• Title/Summary/Keyword: 시험장치

Search Result 3,484, Processing Time 0.043 seconds

A Study on the Noise Reduction Method for Data Transmission of VLBI Data Processing System (VLBI 자료처리 시스템의 데이터 전송에서 잡음방지에 관한 연구)

  • Son, Do-Sun;Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Jin-Seung;Oh, Chung-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.333-340
    • /
    • 2011
  • KJJVC(Korea-Japan Joint VLBI Correlator) was installed at the KJCC(Korea-Japan Correlation Center) and has been operated by KASI(Korea Astronomy and Space Science Institute) from 2009. KJNC is able to correlate the VLBI observed data through KVN(Korean VLBI Network), VERA(VLBI Exploration of Radio Astrometry), and JVN(Japanese VLBI Network) and its joint network array. And it is used exclusively as computer in order to process the observed data for the scientific purpose KJJVC used the VSI(VLBI Standard Interface) as the VLBI international standard at the data input-output specification between each component. Especially, for correlating the observed data, the data is transmitted with 1024Mbps speed between Mark5B high-speed playback and RVDB(Raw VLBI Data Buffer). The EMI(Electromagnetic lnterference), which is occurred by data transmission with high-speed, cause the data loss and the loss occurrence is frequently often for long transmission cable. Finally it will be caused the data recognition error by decreasing the voltage level of digital data signal. In this paper, in order to minimize the data loss by measuring the EMI noise level in transmission of the VSI specification, the 3 methods such as 1) RC filtering method, 2) lmpedance matching using Microstrip line, and 3) Signal buffering method using Differential line driver, were proposed. To verify the effectiveness of each proposed method, the performance evaluation was conducted by implementing and simulations for each method. Each proposed method was effectively confirmed as the high-speed data transmission of the VSI specification.

Development and Field Application of Portable Tensioning System Using Segmental CFT Member (분절형 CFT부재를 이용한 이동식 프리텐션 제작대의 개발 및 활용)

  • Lee, Doo Sung;Kim, Tae Kyun;Lee, Sung Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.965-975
    • /
    • 2014
  • Pretension PSC (Prestressed Concrete) members are subjected to a certain limit of size as they are generally produced in the off-site plant and transferred to the site due to the large scale of the product on system. In this study, a portable pretensioning production system has been developed, which allow us to apply the pretension method on site. Considering that a 50m span PSC girder using the pretension method requires a pressing device to endure a large jacking force, the portable pretension production system has to ensure safety against such a large pretension jacking force. In this study, the portable pretensioning system to produce a 50m span pretension girder was manufactured by using CFT (Concrete Filled steel Tube) members. In order to understand the stability of the system and the behavior of the elements, a static loading test was conducted and the stability of the proposed portable pretensioning production system was confirmed. The developed portable pretension system was applied to several construction sites and was investigated the problems on site. During the pretension girder and slab members that was producted by this pretension system in construction site, it has be found the several advantages such as simple fabrication processes, reduction of prestress-loss, and a decrease of 15% compared with the fabrcation cost of post-tension girder. After due consideration of the problems, this portable pretension system will be improved.

Monitoring and Risk Assessment of Heavy Metals in Perennial Root Vegetables (다년생 근채류 중 중금속 모니터링 및 위해성평가)

