• Title/Summary/Keyword: 시험렌즈

Search Result 89, Processing Time 0.06 seconds

A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting (구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구)

  • Park, Seong-Jong;Joo, Seok-Hee;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.455-462
    • /
    • 2004
  • In this paper, we measured and analysised the power change of tear lens for 85 patients - 170 myopia eyes - who are fitted using RGP lens, considering the BGR of RGP lens, the corneal astigmatism power, and corneal curvature. We got the following results from these experiments; 1. When the BCR of RGP lens changes, the diopters of tear lens of "on-k", 0.05Pt, 01.0Ft, 0.05St, and 0.10St are -0.25D, -0.46D, -0.63D, +0.07D, and +0.26D, respectively. 2. When the corneal astigmatism power changes, the diopters of tear lens of group below 0.75D, group of 1.00D~1.25D, group of 1.50D~1.75D, and group over 2.00D in "on-k" state, are -0.25D, -0.18D, -0.09D, and -0.39D, respectively. 3. When the corneal astigmatism power changes and the BCR of test lens is changed by 0.05mm step, the change values of tear lens diopter for 0.05St and 0.05Ft approximate to ${\pm}0.25D$, while these for 0.10St and 0.10Ft don't approximate to the value below ${\pm}0.25D$.[are irregular value below ${\pm}0.25D$.] 4. When the corneal curvature and the HCR of RGP lens change, the diopters of tear lens of group below 7.50mm, group of 7.55~7.80mm, group of 7.85~8.20mm, and group over 8.25mm in "on-k" state, are -0.40D, -0.11D, -0.20D, and -0.19D, respectively. 5. When the BCR of test lens is changed by 0.05mm step and the corneal curvature increases, the change values of tear lens diopter decrease, while these over 8.25mm are mean value ${\pm}0.17D$ and the value below ${\pm}0.25D$.

  • PDF

Development of an Equipment for measuring the MTF of Camera Phone Lenses (카메라폰 렌즈의 MTF 측정장치 개발)

  • Hong, Sung-Mok;Jo, Jae-Heung;Lee, Yun-Woo;Lee, Hoi-Yon;Yang, Ho-Soon;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • In order to evaluate the performance of phone camera lenses, we have developed equipment for measuring the modulation transfer function(MTF) for small size lenses. The equipment is composed of an an image analyzer, object generator, and a lens mount. The object generator is rotated for on and off-axis measurement. The lens mount is of horizontal type and tiltable for precise alignment to the optical axis. After the initial alignment process, the measurement is done within 10 seconds automatically

Diameter of the retinal blur circle in a artificial hypermetropia (인워적 원시에 따른 망막에서 착란원 크기)

  • Choi, Woon Sang;Kim, Yoon-Kyung;Oh, Heung Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.145-149
    • /
    • 2005
  • In a artificial hypermetropia with the accommodative response, we investigated a diameter of blur circle as a function of test lens refractive power. In a schematic eye model of the hypermetropia, the second focal length along to accommodated power of the crystal lens are calculated as a function of test lens power and, also distance between the retina and exit pupil are calculated as a function of accommodated power. As these results are compared, the size of blur circle on the retina are obtained.

  • PDF

Effects of Base Curve on Fitting with the current Soft Contact Lenses (베이스 커브에 의한 콘택트렌즈 피팅 효과)

  • Choe, Oh Mok;Gang, Myoung Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • The study investigated the effects of base curve radius art the fit of thin, mid-water contact lenses. It was found that central corneal curvature(as measured with the keratometer) was not predictive of the best fitting base curve. Proper lens fit may be the single most important factor that ultimately determines the success of contact lens wear. Comfort, vision, and physiological response are all dependent on the fit of the lens. The percent of optimal fits was highest with the 8.4 mm base curve lens for all three ranges of keratometry values. When fit with the 8.4 mm lens. For most eyes, fitting a flatter lens led to greater decentration, decreased comfort, and no increase in lens movement. The 8.4 mm lens was found to provide on "optimal" fit in over 60% of eyes tested and a fit of "good" or "better" in nearly 90% of eyes tested. Comparisons of different manufactures' lens found that similiar lenses do not always fit in the same way due to subtle design and production differences. Therefore, different products may require different base curve radii to fit the same patient. This is even true when water content, center thickness, and diameter are approximately the same. A praditioner fitting a new patient in this lenses should begin with the 8.4 mm base curve radius.

  • PDF

A Study for the Limitation of Measurement Accuracy and Reliability of Autostigmatic Null lens System by Adjustment and Fixing Process (조정방식과 경통고정방식에 대한 자동무수차점 널 렌즈 광학계의 측정 정밀도 한계 및 신뢰도)

  • Lee, Young-Hun;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.440-445
    • /
    • 2005
  • The limitation of measurement accuracy and reliability of autostigmatic null lens system are studied for the cases of using inter-distance of null lenses as the adjustment factor of alignment and fixing the distance by mounting. If we investigate the first case, the wavefront aberration of null lens system is compensated by the adjustment process even though the shape of aspherical surface is not properly fabricated. As the result, it brings about the problem of measurement reliability. However, for the fixing process by mounting null lenses, it doesn't cause the reliability problem because the wavefront aberration of null lens system is not compensated. Further, the fixing process shows nearly same result in measurement accuracy to the adjustment process, that is, $0.0316{\lambda}$ vs. $0.0326{\lambda}$. So, we can conclude the setup for autostigmatic null lens system must be constituted by means of the fixing process. Meanwhile, we introduce and define the alignment aperture on aspheircal mirror, which can be approximated as spherical zone for alignment of null lens system, and besides, we calculate the required fabrication accuracy of the zone for the necessary measurement accuracy.

