• Title/Summary/Keyword: 시스템에 의한 모의실험

Search Result 298, Processing Time 0.024 seconds

On Adaptive Narrowband Interference Cancellers for Direct-Sequence Spread-Spectrum Communication Systems (주파수대역 직접 확산 통신시스템에서 협대역 간섭 신호 제거를 위한 적응 간섭제거기에 관한 연구)

  • 장원석;이재천
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10C
    • /
    • pp.967-983
    • /
    • 2003
  • In wireless spread-spectrum communication systems utilizing PN (pseudo noise) sequences, a variety of noise sources from the channel affect the data reception performance. Among them, in this paper we are concerned with the narrowband interference that may arise from the use of the spectral bands overlapped by the existing narrowband users or the intentional jammers as in military communication. The effect of this interference can be reduced to some extent at the receiver with the PN demodulation by processing gain. It is known, however, that when the interferers are strong, the reduction cannot be sufficient and thereby requiring the extra use of narrowband interference cancellers (NIC's) at the receivers. A class of adaptive NIC's are studied here based on different two cost functions. One is the chip mean-squared error (MSE) computed prior to the PN demodulation and used in the conventional cancellers. Since thses conventional cancellers should be operated at the chip rate, the computational requirements are enormous. The other is the symbol MSE computed after the PN demodulation in which case the weights of the NIC's can be updated at a lot lower symbol rate. To compare the performance of these NIC's, we derive a common measure of performance, i.e., the symbol MSE after the PN demodulation. The analytical results are verified by computer simulation. As a result, it is shown that the cancellation capability of the symbol-rate NIC's are similar or better than the conventional one while the computational complexity can be reduced a lot.

Feasibility study of the usefulness of SRS thermoplastic mask for head & neck cancer in tomotherapy (두경부 종양의 토모치료 시 정위적방사선수술 마스크의 유용성 평가에 대한 연구)

  • Jeon, Seong Jin;Kim, Chul Jong;Kwon, Dong Yeol;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.355-362
    • /
    • 2014
  • Purpose : When head&neck cancer radiation therapy, thermoplastic mask is applied for patients with fixed. The purpose of this study is to evaluate usefulness of thermoplastic mask for SRS in tomotherapy by conparison with the conventional mask. Materials and Methods : Typical mask(conventional mask, C-mask) and mask for SRS are used to fix body phantom(rando phantom) on the same iso centerline, then simulation is performed. Tomotherapy plan for orbit and salivary glands is made by treatment planning system(TPS). A thick portion and a thin portion located near the treatment target relative to the mask S-mask are defined as region of interest for surface dose dosimetry. Surface dose variation depending on the type of mask was analyzed by measuring the TPS and EBT film. Results : Surface dose variation due to the type of mask from the TPS is showed in orbit and salivary glands 0.65~2.53 Gy, 0.85~1.84 Gy, respectively. In case of EBT film, -0.2~3.46 Gy, 1.04~3.02 Gy. When applied to the S-mask, in TPS and Gafchromic EBT3 film, substrantially 4.26%, 5.82% showed maximum changing trend, respectively. Conclusion : To apply S-mask for tomotherapy, surface dose is changed, but the amount is insignificant and be useful when treatment target is close critical organs because decrease inter and intra fractional variation.

Performance of Time-averaging Channel Estimator for OFDM System of Terrestrial Broadcasting Channel (지상파 방송 채널에서 OFDM 시스템의 시간 평균 채널 추정기의 성능)

  • 문재경;오길남;박재홍;하영호;김수중
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.44-53
    • /
    • 1999
  • In this paper, we propose a pilot based time-averaging channel estimation method and analyze error performances for efficient transmission of OFDM(Orthogonal Frequency Division Multiplexing) in multipath fading environment. Frequency domain channel estimations have been used in OFDM systems to compensate signal distortions due to fading on each subcarrier. The frequency domain estimation scheme uses scattered pilot to estimate channel response by simple interpolation. This implies that the estimated channel response includes signal distortions due to the noise. In this paper, we propose time-averaged channel estimation method to remove the distortion by noise. The proposed scheme can effectively remove noise components by taking time-average of the estimated channel response after estimating frequency domain channel. The computer simulations were performed to evaluate the performance of the proposed channel estimator. For the Rician channel, we compared the performance of the proposed method to that of a conventional one using channel estimation by gaussian interpolation when SER(Symbol Error Rate) = $10^{-4}$, and compared to perfect channel estimation case. The proposed method showed differences of 0.07 dB, 0.6 dB compared to perfect channel estimation and improvements of 1.7 dB, 1.9 dB for 16 QAM, 64 QAM respectively compared to conventional method.

  • PDF

On-line Fundamental Frequency Tracking Method for Harmonic Signal and Application to ANC (조화신호의 실시간 기본 주파수 추종 방법과 능동소음제어에의 응용)

  • Kim, Sun-Min;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.263-268
    • /
    • 2000
  • In this paper, a new indirect feedback active noise control (ANC) scheme based on the fundamental frequency estimation is proposed for systems with a harmonic noise. When reference signals necessary for feedforward ANC configuration is difficult to obtain, the conventional ANC algorithms for multi-tonal noise do not measure the reference signals but generate them with the estimated frequencies. However, the beating phenomena, in which certain frequency components of the noise vanish intermittently, may make the adaptive frequency estimation difficult. The confusion in the estimated frequencies due to the beating phenomena makes the generated reference signals worthless. The proposed algorithm consists of two parts. The first part is a reference generator using the fundamental frequency estimation and the second one is the conventional feedforward control. We propose the fundamental frequency estimation algorithm using decision rules, which is insensitive to the beating phenomena. In addition, the proposed fundamental frequency estimation algorithm has good tracking capability and lower variance of frequency estimation error than that of the conventional cascade ANF method. We are also able to control all interested modes of the noise, even which cannot be estimated by the conventional frequency estimation method because of the poor SIN ratio. We verify the performance of the proposed ANC method through simulations for the measured cabin noise of a passenger ship and the measured time-varying engine booming noise of a passenger vehicle.

