• Title/Summary/Keyword: 신교

Search Result 179, Processing Time 0.029 seconds

Complementarity between SDQ-SR and MMPI-A in Assessing Adolescents with Internalizing Disorder : A Preliminary Study (내재화장애 청소년의 평가에서 자기보고용 강점난점척도와 MMPI-A의 상호보완성 : 예비연구)

  • Shin, Kyo Jung;Ahn, Joung Sook;Lim, Jee Young;Lee, Jin Hee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.26 no.1
    • /
    • pp.9-18
    • /
    • 2018
  • Objectives : The aims of this study were to investigate the psychopathology in adolescents with internalizing disorder using the self-report version of Strengths and Difficulties Questionnaire (SDQ-SR) and the Minnesota Multiphasic Personality Inventory for adolescents (MMPI-A), and to explore the complementarity between these two inventories for diagnostic assessment. Methods : Ninety-one patients aged 13-17 were divided into two groups by clinical diagnosis, 44 with internalizing disorder and 47 comparison group with other disorders. The data of SDQ-SR and MMPI-A completed by them were analyzed for the ability to predict internalizing disorder. Results : The logistic regression analysis revealed that diagnostic predictability increased by 2.27 times with every 1 point of SDQ-SR emotional symptom score increment. Comparison of ROC curves for internalizing disorders showed that the SE and SP of SDQ-SR emotional symptom with score over 4 was 88.94 and 78.72, respectively. For A-anx of MMPI-A with score over 56, SE and SP was 77.27 and 74.47, respectively. However, combination of these scales could not enhance the predictability of diagnostic classification more than that of SDQ-SR emotional symptom alone. Conclusions : Emotional symptom scale of SDQ-SR and A-anx, A-aln, A and INTR of MMPI-A should be important subscales for diagnosing the internalizing disorder of adolescents, however, which needs to be examined further with a larger sample size including normal control group.

Media Coverage on Religion: TV documentary (미디어의 종교보도를 위한 제언: TV 다큐멘터리 <신의 길, 인간의 길>을 통해서)

  • Lee, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.658-673
    • /
    • 2011
  • This paper examined some problems of media coverage of religion by analyzing a television documentary. The SBS-TV documentary "God's way Man's way" aired in 2008, critically presented the basic Christian doctrine. The producers of the program estimate that protestant churches in Korea have become an established power, which has influence on a societal and political level. Therefore the producers believe that they have the right to criticize that power, especially because its doctrine about salvation leads to serious conflict with other religions, for example, Islam. This program portrayed the doctrine of Jesus as a story borrowed from ancient myths. Consequently, there were harsh protests from the Korean Christian milieu, especially protestants. The author agrees that it is important for the media to critically cover the activities of religious institutions and the behaviors of religious people in the civil society. However, if producers of a documentary want to introduce controversial doctrines of one religion to an audience, they should present the orthodox ones with alternatives or opposing ones, according to the principle of objectivity and fairness of journalism. Since every religion has its mysterious doctrine that cannot be proven by science and reason, journalists should not criticize the sacred part of religion. This paper suggested some ethical points to the media, children of Enlightenment Age, when they cover the religion including its doctrine and mysterious parts.

Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery (방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사)

  • Jeong, Dong-Hyeok;Shin, Kyo-Chul;Kim, Jeung-Kee;Kim, Soo-Kon;Moon, Sun-Rock;Lee, Kang-Kyoo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons between measured and calculated by the calculation model were performed in terms of absolute dose (cGy/100 MU). As a result of evaluating calculated dose for various field sizes and depths of 5 and 10 cm in water in the geometric condition of fixed SSD (source to surface distance) and fixed SCD (source to chamber distance), most of differences were within 1% for 6 MV and 15 MV x-rays. The penumbral widths at the isocenter were approximately evaluated to 0.29~0.43 cm depending on the field size for 6 MV and 0.36~0.51 cm for 15 MV x-rays. The average transmission and leakage for 6 MV and 15 MV x-rays were 6.6% and 7.4% respectively in single level of leaves fully closed. In case of dual level of leaves fully closed the measured transmission is approximately 0.5% for both 6 MV and 15 MV x-rays. Through the commissiong procedure we could verify the dose characteristics of mMLC and approximately evaluate the error ranges for treatment planning system.

