Performance Test of Vitiated Air Heater with High Temperature and High Pressure (고온 고압 공기가열기 성능시험)

  • Lee, Jungmin;Na, Jaejeoung;Hong, Yunky;Kim, Jeongwoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • This study presents the performance test results and the analyses of the vitiated air heater with high temperature and high pressure. In the performance test, four test conditions and three rake measurement conditions were implemented. In the results of the performance test, the vitiated air heater met targets of temperature and flow rate, and the performance with maximum temperature of 2000 K and maximum combustion pressure of 40 bar was confirmed. Flow rate of provided methane increased 36% more than what was calculated, and 19.6% difference was displayed between measured temperature and theoretically calculated temperature.

스트레인 게이지의 온도특성과 극저온 환경에서의 거동

  • 주진원
    • Journal of the KSME
    • /
    • v.32 no.6
    • /
    • pp.514-523
    • /
    • 1992
  • 스트레인 게이지를 이용하여 변형측정을 할 때 온도변화의 영향으로 나타나는 겉보기 변형도와 게이지 상수의 변화에 대하여 설명하였고 실제 측정시 정확한 측정값을 얻기위한 온도보상 방 법에 대하여 기술하였다. 온도변화에 의한 겉보기 변형도의 값은 기계적 하중에 의한 변형도에 비하여 무시할 수 없는 큰 값을 나타내기 때문에 적절한 보상에 의하여 정확한 측정값을 얻어 내야 한다. 항공우주산업, 원자력산업 등의 분야에서 널리 응용되는 극저온 환경에서 겉보기 변 형도와 게이지 상수의 측정결과를 제시하였다. 극저온에서는 자체 온도보상된 스트레인 게이지라 할지라도 대단히 큰 온도영향을 받기 때문에 본시험에서 제시한 바와 같이 측정결과를 온도보 상하여 처리해야만 의미있는 결과를 얻을 수 있다. 본 시험에서 4차식으로 구해진 겉보기 변형 도에 대한 특성곡선과 게이지 상수에 대한 시험결과는 극저온에서 변형을 측정할 때 직접적으로 보상하여 사용될 수 있다.

  • PDF

원자로 냉각재 배관용 SA516-Gr.70 강의 파괴저항성에 미치는 온도 및 하중속도의 영향

  • 윤지현;이봉상;오용준;김진원;홍준화
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.48-53
    • /
    • 1998
  • 원자력 발전소 배관계통에 파단전 누설 (LBB) 설계개념의 적용을 위해서는 원자로 가동온도에서의 재료의 파괴저항성 평가가 필수적이다. 본 연구에서는 국내 원자로의 1차 냉각계통배관의 엘보우 소재로 사용되는 SA516-Gr.70 강의 파괴저항성에 미치는 DSA (Dynamic Strain Aging, 동적변형시효) 영향을 고찰하였다. 파괴저항성 평가를 위해 원자로 가동온도를 포함한 상온~50$0^{\circ}C$ 온도영역에서 준정적 하중에서부터 지진 하중 정도의 동적 하중까지 하중속도를 달리하여 직류전위차법 (DCPD) 이용하여 J-R 시험을 행하였다. J-R 시험결과, SA516-Gr.70 강은 특정한 온도와 하중속도의 조합에서 파괴저항성이 크게 떨어지는 양상을 보였으며, 낮은 파괴저항성을 나타내는 온도는 하중속도가 증가함에 따라 높은 온도쪽으로 이동하는 전형적인 DSA 감수성을 보였다. 인장시험을 통해서도 큰 폭의 serration 이 관찰되었으며 SA516-Gr.70 강에서 파괴저항성의 변화와 DSA 현상과의 연관성을 고찰하였다.

  • PDF

The Influence of Specimen Volume on the Adiabatic Temperature Rise of Concrete (콘크리트 단열온도 상승량에 미치는 시험체 용적의 영향)

  • Bae, Jun-Young;Cho, Sung-Hyun;Shin, Kyung-Joon;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.659-666
    • /
    • 2012
  • To secure the thermal crack resistance of mass concrete, researches and the field applications of low heat portland cement (LPC), ternary blended cement (TBC) which is produced by blending ordinary portland cement with blast furnace slag and fly ash, and early strength low heat blended cement (EBC) increased in recent years. Although the model for adiabatic temperature rise is necessary for estimating the risk of thermal cracking of concrete structures, sufficient data have not been accumulated for these mixtures. In addition, the differences in adiabatic test results have been reported for the volume of test specimens. Therefore, the present study evaluated the characteristics of adiabatic temperature rise based on the type of binder and the volume of the adiabatic test specimen. Test results indicated that the maximum temperature rise ($Q_{\infty}$) and the reaction factor (r) of TBC were the lowest. Test results also showed that $Q_{\infty}$ and r changed with respect to the volume of test specimen. $Q_{\infty}$ and r obtained from 6l equipment were lower than those of 50l equipment. Therefore, corrections with respect to this phenomenon was confirmed and the corrections factors are presented.

