire occurs. Key variables(travel distance, number of lane, type of road) that are included commonly in the 4 models were identified. Variables identified in this study can be utilized as indicators for research related to travel time of emergency vehicles and contribute to securing the golden time for emergency vehicles.