• Title/Summary/Keyword: 시험렌즈

Search Result 89, Processing Time 0.033 seconds

EYE IRRITATION TEST OF LENS WASHING AGENTS CLlWELLTM ON NEW ZEALAND WHITE RABBITS (렌즈 보존액 CLlWELLTM에 대한 안점막자극성시험)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.67-78
    • /
    • 2007
  • The eye irritant test of lens washing agent, CLIWELL$^{TM}$ was conducted using Draize methods according to KFDA Guidelines. In addition, to test the potential toxicity of test articles, the ratio of inflammatory cells and non-inflammatory epitheloid cells was also observed using smear cytology methods against ocular discharge. At sacrifice, the histopathological changes on Cornea, Iris, Retina and Sclera were also observed in all animals. Slight irritancy of cornea and conjunctiva was observed at 1, 2 and 3 days after dropping in non-washing group. The MIOI of these points are detected as 4.50, 1.67 and 0.67, respectively. In washing group, slight irritancy of cornea and conjunctiva were observed at 1 and 2 days after dropping with MIOI as 0.67, respectively. Therefore, CLIWELL$^{TM}$ was considered as non-irritating materials because the MIOI is detected below 5.00 throughout the whole experimental periods in both washing and non-washing groups and the IAOI was also detected as 4.50. Except for significant increase of the inflammatory cell ratios in ocular discharge at 1 day after dropping of non-washing group compared to that non-treated intact eyes, no meaningful changes on smear cytology of ocular discharges are observed in this study. In addition, no abnormal histopathological changes on the cornea, iris, retina and sclera were also detected in CLIWELL$^{TM}$ dropping group compared to that of non-treated intact eyes.

  • PDF

Eye Irritation Test of Lens Washing Agents SOLOCARETM on New Zealand White Rabbits (렌즈 보존액 SOLOCARETM에 대한 안점막자극성시험)

  • Jang, Woo-Yeong;Park, Eun-Kyu;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.299-310
    • /
    • 2006
  • The eye irritant test of lens washing agent, $SOLOCARE^{TM}$ was conducted using Draize methods according to KFDA Guidelines 1999-61. In addition, to test the potential toxicity of test articles the ratio of inflammatory cells and non-inflammatory epitheloid cells were also observed using smear cytology methods against ocular discharge. At sacrifice, the histopathological changes on Cornea, Iris, Retina and Sclera were also observed in all animals. Slight (1~2 degrees) irritancy of cornea and conjunctiva were observed at 1, 2 and 3 days after dropping in non-washing group. The MIOI of these points are detected as 4.33, 3.33 and 2.00, respectively. In washing group, slight irritancy of cornea and conjunctiva were restricted to 1 and 2 days after dropping with MIOI as 3.00 and 1.33, respectively. Therefore, $SOLOCARE^{TM}$ was also considered as non-irritating materials because the MIOI is detected below 5.00 throughout the whole experimental periods in both washing and non-washing groups and the IAOI is also detected as 4.33 (1 day after dropping). No meaningful changes on smear cytology of ocular discharges are observed in this study compared to that of non-treated intact eyes. In addition, no abnormal histopathological changes on the cornea, iris, retina and sclera were also detected in $SOLOCARE^{TM}$ dropping group compared to that of non-treated intact eyes.

  • PDF

Contamination measurement, Analysis & Control for Satellite (인공위성의 오염 측정, 분석 및 관리)

  • Lee, Sang-Hoon;Hong, Seok-Jong;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • It is necessary to be careful about contamination control to minimize the accumulation of the contamination material on satellite surface during the I&T phase. In the space environment which characterized by high vacuum, high and very low temperature, contamination material causes satellite to lose its own performance. Especially, contamination material can accumulate on critical surfaces such as lenses, mirrors, and sensors. KARI(Korea Aerospace Research Institute) conducts the clean room to control and minimize the contamination effect. This paper introduces the principle of contamination and the method of measure and analysis for the contamination.