An Experimental Study for Estimation of Effective Temperature for Design in Steel Box Girder Bridge (강박스거더교의 설계 유효온도 산정을 위한 실험적 연구)

  • Lee, Seong Haeng;Shin, Hyo Kyoung;Kim, Kyoung Nam;Jung, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.449-458
    • /
    • 2016
  • The temperature data were measured for two years in a bridge specimen and the bridge in service nearby in order to calculate the effective temperature for thermal loads in steel box girder bridge. The maximum and minimum effective temperatures were calculated in the bridge specimen and the bridge according to air temperature in 2014, 2015 and 2years. The effective temperatures calculated in this study were compared the Euro code and the Highway Bridge Design Criteria. The coefficients of determination in the maximum effective temperature and the Euro code for 2 year were calculated from R = 0.927, R = 0.894 in a bridge specimen and the bridge respectively. Those of minimum temperature and the Euro code were analyzed from R = 0.992, R = 0.813 in two bridge respectively. Also, the results were evaluated as being very similar, or slightly increased as compared with the maximum temperature of the Korean Highway Bridge Design Code(Limit State Design).

A Study on the Smoldering hazard of Rice bran dust. (쌀겨 분진의 훈소 위험성에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.12-17
    • /
    • 1999
  • We intended to investigate combustion properties of rice bran dust. Combustion properties of h rice bran dust according to size distribution and amount were measured as temperature v variation with time using spontaneous ignition apparatus. Moreover, combustion properties w with blowing or without blowing condition were checked in order to investigate combustion p properties in spontaneous ignition apparatus according to flow condition of air. A As the mass and size of rice bran dust was increased, i띠ti외 smoldering temperature was l lowered. All of combustion forms were smoldering combustion. Initial smold얹ing temperature w was slightly lower with blowing condition than without blowing condition in spontaneous i ignition apparatus, which condition made heating value high.

  • PDF

월성 3호기 격납건물 압력시험을 통한 구조건전성 평가

  • 백용락;이성규;이상국;신재철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.831-836
    • /
    • 1998
  • 원자로 격납건물은 그 기능적 중요성 때문에 건설종료후 반드시 원자로 가상사고를 가정한 조건에 대해 구조적 건전성을 입증하여야 한다. 본 논문은 이러한 요건에 따라 수행된 월성 3호기 원자로 격납건물 구조건전성 시험(SIT : Structural Integrity Test)의 개요와 결과를 분석한 것으로 시험결과 월성 3호기는 설계시 고려한 허용범위내에서 거동하였으며 사고시 압력하중이 큰 경수로형 원자로와 달리 시험기간중 외기 온도 변화에 민감한 변화를 보인 것으로 확인되었다. 아울러 시험결과의 정확한 평가를 위해서는 시험전 충분한 기간동안 온도변화가 계측되어야 하며, 계측기 출력의 안정화가 계측성과의 신뢰도를 높이는 필수인자임이 확인되었다.

  • PDF

가압경수로 가압기 안전밸브 보수후 압력설정치 시험

  • 신대수;류용호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.386-391
    • /
    • 1998
  • 국내 가압경수로 가압기 안전밸브는 운영기술지침서에 따라 운전 중과 같은 환경조건에서 압력설정치(2,485 psig) 시험을 수행하도록 규정되어 있다. 가압기 안전 밸브는 일정한 주기로 압력설정치 시험이 수행되고 있으나, 시험시의 주변 온도, 사용 유체 등 그 시험 조건에 따라 압력설정 허용치 $\pm$1% 이상의 편차가 발생할 수 있음이 확인되고 있다. 본 연구에서는 압력설정치 시험시의 주변온도 상태에 따른 설정치 변동 사례를 조사하고, 보수 후 압력설정치 조정을 위한 대체 방안과 그 문제점을 고찰하였다.

  • PDF

A Study on the Variation of Temperature and the Deformation Characteristics in Asphaltic Concrete Pavement by Air Temperature (대기온도(大氣溫度)에 따른 아스팔트포장(鋪裝) 내부(內部) 온도변화(溫度變化)와 변형특성(變形特性)에 관(關)한 연구(硏究))

  • Kang, Min Soo;Kim, Soo Sam;Lee, Suk Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1115-1128
    • /
    • 1994
  • The condition of temperature gradients in asphaltic concrete (Ascon) pavement have been analyzed based on the data collected from 5 major sites in Korea. From this. considering heat transfer by insolation flux and air temperature within pavement slab. temperature variation on the surface of pavement was computed and numerical model using the theory of thermal conductivity was applied to estimate the temperature gradients in depth. To investigate the present condition of asphalt generally used in Korea. the asphalt property tests were applicated on 5 different AP-3 (AC 85~100), and AP-5 (AC 60~70) asphalts classified by penetration index. Uniaxial compression test and indirect tensile test were also carried out for varying temperature conditions to analyze the effect of temperature on the deformation characteristics of Ascon pavement by calculating the variation of static elastic modulus and layer coefficients.

  • PDF

Temperature Log in Boreholes (착정공 온도검층의 이용)

  • 염병우;김형찬
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.73-77
    • /
    • 1997
  • Temperature log is an effective method for evaluating the thermal situation and ground water flow path within boreholes. When pumping is proceeding, the continuous temperature logs in a neighboring holt are very helpful to assess connectivity between holes. Mean geothermal gradient is calculated as 26.6$^{\circ}C$/km from 400 bottom hole temperatures, their depths, and the annual mean temperature at each location. Various examples of temperature logs in crystalline rocks are described: first examples show linear increases in homogeneous granitic rocks. Another one illustrates that isolated aquifers have connected each other after a borehole is completed. Slopes of temperature gradient indicate ground water inlet and/or outflow within a borehole. The other log concludes that thermal response in observation borehole induced by pumping is related to the location of interconnected fractures.

  • PDF