• Title/Summary/Keyword: 시스템형상

Search Result 2,461, Processing Time 0.03 seconds

Nonlinear Earthquake Response Analysis of a Soil-Structure Interaction System Subjected to a Three-Directional Ground Motion (3축 방향 지반운동이 작용하는 지반-구조물 상호작용계의 비선형 지진응답 해석)

  • Lee, Jin Ho;Kim, Jae Kwan;Kim, Jung Han
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.4
    • /
    • pp.317-325
    • /
    • 2016
  • In this study, nonlinear earthquake responses of a soil-structure interaction(SSI) system which is subjected to a three-directional ground motion are examined. The structure and the near-field region of soil, where the geometry is irregular, the material properties are heterogeneous, and nonlinear dynamic responses are expected, are modeled by nonlinear finite elements. On the other hand, the infinite far-field region of soil, which has a regular geometry and homogeneous material properties and dynamic responses is assumed linearly elastic, is represented by three-dimensional perfectly matched discrete layers which can radiate elastic waves into infinity efficiently. Nonlinear earthquake responses of the system subjected to a three-directional ground motion are calculated with the numerical model. It is observed that the dynamic responses of a SSI system to a three-directional motion have a predominant direction according to the characteristics of the ground motion. The responses must be evaluated using precise analysis methods which can consider nonlinear behaviors of the system accurately. The the method employed in this study can be applied easily to boundary nonlinear problems as well as material nonlinear problems.

Aerodynamic Design and Numerical Study of a Propane-Refrigerant Centrifugal Compressor for LNG Plant (LNG 플랜트용 프로판 냉매 원심압축기의 공력설계 및 전산해석적 연구)

  • Park, Joo-Hoon;Lee, Won-Suk;Shin, You-Hwan;Kim, Kwang-Ho;Lee, Yoon-Pyo;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.781-787
    • /
    • 2011
  • We design a four-stage propane-refrigerant centrifugal compressor for an LNG plant. Using a commercial code, we aerodynamically designed the compressor at each design point of the corresponding stages. We estimated the one-dimensional aerodynamic design output and the three-dimensional shape of the impeller flow passage via three-dimensional flow analysis. In particular, we discuss in detail the flow characteristics of the impeller and the vaneless diffuser passages of the fourth-stage compressor in terms of the velocity fields, the pressure, and the entropy distributions of the flow passages. We include the flow effects of the tip clearance flow, because at this stage the rotating speed and total inlet pressure are higher than those at the other compressor stages are. We carried out performance tests of the designed compressor stages using propane as a refrigerant in the LNG cycle. The practical evaluation could lead to design enhancements in the future.

A Study on the Measurement of Axial Cracks in the Magnetic Flux Leakage NDT System (자기누설 비파괴 검사 시스템에서 축방향 미소결함 측정에 관한 연구)

  • Kim, Hui-Min;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu;Koo, Sung-Ja
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • From among the NDT (Non-Destructive Testing) methods, the MFL (Magnetic Flux Leakage) PIG (Pipeline Inspection Gauge) is especially suitable for testing pipelines because the pipeline has high magnetic permeability. MFL PIG showed high performance in detecting the metal loss and corrosions. However, MFL PIG is difficult to detect the crack which occured by exterior-interior pressure difference in pipelines and the shape of crack is very long and narrow. Therefore, the new PIG is needed to be researched and developed for detecting the cracks. The CMFL (Circumferential MF) PIG performs magnetic fields circumferentially and can maximize the magnetic flux leakage at the cracks. In this paper, CMFL PIG is designed and the distribution of the magnetic fields is analyzed by using 3 dimensional nonlinear finite element method (FEM). By Simulating and Measuring the magnetic leakage field, it is possible to detect of axial cracks in the pipeline.

Three-Dimensional Resistivity Modeling by Serendipity Element (Serendipity 요소법에 의한 전기비저항 3차원 모델링)

  • Lee, Keun-Soo;Cho, In-Ky;Kang, Hye-Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.1
    • /
    • pp.33-38
    • /
    • 2012
  • A resistivity method has been applied to wide range of engineering and environmental problems with the help of automatic and precise data acquisition. Thus, more accurate modeling and inversion of time-lapse monitoring data are required since resistivity monitoring has been introduced to quantitatively find out subsurface changes With respect to time. Here, we used the finite element method (FEM) for 3D resistivity modeling since the method is easy to realize complex topography and arbitrary shaped anomalous bodies. In the FEM, the linear elements, also referred to as first order elements, have certain advantages of simple formulation and narrow bandwidth of system equation. However, the linear elements show the poor accuracy and slow convergence of the solution with respect to the number of elements or nodes. To achieve the higher accuracy of finite element solution, high order elements are generally used. In this study, we developed a 3D resistivity modeling program using high order Serendipity elements. Comparing the Serendipity element solutions for a cube model with the linear element solutions, we assured that the Serendipity element solutions are more accurate than the linear element solutions in the 3D resistivity modeling.

