• Title/Summary/Keyword: 시편

Search Result 4,684, Processing Time 0.032 seconds

Effect of Stitching on Mechanical and Impact Properties of Glass Fiber Reinforced Composite (스티칭에 의한 유리섬유강화 복합재료의 물성 및 충격거동 변화)

  • Park, Jae-Yong;Kang, Tae-Jin;Yuk, Jong-Il
    • Korean Journal of Materials Research
    • /
    • v.2 no.5
    • /
    • pp.366-374
    • /
    • 1992
  • Mechanical and impact properties of stitched S2 glass fiber reinforced polyester woven laminates composites have been studied. Laminates were stitched using Kevlar 49 thread with 1/2, 1, and 2 inch stitch spacing. Tensile and 3-point bending tests haute been performed to evaluate the mechanical properties of stitched and unstitched laminates. Impact tests at applied energy of 234.7J were performed to examine the impact behavior and toughness changes of the specimen. The same specimens were also tested repeatedly at low impact energy level of 110.2J for 3 times to evaluate damage tolerance properties. The tensile and 3-point bending test results showed that one inch spacing specimen had the highest tensile and flexural strength. It also showed the highest energy absorption capability and the best damage tolerance property at the repeated impact test. The half inch spacing specimen showed the lowest tensile strength and energy absorption property at the impact energy level of 234.7J, even though it had the highest frequency of stitching thread.

  • PDF

AN IN-VITRO EVALUATION OF SEALER PLACEMENT METHODS IN SIMULATED ROOT CANAL EXTENSIONS (근관 내 불규칙 확장부에서 sealer 적용방법에 따른 충전 효과 평가)

  • Kim, Sung-Young;Lee, Mi-Jeong;Moon, Jang-Won;Lee, Se-Joon;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • The aim of this study was to evaluate the effectiveness of sealer placement in simulated root canal extensions. Forty resin blocks were attained from the Endo-training Bloc. In each block. The simulated root canal was made with $\#20$, 80taper GT file. After each block was longitudinally split into two halves, a standardized groove was prepared on one canal wall of two halves to simulate the canal extensions with various irregularities. The two halves of each block were assembled and all simulated root canals were obturated by single cone method with AH26 sealer. Four different methods of sealer placement were used: group A, $\#20$ K-file; group B, ultrasonic file; group C, lentulo spiral; group D, EZ-Fill bi-directional spiral. All obturated blocks were stored in $100\%$ humidity at $37^{\circ}C$ for 1 week, Using a low speed saw, each block was sectioned horizontally. Images of the sections were taken using a stereomicroscope at $\times$ 30 magnification and a digital camera. The amount of the sealer in the groove was evaluated using a scoring system, a higher score indicated better sealing effectiveness. The data was statistically analysed by Fisher's Exact Test. The sealing score was the lowest, specially at the middle area of canal extensions in group A, and that was statistically significant difference from other groups. In conclusion, the ultrasonic file, lentulo spiral and EZ-Fill bi-directional spiral were effective methods of sealer placement in simulated canal extensions. The K file was the least effective method, specially at the middle area of canal extensions.

Strength Analysis of 3D Concrete Printed Mortar Prism Samples (3D 콘크리트 프린팅된 모르타르 프리즘 시편의 강도 분석)

  • Kim, Sung-Jo;Bang, Gun-Woong;Han, Tong-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.4
    • /
    • pp.227-233
    • /
    • 2022
  • The 3D-printing technique is used for manufacturing objects by adding multiple layers, and it is relatively easy to manufacture objects with complex shapes. The 3D concrete printing technique, which incorporates 3D printing into the construction industry, does not use a formwork when placing concrete, and it requires less workload and labor, so economical construction is possible. However, 3D-printed concrete is expected to have a lower strength than that of molded concrete. In this study, the properties of 3D-printed concrete were analyzed. To fabricate the 3D-printed concrete samples, the extrusion path and shape of the samples were designed with Ultimaker Cura. Based on this, G-codes were generated to control the 3D printer. The optimal concrete mixing proportion was selected considering such factors as extrudability and buildability. Molded samples with the same dimensions were also fabricated for comparative analysis. The properties of each sample were measured through a three-point bending test and uniaxial compression test, and a comparative analysis was performed.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

Characteristics of Antibacterial Chlorhexidine-Containing Hydroxyapatite Coated on Titanium (타이타늄 상에 코팅된 클로르헥시딘 항균제를 함유한 수산화인회석의 특성)

  • Kim, Min-Hee;Hwang, Moon-Jin;Lee, Woon-Young;Park, Yeong-Joon;Song, Ho-Jun
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.263-272
    • /
    • 2017
  • In this study, antibacterial chlorhexidine (CHX)-containing hydroxyapatite (HAp) was coated on titanium and investigated its characteristics. Ti-mSBF-CHX group was prepared by soaking titanium disks in the modified simulated body fluid (mSBF) mixed with CHX. Ti-mSBF group was coated using mSBF without CHX. Ti-mSBF-adCHX group was prepared by soaking Ti-mSBF specimen in CHX-containing solution. The crystallines clusters composed with nano-shaped crystallites were coated on the surface of the Ti-mSBF specimen. The ribbon-shaped crystallites were observed with the crystalline clusters on the Ti-mSBF-CHX specimen. The content of CHX chemical compositions was high in ribbon-shaped crystallites. HAp crystalline structure was dominant for all prepared specimens, and ${\beta}-TCP$ (tricalcium phosphate) and OCP (octacalcium phosphate) crystalline structures were observed in the Ti-mSBF-CHX specimen. FT-IR spectra showed the strong peaks of CHX in Ti-mSBF-adCHX and Ti-mSBF-CHX groups. However, after immersing in a phosphate buffered saline (PBS), CHX was rapidly released in Ti-mSBF-adCHX group, while it was slowly released in Ti-mSBF-CHX. We expect that the coating method of Ti-mSBF-CHX group could be used for protecting inflammation of titanium implant by incorporating antibacterial agent CHX into HAp layer.

