• Title/Summary/Keyword: 시험 기준

Search Result 4,326, Processing Time 0.039 seconds

IM Test and Evaluation of Reaction Level for Solid Rocker Motor (추진기관 둔감 시험평가 및 반응등급 판정)

  • Yoo, Ji-Chang;Kim, Chang-Kee;Min, Byoung-Sun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.104-108
    • /
    • 2011
  • Insensitive Munitions(IM) test methods and passing criteria of MIL-STS-2105D revised in April 2011 were studied since MIL-STD-2105(NAVY) had been created in 1982. Passing criteria of each IM tests has not been established because domestic database of IM tests for rocket motors was not enough, even though IM test and evaluation methods were well established with the same level of advanced countries. In this study, direction of the development for IM of our country was suggested through investigation and analysis of revised test methods and passing criteria.

  • PDF

엘레베이터 출입문의 방화성능 기준

  • Lee, Yu-Sik
    • 방재와보험
    • /
    • s.110
    • /
    • pp.18-23
    • /
    • 2005
  • 화재 시 연소확대 경로가 되는 엘레베이터 출입문의 층별 방화구획을 위한 우리나라의 기준과 선진 각국의 시험방법과 성능기준에 대해 고찰하는 한편, 방화성능 시험방법을 앞으로의 제도적 개선방안을 모색해보도록 하자.

  • PDF

Test Methode & kind of Equipment Verification for Control System (제어시스템의 기기검증 시험 종류와 시험방법)

  • Park, Doo-Yong;Lim, Ik-Hun;Lim, Geon-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1786-1787
    • /
    • 2011
  • 화력발전소에 사용되는 제어시스템을 개발함에 있어 하드웨어 분야는 시스템의 안정성과 신뢰성 확보를 위해 반드시 기기검증시험을 통과한 후 적용하여야 한다. 이러한 시험은 제어모듈의 모든 종류의 개별 시험과 실제 사용하고자 하는 구성으로 캐비닛에 모두 장착한 상태에서 시험하여야 한다. 이번 시험은 제어시스템을 설계하고 제작한 후 설계 제원대로 성능을 가지고 있는지에 대한 검증을 목적으로 하였으며, 유럽규격의 CE 마크 획득에 필요한 기준으로 시험을 수행한 기준을 설명한다.

  • PDF

원전고화폐기물 특성시험을 위한 시험법 선정방법

  • Kim, Gi-Hong;Yoo, Yeong-Geol;Hong, Gwon-Pyo;Jeong, Ui-Yeong;Park, Jong-Heon;Kim, Heon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.219-221
    • /
    • 2004
  • 국가의 규제기관과 처분장에서는 방사성 폐기물의 안전한 영구처분을 위하여 폐기물 수용(인수)기준을 폐기물 발생자에게 준수토록 요구하게 되는데 이러한 폐기물 수용(인수)기준은 처분시설의 가동동안 인간과 환경 보호 그리고 최대 300년간의 제도적 통제기간을 고려하여 처분장의 안전성 확보를 위하여 설정되어진다. 폐기물 수용(인수)기준중 고화체의 안정성 평가와 관련하여 미국(NRC/BTP)은 폐기물의 종류와 고화매질에 따라 유리수, 압축강도, 방사성 조사특성, 미생물 영향 특성, 침수 및 침출 특성, 열순환 특성 등에 대하여 표준시험법을 제시하였으며, 또한 그의 기술기준치도 제시하고 있다. 그리고 프랑스(DRDD/ BECC)에서는 미국보다 매우 세밀하게 평가항목들을 분류하는 등의 처분장 운영국가에서는 고화체의 안정성관련 평가시험들을 처분 환경과 처분방식에 맞게 표준화하고 있다. 한편 국내에서는 과기부 고시 제2001-32호 "중.저준위 방사성폐기물 인도규정"이 있으나 이에는 고화체 관련하여 정성적인 안정성에 대하여서만 기술되어 있다. 이에 따라 원전폐기물 고화체에 대한 안정성 평가를 위한 시험법을 선정하기 위하여 아래 그림과 같은 절차에 따라 수행토록 하였다. 우선 대표적인 천층처분 운영국가인 미국과 프랑스의 시험법 그리고 IAEA 권고 시험법과 유사관련 한국 산업표준법들을 조사하고, 이들 시험법들의 주요 차이점을 기술적 관점에서 비교평가하고, 이어서 모의 방사성 및 비방사성 고화체를 이용하여 상기 시험법들을 각각 적용하고 또한 이들 시험법들간의 차이(시험 조건, 시편의 크기 등)에 기인한 상호 비교시험을 통하여 얻어진 시험결과들을 종합적으로 비교 검토하여 보수적 관점에서 시험법을 선정하는 것으로 방향을 잡았다. 이때 시험결과를 얻기 위한 모든 과정에 품질보증 활동을 적용키로 하였으며, 시험결과 분석/평가 과정과 시험법 선정에 각계(규제기관, 학계, 발전소 현장 및 산업계 등) 전문가로부터 기술자문회의를 통하여 자문 의견을 받기로 하였다. 특히 현재 폐기물 인수 기술기준치가 설정된 국가의 시험법을 심층 있게 검토하기로 하였다.검토하기로 하였다.