  • PDF

Effects of Acupuncture at the Acupoint Yongok$(KI_2)$, Umgok$(KI_10)$, Sobu$(HT_8)$. Sohae$(HT_3)$ on Aquaporin-2 expression, RSNA, MAP, HR, serum ANP, renin and norepinephrine in Rats (족소음신경(足少陰腎經) 연곡(然谷).음곡(陰谷)과 수소음심경(手少陰心經) 소부(少府).소해(少海) 침자(鍼刺)가 신장(腎臟) Aquaporin-2 발현(發現)과 신교감신경활성(腎交感神經活性), 혈압(血壓) 및 혈청(血淸) ANP, renin, norepinephrine에 미치는 영향(影響))

  • Youn, Dae-Hwan;Park, Chna-Kyu;Kim, Jeong-Sang;Chae, Woo-Seok;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2004
  • Objectives : This research was performed to investigate the effect of acupuncture at the $KI_2\;KI_{10}\;HT_8\;HT_3$, on Aquaporin-2(AQP2) expression related with the renal functions in rats. Methods : Acupuncture was performed during 100-seconds, 6-times, at 150-seconds intervals under anesthesia in rats. We observed rats' mean arterial pressure(MAP), heart rate(HR), renal sympathetic nerve activity(RSNA) during acupuncture and AQP2 expression by western blot method and atrial natriuretic peptide(ANP), renin, norepinephrine of plasma after decapitation. Results : The AQP2 expression was significantly increased in $HT_8$ group, but decreased in $KI_{10}$ group. Average MAP during 6-times acupuncture was significantly increased in $HT_8$ group. Average HR was significantly increased in $HT_8$ group, Average RSNA was increased in $KI_{10}$ group, but that was marginally increased in $KI_{10}$ group. Plasma renin concentration was increased in $KI_2,\;HT_3$, groups. Plasma ANP show a tendency to decrease in $KI_10\;HT_3$ groups, increased in $KI_2,\;HT_3$ but not significant. Plasma norepinephrine concentration was significantly decreased in $KI_{10},\;HT_3$ groups. Conclusions : These results suggested that acupuncture at $HT_8$ activate renal function to reuptake, but $KI_{10}$ show a decline on effect of AQP2 expression, blood pressure, nerve activity and renin.

  • PDF

Study for Multi Channel Radiation Detector Using of Microfilm and Carbon Electrode (탄소막 마이크로필름을 이용한 다채널 전리함 개발에 관한 연구)

  • Shin Kyo Chul;Yun Hyong Geun;Jeong Dong Hyeok;Oh Yong Kee;Kim Jhin Kee;Kim Ki Hwan;Kim Jeung Kee
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.111-115
    • /
    • 2005
  • We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5$\%$, linearity was less than 0.5$\%$, and dose rate effect was less than 0.7$\%$. In addition the effect of dose variation from other chambers was estimated to maximum 0.8$\%$ approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.

  • PDF

Development of Phantom for Evaluate the Suitability of Ir-192 HDR Source with Brachytherapy Tools (근접치료용 하나로 생산 Ir-192 선원의 임상기기 적합성평가용 팬톰개발)

  • Shin, Kyo Chul;Choi, Sang Gyu;Kim, Ki Hwan;Son, Kwang Jae;Jeong, Dong Hyeok;Kim, Jeung Kee
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.171-175
    • /
    • 2013
  • Applicator of various kind of number ten kinds is used to raise from efficiency of brachytherapy to maximum. The compatibility of radiation source and applicator is very important subject for safety brachytherapy. Developed high dose rate brachytherapy source through Hanaro nuclear reactor in Korea Atomic Energy Research Institute and improve compatibility with using equipment in present. In this research, we wished to evaluate stability mechanical safety of radiation source and we developed phantom for evaluate several quality about Ir-192 sealed source that improve newly in Korea Atomic Energy Research Institute and is improved. The result for suitability of Ir-192 HDR source with brachytherapy tools that did normal operation in 2.2~2.7 cm extent about change of equal curvature and consider change of sudden curvature that did normal operation in radius 1.5~1.8 cm extent.