Preparation of shotcrete coarse aggregate with low grade clay and coal ash (저급 점토와 석탄회를 이용한 숏크리트용 골재의 제조)

  • Kim, Kyung-Nam;Jung, Hee-Su;Park, Hyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.3
    • /
    • pp.147-152
    • /
    • 2010
  • In this study, the artificial coarse aggregate was manufactured by using coal ash and low grade clay. The characteristics of a coal ash-clay system were investigated using XRD, XRF, TG-DTA, SEM and Dilatometer with various coal ash contents. The chemical compositions are the fly ash, bottom ash and clay, $Al_2O_3$ are 28.5 wt%, 32.4 wt% and 18.1 wt%, and $SiO_2$ are 33.0 wt%, 53.7 wt% and 68.4 wt% in weight ratio, respectively. The shrinkage of specimens started at around $850^{\circ}C$ and changed little up to $1100^{\circ}C$, but increased markedly at above $1100^{\circ}C$. The shrinkage rate is strongly related to the decarbonization amount of coal ash. At the sintering temperature $1150^{\circ}C$, it was found that quartz, mullite, anorthite and albite phase exist in all specimens. It was found that bottom-clay system specimen sintered at $1150^{\circ}C$ had a good compressive strength of 87.5 kg/$cm^2$, and the compressive strength of bottom-clay specimen was higher than that of fly-clay system specimen. The reusability of coal ash as a raw material in the process of shotcrete resources such as artifical coarse aggregate is highly expected.

비증착 방법에 의한 사용후 핵연료의 EPMA 분석

  • 정양홍;송웅섭;김도식;김희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.353-354
    • /
    • 2004
  • 사용후 핵연료의 조성을 분석하거나 또는 반사전자상과 2차 전자상 등으로 시료를 관찰하기 위해서는 핫셀(Hot cell)에 증착기(coater)를 설치하여 시료표면을 전도성 물질인 탄소 등으로 증착시켜야 한다. 그러나 원격조정기를(manipulator)를 이용하여 수행되는 핫셀에서의 증착작업은 사용후 핵연료 시험의 선진분석기술을 갖고 있는 원자력 선진국에서도 핫셀내에 설치되어 있는 증착기의 탄소봉을 교체하는 작업과 진공장치의 성능 유지가 까다로워 시료표면에 균질하게 전도성 물질을 증착시키는 작업에 많은 어려움을 겪고 있다. 본 연구는 통상적으로 이용되는 증착기를 사용하지 않고 Silver Paint를 사용하여 사용후 핵연료를 분석할 수 있는 새로운 방법에 대한 연구를 수행하였다. 산화물 핵연료는 전기전도도가 매우 낮아($3{\times}10^{-1}~4{\times}10^{-8}/ohm{\cdot}cm$)입사된 전자의 이동이 원활하지 못해 일어나는 들뜸(Charging)현상이 발생한다. 그러나 Silver Paint 에 사용후 핵연료를 접착하면 모세관(capillary)현상에 의해 시료 주위와 핵연료의 결정립계로 Silver가 스며들어 입사된 전자의 이동이 원활해져 전도성이 극히 낮은 시료의 분석이 가능하게 된다. 본 시험에 사용된 EPMA는 (Electron Probe Micro Analyzer, SX-50R, CAMECA, Paris, France) 고 방사능을 띤 조사 핵연료의 시험을 수행할 수 있도록 기기의 적절한 부위에 납과 텅스텐으로 차폐되어 시편의 방사능 세기가 $3{\times}10^{10}Bq$까지 시험 가능한 기기이다. 그림 1은 JAERI 에 설치 운영중인 증착기 설비 사진이다. 그림에서 핫셀에 설치된 증착기의 진공을 유지하기 위해 핫셀 벽을 관통하여 증착기 본체까지 연결된 배출관의 형상과 복잡한 주변장치들을 볼 수 있다. 그림 2는 비조사 핵연료 시편을 Silver Pain떼 접착한 사진이다. 그림은 시료주위와 시료 표면까지 Silver Paint가 도포된 모습을 보여주고 있다. 상용발전소에서 연소도가 50,000 Mwd/tU인 사용후 핵연료를 상기와 같은 방법으로 만든 시편의 표면을 관찰한 사진을 그림 3~8에 나타내었다. 그림 3은 핵연료 중앙부위의 결정립을 나타낸 그림이다. Silver Paint만으로 접착한 시료의 표면관찰 및 정량분석이 그림에서 보듯이 가능함을 확인하였다. 그림 4는 사용후 핵연료시료를 중앙부위에서 가장자리까지를 다섯 부위로 나누어 그 중 중앙부위(1/5) 지점의 입계 및 형상을 관찰한 사진이다. 결정립의 크기가 다른 부위보다 상대적으로 크고, 결정립에 생성된 기공이 발달되어 있음을 볼 수 있다. 그림 5와 6과 7은 중심부위와 rim부위 사이 지점을 관찰한 사진으로서 결정립과 기공의 분포가 비슷한 형상을 나타내고 있음을 관찰할 수 있었다. 그림 8은 rim 부위 사진으로 전형적인 rim 영역 현상을 관찰할 수 있었다. 표 1은 그림 2와 같이 비조사 산화물 핵연료를 Silver Paint로 접착한 시편을 정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.

  • PDF