  • Cho, Min-Ja;Choi, Hoon;Kim, Hye-Jeong;Youn, Hye-Jung
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.1
    • /
    • pp.55-61
    • /
    • 2016
  • BACKGROUND: This study was carried out to survey the levels of heavy metals in perennial root vegetables and to assess dietary exposure and risk to the Korean population health.METHODS AND RESULTS: Perennial root vegetables (n=214) including Panax ginseng C.A mayer, Woodcultivated ginseng, Codonopsis lanceolata, and Platycodon granditloum were collected from markets or harvested from farmhouse in Korea. Lead(Pb), cadmium(Cd) and arsenic (As) analysis were performed with microwave device and inductively coupled plasma mass spectrometer. Limit of detection for heavy metals were 0.010~0.050 μg/kg, while limit of quantitation were 0.035~0.175 μg/kg. The recovery results were in the range of 76~102%. The average contents of heavy metals in perennial root vegetables were in the range of Pb 0.013(Panax ginseng C.A Mayer)~0.070 (Wood-cultivated ginseng) mg/kg, Cd 0.009(Panax ginseng C.A Mayer)~0.034(Codonopsis lanceolata) mg/kg, and As 0.002(Panax ginseng C.A Mayer)~0.004(Plafycodon grandiflorum) mg/kg, respectively. For risk assessment, daily intakes of heave metals were estimated and risk indices were calculated in comparison with reference dose. The dietary exposures of heavy metals through usual intake were Pb 0.070 μg/day, Cd 0.041 μg/day and As 0.008 μg/day, taking 0.03%, 0.08% and 0.0003% as risk indices, respectively.CONCLUSION: The risk level for Korean population exposed to heavy metals through intake of perennial root vegetables was far low, indicating of little possibility of concern.

Studies on the Improvement of Packaging of Retorted Samgyetang (레토르트 삼계탕의 포장 개선을 위한 연구)

  • Lee, Jin-Hwan;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.15 no.2
    • /
    • pp.49-54
    • /
    • 2009
  • The effects of filling temperatures of broth and degassing method on the residual oxygen content and gas composition in the pouch and physical strength of packaging material for Samgyetang depending on the contamination of broth on the sealing layer and sterilization process were investigated. The residual oxygen content in the broth and the oxygen proportion in the headspace of package were decreased with the increase of broth temperature at filling into the pouch from 50 to 100. When the products were packaged as air-contained (Air), manually squeezed the upper side of package out to minimize the headspace (Degas) and flushed with nitrogen gas ($N_2$-Flushing) while maintaining the broth temperatures of Samgyetang at 50 or 85. The residual oxygen content and oxygen proportion were increased in the order of $N_2$-Flushing

  • PDF

A Study on the Development of Impact Analysis Model of Roll Control System for Course Correction Munition (탄도 수정탄 롤제어시스템 충격해석 모델 개발에 관한 연구)

  • Ko, Jun Bok;Yun, Chan Sik;Kim, Yong Dae;Kim, Wan Joo;Cho, Seung Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.737-742
    • /
    • 2015
  • Course correction munition are a weapson system for precision attacks and are assembled by applying a ballistic control system to existing projectiles. The roll control system is a subsystem of the ballistic control system and is placed between the guidance and control units inside of the projectile, which undergoes a 5000g lateral acceleration. Thus, it is very important to design the system to endure this load. Many developed countries evaluate the performance and safety of course correction munitions' parts using live-fire gun launch tests or a soft recovery system. However, these methods are expensive and slow. Thus, in this study, we develop impact analysis model of the roll control system using CAE. We apply the code to simulate impact phenomenon and use Johnson-Cook material model for modeling the high strain rate effect on the materials. We also design bearings in detail to analyze their behavior and verify the reliability of CAE model through gas-gun impact tests of the roll control system.

Experimental Study to Estimate the Required Flow of Fire Extinguishing System for Flame Spread Prevention on Composite Panel (복합패널 화재확산 방지를 위한 소화시스템의 소요유량 산정을 위한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.33-39
    • /
    • 2017
  • Composite panel refers to the particular plywood produced in a way of stacking the different kinds of material in sandwich form and adhering them using adhesives and is widely used as building material for its constructability and cost efficiency. But as the surface is finished with steel plate, fire extinguishing agent cannot reach to the core material because of such steel plate on surface which causes the difficulties in suppressing the fire as well as in fire-fighting activities due to collapse. This study, to deal with such problem, is intended to set the fire pipe in core material to prevent the fire from spreading and in a bid to achieve this using minimized fire water, water supply test device was fabricated to estimate the required water flow of fire extinguisher and consequently, optimal water flow (0.5 L/min) was determined through a full-scale fire test.

