• Title/Summary/Keyword: 신뢰성 시험(reliability test)

Search Result 876, Processing Time 0.024 seconds

Study on the Long-term Reliability of Solar Cell by High Temperature & Humidity Test (고온고습 시험을 통한 태양전지의 장기 신뢰성에 관한 연구)

  • Kang, Min-Soo;Jeon, Yu-Jae;Kim, Do-Seok;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.243-248
    • /
    • 2012
  • In this study, The report analysed the characteristics of power drop and damage of surface in solar cell through high temperature and humidity test. The solar cells were tested during the 1000hr in $85^{\circ}C$ temperature and 85% humidity conditions, that excerpted standard of PV Module(KS C IEC-61215). An analysis of the cell surface through EL(Electroluminescence), the cell has partly change of surface in yearly. Single-crystalline Solar cell efficiency is decreased from 17.7% to 15.6% and decreasing rate is 11.9%. On the other hand, Poly-crystalline Solar cell efficiency is decreased from 15.5% to 14.0% and decreasing rate is 9.3%. A comparison of the fill factor for analysis of electro characteristic in yearly, Single-crystalline Solar cell efficiency is decreased from 78.7% to 78.1% and decreasing rate is 4.7%. On the other hand, Poly-crystalline Solar cell efficiency is decreased from 78.1% to 76.7% and decreasing rate is 1.8%. Single-crystalline has more bigger power drop than poly-crystalline by the silicon purity and silicon atom arrangement. Also, FF decreasing rate has more bigger drop than efficiency decreasing rate for the reason that the damage of surface by exterior environmental factor is the more influence in cell than other reason that is decreasing FF by damage of p-n junction.

Redundancy Management Design for Triplex Flight Control System (3중 비행제어시스템의 다중화 기법 설계)

  • Park, Sung-Han;Kim, Jae-Yong;Cho, In-Je;Hwang, Byung-Moon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.169-179
    • /
    • 2010
  • Satisfying the same probability of loss of control and essentially two fail operative performance with a triplex computer architecture requires a lot of modification of the conventional redundancy management design techniques, previously employed in quadruplex digital flight control computer. T-50 FCS for triplex redundancy management design applied an advanced digital flight control architecture with an I/O controller which is functionally independent of the digital computer to achieve the same reliability and special failure analysis and isolation schemes for fail operational goals with a triplex configuration. The analysis results indicated that the triplex flight control system is to satisfy the safety requirement utilizing the advanced flight control techniques and the system performance of the implemented flight control system was verified by failure mode effect test.

Determination of Resistance Factors of Load and Resistance Factor Design for Drilled Shaft Based on Load Test (LRFD 설계를 위한 현장타설말뚝의 주면지지력 저항계수 산정)

  • Kim, Seok-Jung;Kwon, Oh-Sung;Jung, Sung-Jun;Han, Jin-Tae;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.17-24
    • /
    • 2010
  • Load Resistance Factor Design method is used increasingly in geotechnical design world widely and resistance factors for drilled shafts are suggested by AASHTO. However, these resistance factors are determined for intact rock conditions; by comparison, most of bedrocks in Korea have weathered condition, so that applying the AASHTO resistance factors is not reasonable. Thus, this study suggests the proper resistance factors for design of drilled shaft in Korea. The 22 cases of pile load test data from 8 sites were chosen and reliability-based approach is used to analyze the data. Reliability analysis was performed by First Order Second Moment Method (FOSM) applying 4 bearing capacity equations. As a result, when the Factor of Safety (FOS) was selected as 3.0, the target reliability indexes (${\beta}_c$) were evaluated as 2.01~2.30. Resistance factors and load factors are determined from optimization based on above results. The resistance factors ranged between 0.48 and 0.56 and load factors for dead load and live load are evaluated as approximately 1.25 and 1.75 respectively. However, when the target reliabilities are considered as 3.0, the resistance factors are evaluated as approximately 50% of the results when the target reliability index was 2.0.

A Study on the Application Method of Munition's Quality Information based on Big Data (빅데이터 기반 군수품 품질정보 활용방안에 대한 연구)

  • Jeon, Sooyune;Lee, Donghun;Bae, Manjae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.315-325
    • /
    • 2016
  • Due to the expansion of data and technical progress in the military industry, it is important to extract meaningful information for assuring quality and making policies. The analysis of trends and decision making based on big data is helpful for increasing productivity in business and finding new business opportunities. We propose an application to collect reliable quality information for munitions and build a big data platform for using the accumulated information and numerical data. We verified the proposed platform using the Test Report Information Service (TRIS) system and suggest a method that utilizes unstructured and semi-structured data accumulated by TRIS. Thus, we expect that the proposed platform will help in building infrastructure for military data, making efficient strategies, and analyzing trends for assuring munitions quality.