Memories and the Locality of Pusan - Focusing on Historical Figures of Busan and Cultural Properties of Busan - (부산의 기억과 로컬리티 -<부산의 인물>과 <부산의 문화재>를 중심으로-)

  • Song, Jung-Sook
    • Journal of Korean Library and Information Science Society
    • /
    • v.43 no.2
    • /
    • pp.343-364
    • /
    • 2012
  • To examine the locality of Busan is a precondition of examining documenting localities of Busan. What is the locality of Busan and how can I explore the locality of Busan? These are the research questions of this thesis. Memory is fundamental in making an identity. So local memory is fundamental in making locality. Understanding relations between memory and identity, the author explored the locality of Busan by analyzing memories of Busan. To analyze memories of Busan is to examine historical figures of Busan and Cultural Properties of Busan which are on the website of Busan metropolitan city. The results are as follows : According to the analysis of historical figures of Busan, there are no confucius scholars who came from Busan. However in the age of civilization, Busan has produced some talented people by way of receiving a modern education. According to the analysis of Cultural Properties of Busan, Jung-gu(中區) and Seo-gu(西區) and Yeongdo-gu(影島區) are the spaces of migration. Dongnae-gu(東萊區), Suyeong-gu(水營區) and Saha-gu(沙下區) and Gijang-gun(機張郡) are the spaces of settlement. Dong-gu(東區) has changed from a space of settlement into a space of migration with the opening of the Busan Port as a momentum in 1876.

Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays (움직이는 자기장을 이용한 10 MV X-선의 선량변조에 관한 몬테칼로 계산)

  • Kim, Ki Hwan;Oh, Young Kee;Shin, Kyo Chul;Kim, Jhin Kee;Jeong, Dong Hyeok;Kim, Jeung Kee;Cho, Moon June;Kim, Sun Young
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.221-225
    • /
    • 2007
  • Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a depth region as a target on the central axis of photon beam under moving transverse magnetic field. We have calculated the depth dose curves for two cases of moving magnetic field along a depth line, constant speed and optimal speed. We introduced step-by-step shift and time factor of the position of the electromagnet as an approximations of continuous moving. The optimal time factors as a function of magnetic field position were calculated by least square methods using depth dose data for static magnetic field. We have verified that the flat depth dose is produced by varying the speed of magnetic field as a function of position as a results of Monte Carlo calculations. For 3 T magnetic field, the dose enhancement was 10.1% in comparison to without magnetic field at the center of the target.

  • PDF

Development of an Apparatus for Vertical Transfer of a PRT Vehicle Operating on a Road Network (운행 중인 PRT 차량의 수직이송을 위한 장치 개발)

  • Kang, Seok-Won;Um, Ju-Hwan;Jeong, Rag-Gyo;Kim, Jong-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2604-2611
    • /
    • 2013
  • The Personal Rapid Transit(PRT) system has been highly interested in future transportation developments due to its on-demand and optimized door-to-door transport capability. However, the major impediments to the commercialization of PRT are the high cost for construction of infrastructures as opposed to the small transport capacity and difficulty in defining the role of PRT in building a balanced transportation system. In this study, the vertical transfer device for the PRT vehicle is developed to provide more flexible and better compatible urban mobility services between means of transportation, which is expected to meet particular demands in a particular environment. This apparatus was initially designed based on the basis of vertical circulating conveyors with steel chains, which is frequently used in logistics. Its advantages are capable of the non-stop loading and reduced head-way time. Most importantly, it was intensified by the additional idea to ensure the stable and reliable transfer of the PRT vehicle fully loaded with passengers. The 1/10-scale prototype was successfully tested to demonstrate a fundamental mechanism of vertical transfer and identify unexpected user requirements prior to a real manufacturing process.