Experimental Performance Evaluation on V-shaped Butt Welding Using GMA Welding Double Wire Reel and Remote Control Torch Welding Technique (GMAW 더블 와이어 릴, 원격제어토치 용접기술을 이용한 V형 맞대기 용접 부의 실험적 성능 평가)

  • Kim, Jeong-Hyeok;Oh, Seck-Hyeog;Lee, Hae-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1339-1347
    • /
    • 2015
  • This study discusses a remote control torch system equipped with a GMAW double wire reel. The welding machine is 30m away from the wire feeder at the industrial site and the feeder is three to five meters away from the torch. Accordingly, the welders cannot control the current and voltage that meets the welding condition during work when they are working at a place that prevents them from seeing the control panel, such as inside a vehicle or tank or at a far work site. They also have no choice but to stop working to change the wire reel when it is burned out completely. Such work suspension resulting from frequent moves to adjust the current and voltage as well as to replace the wire and subsequent cooling causes welding defects. This study produced a remote control torch equipped with a double wire reel by simplifying and streamlining the existing GMAW functions to reduce the troubling issue. The remote control torch equipped with a double wire reel and the existing $CO_2$ /MAG welding torch were applied as a V-groove butt in the vertical position using 6mm rolled steel for a SM50A welding structure. After welding, the condition of welded surface beads underwent a visual inspection and radiographic inspection to analyze the welding quality inside the welded part. This study also evaluated the reduction of welding defects, cost saving, the replacing performance against the existing commercial welders, and the effects on possible compatibility.

Evaluation on Expectation of Deflection of Floor Damping Materials Subjected to Long-Term Load (장기하중을 받는 바닥완충재의 처짐 예측 평가)

  • Kim, Jung-Min;Hong, Yoon-Ki;Kim, Jin-Koo;Lee, Jung-Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.19-26
    • /
    • 2016
  • Floor damping materials used in floating floor system to diminish the floor noise have been made with low density and dynamic stiffness. Owing to this low density and dynamic stiffness, the deflection in these materials under long-term loading and cracking of the floor finishing mortar in the floating floor system may occur. This paper presents the results of long-term loading effects on the deflection of different types of floor damping materials. The experimental program involved the long-term loading tests for 490 days loading period on sixteen specimens. Specimens were classified as DM1(Damping Materials) to DM8, depending upon the four main parameters; types, bottom shapes and densities of floor damping materials and amount of loading. Results indicated that the long-term deflection of all specimens of damping materials remained unchanged after 200 days at all loading amounts, except the specimens made up of Polystrene, in which long-term deflection remained unchanged after 160 days at 250 N load and 100 days 500 N load. In this paper, two types of correlation expressions were shown in the deflection range prior to the range where deflection remained constant; two analyses by ISO 20392 and linear regression. In comparison of two analyses and experimental results on the difference of deflection of 16 specimens, the difference of deflection was below 0.4 mm in those analyses in case of that total deflection was below 10 mm. Restrictively, it was judged that the analysis for the deflection of specimens made up of Polystrene is more appropriate using ISO 20392.

Design Concept of Beams Reinforced by Deformed Bars and Non-Prestressed Strands in Combination (비긴장강연선과 철근이 혼용된 보의 설계방안)

  • Noh, Sam-Young;Jo, Min-Joo;Kim, Jong-Sung;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.18-29
    • /
    • 2013
  • A new precast concrete (PC) beam and column connection system using non-prestressed wire strands was recently developed. The system is composed of one unit of two-storied PC-column and PC-beams with U-shaped ends. The connection part of the column and beams is reinforced by deformed bars and non-prestressed wire strands in combination for the improvement of workability. Structural performance of this system was verified by several experimental studies. The purpose of this study is developing a design concept of the beam reinforced by deformed bars and non-prestressed wire strands in combination, in terms of the cross-sectional analysis, based on the preceded experiment. A minimum and maximum reinforcement ratio and the calculation formula for the strength of flexural member reinforced by reinforcements having different yield strengths are derived based on KBC2009. Under consideration existing research results for the application of high strength reinforcement bars, the design yield strength of the non-prestressed wire strand is suggested. An example for the cross section design, satisfying the serviceability requirements, demonstrates the applicability of the design concept developed in the study.

Analysis of Factors Affecting the Hygroscopic Performance of Thermally Treated Pinus koraiensis Wood (잣나무열처리재의 흡방습성능에 미치는 영향인자 분석)

  • Chang, Yoon-Seong;Han, Yeon-Jung;Eom, Chang-Deuk;Park, Joo-Saeng;Park, Moon-Jae;Choi, In-Gyu;Yeo, Hwan-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.1
    • /
    • pp.10-18
    • /
    • 2012
  • A high airtightness is required for the residential spaces constructed recently to save cooling and heating energy through improving insulation performance. Because the chances to release steam formed by human activity in building and inflow of water vapor in outdoor air to residential space are reduced, the natural humidity control performance of interior materials has become more important. In this study, hygroscopic performance of thermo-physically treated wood (Pinus koraiensis) was estimated. At various relative humidity condition, the water vapor adsorption and desorption rates of wooden materials were measured as well as equilibrium moisture content. Effects of roughness and surface microstructure as physical factors and functional groups as chemical factors on the hygroscopicity were analyzed. It is expected that the results from this study and further study of measuring moisture generation in residential spaces could contribute to install a system for evaluating the hygrothermal performance of wooden building.