Sliding Wear Properties of Graphite as Sealing Materials for Cut off Hot Gas (고온차단 기밀용 그라파이트의 고온 미끄럼마모 특성 평가)

  • Kim, YeonWook;Kim, JaeHoon;Yang, HoYeong;Park, SungHan;Lee, HwanKyu;Kim, BumKeun;Lee, SeungBum;Kwak, JaeSu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1349-1354
    • /
    • 2013
  • Sealing structure to prevent flowing hot gas into the driving device, located between the driving shaft and the liner of On-Off valve for controlling the hot gas flow path was studied. Wear occurs due to the constant movement of the driving shaft controlled by actuator on graphite as the sealing material. In this paper, the dynamic wear behavior in high temperature of graphite(HK-6) to be used as sealing material was evaluated. Reciprocating wear test was carried out for the graphite(HK-6) to the relative motion between shaft materials(W-25Re). The results of friction coefficient and specific wear rate according to contact load, sliding speed at room temperature and $485^{\circ}C$ considering the actual operating environment were evaluated. Through the SEM analysis of the worn surface, third body as lubricant films were observed and lubricant effect of third body was considered.

Development of Electronic Float (전자부자 개발)

  • Kim, Chi-Young;Kim, Won;Kim, Dong-Gu;Lee, Chan-Joo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.508-512
    • /
    • 2007
  • 하천유량자료는 이수, 치수, 수질관리 등의 목적으로 널리 사용되기 때문에 여러 가지 수문관측 자료 중 가장 중요하다고 할 수 있다. 그러나 우리나라의 유량자료는 여러 가지 한계를 가지고 있어서 수문자료로서 제대로 사용되지 못하고 있는 실정이다. 특히 홍수기 부자측정 방법에 의해 산정된 유량자료는 측정 여건, 방법, 기기 등의 한계로 인해 그 정확도가 더욱 낮다. 부자에 의한 유량측정은 일정거리를 유하하는 부자의 유하시간을 측정하여 평균유속을 구하고, 사전에 측량된 횡단면으로부터 유하한 개별 부자의 해당 단면적을 구하여 부분 단면적을 구한다. 구해진 개별 부자의 평균유속과 부분 단면적을 곱하여 부분유량을 산출한 후, 각 부분유량을 합하여 전체 유량을 계산한다. 이와같은 부자법은 유속-면적법이 가지고 있는 흐름 단면적 계산, 평균유속 계산의 불확실도 이외에 유하경로에 의한 불확실도, 부자 유하 시간의 불확실도, 유속 보정 계수의 불확실도 등을 포함한다. 기존 홍수 유량측정에 사용하고 있는 부자법은 육안에 의해 부자의 위치를 파악하고, 가상의 횡단선을 통과할 때 육안으로 관측하여 유하시간을 측정하는 방법이기 때문에 정확한 유량측정에 한계가 있다. 뿐만 아니라 측정에 다수의 인원이 필요하며, 홍수시 많은 비가 내리거나, 야간에 측정하는 경우에는 부자의 식별이 곤란하고 측정 여건이 불량하기 때문에 측정에 큰 애로가 있다. GPS를 이용한 전자부자는 자동으로 유속을 측정하기 위해 기존 홍수유량 측정에 사용하던 부자에 전자장치를 추가하는 것을 말한다. 본 연구에서는 GPS와 RF를 기존 봉부자에 추가하여 봉부자의 유속과 봉부자의 괘적을 측정할 수 있는 전자부자를 개발하였다. 개발한 전자부자는 기존 육안에 의한 방식보다 자동으로 정확한 유속 측정이 가능하며, 동시에 여러 개의 봉부자 사용이 가능하여 측정시간 절감이 가능하고, 비가 내리거나 야간에도 자동으로 측정이 가능한 특징을 지니고 있다. 본 연구에서 개발된 전자부자는 3개 주파수 대역을 이용할 수 있도록 개발하여, 총 15개의 부자를 동시에 투하할 수 있도록 개발하였다. 전자부자 시험결과 50m, 100m 구간 유속을 검증한 결과 50m의 경우 최대 평균 5.97%, 평균 2.38%의 상대오차를 나타냈으며, 100m의 경우 최대 5.43%, 평균 1.9%의 상대오차를 나타냈다. 자연하천 유량측정 결과 댐 방류량 대비 기존방법의 경우 약 8.2%의 상대오차를 지니고 있었으며, 전자부자의 경우 약 2.8% 상대오차를 지니고 있어, 기존 부자법에 비해 전자부자법이 5.4%의 상대오차 개선효과를 지니고 있었다. 이와같은 오차의 범위는 실제 하천에서 전자부자를 이용하여 유속측정이 가능함을 나타내는 결과이다.