One dimensional inhomogeneous aperture modulation effects on the MTF of optical system (일차원적 비균일 개구변조가 광학계 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.2
    • /
    • pp.59-62
    • /
    • 1998
  • One dimensional inhomogeneous aperture modulation effects on the MTF of optical system was investigated. The lens undertest was a doublet made in Korea. It was 10 mm effective diameter, 87.8 mm effective focal length. The ray-fans and spot diagrams were caluculated and presented on the picture for on-axis and off-axis (field of view, 1$^{\circ}$ and 2$^{\circ}$). Aperture modulation was carried out by positioning a aperture modulator close contacted with the lens undertest. We bought two modulators from Edmud Company in U.S.A. One was linear type and the other was stepped type. The MTFs were measured on the best of focus for unmodulated apertue where the MTF has the largest value for 60 c/mm and were compared with one another. The MTFs of modulated apertures had a little lower values than the MTF of unmodulated aperture for on-axis but in the case off-axis, the values are highly improved as much as the wider field of view by modulating on the aperture.

  • PDF

Studies on Protein Removing Activity of New Lens Cleaner

  • Jean Hyun;Park, Jong-Woo;Park, Kun-Hyock
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.275-275
    • /
    • 1996
  • Rudko method에 의한 단백질 제거능 시험 결과, 기존에 시판 중인 렌즈 세척제 보다 신규 처방화 된 렌즈 세척제의 단백질 제거능이 1.5배 이상 우수하였으며, 전자 주사 현미경 사진과 비교시 동일한 결과를 보임을 알 수가 있다.

  • PDF

Photochromic lens for patients with photophobia and estimation of clinical trial efficacy (광시증 환자를 위해 개발된 광변색렌즈와 임상 효과 평가)

  • Ha, Jin-Wook;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2005
  • Photochromic lens is the color changing lens from colorlessness to colorness when exposed to UV light. It can protect eyes from UV-B light which cause the cataract and can be used as sunglass in the summer since it can cut off 70~80% of sun light. Surface coating technique was used to develop lens which has 70% light transmittance and of which fading time of color change is within 5 min. Various color lenses were developed so that these had various color such as blue, green, brown, violet, yellow and red etc. Lens has an excellent physical properties, 100% adhesion and 4~5H hardness. The chemical and the scratch resistance of this lens were the greatest and the thermal stability was also higher. The clinical trial of developed lens were applied to 65 patients who had photophobia by various reasons at ophthalmology of Soonchunhyang University Hospital. Results showed that glaring was significantly reduced and the visual health were remarkably improved. Especially, anti-glaring effect in the night was great for the patient who had the LASIK operation. Protection of UV-B and blue light also can prevent the patient from cataract and the yellowish crystalline lens at old ages. Through the result of clinical. trial, we know that photochromic lens could be a new technique for both cure and precaution of photophobia.

  • PDF

Optical Assembly and Fabrication of a Micro-electron Column (마이크로 전자렌즈의 광학적 정렬과 조립)

  • Park, Jong-Seon;Jang, Won-Kweon;Kim, Ho-Seob
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.354-358
    • /
    • 2006
  • A silicon lens and an insulator of pyrex, components of a micro-electron column, should be assembled by aligning and stacking simultaneously. An optical alignment of a diffraction beam and a laser welding were employed for the assembly of a source lens and an Einzel lens with precision within $\pm$4% for the maximum aperture size. The experimental condition for optical alignment and laser welding are explained. Anodic bonding was used to assist in stacking lenses. A micro-electron column of smaller apertures assembled with precise alignment and fabrication was tested with a current image of a Cu grid of 9$\mu$m in linewidth, and showed a higher resolution in acceleration mode.

One dimensional inhomogeneous phase modulation effects on the MTF of an optical system (일차원적 비균일 위상변조가 광학계의 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.10-14
    • /
    • 1999
  • One dimensional inhomogeneous phase modulation effects on the MTF of optical system was investigated. The lens under test was a doublet made in Korea. It was 36 mm effective diameter, 128.04 mm effective focal length. The ray-fans and spot diagrams were calculated and presented on the picture for on-axis and off-axis (field of view, $1^{\circ}$ and $2^{\circ}$). Phase modulation was carried out by positioning a phase modulator close contacted with the lens under test. One was linear type that had linearly increasing phase retardation and the other was stepped type which had phase difference $\pi$ for each step. The MTFs were measured on the Gaussian image plane and were compared with one another. The MTFs of linear type phase modulated apertures had a little lower values than the MTF of unmodulated aperture for on-axis but most of all the MTFs of one dimensional phase modulated aperture are improved than the MTF of unmodulated aperture.

  • PDF