고효율 태양전지를 위한 ICP-RIE기반 결정질 실리콘 표면 Texturing 공정연구

  • Lee, Myeong-Bok;Lee, Byeong-Chan;Park, Gwang-Muk;Jeong, Ji-Hui;Yun, Gyeong-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.315-315
    • /
    • 2010
  • 결정질 실리콘을 포함하는 태양전지의 광전효율은 표면에 입사되는 태양광의 반사를 제외하면 흡수된 광자에 의해 생성되는 전자-정공쌍의 상대적인 비율인 내부양자효율에 의존하게 된다. 실제 생성된 전자-정공쌍은 기판재료의 결정상태와 전기광학적 물성 등에 의해 일부가 재결합되어 2차적인 광자의 생성이나 열로서 작용하고 최종적으로 전자와 정공이 완전히 분리되고 전극에 포집되어 실질적인 유효전류로 작용한다. 16% 이상의 고효율 결정질 실리콘 태양전지양산이 요구되고 있는 현실에서 광전효율 개선 위해 가장 우선적으로 고려되어야 할 변수는 입력 태양광스펙트럼에 대한 결정질 실리콘 표면반사율을 최소화하여 광흡수를 극대화하는 것이라 할 수 있다. 이의 해결을 위하여 대기와 실리콘표면 사이의 굴절률차이가 크면 클수록 태양광스펙트럼에 대한 결정질 실리콘의 광반사는 증가하기 때문에 상대적으로 낮은 굴절률의 $SiO_x$$SiN_x$와 같은 반사방지막을 광입력 실리콘표면에 증착하여 광반사율 저감공정을 적용하고 있다. 이와 더불어 결정질 실리콘표면을 화학적으로 혹은 플라즈마이온으로 50-100nm 직경의 바늘형 피라미드형상으로 texturing 함으로 광자들의 다중반사 등에 기인하는 광흡수율의 증가를 기대할 수 있기 때문에 태양전지효율 개선에 긍정적인 영향을 미치는 것으로 이해된다. 본 실험에서도 고효율 다결정 실리콘 태양전지 양산공정에 적용 가능한 ICP-RIE기반 결정질 실리콘표면에 대한 texturing 공정기술을 연구하였다. Double Langmuir 플라즈마 진단시스템(DLP2000)을 적용하여 사용한 $SF_6$$O_2$ 개스유량과 챔버압력, 플라즈마 파워에 따른 이온밀도, 전자온도, 포화이온전류밀도, 플라즈마포텐셜의 공간분포를 모니터링하였고 texturing이 완료된 시료에 대하여 A1.5G 표준태양광스펙트럼의 300-1100nm 파장대역에서 반사율을 측정하여 그 변화를 관찰하였다. 본 연구에서 얻어진 결과를 간략히 정리하면 Si texturing에 가장 적합한 플라즈마파워는 100W, $SF_6/O_2$ 혼합비는 18:22, 챔버압력은 30mtorr 등이고 이에 상응하는 플라즈마의 이온밀도는 $2{\sim}3{\times}10^8\;ions/cm^3$, 전자온도는 14~15eV, 포화전류밀도는 $0.014{\sim}0.015mA/cm^2$, 플라즈마포텐셜은 38~39V 범위 등이었다. 현재까지 얻어진 최소 평균반사율은 14.2% 였으며 최적의 texturing패턴 플라즈마공정 조건은 이온에 의한 Si표면원자들의 스퍼터링과 화학반응에 의한 증착이 교차하는 플라즈마 에너지 및 밀도 상태인 것으로 해석된다.

  • PDF

Theoretical Seismic Analysis of Butterfly Valve for Nuclear Power Plant (원자력 발전소용 버터플라이밸브의 내진해석)

  • Han, Sang-Uk;Ahn, Jun-Tae;Lee, Kyung-Chul;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1009-1015
    • /
    • 2012
  • Valves are one of the most important components of a pipeline system in a nuclear power plant, and it is important to ensure their structural safety under seismic loads. A crucial aspect of structural safety verification is the seismic qualification, and therefore, an optimal shape design and experimental seismic qualification is necessary in case the configuration of the valve parts needs to be modified and their performance needs to be improved. Recently, intensive numerical analyses have been performed before the experimental verification in order to determine the appropriate design variables that satisfy the performance requirements under seismic loads. In this study, static and dynamic numerical structural analyses of a 200A butterfly valve for a nuclear power plant were performed according to the KEPIC MFA. The result of static analysis considering an equivalent static load under SSE condition gave an applied stress of 135 MPa. In addition, the result of dynamic analysis gave an applied stress of 183 MPa, where the CQC method using response spectrums was taken into account. These values are under the allowable strength of the materials used for manufacturing the butterfly valve, and therefore, its structural safety satisfies the requirements of KEPIC MFA.