  • PDF

고리 1호기 ASME 펌프 가동중 시험주기 요건완화

  • 손갑헌;최해윤;민경성;임남진;김영보
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.242-247
    • /
    • 1995
  • 원자력발전소에서 사용하는 ASME 코드펌프는 관련법규 및 기술기준에 따라 주기적으로 가동중시험을 수행함으로써 펌프의 운전가능성(operability)을 확인하도록 되어 있으며, 이러한 내용이 최종안전성분석보고서의 기술지침서에 명시되어 있다. 고리 1호기의 경우, ASME Sec. XI의 관련 규정이 1979년 Winer Addenda에서 변경되어 이를 따를 경우 매 3개월마다 가동중 시험을 수행하면 되도록 되어 있으나, 이러한 사항이 기술지침서에 명시적으로 반영 되어있지 않아 현재까지 종전 규정에 따라 매월 가동중 시험을 수행하고 있다. 따라서 본 연구는 고리 1호기 ASME 펌프의 가동중 시험주기를 1개월에서 3개월로 완화시키기 위한 기술적인 근거를 확보하기 위하여 10 CFR 50, ASME 코드 Sec. XI 및 III등 관련 법규 및 기술기준과 고리 1호기를 비롯한 유사발전소의 기술지침서, 표준기술지침서 및 지침서 개선연구결과 등과 고리 1호기 현장에서의 시험기록을 조사하였다. 이러한 검토를 통하여 가동중 시험주기를 매 3개월마다로 완화하는 것이 타당하다는 결론을 얻었으며, 그 근거로는 법규 및 기술기준에의 적합성, 유사발전소 및 표준기술지침서에서의 적용 사례, NRC의 개선연구결과의 권고사항 및 현장시험기록자료의 안정성 등을 들 수 있다.

  • PDF

Results of Developing an ITS Device Performance Test-Bed and Criteria of Its Selection (ITS 장비 성능시험장 선정기준 및 구축결과)

  • Lee, Sang Hyup;Lee, Mi Young;Baik, Nam Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.703-708
    • /
    • 2006
  • In the United States and Japan ITS device performance test-beds have been widely developed to enhance the reliability of traffic information and to expedite the standardization of components for securing the compatibility of device. In this study the selection criteria for developing ITS device performance test-bed are investigated by analyzing the cases and studies of overseas. Based on the criteria, a test-bed is developed and test-run. The importance of developing ITS device performance test-bed was identified as the result of reviewing the test run of each selection.

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.

A Study on the Combustion Test of Artificial Turf Installed on Field (실외에 설치되는 인조잔디의 연소시험에 관한 연구)

  • Min, Se-Hong;Kim, Yeon-Hwang
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.48-53
    • /
    • 2014
  • In this study, we would evaluate fire risk by domestic standard for artificial turf installed on field and roofs. Today domestic regulation for artificial turf only applies to outdoor uses and especially KS M 3888-1 has compulsion but limited to school athletic facilities. Indoor regulation complying with National Emergency Management Agency (No. 2012-35) was enacted as recommendations. Thus this study did combustion test of artificial turf installed on field. Analyzed result by 45 degree flammability test, standard was inadequate to judge the fire risk so we compared and analysed its characteristic through combustion test of flame retardant finishing carpet used as flooring. Test and assessment result of its ignitionability by 45 degree flammability test showed that carpet was satisfied with flame retardant finishing performance standard contrary to artificial turf. For this reason, by conducting cone calorimeter test, the combustion property after ignition would be analyzed and evaluated and then this study will suggest a countermeasure for strengthening standard.

K-REACH and Industrial impact (특집 - 화평법 제정(안)의 산업부분 파급 영향)

  • Han, Gi-Ju
    • The monthly packaging world
    • /
    • s.218
    • /
    • pp.53-63
    • /
    • 2011
  • "화학물질의 등록 및 평가 등에 관한 법률"도입이 산업과 경제에 미치는 영향은 화학물질에 대한 시험비용의 크기, 시험 대상 화학물질 종류, 대체물질 사용 비용부담 증가 등 간접비용의 크기 등에 따라 현저히 차이가 났다. 국내 시험 기관에서 제시한 시험비용 데이터를 이용하여 추정된 화평법 도입의 제조업 비용증대 크기는 환경부 데이터를 기준으로 할 경우에 비해 6~8배 큰 것으로 분석되었다. GDP 감소 영향(2015년 기준)도 환경부 데이터를 기준으로 할 경우 0.001~0.015%의 미미한 수준에 그칠 것이나 REACH 시험비용을 기준으로 할 경우에는 0.01~0.09%로 크게 상승하는 것으로 추정되었다. 본 연구에서는 또한 화평법 도입의 적용대상이 환경부의 계획대로 단일물질에 국한됨으로써 완제품의 경우 비용부담이 전혀 발생하지 않는 것으로 가정하였으나, 실제로는 완제품의 경우에도 화평법 도입의 영향을 받을 가능성이 있는 것으로 우려되고 있다.

  • PDF

Comparison of Korean and Foreign Standards for Cable Flame Tests (원자력 발전소 케이블의 화염 전파시험 국내외 기준 비교)

  • Lee, Dong-Min;Cho, Young-Se;Yim, Hyun-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.94-99
    • /
    • 2011
  • 원자력 발전소에 사용되는 케이블은 화재발생시 화재전파를 억제하기 위해 일정수준의 화염시험을 만족한 것을 사용하도록 규정되어 있다. 이러한 케이블 화염시험 기준은 나라마다 약간씩 차이가 있는데 본 논문에서는 국내와 미국, 프랑스, 캐나다의 원자력 발전소 케이블 화염시험 기준의 국가별 차이점을 비교 분석 하였다. 비교분석결과 각 나라의 케이블 화염시험 코드는 세부 항목별로 약간씩 차이가 있으나 전체적으로 모든 코드가 동등한 수준의 기준을 갖고 있는 것으로 분석 되었다. 따라서 어느 하나의 코드를 만족하는 전기케이블은 다른 코드의 요구 사항을 만족하는 것으로 볼 수 있다.

  • PDF