외계행성 탐색시스템 개발 사업 현황

  • Kim, Seung-Ri;Lee, Chung-Uk;Park, Byeong-Gon;Cha, Sang-Mok;Lee, Jae-U;Lee, Byeong-Cheol;Kim, Dong-Jin;Lee, Yong-Seok;Gu, Jae-Rim
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.203.1-203.1
    • /
    • 2012
  • 한국천문연구원에서는 2009년부터 외계행성 탐색시스템(KMTNet; Korea Microlensing Telescope Network) 개발 사업을 수행하고 있다. 이 사업에서는 중력렌즈 방법이나 별표면 통과(Transit) 방법으로 외계행성을 탐색하기 위하여, 1.6m 광학 망원경과 3.4억 화소의 모자이크 CCD 카메라로 구성된 2도x2도의 광시야 관측시스템을 제작하고 있다. 이 시스템은 2014년까지 남반구의 칠레 CTIO(1호기), 남아공화국 SAAO(2호기), 호주 SSO(3호기)에 설치될 예정이다. 우리은하 벌지 영역을 24시간 연속 모니터링 관측하여 외계행성과 변광천체를 탐색하는 것이 핵심연구주제이다. 광시야 망원경 1호기는 미국 Tucson에 건설된 관측시설 Prototype에 설치하여 공장시험을 수행하고 있다. 망원경의 지향(pointing) 정밀도와 Lucky Imaging 방법을 이용하여 얻은 광시야 광학계 성능 등 공장시험 결과를 보고할 것이다. 또한 핵심연구주제 이외의 관측시간을 활용할 2차 연구주제를 공모하여 심사한 결과를 제시할 것이다. 아울러 모자이크 CCD 카메라 제작, 남반구 관측소 설치 준비, 대용량 자료처리 시스템 개발, 남반구 관측소 운영 계획 등 전반적인 사업 현황과 계획을 발표할 것이다.

  • PDF

The Error and the Graphical Presentation form of the Binocular Vision Findings (양안시기능 검사 값의 오차와 그래프 양식)

  • Yoon, Seok-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.39-48
    • /
    • 2007
  • The stimulus of accommodation A, the stimulus of convergence C and the prism diopter ${\Delta}$ are reviewed and redefined more obviously. How the A and C are managed in the practice are reviewed and summarized. As a result, the common practical process of the binocular vision findings is most suitable in the case of the $l_c=26.67mm$, where the near distance is measured from the test lens to the near target and its value is 40 cm and the average of the P.D equal to 64 mm. The $l_c$ is the distance between the test lens and the center of rotation. Those values were used at calculating the various values in this paper. The error of the stimulus of accommodation values which are evaluated by the practically used formula (5) are calculated. Where the distance between lens and the principle point of eye is 15.07 mm ($=l_H$). The incremental stimulus of convergence values P' caused by the addition prism $P_m$ are evaluated by the recursion computation method. The P' are varied with the $P_m$, the distance $p_c$ between the prism and the center of rotation, the initial convergence value (or inverse target distance) $C_o$ and the refractive index n of the prism material. The recursion computation method and the other formulas are described in detail. In this paper n=1.7 is used. The two factors by which the P' is increased are exist. The one which is major is the property by which the values of convergence whose unit is ${\Delta}$ are not added in the generally way. The other is the that the actual power of the prism is varied with the angle of incidence light. And the P' is decreased remarkably by an increase in the $p_c$ and $C_o$. The $P^{\prime}/P_m$ are calculated and graphed which are varied with the $p_c$ and $C_o$, where the $P_m=20{\Delta}$, P.D=64 mm and n=1.7. The index n dependence of the $P^{\prime}/P_m$ is negligible (refer to fig. 6). The $p_c$ are evaluated at which the P' equal to the $P_m$ for various $P_m$ (refer to table 1). The actual values of the stimulus of convergence and accommodation which are manipulated simply in the practice are calculated. Two graphical forms are suggested. The one is like as the commonly used one. But the stimulus of convergence and of accommodation values in the practice are positioned at the exact positions when the graphic is made (refer to fig. 9). The other is the form that the incremental stimulus of convergence values caused by the addition prisms are represented at actual positions (refer to fig. 11).