  • PDF

Identification of Factors Affecting Errors of Velocity Calculation on Application of MLSPIV and Analysys of its Errors through Labortory Experiment (MLSPIV를 이용한 유속산정시 오차요인 규명 및 실내실험을 통한 유속산정오차 분석)

  • Kim, Young-Sung;Lee, Hyun-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.153-165
    • /
    • 2010
  • Large-Scale Particle Image Velocimetry (LSPIV) is an extension of particle image velocimetry (PIV) for measurement of flows spanning large areas in laboratory or field conditions. LSPIV is composed of six elements - seeding, illumination, recording, image transformation, image processing, postprocessing - based on PIV. Possible error elements at each step of Mobile LSPIV (MLSPIV), which is a mobile version of LSPIV, in field applications are identified and summarized the effect of the errors which were quantified in the previous studies. The total number of elemental errors is 27, and five error sources were evaluated previously, seven elemental errors are not effective to the current MLSPIV system. Among 15 elemental errors, four errors - sampling time, image resolution, tracer, and wind - are investigated through an experiment at a laboratory to figure out how those errors affect to velocity calculation. The analysis to figure out the effect of the number of images used for image processing on the velocity calculation error shows that if over 50 images or more are used, the error due to it goes below 1 %. The effect of the image resolution on velocity calculation was investigated through various image resolution using digital camera. Low resolution image set made 3 % of velocity calculation error comparing with high resolution image set as a reference. For the effect of tracers and wind, the wind effect on tracer is decreasing remarkably with increasing the flume bulk velocity. To minimize the velocity evaluation error due to wind, tracers with high specific gravity is favorable.

The Volatile Organic Compounds Released from PVC Food Wrapping Film at Normal Use Condition (식품용 PVC 포장필름의 실생활 사용환경에서 방출되는 휘발성 유기화합물)

  • Nam, Sung-Hyun;Kim, Man-Goo;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.683-692
    • /
    • 2000
  • The volatile organic compounds emitted from food wrapping films when it was used at high temperatures. However, the testing method based on solvent extraction may not be suitable for determination of volatile organic compounds from food wrapping films. Therefore, thermal extraction device was investigated in the study for reflection of actual usage conditions at home and restaurant. In this study, PVC food wrapping films were exposed to normal use condition controlled from $50^{\circ}C$ to $120^{\circ}C$ and collected on sorbent trap. Then, emitted VOCs from the films were analyzed with On-column cryofocusing-GC/MS system. The major VOCs emitted from films were $C_{12}-C_{18}$ paraffinic hydrocarbons, dimethylphthalate, alkylphenols, known as endocrine disrupting chemical, such as tetramethylbutylphenol, tert-butylphenol, and nonylphenol. The concentration of tetramethylbutylphenol emitted from PVC films was $0.07ng/cm^2$ at $50^{\circ}C$, rapidly increased with temperature, $3.94ng/cm^2$ at $100^{\circ}C$.

  • PDF