  • PDF

Active Control of Harmonic Signal Based on On-line Fundamental Frequency Tracking Method (실시간 기본주파수 추종방법에 근간한 조화 신호의 능동제어)

  • 김선민;박영진
    • Journal of KSNVE
    • /
    • v.10 no.6
    • /
    • pp.1059-1066
    • /
    • 2000
  • In this paper. a new indirect feedback active noise control (ANC) scheme barred on the fundamental frequency estimation is proposed for systems with a harmonic noise. When reference signals necessary for feedforward ANC configuration are difficult to obtain, the conventional ANC algorithms for multi-tonal noise do not measure the reference signals but generate them with the estimated frequencies.$^{(4)}$ However, the beating phenomena, in which certain frequency components of the noise vanish intermittently, may make the adaptive frequency estimation difficult. The confusion in the estimated frequencies due to the beating phenomena makes the generated reference signals worthless. The proposed algorithm consists of two parts. The first part is a reference generator using the fundamental frequency estimation and the second one is the conventional feedforward control. We propose the fundamental frequency estimation algorithm using decision rules. which is insensitive to the beating phenomena. In addition, the proposed fundamental frequency estimation algorithm has good tracking capability and lower variance of frequency estimation error than that of the conventional cascade ANF method.$^{(4)}$ We are also able to control all interested modes of the noise, even which cannot be estimated by the conventional frequency estimation method because of the poor S/N ratio. We verify the performance of the proposed ANC method through simulations for the measured cabin noise of a passenger ship and the measured time-varying engine booming noise of a passenger vehicle.

  • PDF

Application of Inference Models for Estimating Parameters of a Catchment Modelling System (추론모델을 통한 강우-유출모형 매개변수의 간접추정법 적용)

  • Choi, Kyung-Sook
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.587-596
    • /
    • 2003
  • Application of a catchment modelling system requires recorded information to ascertain the reliability and robustness of the predicted flow conditions. Where this recorded information is not available, the necessary information for reliable and robust predictions must be obtained from other available information sources. The alternative approach presented in this paper used inference models for getting this necessary information that is required to calibrate and validate the catchment modelling system for both an ungauged and a gauged catchments. In this study, inference models were developed for determination of control parameters of the Storm Water Management Model (SWMM), mainly based on landuse component of the catchment, which is a major factor to impact on quantity and quality of catchment runoff. Results from the study show that the new approach for determination of the spatially variable control parameters produced more accurate estimates than a traditional approach. Also, the number of control parameters estimated can be reduced significantly as the proposed method only requires determination of control parameters associated with each land use of the catchment while a traditional approach needs to assign a number of control parameters for a number of subcatchment.

A Study on the Installation of a Sewage Separator Pipe inside an Existing Combined Sewer System for CSO Control (기존 합류식 하수관거에 CSO 제어를 위한 하수분리관의 설치에 관한 연구)

  • Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2021
  • Sewage separation which often involves installing a new pipe to separate wastewater flow from stormwater runoff flow can be costly and depends highly on its feasibility in a site. To be able to develop a potentially more economical alternative that can also lessen major road traffic disturbance during this process, a different approach where a smaller sewage separator pipe is installed inside an existing combined sewer pipe was investigated. A small-scale of a box sewer and the proposed sewage separator pipe was constructed in the laboratory to observe and compare the deposition of solids and other solid-associated major pollutants at different flow rates. In addition, three-dimensional flow simulations considering five different scenarios were conducted using Ansys Fluent to observe the effect of the proposed sewage separator pipe to the hydraulic flow if installed inside the combined sewer pipe. Results revealed that the deposition of TSS, TCOD, TN, and TP were reduced by at least 60% when the wastewater was conveyed by the sewage separator pipe instead of the combined sewer pipe. Moreover, the flow simulations conducted showed that there was little to no major disturbance in hydraulic flow and velocity distribution when the sewage separator was installed inside a straight pipe and even at pipe transitions such as intersections, turns, and drop in elevation. Considering the pipe dimensions and the results of the study, the proposed approach can be promising in terms of reduction in pollutant deposition without a major effect on the hydraulic flow. Further investigation and cost-analysis should be done in the future to support these preliminary findings and help alleviate the problems caused by combined sewer overflows by introducing an alternative approach.

Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients (사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰)

  • Ahn, Seung-Kwon;Kim, Yong-Bae;Lee, Ik-Jae;Song, Tae-Soo;Son, Dong-Min;Jang, Yung-Jae;Cho, Jung-Hee;Kim, Joo-Ho;Kim, Dong-Wook;Cho, Jae-Ho;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Purpose: We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by $4{\sim}4.4%$ to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the therapy owing to the reduction of the air gap using a vacuum pump and a vacuum valve. This set-up represents a promising alternative device for delivering a homogenous dose to the target volume.