• Title/Summary/Keyword: 시스템 히트펌프

Search Result 373, Processing Time 0.024 seconds

Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System (주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구)

  • Kang, Eun-Chul;Min, Kyoung-Chon;Lee, Kwang-Seob;Lee, Euy-Joon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2016
  • Heat pump unit performance is represented by the COP(Coefficient of Performance) and expressed by the one point design condition according to KS C 9306. However, when heat pump operated to the real buildings, the simulations are changed continuously according to the actual weather conditions, the building load and heat pump source conditions. The purpose of this paper is to evaluate the APF(Annual performance factor) for a climate dependent building integrated air-to-air heat pump system in major cities in Korea. TRNSYS simulation tool with an international MV standard based IPMVP 4.4.2 was utilized to perform the annual performance analysis. The APF with the multi-performance data based method was calculated as 2.29 for Daejeon residential building case while Busan residential building case appeared as the highest with 2.36.

Performance characteristics of the Coil Deposition Type Heat Pump using Geothermal Energy (지열을 이용한 코일 침적형 히트펌프의 성능 특성)

  • Oh, Hoo-Kyu;Lee, Dong-Gun;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.437-444
    • /
    • 2012
  • This paper describes the experimental characteristics on cooling and heating performance of the coil deposition type heat pump using geothermal energy to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling degree, evaporation and condensation temperature in the coil deposition type heat pump using geothermal energy. The main results are summarized as follows : As the evaporation temperature and subcooling degree of the coil deposition type heat pump using geothermal energy increases, and the condensation temperature decreases, the COP of this system increases. The subcooling degree, evaporation and condensation temperature of the coil deposition type heat pump have an effect on cooling and heating COP of this heat pump. Therefore, it is a necessary to determine the optimum operation conditions for the highest COP of this heat pump presented in this study.

빙축열 및 히트펌프시스템 전문회사 '그들에게는 뭔가 특별한 것이 있다.'

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.23
    • /
    • pp.28-29
    • /
    • 2003
  • 폐열을 이용한 히트펌프시스템은 에너지절감효과는 냉방시 $45\%$, 난방시 $75\%$, 급탕부하시 $67\%$정도이어서 가히 타의추종을 불허한다. 한국적 상황을 고려한 국내 최초의 폐열이용 히트펌프시스템이 될 이 사업의 투자비회수기간은 2.5년에 불과해 향후 휴양 및 숙박시설 등지에 큰 관심을 끌 것으로 최사장은 기대하고 있다.

  • PDF

멀티히트펌프 시스템의 보급현황 및 산업발전기여도

  • Kim, Yong-Chan;Heo, Jae-Hyeok
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.11
    • /
    • pp.11-16
    • /
    • 2010
  • 멀티히트펌프 시스템의 시장동향 및 기술동향을 분석하고 향후 경제적, 기술적 파급효과 등을 예측하여 멀티히트펌프 시스템의 산업발전기여 효과를 소개하고자 한다.

  • PDF

Performance Simulation of Geothermal Heat Pump (GHP) System with Different Control Schemes (제어 방식에 따른 지열 히트펌프 시스템의 성능 시뮬레이션)

  • Lee, Doo-Young;Choi, Jae-Ho;Min, Kyong-Chon;Sohn, Byonghu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.35-41
    • /
    • 2016
  • Geothermal heat pump (GHP) systems have been proved to be one of the most efficient systems for heating and cooling in buildings. However, an optimal energy performance depends on a good control of the system components, including heat pumps and circulation pumps, which affect to the total energy consumption of system. This paper presents the simulation results of the heat pump performance for two different control schemes, i.e. constant setting temperature (Control-A) and variable setting temperatures (Control-B) in buffer tank. A dynamic simulation tool, TRNSYS 17, was used to model the entire system and to assess the performance of the system. Simulation results show that the Control-B, which controls the temperature in buffer tank with outdoor air temperature, is a effective way to reduce the energy consumptions in heat pump (7.7%) and circulation pump (7.5%).

Status of GSHP System Development (지열원 열펌프 시스템 기술 연구 현황 및 현안)

  • Lee, Euy-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1238-1243
    • /
    • 2006
  • 최근 열펌프 시스템 설치가 해마다 평균 10-30% 정도 꾸준히 증가하고 있다. IEA HP Annex 28, 29('열펌프 성능평가 기술', '열펌프 시장 현황 현안')등 국제공동연구를 통한 꾸준한 지열원 열펌프 시스템 응용분야의 발전은 기존의 지열원 시스템에 비해 비용과 더불어 보다 많은 에너지 절감효과를 가져왔다. 지열기술의 성공적 사용여부는 기술의 견실함, 설계기술의 개발, 기반시설설치, 히트펌프와 부품제조업자의 반응에 기인한다. 최근 주요 연구동향은 토양열전도 측정, 지열히트펌프 시스템 전주기 성능평가, 하이브리드 시스템의 초기비용 절감과 이러한 열펌프 시스템 설계방법분야 개발에 대해 초점이 맞춰지고 있다. 본 기술현안 보고서는 최근 국내외 연구동향을 정리하여 본다.

  • PDF

멀티히트펌프 시스템의 동계 전력피크 기여도 분석

  • Jang, Yeong-Su;Gang, Byeong-Ha
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.11
    • /
    • pp.17-21
    • /
    • 2010
  • 고효율 난방기기인 멀티히트펌프의 소비전력분석을 통해, 멀티히트펌프 보급이 동계 전력피크에 미치는 영향을 분석한다.

  • PDF

Actual operation characteristics to evaluate the performance of heat pump outdoor unit in the constant temperature chamber (항온챔버에서 히트펌프 실외기의 성능을 평가하는 실제 운전)

  • Jong-Ryeol Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.3
    • /
    • pp.123-128
    • /
    • 2022
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. In order to conduct a study that does not cause frost on the outdoor unit of the heat pump regardless of the season, a constant temperature chamber like a general room that can be tested under the same conditions as in the natural state was built. The experiment was conducted by providing an environment similar to the natural state to the outdoor unit of the heat pump installed in the constant temperature chamber. As a result, the lower the outdoor temperature, the lower the efficiency of the heat pump. It wat confirmed that the lower the value, the longer it is.

A Study on Horizontal Ground Source Heat Pump Systems (수평형 지열원 히트펌프 시스템에 관한 연구)

  • Park, Yong-Jung;Kim, Kyoung-Hoon
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.160-165
    • /
    • 2006
  • Ground source heat pump (GSHP) or geothermal heat pump systems (GHPs) are recognized to be outstanding heating and cooling systems. Most of GSHP systems installed and studied in korea are vertical GSHP systems. A horizontal GSHP system was installed in greenhouse and investigated for the performance characteristics. The results of the study showed that the heating coefficient of performance of the heat pump was 3.64 and the overall heating coefficient of performance of the system was 3.31. The pumping power was obtained as 28.0 W/kW and the required ground heat exchanger length was 53.3 m/kW of rejection heat of condenser. The heat extraction rate was, on average, 14.58 W/m of ground heat exchanger length and trench length is 27.7 m/kW of rejection heat of condenser.

고효율 멀티히트펌프를 위한 평가기술

  • Choe, Jun-Yeong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.11
    • /
    • pp.27-32
    • /
    • 2010
  • 멀티히트펌프 시스템의 시장동향 및 기술동향을 분석하고 향후 경제적, 기술적 파급효과 등을 예측하여 멀티히트펌프 시스템의 산업발전기여 효과를 소개하고자 한다.

  • PDF