  • PDF

Development of High power LED module for Channel letter (Channel letter용 High Power LED Module 개발)

  • Kim, Jin-Hong;Song, Sang-Bin;Kim, Gi-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.95-100
    • /
    • 2007
  • Channel letter용 High Power LED Module 개발하기 위하여, 1W 백색(단색) LED 1EA LED Module과 1W 백색(단색) LED 3EA LED Module, 3W RGB LED 1EA LED Module에 대한 3종의 제품 개발하고, 고효율 RGB LED SMPS 회로 설계, 광색 가변을 위한 RGB LED 최적 배치 및 렌즈 설계, 고출력 1W LED Module 방열 설계 및 기구 개발, SMPS 회로 및 RGB LED 배열 회로 통합 시제품 직접 제작하였다, 신뢰성 평가 및 성능 시험 등을 실시하였으며, T자형 Channel letter에 기존 고휘도 LED Module과 개발된 고출력 LED Nodule을 동시에 적용한 결과, 기존 고휘도 LED Module를 사용하였을 경우에는 $1W{\times}10$개로 10W의 전력을 소비하였으나 개발된 고출력 LED Nodule은 $3W{\times}3$개로 9W의 전력을 소비하였으며 1W의 에너지가 절감되었음에도 불구하고 평균 휘도는 약 2.5배, 균제도는 1.43 배가 더 우수한 결과를 얻었다.

  • PDF

Lifetime Estimation of High Power White LED for Lighting Use (고출력 조명용 White LED의 수명예측)

  • Lee, Myeong-Hoon;Shin, Seung-Jung;Kwack, Kae-Dal
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1343-1348
    • /
    • 2008
  • LEDs which have many merits are widely used in the field of light devices, and have rapidly replaced old light devices such as incandescent or fluorescent lamps. Long life, on the order of 50,000 to 100,000 hours, is one of the key features of light emitting diodes(LEDs) that has attracted the lighting community to this technology. High Power white LEDs have yet to demonstrate this capability. This paper planed accelerated life test that has two factor(temperature, current) and two levels. Finally, using ALTA programs, we estimated the common shape parameter of Weibull distribution, life-stress relationship, B10 life and accelerating factors.

  • PDF

Resolution improvement of 3D images in plane-based computational integral imaging reconstruction technique (평면기반 컴퓨터 집적 영상 재생 방법에서 3차원 영상의 해상도 개선)

  • Shin, Dong-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1944-1949
    • /
    • 2007
  • In this paper, a new plane-based computational reconstruction technique for three-dimensional (3D) objects in 3D internal imaging based on a lens model is proposed. For the proposed technique, computational experiments have been carried out for various test images. Resolution of the reconstructed images is analyzed and compared with that obtained by the conventional technique. From experiments, it is shown that the resolution of a 3-D reconstructed image was improved by using the proposed technique.

Designing a kmultiview 3D display system based on a spatiotemporal multiplexing (시공 분할방식을 이용한 다시점 삼차원 디스플레이 시스템의 설계)

  • 손정영;김재순;전호인
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.368-372
    • /
    • 1998
  • A 16-views 3 dimensional imaging system is designed by spatially combinding two 8-views time multiplexed image channels. Each 8-views channel composed of 3 primary color CRTs and a dichroic beam splitter which combining the three CRTs as one channel. Each CRT displays 8-view images time sequentially. These images are projected to a holographic screen of a size 1$\times$0.8 $m^2$ through a projection optics. Characteristics of the three different configurations of projection optics are examined with the optics designing program "DEMOS" to select an optimized projection optics for the system. The configulation of the optimized projection optics is found like following; images from each channel combined by two-fold mirror are projected by a projection objective through a 16-strips LCD shutter. In this configuration, the shutter should be located at the entrance pupil of the objective, and the folded edge of the two-fold mirror should contact symmetrically to the center line of the shutter.e shutter.

  • PDF

A Study on Improvement Technology of Image Resolution using Mobile Camera (이동 카메라를 이용한 사진 해상도 향상 기술 연구)

  • Buri Kim;Jongtaek Oh
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.93-98
    • /
    • 2023
  • Recently, as the size of display devices tends to increase and taking pictures with smart phones has become commonplace, the need for taking high-resolution pictures with smart phones is increasing. However, when the lens size of a camera is limited, such as in a smartphone, there is a physical limit to increasing the resolution of a photo. This paper is about a technique for increasing the resolution of a picture even when using a small-sized lens like a smartphone camera. It is to take multiple pictures while moving the smartphone, and to increase the resolution by combining these pictures into one picture. First of all, two pictures were taken while moving the smartphone horizontally for the 2D picture. Processes such as camera matrix estimation, and homograph inverse transformation were performed using OpenCV, and the resolution was improved by synthesizing one picture. It was confirmed that the resolution was improved in parts such as oblique lines or arcs on several test pictures.