Changes in Electrical Properties of ZnO Surge Arresters According to Surrounding Conditions (외부 환경조건에 따른 ZnO 피뢰기의 전기적 특성의 변화)

  • Lee, Seung-Ju;Lee, Su-Bong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.62-68
    • /
    • 2008
  • This paper describes the electrical characteristics of ZnO surge arresters associated with the variation of surrounding conditions. To investigate the deterioration behaviors of ZnO surge arresters due to lightning surges, 8/20[${\mu}s$], 2.5[kA] impulse currents were injected to the ZnO surge arrester under test. The leakage currents of ZnO surge arrester subject to power frequency AC voltage were measured in different surrounding temperature and wet conditions. As a result, it was found that the leakage current is increased and its asymmetry is pronounced as the number of injection of the impulse current and the ambient temperature increase. Also, in the wet test the outside leakage current flowing through the housing surface of the ZnO surge arrester is much larger than the intrinsic leakage current of ZnO surge arrester element. The results obtained in this work can be a lied as factors of improving the reliability and performance of monitoring system for surge arresters.

Measuring the Tensile Properties of the Nanostructure Using a Force Sensor (힘센서를 이용한 나노구조체의 인장물성 측정)

  • Jeon, Sang-Gu;Jang, Hoon-Sik;Kwon, Oh-Heon;Nahm, Seung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.211-217
    • /
    • 2010
  • It is important to measure the mechanical properties of nanostructures because they are required to determine the lifetime and reliability of nanodevices developed for various fields. In this study, tensile tests for a multi-walled carbon nanotube (MWCNT) and a ZnO nanorod were performed in a scanning electron microscope (SEM). The force sensor was a cantilever type and was mounted in front of a nanomanipulator placed in the chamber. The nanomanipulator was controlled using a joystick and personal computer. The nanostructures dispersed on the cut area of a transmission electron microscope (TEM) grid were gripped with the force sensor by exposing an electron beam in the SEM; the tensile tests were the performed. The in situ tensile loads of the nanostructure were obtained. After the tensile test, the cross-sectional areas of the nanostructures were observed by TEM and SEM. Based on the TEM and SEM results, the elastic modulus of the MWCNT and ZnO nanorod were calculated to be 0.98 TPa and 55.85 GPa, respectively.

A Determination of Bias between Calculational Methods for the Criticality Safety Analysis of Spent Fuel Storage Pool with Burnup Credit (연소를 고려한 사용후핵연료저장조 핵임계 안전성분석에서 계산체제간의 편차결정)

  • Byung Jin Jun;Chang-Kun Lee;Hee-Chun No
    • Nuclear Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.17-26
    • /
    • 1986
  • A test is made for a method to determine reliable bias in the criticality safety analysis of spent fuel storage pool with turnup credit between the reference and rack criticality calculation methods. The spent fuel pool of Kori Unit 1 is conceptually redesigned to the most compact rack with turnup credit, and its multiplication factors are calculated depending on fuel enrichment and burnup, by the Monte Carlo code KENO-IV as a reference and by a two-dimensional collision probability code FATAC as a practical method. Then, the computed values with the help of the above two computer codes are compared to evaluate the bias and its trend in terms of multiplication factor on fuel enrichment and turnup. The result indicates that the bias can be determined with reliability basis but without any disadvantage in criticality safety margin compared with the conventional method.

  • PDF

Evaluation of Subway Induced Vibration Effects on Building Structures (지하철 운행에 의한 건축물 진동 평가)

  • Seo, Jeong-Beom;Park, Yong-Suk;Hong, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1107-1112
    • /
    • 2008
  • Since vibration properties of a building structure were not easy to find out through a test, it was very difficult to in advance evaluate an influence of earthquake or other excitations on the building structure. However, currently, along with the development of the vibration analysis technique, it is possible to predict the structural performances of the buildings. The prediction of the vibration properties of the building structure has mainly employed a two-dimensional plane analysis so far, but not a three-dimensional analysis. The two-dimensional plane analysis encounters a reliability problem when the building is asymmetrical. This study has performed a three-dimensional modeling and vibration analysis on residential buildings when a subway passes below.

Analysis of Drifter's Critical Performance Factors Using Its Hydraulic Analysis Model (드리프터 유압 해석모델을 활용한 성능격차 유발 인자 접근 사례)

  • Noh, Dae-Kyung;Seo, Jaho;Park, Jin-Sun;Park, James;Jang, Joo-Sup
    • Journal of the Korea Society for Simulation
    • /
    • v.23 no.3
    • /
    • pp.33-40
    • /
    • 2014
  • Drifter is equipment which is hard to localize. Performance of prototype hasn't performed well compared to product of leading companies even though advanced foreign firm's product were dead copied. This study shows cases of approaching the factor which produces performance gap through drifter hydraulic analysis model which is core component of rock drill. Progression of procedure is following. 1) Securing reliability of the analysis model by comparing impact test result with analysis result. 2) Drawing a graph which indicates performance gap between prototype and drifter of advanced foreign firm by using analysis model. 3) Approaching the factor which produces performance gap with analysing variable of the analysis model. Software used for this analysis is SimulationX.

Development and Evaluation of 6-components Force/Moment Generator (6분력 힘/모멘트 발생장치 개발 및 평가)

  • Chung, Hong Sik;Joo, Jin Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.7
    • /
    • pp.621-628
    • /
    • 2016
  • This paper presents the development of a deadweight type 6-component force/moment generator for estimating characteristics of multi-component loadcell. Several new methods in moment generation are introduced in order to produce accurate force / moment and to minimize coupling effect between each force or moment components. In order to verify the reliability of the calibration system developed, estimation of the method for generating moment components and cross measurements between force or moment components are carried out utilizing a commercial torque cell and both-ends fixed beam designed in this paper.